PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Acceleration”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65Linked to original sources

An objective determination of +Gz acceleration tolerance.

Until recently, human +Gz acceleration tolerance has relied solely on subjective criteria relating to loss of vision. By use of newly developed noninvasive instrumentation using a transcutaneous Doppler flow system, objective end point criteria have been developed based on measured blood flow to the head. The system consists of miniature 8 MHz Doppler sensors (2 x 1 x 0.5 cm) placed on the forehead over both frontal branches of the temporal arteries to detect blood flow velocity from back scattered ultrasound. Its use has allowed for correlation of altered, decreased and actual reversal of eye level blood flow with subsequent central light loss. Over 100 subjects have now been studied during more than 2,000 centrifuge runs. Objective changes in temporal artery flow velocity consistently preceded visual degradation for each subject during all acceleration profiles. No subject has gone unconscious without first exhibiting a minimum 6 sec of total flow cessation. Retrograde flow followed by complete flow cessation always preceded central light loss. Results indicate that this method can be successfully used with a wide variety of tasks during exposure to +Gz acceleration. It is recommended for use during evaluation of protective maneuvers or devices on the centrifuge or during actual flight in high performance aircraft. It may also serve as a potential safety monitor during space Shuttle re-entry if there is doubt about a passenger's cardiovascular status.

Acceleration↗

Comparison of performance standards for radiation beam uniformity characteristics of a linear accelerator.

The recent international standards published by the International Electrotechnical Commission (IEC) on the performance of medical electron accelerators describe suggested test procedures for the performance of radiotherapy accelerators. The recommendations of the Nordic Association of Clinical Physics for testing of the radiation beam characteristics include test conditions, methods and suggested tolerances that are different from those of the IEC. In this work the two publications were compared for acceptance testing of a Philips SL25 linear accelerator. It is important to gain experience on the practical use of these standards.

Europe↗

Recording of short-latency vestibular evoked potentials induced by acceleration impulses in experimental animals: current status of the method and its applications.

The short-latency vestibular evoked potential (VsEP) induced by angular acceleration impulses (maximal amplitude 30,000 deg/sec2, rise time 2-3 msec) was recorded by skin electrodes in intact cats after various surgical and pharmacological procedures. The normal VsEP consists of 5-8 waves, several microvolts in amplitude, during the first 10 msec. The latency of the first wave (P1) is about 2 msec with respect to the start of head acceleration. The first and the second waves (P1 and P2) were shown to originate from the vestibular nerve and nucleus, respectively. The VsEP disappears permanently after bilateral labyrinthectomy, excision of the 8th nerves, or administration of large doses of gentamicin. Temporary disappearance is caused by anoxia induced for a brief period of time or injection of lidocaine (4%) into the vestibular nerve or into the inner ear after contralateral labyrinthectomy. The VsEPs in the intact cat are similar whether clockwise or counterclockwise stimuli are used and are not affected by changing the position of the head. Unilaterally labyrinthectomized animals, however, show asymmetric response whereby excitatory stimulation of any of the intact semicircular canals evokes prominent P1 and P2 waves which are absent with inhibitory stimulation. The rate and input-output intensity functions of the VsEP are described. The threshold of the VsEP was found to be 1000-1500 deg/sec2. In addition to the neurogenic waves, 2 other potentials appear occasionally in the response: large-amplitude and longer-duration waves with latencies of 8-20 msec, which are of myogenic origin, and smaller waves with shorter latency which probably represent vestibular microphonics and generator potentials. Extracellular recordings of the responses of single second-order neurons in the vestibular nuclei to the same acceleration impulses confirmed that the kinetic vestibular neurons can respond to these stimuli with a latency as short as 3.5 msec. This method for inducing and recording VsEPs has proved to be a powerful tool for the evaluation of vestibular function in experimental animal models.

Acceleration↗

Cell inactivation, repair and mutation induction in bacteria after heavy ion exposure: results from experiments at accelerators and in space.

