PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Visualized analysis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64Linked to original sources

Validation of brain tumour imaging with p-[123I]iodo-L-phenylalanine and SPECT.

PURPOSE: The aims of this prospective study were to validate single-photon emission computed tomography (SPECT) with p-[(123)I]iodo-L-phenylalanine (IPA) in brain tumours and to evaluate its potential for the characterisation of indeterminate brain lesions. METHODS: In 45 patients with indeterminate brain lesions or suspected progression of glioma, amino acid uptake was studied using IPA-SPECT and compared with the final diagnosis established by biopsy or serial imaging. After image fusion of IPA-SPECT and magnetic resonance imaging, the presence of tumour was visually determined by two independent observers. IPA uptake was quantified as the ratio between maximum uptake in the suspicious lesion and mean uptake in unaffected brain. RESULTS: Primary brain tumours were present in 35 cases (12 low-grade and 23 high-grade gliomas). Non-neoplastic brain lesions were confirmed in seven cases (three dysplasias, three inflammatory lesions, one lesion after effective therapy). Visual analysis showed a high concordance between the two observers (kappa=0.90, p<0.001), with sensitivity and specificity of 86% and 100% for the discrimination of primary brain tumours and non-neoplastic lesions. At 30 min p.i., IPA uptake in primary brain tumours was higher than that in non-neoplastic lesions (1.70+/-0.36 vs 1.14+/-0.18, p<0.05). Brain metastases showed no increased uptake (1.13+/-0.22, n=3). The persistent retention of IPA in low-grade gliomas without disruption of the blood-brain barrier was visualised up to 24 h p.i. Low-grade and high-grade gliomas showed equivalent IPA uptake (1.72+/-0.37 vs 1.67+/-0.36 at 30 min, p=0.745). CONCLUSION: IPA shows long and specific retention in gliomas. IPA is a promising and safe radiopharmaceutical for the visualisation of gliomas and the characterisation of indeterminate brain lesions.

Adult↗

Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT.

PURPOSE: To evaluate the use of CT attenuation maps, generated from coronary calcium scoring (CCS) scans at in- and expiration with a 64-slice CT scanner, for attenuation correction (AC) of myocardial perfusion SPECT images. METHODS: Thirty-two consecutive patients underwent( 99m)Tc-tetrofosmin gated adenosine stress/rest SPECT scan on an Infinia Hawkeye SPECT-CT device (GE Medical Systems) followed by CCS and CT angiography on a 64-slice CT. AC of the iteratively reconstructed images was performed with AC maps obtained: (a) from the "Hawkeye" low-resolution X-ray CT facility attached to the Infinia camera (IRAC); (b) from the CCS scan acquired on a 64-slice CT scanner during maximal inspiration (AC(INSP)) and (c) during normal expiration (AC(EXP)). Automatically determined uptake values of stress scans (QPS, Cedars Medical Sinai) from AC(INSP) and AC(EXP) were compared with IRAC. Agatston score (AS) values using AC(INSP)versus AC(EXP) were also compared. RESULTS: AC(INSP) and AC(EXP) resulted in identical findings versus IRAC by visual analysis. A good correlation for uptake values between IRAC and AC(INSP) was found (apex, r=0.92; anterior, r=0.85; septal, r=0.91; lateral, r=0.86; inferior, r=0.90; all p<0.0001). The correlation was even closer between IRAC and AC(EXP) (apex, r=0.97; anterior, r=0.91; septal, r=0.94; lateral, r=0.92; inferior, r=0.97; all p<0.0001). The mean AS during inspiration (319+/-737) and expiration(317+/-778) was comparable (p=NS). CONCLUSION: Attenuation maps from CCS allow accurate AC of SPECT MPI images. AC(EXP) proved superior to AC(INSP), suggesting that in hybrid scans CCS may be performed during normal expiration to allow its additional use for AC of SPECT MPI.

Adult↗

Prediction of functional outcome by quantification of sestamibi and BMIPP after acute myocardial infarction.

