Permanent explantation of implantable cardioverter defibrillators.

Although ICD therapy is seen as an irrevocable mode of therapy in most patients, a small number of patients do have their devices permanently explanted. The long-term outcome in these patients has not been described. The purpose of this single center study was to evaluate the long-term outcome of patients whose ICD was explanted and not replaced and to propose clinical variables that can be considered when making the decision to discontinue therapy. Ten of 323 (3.1%) patients in our ICD registry had their devices permanently explanted or turned off between 1986 and December 1998. The devices had been in place for 39 +/- 31 months preexplant. No patient had received appropriate therapy prior to surgery, which was indicated for infection or lead fracture. All patients are alive and well 75 +/- 30 months postexplant with 1 (10%) patient requiring late reimplantation. We reviewed the English language literature describing ICD explanation without replacement. A total of 151 patients were reported in eight studies and were followed for up to 30 months postexplant. Excluding patients with terminal illness or heart transplantation 57.6% survived without reimplantation. In selected patients, after not using an ICD for a long period and when clinical circumstances justify, device therapy may be discontinued with some degree of safety.

Adult↗

Incidence of antitachycardia therapy suspension due to magnet reversion in implantable cardioverter defibrillators.

Electromagnetic interference may result in transient or persistent suspension of antitachycardia therapies in ICDs. The incidence of such events has not been assessed so far. Patient charts were retrospectively analyzed for the occurrence of temporary suspension of antitachycardia therapies as it is stored in the Holter of St. Jude Medical or Ventritex ICDs. Follow-up data of 46 patients and 83.7-patient years were analyzed. Overall, 43 episodes of transient ICD inactivation occurred. Twenty-two of these episodes were related to intentional ICD inactivation in the emergency room or during surgery and 12 episodes were related to ICD follow-up. In nine episodes an environmental source of electromagnetic interference is presumed. None of the interactions resulted in persistent ICD inactivation or reprogramming of the devices. The risk for temporary suspension of ICD therapies unrelated to surgery, intentional magnet application in the emergency room, or routine follow-up is 11% per patient and year. Evaluation of its potential sources and the prevalence of ICD inhibition is warranted.

Adolescent↗

Inappropriate implantable cardioverter defibrillator discharge following consumption of a dietary weight loss supplement.

This report describes the clinical course of a 40-year-old female who experienced repetitive ICD firing after consuming Metabolife 356, a multicomponent dietary weight loss supplement. Following the initiation of Metabolife 356, the patient experienced four shocks over a 3 day period with two 30 J shocks being delivered sequentially. Interrogation of the device revealed atrial tachycardia with 1:1 AV conduction at a rate of 240 beats/min. Metabolife 356 was discontinued and the dosage of sotalol was increased to 120 mg twice daily without recurrence of ICD discharge.

Adult↗

Short-term efficacy of a telephone intervention by expert nurses after an implantable cardioverter defibrillator.

The ICD is a common therapy for treatment of ventricular arrhythmias and prevention of sudden cardiac death. After ICD therapy, 50% of survivors are known to have significantly elevated anxiety, depression, anger, and fear in getting back to normal physical activities. Despite these problems, few interventions to improve adjustment have been rigorously evaluated within a clinical trial format. This article reports the short-term efficacy of a structured weekly educational telephone intervention (8 weeks) delivered by expert cardiovascular nurses to recipients of an ICD. To test these effects, a two-group (n = 84/group) randomized clinical trial design was used with measures at baseline (hospital discharge), 1 month, and 3 months after ICD therapy. The study sample were first time ICD recipients for secondary prevention of sudden cardiac arrest. Primary outcomes included (1) physical functioning (Patient Concerns Assessment [PCA], Short-Form Health Survey [SF-12], ICD shocks), (2) psychological adjustment (State-Trait Anxiety Inventory [STAI]), Centers for Epidemiologic Studies-Depression (CES-D), (3) knowledge (Sudden Cardiac Arrest [SCA] knowledge assessment), and (4) health care use (emergency room visits, outpatient visits, hospitalizations). The intervention group, as compared to the control group, significantly reduced mean PCA symptoms at 1 month (11.3-8.8 vs 9.7-9.3, respectively, P < 0.02), and reduced state anxiety (36.1-31.9 vs 33.1-33.0, respectively, P < 0.08), and enhanced knowledge (21.8-22.4 vs 21.4-21.7, respectively, P < 0.02) at 3 months. The intervention did not significantly impact short-term health care use. A structured telephone intervention delivered during the first 8 weeks after ICD therapy by expert cardiovascular nurses decreased ICD related physical symptoms and anxiety, and increased SCA knowledge over 3 months.