To understand the mechanisms of accelerated heavy ions on biological matter, the responses of spores of B. subtilis to this structured high LET radiation was investigated applying two different approaches. 1) By the use of the Biostack concept, the inactivation probability as a function of radial distance to single particles' trajectory (i.e. impact parameter) was determined in space experiments as well as at accelerators using low fluences of heavy ions. It was found that spores can survive even a central hit and that the effective range of inactivation extends far beyond impact parameters where inactivation by delta-ray dose would be effective. Concerning the space experiment, the inactivation cross section exceeds those from comparable accelerator experiments by roughly a factor of 20. 2) From fluence effect curves, cross sections for inactivation and mutation induction, and the efficiency of repair processes were determined. They are influenced by the ions characteristics in a complex manner. According to dependence on LET, at least 3 LET ranges can be differentiated: A low LET range (app. < 200 keV/micrometers), where cross sections for inactivation and mutation induction follow a common curve for different ions and where repair processes are effective; an intermediate LET range of the so-called saturation cross section with negligible mutagenic and repair efficiency; and a high LET range (>1000 keV/micrometers) where the biological endpoints are majorly dependent on atomic mass and energy of the ion under consideration.

Bacillus subtilis↗

Choice of optimum megavoltage for accelerators for photon beam treatment.

Over three decades ago, the development of megavoltage accelerators revolutionized radiation oncology and provided the therapist with photons and electrons of any desired energy. The initial advantages cited for high energy photon therapy, listed below, have proved valid and accelerators have almost totally replaced orthovoltage units. Initially, it appeared that most of these cited advantages should continue to improve with increasing energy, and there has been an impetus for the production of ever higher megavoltage accelerators. Some of these advantages are reviewed in this paper. Also, recent investigations have indicated increasing diffuseness of the photon beam boundary with increasing energy because of lateral transport of electrons. The impact on treatment planning as a function of energy of the increase in volume dose due to the diffuseness of beam boundaries, "build-down" and "rebuild-up" effects in tissues at cavity and inhomogeneity interfaces, bone absorption, and photoneutron production are discussed. Consideration of the behavior of these parameters indicates that optimum photon energies have been achieved and that the impetus for higher megavoltages is unwarranted for most treatment. For many therapeutic applications, there are major advantages of 4 MV to 8 MV photon beams relative to 60Co gamma rays. For large lesions in the abdomen or pelvis there is an advantage to energies above those provided by 15 MV units. The various considerations above are discussed and summarized as a function of lesion site and megavoltage.

Humans↗

Stereotactic radiosurgery for intracranial arteriovenous malformations using a standard linear accelerator.

We have previously described the development of a technique which utilizes a standard linear accelerator to provide stereotactic, limited field radiation. The radiation is delivered using a modified and carefully calibrated 6 MV linear accelerator. Precise target localization and patient immobilization is achieved using a Brown-Roberts-Wells (BRW) stereotactic head frame which is in place during angiography, CT scanning, and treatment. Seventeen arteriovenous malformations (AVMs) have been treated in 16 patients from February 1986 to July 1988. Single doses of 1500-2500 cGy were delivered using multiple non-coplanar arcs with small, sharp edged x-ray beams to lesions less than 2.7 cm in greatest diameter. The dose distribution from this technique has a very rapid dropoff of dose beyond the target volume. Doses were prescribed at the periphery of the AVMs, typically to the 80-90% isodose line. Eleven of 16 patients have been followed by repeat angiography at least 1 year following treatment. Five of 11 have had complete obliteration of their AVM in 1 year and an additional three patients have achieved complete obliteration by 24 months. There have been no incidences of rebleeding or serious complications in any patient. We conclude that stereotactic radiosurgery using a standard linear accelerator is an effective and safe technique in the treatment of intracranial AVMs and the results compare favorably to the more expensive and elaborate systems that are currently available for stereotactic treatments.

Adolescent↗

A reticle retrofit and dosimetric consideration for a linear accelerator.

PURPOSE: An imperfect reticle system in an accelerator causes uncertainties in source-skin distance (SSD), off-axis distance (OAD), isocenter, and so forth. A reticle was designed and fabricated, and its implications on x-ray and electron beam dosimetry were investigated. METHODS AND MATERIALS: A new reticle frame was dimensioned to fit snugly in the accelerator. The frame was fabricated to carry a pair of adjustable cross wires and to allow the machine operation in the photon and electron modes. The impact of the cross wires on 6 MV photon and 5-10 MeV electron beam parameters such as dose rate (Gy/monitor unit), beam uniformity, surface dose, and so forth, were studied using suitable ion chambers and phantoms. RESULTS: The retrofitted system offered long-term mechanical stability leading to precise SSD, OAD, and isocenter measurements. Changes introduced by the cross wires on the 6 MV photon and 5-10 MeV electron beams are presented. CONCLUSION: Long-term stability of a reticle in an accelerator is important for an accurate patient setup and for making reliable dosimetric measurements. Beam characteristrics have to be studied whenever modifications on a reticle system are made.