Iodine-123 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) can be used to image myocardial fatty acid regional distribution and utilisation with single-photon emission tomography (SPET). By visual analysis, a mismatching with regional uptake of BMIPP less than that of a perfusion tracer has been shown to predict myocardial viability and functional improvement after restoration of flow in patients with myocardial infarction. The current study aimed to evaluate a newly developed quantitative method of analysis of sestamibi and BMIPP uptake for the prediction of functional recovery after revascularization in patients with acute infarction. BMIPP and gated sestamibi SPET studies at rest were obtained before and >3 months after revascularization in 18 patients with recent infarction. A colour-coded polar map was generated from the comparison of sestamibi and BMIPP uptake. Depending on the relative distribution of the two tracers, different patterns of uptake were identified and their extent expressed as percentages of the surface of the whole left ventricle and of the three main coronary artery territories. At follow-up, recovery was defined as a > or =5% increase in ejection fraction compared with baseline. Receiver-operating characteristic curve analysis was performed to analyse the data. At baseline, significant correlations were found between ejection fraction and the % surface with decreased sestamibi or BMIPP uptake (r=-0.68, P= 0.001, and r=-0.72, P<0.0001, respectively). When combining both tracers, ejection fraction was significantly associated with the extent of myocardium showing decreased sestamibi uptake with lower BMIPP uptake (mismatching; r=-0.68, P=0.001). At follow-up, significant functional recovery was found in 13/18 patients. By ROC curve analysis, the optimal pattern of distribution predicting recovery was a mismatching with uptake of sestamibi <70% and uptake of BMIPP at least 10% lower. For this parameter, optimal cut-off of extent was 10% of the whole left ventricle surface (sensitivity 69%, specificity 80%, accuracy 72%) and 25% of the infarct-related arterial territory (sensitivity 77%, specificity 80%, accuracy 78%). The areas under the curve were 79% for the left ventricle surface and 72% for the individual arterial territories. These results suggest that in patients with acute infarction, quantitative analysis of sestamibi and BMIPP could offer an objective and reproducible method for estimating the severity of cardiac dysfunction and predicting the evolution of ejection fraction after revascularization.

Fatty Acids↗

Clinical evaluation of no-carrier-added meta-[123I]iodobenzylguanidine for myocardial scintigraphy.

In clinical and research studies, images obtained using carrier-added meta-[123I]iodobenzylguanidine (c.a. [123I]MIBG) have shown quite variable quality, with varying levels of uptake in lung, liver and mediastinum; this is a significant problem for quantification of the myocardial uptake by means of region ratios. First experimental and preliminary human data in respect of no-carrier-added (n.c.a.) [123I]MIBG are indicative of improved imaging quality. The aim of the present study was to evaluate the clinical value of myocardial scintigraphy with n.c.a. [123I]MIBG in patients with tachyarrhythmias. The study population comprised 24 patients with tachyarrhythmogenic diseases routinely studied by cardiac single-photon emission tomography (SPET) with [123I]MIBG. Twelve of the 24 patients were studied with c.a. [123I]MIBG (seven females and five males; mean age 42+/-13 years, range 20-60 years), whereas the other 12 were studied with n.c.a. [123I]MIBG (ten females, two males; mean age 41+/-11 years, range 18-60 years, P=NS). For quantification of the specific uptake in the different organs, count ratios were calculated on SPET images acquired 4 h p.i. Visual analysis of all [123I]MIBG scans showed improved image quality (improved contrast between heart and neighbouring organs) in n.c.a. studies as compared with c.a. studies. A significantly higher heart/left atrial blood ratio was found in the n.c.a. studies as compared with the c.a. studies (10.3+/-3.2 vs 5.3+/-1.3, P=0.0003); furthermore, significantly higher heart/lung and heart/liver ratios (2.5+/-0.6 vs 1.5+/-0.3, P=0.0002, and 0.8+/-0.2 vs 0.6+/-0.1, P=0.0006, respectively) were obtained in the c.a. studies, whereas lung/left atrial blood and liver/left atrial blood ratios showed no significant differences (4.2+/-1.3 vs 3.6+/-1.1, P=0.39, and 13.7+/-5.2 vs 9.6+/-2.2, P=0.21, respectively). In conclusion, the use of n.c.a. [123I]MIBG yields a significantly higher myocardial uptake associated with improvement in contrast between the heart and neighbouring organs and is therefore superior to the commercially available c.a. [123I]MIBG for use in clinical and research studies of the myocardial presynaptic sympathetic nervous system. Furthermore, our data indicate that for quantification the use of a left atrial blood reference region of interest, which is only available on SPET studies, is to be recommended.