Adaptation, Psychological↗

Potential cost savings by telemedicine-assisted long-term care of implantable cardioverter defibrillator recipients.

Home monitoring (HM) of cardioverter defibrillators (ICD) with its automated wireless remote data access, may decrease the rate of patient visits. This study examined the potential cost savings for the long-term care of ICD assisted by HM. A French database including 502 patients from 6 university hospitals was used. Costs of conventional follow-up (FU) of ICD were calculated without, and compared with the expected cost of FU with HM. Calculations included number of visits, including physician's fees, electrocardiograms, and specific ICD surveillance, and transportation costs. The mean distance between home and institutions performing follow-ups was 69 +/- 57 km. For each visit, a mean overall cost of 215 dollars was calculated, including 121 dollars for transportation and 94 dollars for medical services. HM may obviate up to 2 visits per year. Over the 5 years of expected life of the device, the decrease in costs for FU visits was estimated at 2,149 dollars. With an additional cost of 1,200 dollars for the HM system, saving began after a mean FU of 33.5 months. The time to onset of cost saving by HM ranged between 17.4 months for patients living >150 km from the medical facility to 52.2 months for those living <50 km away. It is concluded that the HM may considerably reduce the overall costs of ICD FU by saving on transportation cost, particularly when the distance between home and medical facility is >100 km.

Cost Savings↗

Anodal right ventricular capture during left ventricular stimulation in CRT-implantable cardioverter defibrillators.

BACKGROUND: Cardiac resynchronization therapy (CRT) has been shown to improve symptoms of patients with moderate to severe heart failure. Optimal CRT involves biventricular or left ventricular (LV) stimulation alone, atrio-ventricular (AV) delay optimization, and possibly interventricular timing adjustment. Recently, anodal capture of the right ventricle (RV) has been described for patients with CRT-pacemakers. It is unknown whether the same phenomenon exists in CRT systems associated with defibrillators (CRT-ICD). The RV leads used in these systems are different from pacemaker leads: they have a larger diameter and shocking coils, which may affect the occurrence of anodal capture. METHODS: We looked for anodal RV capture during LV stimulation in 11 consecutive patients who received a CRT-ICD system with RV leads with a true bipolar design. Fifteen patients who had RV leads with an integrated design were used as controls. Anodal RV and LV thresholds were determined at pulse width (pw) durations of 0.2, 0.5, and 1.0 ms. RESULTS: RV anodal capture during LV pacing was found in 11/11 patients at some output with true bipolar RV leads versus 0/15 patients with RV leads with an integrated bipolar design. Anodal RV capture threshold was more affected by changes in pw duration than LV capture threshold. In CRT-ICD systems, RV leads with a true bipolar design with the proximal ring also used as the anode for LV pacing are associated with a high incidence of anodal RV capture during LV pacing. This may affect the clinical response to alternative resynchronization methods using single LV stimulation or interventricular delay programming.

Adult↗

Chronotropic incompetence in patients with an implantable cardioverter defibrillator: prevalence and predicting factors.