Equipment Design↗

Impact-induced intracranial pressure caused by an accelerated motion of the head or by skull deformation; an experimental study using physical models of the head and neck, and ones of the skull.

An impact incurred by the movable head may bring about a change in intracranial pressure and this change may play an important part in the occurrence of the cerebral contusion. We have carried out the following experiments to determine whether the intracranial pressure change was attributed to an accelerated motion of the head or to a skull deformation. In the blow experiment in which the head was accelerated, a positive peak in the intracranial pressure was recorded immediately after impact at the impact site and a negative one at a site opposite the impact. In the one in which the skull could be deformed, the intracranial pressure curves at both sites contained harmonics. The modal analysis revealed an inbending in the frontal and occipital regions of the skull and an outbending in the parietal and temporal regions immediately after impact, followed by a reverse deformation. Regarding the intracranial pressure change, positive pressures were recorded in the frontal and occipital regions immediately after impact, followed by a negative one. This study demonstrated that the positive and negative peaks were caused by the accelerated motion of the head, and that the curve of the intracranial pressure changes contained harmonics which were caused by the deformation of the skull.

Acceleration↗

Interstride trunk acceleration variability but not step width variability can differentiate between fit and frail older adults.

Variability of gait may be regarded as a sign of adaptability and thus a requirement for successful locomotion, or as a sign of impaired balance control. In this study we examined the role of step width variability (SWV) and interstride trunk acceleration variability in two groups of fit and frail old people. We investigated the association of these measures and how they differentiated the two groups. We examined 33 fit older adults (mean age 73 years, S.D. 3.3 years) and 32 frail old people (mean age 80 years, S.D. 4.0 years). Subjects performed timed walking at different speeds ranging from very slow to very fast. SWV was measured from footprints. Trunk accelerations were registered by a triaxial accelerometer and interstride trunk acceleration variability assessed by an unbiased autocorrelation procedure. All measures were normalized to a walking speed of 0.9 m/s to avoid the confounding effect of gait speed on speed dependent gait parameters. SWV demonstrated low association with the trunk variability measures, and did not differ between groups. The frail group had lower mediolateral (P=0.015), but higher vertical (P=0.015) and anteroposterior (P<0.02) trunk variability than the fit group. Trunk variability classified 80% of the subjects correctly into their respective group (sensitivity=0.75, specificity=0.85). The findings are compatible with a notion that mediolateral interstride trunk variability represents a different aspect of motor control than variability in the direction of propulsion.

Acceleration↗

Assessment of two-dimensional induced accelerations from measured kinematic and kinetic data.

A simple algorithm is presented to calculate the induced accelerations of body segments in human walking for the sagittal plane. The method essentially consists of setting up 2x4 force equations, 4 moment equations, 2x3 joint constraint equations and two constraints related to the foot-ground interaction. Data needed for the equations are, next to masses and moments of inertia, the positions of ankle, knee and hip. This set of equations is put in the form of an 18x18 matrix or 20x20 matrix, the solution of which can be found by inversion. By applying input vectors related to gravity, to centripetal accelerations or to muscle moments, the 'induced' accelerations and reaction forces related to these inputs can be found separately. The method was tested for walking in one subject. Good agreement was found with published results obtained by much more complicated three-dimensional forward dynamic models.

Acceleration↗

Using induced accelerations to understand knee stability during gait of individuals with muscle weakness.