3-Iodobenzylguanidine↗

False-positive defects in technetium-99m sestamibi myocardial single-photon emission tomography in healthy athletes with left ventricular hypertrophy.

Exercise ECG and myocardial single-photon emission tomography (SPET) are fundamental in the non-invasive evaluation of patients suspected of having coronary artery disease (CAD). The purpose of the present study was to investigate the influence of physiological left ventricular hypertrophy (LVH) on myocardial sestamibi SPET in healthy young and old athletes. Eighteen young male elite athletes (ten rowers, five power/weight lifters and three triathletes) and 14 well-trained elderly rowers were studied. All underwent a bicycle test as part of a 2-day sestamibi SPET protocol. Attenuation correction was not performed. The studies were evaluated visually and quantitatively analysed by the CEqual program with its reference files and with a file from a local non-athletic age-matched population. Echocardiographic LVH was an inclusion criterion in the young athletes. Exercise ECG was normal in all subjects. In at least three of the young athletes a reversible defect was observed by visual analysis. On quantitative analysis one-third of the young athletes had "significant" (>10 pixels) defects compared with both the local reference base and the CEqual reference population. Nearly all defects were found in the anterior or inferior wall. The remaining subjects, including all old rowers, had normal SPET findings. Anterior and inferior wall defects are so common in healthy athletes with physiological LVH that the specificity of myocardial SPET, in contrast to exercise ECG, seems to be too low for evaluation of chest pain in this group. The mechanism of anterior and inferior defects may be related to hot spots (papillary muscles?) in the lateral wall. The specificity of SPET is maintained in athletes without LVH.

Adult↗

Optimal scan time for fluorine-18 fluorodeoxyglucose positron emission tomography in breast cancer.

Fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) has proven useful in the differentiation of various tumour entities, including breast cancer. In patients with primary breast cancer we performed a 3-h imaging protocol to examine possible improvements in tumour detectability and image contrast. Twenty-nine patients with primary breast cancer with a diameter of >/=2 cm that was demonstrated to be malignant by biopsy or surgery were injected with 370-740 MBq 18F-FDG and scanned in the prone position. Data were acquired 0-40 min, 1.5 h and 3.0 h after injection. After correction for measured attenuation, decay and scatter and iterative reconstruction, standardised uptake values (SUVs) and tumour-to-non-tumour and tumour-to-organ ratios were calculated. Visual analysis was performed using transverse, sagittal and coronal slices as well as 3D reprojection images. Tumour-to-non-tumour and tumour-to-organ ratios were significantly higher for the 3-h images than for the 1.5-h images. SUVs did not increase to the same extent. Lesion detectability was 83% in 1.5-h images compared to 93% in 3-h images. We conclude that tumour contrast in breast cancer is improved by starting the PET acquisition at 3 h p.i. rather than at 1.5 h p.i.

Adult↗

Incremental prognostic value of myocardial SPET with dual-isotope rest (201)Tl/stress (99m)Tc-tetrofosmin.

The incremental prognostic value of dual-isotope myocardial perfusion scintigraphy using technetium-99m tetrofosmin for the stress images was evaluated in 597 consecutive patients with known or suspected coronary artery disease. We used semi-quantitative visual analysis with a five-point scoring system and calculated the summed stress score, the summed rest score and the summed difference score. During the 2-year follow-up period, 46 "hard" cardiac events occurred: 16 cardiac deaths and 30 non-fatal myocardial infarctions. Kaplan-Meier analysis demonstrated a favourable prognosis for patients with normal scans as compared with patients with mildly to moderately or severely abnormal scans ( P<0.001). Multivariate analysis demonstrated incremental prognostic information for nuclear variables. A very low rate of hard cardiac events was observed in patients with a low summed stress score. Thus, nuclear variables provide incremental prognostic information and could be used to guide the management process with respect to whether or not to proceed with further invasive procedures.