Chronotropic incompetence (CI), which has not been systematically examined in the ICD patient population, may have implications for device programming. A total of 123 ICD patients were classified into three groups: single-chamber ICD with sinus rhythm, dual-chamber ICD with sinus rhythm, and single-chamber ICD with permanent atrial fibrillation. Heart rate response, maximum oxygen uptake, and oxygen uptake at the anaerobic threshold were measured during treadmill exercise testing. In addition, clinical variables such as antiarrhythmic drug therapy, underlying heart disease, and left-ventricular (LV) ejection fraction were recorded. Of the patients studied, 38% were chronotropically incompetent (47/123). Significant predictors of CI were as follows: presence of a coronary disease (P = 0.036), prior cardiac surgery (P = 0.037), chronic drug therapy with beta-blockers (P = 0.032), administration of amiodarone (P = 0.025), and a combination of these two forms of treatment (P = 0.01). Spiroergometry revealed reduced exercise capacity (P = 0.041) and lessened VO2max (P = 0.034) among chronotropically incompetent patients. A large percentage of ICD patients demonstrates CI with subsequently reduced physical stress tolerance. In light of the DAVID study, we believe that a closer examination of rate-adaptive modes for ICD patients is warranted under enhanced conditions: (1) optimized AV interval programming; (2) utilization of new algorithms to reduce ventricular pacing in combination with rate-adaptive atrial pacing, with the goal of addressing CI while minimizing ventricular pacing; and (3) an optimized upper heart-rate limit.

Arrhythmias, Cardiac↗

T-wave oversensing by an implantable cardioverter defibrillator after successful ablation of idiopathic ventricular fibrillation.

Focal ablation of trigger premature ventricular complexes (PVCs) from the Purkinje system helped to suppress idiopathic ventricular fibrillation (VF) in an athlete who had suffered from frequent appropriate shock therapies. However, only a few days after successful ablation T-wave oversensing occurred during exercise and resulted in repetitive distressing defibrillator shocks. Despite lack of any changes on the surface ECG, the endocardially recorded electrogram revealed an unfavorable ratio of R-to-T-wave amplitude predisposing to double counting with accelerated heart rates. This case illustrates that T-wave oversensing may complicate the clinical course after successful ablation of malignant Purkinje ectopy.

Adult↗

Measurement of patient fears about implantable cardioverter defibrillator shock: an initial evaluation of the Florida Shock Anxiety Scale.

BACKGROUND: Psychological distress is both a precipitant and a consequence of ICD shock. Therefore, the assessment of patient anxiety and concerns related to receiving an ICD shock may prompt appropriate psychological referrals and treatment. METHODS: The purpose of this study is to assess the initial validity and clinical utility of the Florida Shock Anxiety Scale (FSAS). Seventy-two ICD recipients completed the FSAS. RESULTS: Exploratory factor analysis revealed a two-factor structure with items loading such that Factor 1 could be conceptualized as a Consequence Factor (e.g., fearing creating a scene if the device were to fire) and Factor 2 as a Trigger Factor (e.g., fearing sexual activity). Alpha coefficients suggest good reliability (Cronbach's alpha= 0.91, split-half = 0.92), and FSAS Total Score was moderately correlated (r =-0.65) with total score on the Multidimensional Fear of Death Scale. CONCLUSIONS: Two subscales, labeled consequence of shock and trigger of shock, were established via factor analysis. Collectively the FSAS demonstrates potential utility to assess shock distress and warrants additional investigation.

Anxiety↗

Successful use of a transvenous dual-chamber automatic implantable cardiac defibrillator after a classic Fontan operation for tricuspid atresia.

We report the first successful totally percutaneous pacing and defibrillation of a single ventricle in a 52-year-old woman who had undergone a classic Fontan operation (atriopulmonary connection) for tricuspid atresia 21 years earlier. Left ventricular pacing and sensing was obtained with a bipolar lead in the lateral cardiac vein, and defibrillation was obtained with a coronary sinus coil lead and an "active can" in the retromammary position to optimize the current vector. This approach has significant potential benefits because it avoids a repeat thoracotomy, with its associated mortality and morbidity.

Combined Modality Therapy↗

Implantable cardioverter defibrillator patch erosion presenting as hemoptysis.

Although the internal cardioverter defibrillator has prevented many premature deaths from lethal ventricular arrhythmias, some complications have occurred with its use. We present a patient who developed a fistula between the left ventricle and a bronchus, caused by erosion of the ventricular patch. The patient's presenting symptom was hemoptysis. Physicians caring for patients with these devices should be aware of this potential problem.

Animals↗