The purpose of this case series was to quantify the effectiveness of different compensatory strategies used by individuals with muscle weakness to produce knee extension during the stance phase gait. Subjects were three males with less than anti-gravity strength in the quadriceps femoris and a variable pattern of weakness elsewhere in the lower extremity. They walked independently at a self-selected speed without assistive devices. Gait analysis of the pelvis and bilateral lower extremity segments was performed with a six-camera, two force platform motion capture system. Joint angles and net internal moments were computed from the motion data. Induced acceleration analysis was performed to quantify the relative ability of each lower extremity joint moment and gravity to produce knee angular acceleration. Results showed that a variety of adaptive strategies both within and across limbs can control knee position during gait. One subject generated knee extension almost exclusively via the hip extensor moment. Another relied less on the hip extensor moment (39%) and more on the ankle plantar flexor moment (61%) to create knee extension. The third subject used the ipsilateral hip extensor moment (24%) and the contralateral ankle plantar flexor moment (67%) to assist knee extension. The strategy selected by each subject likely was influenced by both their total pattern of impairments and the effectiveness of the available compensations. This case series demonstrates how an induced acceleration analysis can augment a traditional gait analysis to expand and enhance our understanding of compensatory movement control strategies.

Acceleration↗

Criterion validity of 3D trunk accelerations to assess external work and power in able-bodied gait.

Evaluative quantification of gait disorder minimizing time-consuming and cost-intensive laboratory installations remains a challenging task in movement analysis. We examined the criterion validity of global gait mechanics assessed by trunk accelerometry. Eight female and four male volunteer subjects (mean age, 27.5 years; S.D., 5.1 years; weight, 68.7+/-11.3kg; height, 1.74+/-0.08m) without gait dysfunction participated in the study. They walked barefoot over two adjacent force-platforms at self-selected speeds. In addition to ground reaction forces, vertical, anterior-posterior and medio-lateral accelerations of the trunk were simultaneously measured by means of a light tri-axial accelerometer. Mean acceleration cycles of the trunk and the body centre of mass were calculated. Acceleration vectors were integrated twice to obtain velocity and displacement vectors of the trunk and the centre of mass, respectively. Temporal boundaries of right and left functional stance phases were defined by the two intermediate moments between maximum anterior-posterior velocity and minimal vertical displacement. Cross-correlations of the kinematics of the trunk and the centre of mass were determined. External work and corresponding symmetry indicators were computed for both methods. Centre of mass anterior-posterior displacement lagged behind the trunk by 3.5% of the gait cycle. External power correlated highly (r>0.82) between the trunk model and the centre of mass. Work correlated moderately high (r=0.77) between the two methods. Work and power asymmetry indexes correlated moderately high (r>0.64). Our findings suggest that accelerometry has the potential to assess functional kinematics and energy-related outcomes in large cohorts.

Acceleration↗

The effect of swimmer's hand/forearm acceleration on propulsive forces generation using computational fluid dynamics.

Propulsive forces generated by swimmers hand/forearm, have been studied through experimental tests. However, there are serious doubts as to whether forces quantified in this way are accurate enough to be meaningful. In order to solve some experimental problems, some numerical techniques have been proposed using Computational Fluid Dynamics (CFD). The main purpose of the present work was threefold. First, disseminate the use of CFD as a new tool in swimming research. Second, apply the CFD method in the calculation of drag and lift coefficients resulting from the numerical resolution equations of the flow around the swimmers hand/forearm using the steady flow conditions. Third, evaluate the effect of hand/forearm acceleration on drag and lift coefficients. For these purposes three, two-dimensional (2D), models of a right male hand/forearm were studied. A frontal model (theta = 90 degrees, Phi = 90 degrees) and two lateral models, one with the thumb as leading edge (theta = 0 degrees, = 90 degrees), and the other with the small finger as the leading edge (theta = 0 degrees, Phi = 180 degrees). The governing system of equations considered was the incompressible Reynolds averaged Navier-Stokes equations with the standard k-epsilon model. The main results reported that, under the steady-state flow condition, the drag coefficient was the one that contributes more for propulsion, and was almost constant for the whole range of velocities, with a maximum value of 1.16 (Cd = 1.16). This is valid when the orientation of the hand/forearm is plane and the model is perpendicular to the direction of the flow. Under the hand /forearm acceleration condition, the measured values for propulsive forces calculation were approximately 22.5% (54.440 N) higher than the forces produced under the steady flow condition (44.428 N). By the results, pointed out, we can conclude that: (i) CFD can be considered an interesting new approach for hydrodynamic forces calculation on swimming, (ii) the acceleration of hand/forearm provides more propulsion to swimmers, confirming that some unsteady mechanism must be present in swimming propulsion.