Adult↗

Evaluation of pancreatic carcinoma with FDG PET.

BACKGROUND: To assess the diagnostic usefulness and clinical impact of positron emission tomography with [F-18]fluorodeoxyglucose (FDG PET) on the management of patients with known or suspected pancreatic carcinoma. METHODS: Attenuation-corrected FDG PET was performed in 20 patients (12 male, eight female) with pancreatic carcinoma at the time of initial diagnosis (n = 7), for tumor surveillance after Whipple surgery (n = 11), and for reevaluation after chemoradiation therapy (n = 2). Visual analysis of PET images were correlated with the results of abdominal computed tomography (CT) and carbohydrate antigen (CA) 19-9 serum tumor marker level that were obtained within 1 month of the PET study. Diagnostic validation was by histology in nine patients and by clinical or radiologic follow-up (5-48 months) in 11 patients. Changes in therapeutic management that were prompted by PET were tabulated. RESULTS: PET was concordant with the findings of abdominal CT in 14 patients (13 true positive, 1 true negative). PET detected clinically unsuspected lung lesions, confirmed subsequently by a chest CT, in one of these 14 patients. PET was discordant with CT in six patients. PET detected tumor recurrence in three patients in this group (15% of total) with nondiagnostic CT findings and elevated CA 19-9 serology. In two of these three patients, chemotherapy with gemcitabine was initiated based on PET localization of disease. Tumor was confirmed in the remaining one of the three patients at autopsy shortly after the PET study. FDG localization in a displaced loop of bowel resulted in an apparent false-positive hepatic lesion in one of six patients in the discordant group. PET underestimated the extent of metastatic disease in the remaining two of six patients due to hyperglycemia. CONCLUSION: In patients with suspected pancreatic carcinoma at the time of initial presentation, PET is complementary to abdominal CT and allows detection of unsuspected distant metastases. In patients with suspected recurrent pancreatic carcinoma, based on elevated or rising CA 19-9 serology, PET can localize the disease when abdominal CT is nondiagnostic as a result of posttherapy anatomic alteration. Imaging evaluation with PET may impact the clinical management of patients with pancreatic carcinoma.

Adult↗

ENVIRONMENTAL AUDITING: Use of Landsat Thematic Mapper Data to Assess Seasonal Rangeland Changes in the Southeast Kalahari, Botswana.

/ Management problems arise in semiarid rangeland that are characterized by marked wet and dry seasons because of forage deficiencies in the dry season. These natural vegetation rangelands can sustain livestock all year long when forage and senesced grass are available into the dry season. Seasonal range condition data are required to provide a basis for pasture management to help locate dry season cover and thereby minimize overstocking and degradation. The generation of seasonal data using Thematic Mapper (TM) imagery was undertaken to assess changes in natural vegetation cover in the southern Botswana Kalahari. Visual analysis of spectral reflectance curves, the development of spectral separability indexes, and conventional classification analysis techniques were used to identify and differentiate rangeland features. Results from reflectance curves indicated that most rangeland cover types could be preferentially distinguished using mainly wet season data, especially on the longer TM wavebands, and that range feature differentiation was more problematic on darker soils than on lighter soils. Spectral separability indexes (SSIs) confirmed that range feature separation varied considerably as a function of waveband and was more effective in the wet than the dry season. The SSIs also showed that range feature differentiation in both seasons was most effective using a combination of the chlorophyll absorpance band (TM3) and two mid-infrared bands (TM5 and TM7). Wet season data were more effectively classified in terms of range features than dry season data although some class similarity was inferred across the two classified data sets. The work shows that overall trends may be generated by comparing seasonal data sets, thereby providing an overall basis for dry season decision making. However, particular problems arise within the dry season data sets probably because of spectral similarities between shadow and darkened vegetation cover, thereby implying that further work is needed. KEY WORDS: Semiarid rangelands; Botswana; Kalahari; Spectral differentiation; Seasonal change; Darkened vegetation cover

Journal Article↗

Radiologic-pathologic correlations of intratumoral tissue components in the most common solid and cystic renal tumors. Pictorial review.

This paper describes the correlation between US-CT images and pathologic findings in the most common solid and cystic renal tumors, to better differentiate malignant and benign renal masses. Several intratumoral tissue components present correlation with US-CT images. Macroscopic components, corresponding to necrotic, hemorrhagic and cystic changes, are identified by visual analysis of the gross specimen, while microscopic components are identified by histopathologic analysis. Microscopic components are classified as cellular [(1) high cellularity with poor extracellular stroma, +/-high nucleus-cytoplasm ratio+/-high uniformity in tumoral cells dimensions; (2) low cellularity with large extracellular stroma+/-low nucleus-cytoplasm ratio+/-low uniformity in tumoral cells dimensions], stromal [(1) fibrotic; (2) fibrovascular; (3) fibromyxoid], vascular related to neoangiogenesis, necrotic [(1) coagulative; (2) colliquative; (3) hemorrhagic], calcific, and adipose.

Cysts↗

Reducing dose in urography while maintaining image quality-a comparison of storage phosphor plates and a flat-panel detector.

The introduction of new flat-panel detector technology often forces us to accept too high dose levels as proposed by the manufacturers. We need a tool to compare the image quality of a new system with the accepted standard. The aim of this study was to obtain a comparable image quality for two systems-storage phosphor plates and a flat-panel system using intravenous urography (IVU) as a clinical model. The image quality figure was calculated using a contrast-detail phantom (CDRAD) for the two evaluated systems. This allowed us to set a dose for the flat-panel system that gave equivalent image quality to the storage phosphor plates. This reduced detector dose was used in an evaluation of clinical images to find out if the dose reduction from the phantom study indeed resulted in images of equal clinical image quality. The image quality was assessed using image criteria of the European guidelines for IVU with visual grading analysis. Equivalent image quality in image pairs was achieved at 30% of the dose. The CDRAD contrast-detail phantom makes it possible to find dose levels that give equal image quality using different imaging systems.

Aged↗

Breast imaging. Preoperative breast cancer staging: comparison of USPIO-enhanced MR imaging and 18F-fluorodeoxyglucose (FDC) positron emission tomography (PET) imaging for axillary lymph node staging--initial findings.

Magnetic resonance (MR) imaging after ultra-small super paramagnetic iron oxide (USPIO) injection and 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) for preoperative axillary lymph node staging in patients with breast cancer were evaluated using histopathologic findings as the reference standard. USPIO-enhanced MR and FDG-PET were performed in ten patients with breast cancer who were scheduled for surgery and axillary node resection. T2-weighted fast spin echo, T1-weighted three-dimensional (3D) gradient echo, T2*-weighted gradient echo and gadolinium-enhanced T1-weighted 3D gradient echo with spectral fat saturation were evaluated. MR imaging before USPIO infusion was not performed. The results were correlated with FDG-PET (acquired with dedicated PET camera, visual analysis) and histological findings. The histopathologic axillary staging was negative for nodal malignancy in five patients and positive in the remaining five patients. There was one false positive finding for USPIO-enhanced MR and one false negative finding for FDG-PET. A sensitivity (true positive rate) of 100%, specificity (true negative rate) of 80%, positive predictive value of 80%, and negative predictive value of 100% were achieved for USPIO-enhanced MR and of 80%, 100%, 100%, 80% for FDG-PET, respectively. The most useful sequences in the detection of invaded lymph nodes were in the decreasing order: gadolinium-enhanced T1-weighted 3D gradient echo with fat saturation, T2*-weighted 2D gradient echo, T1-weighted 3D gradient echo and T2-weighted 2D spin echo. In our study, USPIO-enhanced T1 gradient echo after gadolinium injection and fat saturation emerged as a very useful sequence in the staging of lymph nodes. The combination of USPIO-enhanced MR and FDG-PET achieved 100% sensitivity, specificity, PPV and NPV. If these results are confirmed, the combination of USPIO MR with FDG-PET has the potential to identify the patient candidates for axillary dissection versus sentinel node lymphadenectomy.

Adult↗

[Visual assessment or quantitative measurement of coronary stenoses: significance for "prima vista"-PTCA].

In 300 patients with 339 coronary lesions the percent diameter stenosis (%-DS) was assessed both by visual estimation and by digital quantitative coronary angiography (DQCA) by use of an on-line computer work-station. The decision for coronary angioplasty in the same setting ("prima vista"-PTCA) was based on history, evidence of ischemia and visual estimation of %-DS. DQCA measurements of the 339 stenoses revealed a normal distribution of lesion severity with a mean of 58.4 +/- 11.3%. In contrast to DQCA visual estimation led to a bimodal distribution with a nadir at approximately 55% between two peaks at approximately 45% and approximately 75% and a mean of 70.5 +/- 19.6%. Visual estimation underestimated lesions in the range of 30-55% and overestimated the %-DS between 55-99%. Visual estimation revealed a %-DS > or = 60% in 251 stenoses (74.0%) of the 339 lesions, an estimate that led to subsequent "prima vista"-PTCA. Conversely, DQCA revealed only 184 stenoses (54.3%) with a %-DS > or = 60%; thus, 86 stenoses (25.3%) did not meet the morphologic indication criteria for PTCA. The bimodal distribution of stenosis severity according to visual analysis with an overestimation of borderline stenosis severity reflects at tendency for "self-referral" of patients for PTCA. DQCA serves as an objective tool in the decision-making process for PTCA and may reduce "cosmetic" interventions or justify to defer PTCA. Especially in the selection process for "prima vista"-PTCA DQCA-quantification of stenosis severity is recommended.

Aged↗

Comparative values of catecholamines and metabolites for the diagnosis of neuroblastoma.

UNLABELLED: In order to diagnose neuroblastomas, we assayed the three adrenal hormones and five of their metabolites by high-performance liquid chromatography followed by electrochemical detection in urine samples of 395 children with tumours of unknown nature (including 29 neuroblastomas). The analytes (expressed as analyte/creatinine ratios) performances were determined by calculating the related sensitivity and specificity and receiver operating characteristics curves within the different age groups. Normetanephrine (NME), vanillylmandelic and homovanillic acids (VMA, HVA) were the best analytes. Calculated optimal thresholds (best specificity/sensitivity couples) of these analytes minimised the number of false-positive diagnosis. CONCLUSION: combined determination of normetanephrine with vanillylmandelic acid (0-1 year) or homovanillic acid (1-5 years and 5-10 years) further enhanced the diagnostic power up to 100% sensitivity and specificity of the testing depending on the age group. Plotting individual levels (normetanephrine versus vanillylmandelic acid or homovanillic acid) allowed a rapid visual analysis that would have missed only one small low grade non-secreting tumour.

Adrenal Gland Neoplasms↗

Detection of movement artifact in recorded pulse oximeter saturation.

UNLABELLED: Movement artifact (MA) must be detected when analysing recordings of pulse oximeter saturation (SpO2). Visual analysis of individual pulse waveforms is the safest, but also the most tedious, method for this purpose. We wanted to test the reliability of a computer algorithm (Edentec Motion Annotation System), based on a comparison between pulse and heart rate, for MA detection. Ten 12-h recordings of SpO2, pulse waveforms and heart rate from ten preterm infants were analysed for the presence of MA on the pulse waveform signal. These data were used to determine the sensitivity and specificity of the computer algorithm, and of the oximeter itself, in detecting MA. Recordings were divided into segments of 2.5 s duration to compare the movement identification methods. Of the segments 31% +/- 6% (mean +/- SD) contained MA. The computer algorithm identified 95% +/- 3% of these segments, the pulse oximeter only 18% +/- 11%. Specificity was 85% +/- 4% and 99% +/- 0%, respectively. SpO2 was < or =80% in 3% +/- 1% of segments. 88% +/- 7% of the pulse waveform signal showed MA during this time, leaving a significant potential for erroneous identification of hypoxaemia. Recordings of SpO2 do not allow a reliable identification of MA. CONCLUSION: Without additional information about movement artifact, a significant proportion of recording time of pulse oximeter signal may be regarded as demonstrating hypoxaemia which, in fact, simply reflects poor measurement conditions. The computer algorithm used in this study identified periods of movement artifact reliably.

Algorithms↗

Genetic polymorphisms of the renin-angiotensin system and angiographic extent and severity of coronary artery disease: the CORGENE study.

Genetic polymorphisms of the renin-angiotensin system (RAS) have been associated with coronary artery disease (CAD) but no relation between these polymorphisms and coronary atherosclerosis has yet been systematically evaluated. The CORGENE study is a cross-sectional study involving 463 Caucasians who underwent standardized coronary angiography for established or suspected CAD [156 patients with a previous myocardial infarction (MI), 307 without MI]. Four angiographic scores assessing the extent and severity of the coronary lesions were obtained from a double visual analysis of each angiogram, arbitration being achieved by a quantitative measurement. Three different genotypes were analyzed: the angiotensin I-converting enzyme insertion/deletion (ACE I/D) polymorphism, the Met to Thr change at position 235 of the angiotensinogen gene (AGT M235T) and the A to C transition at position 1166 of the angiotensin II type-1 receptor gene (AT1R A1166C). No significant association was observed between these polymorphisms and the clinical characteristics of MI and non-MI subjects. While most classical risk factors were positively correlated with the angiographic scores, no significant relationship could be established with the three genotypes (r ranging from -0.08 to 0.05). Only one significant correlation was observed: between the presence of the AGT 235T allele and the extent of the coronary lesions (r = -0.19, P = 0.04) in patients with low-risk status. These overall results are not in favor of a role of these RAS genetic polymorphisms in the development of coronary atherosclerosis.

Angiotensinogen↗

A new probe for ankle systolic pressure measurement using photoplethysmography (PPG).

An automated method for ankle systolic pressure measurement, less operator dependent than the standard continuous wave (CW) Doppler technique, would imply an advantage both in patient measurements and in epidemiological studies. We present a new photoplethysmographic (PPG) probe that uses near-infrared light (880 nm) to detect pulsatory blood flow underneath the distal end of a standard pneumatic cuff. The probe is adapted to the anatomical conditions at the ankle, permitting recording of pressures in both ankle arteries separately. The validity of the equipment was tested with CW Doppler-derived systolic pressures and invasive blood pressure measurements for reference. In 20 healthy subjects, visual analysis of the PPG curves revealed a mean difference between CW Doppler and PPG measurements of -0.5 mmHg (SD 6.9). Corresponding results for the anterior and posterior tibial arteries separately were -1.8 mmHg (SD 6.2) and 0.9 mmHg (SD 7.3), respectively. A correct probe position was essential for the results. In direct recordings from the dorsalis pedis artery in 10 intensive care patients, PPG underestimated systolic pressure in the anterior tibial artery by 4.5 mmHg (SD 12.1). With further development, the PPG probe, integrated in the pneumatic cuff, may simplify measurements of ankle systolic pressures.

Adolescent↗

Evolution of regional left ventricular wall motion abnormalities in acute Q and non-Q wave myocardial infarction.

The evolution of segmental wall motion in Q and non-Q wave acute myocardial infarction was studied in detail in 15 patients without known prior ischemic events. Serial two-dimensional echocardiographic studies were performed beginning early after the onset of chest pain and continuing until 10 to 14 days after admission. An area of apparent infarction was identified on each initial study based on later correlation of ECG and echocardiographic findings. Wall motion of infarct-and noninfarct-related areas was graded in a semiquantitative fashion based on the scoring of a visual analysis. Sequential image data demonstrated significant spontaneous improvement in wall motion of the infarct area in non-Q but not in Q wave events. Patients with non-Q wave infarction and improvement in regional function were at high risk for recurrent infarction within 6 months. Improvement in wall motion inside or outside the area of infarction in Q wave events was related to future risk. We concluded that in patients with initial acute myocardial infarction, failure to develop Q waves correlated with return of function in the apparent area of infarction. Improvement in regional wall motion after the initial study suggested risk for future ischemic events in both ECG types of myocardial infarction. Serial echocardiographic imaging may be a means to identify patients at risk for infarct extension in both non-Q and Q wave events.

Echocardiography↗