Acceleration↗

Comparison of incremental and accelerating protocols of the rotarod test for the assessment of motor deficits in the 6-OHDA model.

The rotarod test, in which animals must balance on a rotating drum, is widely used to assess motor deficit in neurodegenerative disease models in rodents. Performance is measured by the duration that an animal stays on the rod as a function of drum speed. Two different protocols are widely used, incremental fixed speeds or an accelerating protocol, but there is little information on their equivalence or the relative power, reliability and sensitivity of the two protocols. The present study was undertaken to compare the incremental fixed-speed and accelerating rotarod protocols on two different lesions of the ascending forebrain dopamine pathways. Three groups of rats were used, controls, rats with 6-OHDA lesions of nigrostriatal bundle, and rats with terminal 6-OHDA lesions within the striatum. Rats were tested at different time points after the lesion. We report that whereas the incremental protocol is more sensitive to detect the presence of a lesion, the accelerating protocol provides a more discriminative test to correlate motor deficits against lesion size.

Acceleration↗

Vertical ocular responses to constant linear acceleration generated by fore-aft head translation in monkeys.

We examined the vertical linear vestibuloocular reflexes (LVORs) elicited by constant linear acceleration (0-0.5 g for >95 ms) during transient fore-aft translation in three monkeys. In the dark condition, small but consistent downward ocular responses to forward translation were observed (latencies >41 ms) when the initial vertical eye positions were at 0 degrees , although eye movements following backward translation were inconsistent among animals. These downward ocular responses showed the following three characteristics: they were independent of vertical gaze eccentricities, their magnitudes were almost proportional to the forward acceleration, and they were reduced by the large-field (not the spot) visual information. These characteristics revealed that the downward ocular responses to forward translation were the tilt LVORs. In addition, we recognized that the translational LVOR, which depended on vertical gaze eccentricities, was working at the same time. Our data suggest that constant linear acceleration during forward translation evokes the tilt LVOR, as well as the illusory tilting perception.

Acceleration↗

A virtual-accelerator-based verification of a Monte Carlo dose calculation algorithm for electron beam treatment planning in clinical situations.

BACKGROUND AND PURPOSE: The introduction of Monte Carlo (MC) techniques for treatment planning and also for verification purposes will have considerable impact on the radiation therapy planning process. The aim of this work was to use a virtual accelerator to study the performance of a MC-based electron dose calculation algorithm, implemented in a commercial treatment planning system. METHODS: The performance in phantoms containing air and bone as well as in patient-specific geometries (thorax wall, nose, parotid gland and spinal cord) has been studied. RESULTS: The agreement between the virtual accelerator and the MC dose calculation algorithm is generally very good. A gamma-evaluation with criteria of 0.03 Gy/3 mm (per Gy at the depth of maximum dose) shows that, even for the worst cases, only a small volume of about 1.5% has gamma>1.0. In the worst case, with the 0.02 Gy/2 mm criteria, about 92% of the volume receiving more than 0.85 Gy per 100 monitor units (MU) has gamma-values <1.0. The corresponding value for the volume receiving more than 0.10 Gy/100 MU is about 98%. For the 18 MeV spinal-cord case, where a 6 x 20 cm2 insert is used, the TPS underestimates the dose outside the primary field due to inadequate modelling of the insert. CONCLUSION: The possibility of dose calculations in typical patient cases makes the virtual accelerator a powerful tool for validation and evaluation of dose calculation algorithms present in treatment planning systems.

Algorithms↗

Linear accelerator thalamotomy.

BACKGROUND: The capability of performing functional radiosurgery lesions in the brain using a dedicated linear accelerator (LINAC) have not yet been demonstrated. This study evaluates modern LINAC technology for the creation of a sharp, small and functionally eloquent lesion in the thalamus. METHODS: Three patients underwent thalamotomy using a dedicated linear accelerator to radiosurgery, 2 females and 1 male, ages were 52, 53, and 73 years. Two patients presented with unilateral poststroke central pain and 1 with unilateral upper extremity pain secondary to metastatic infiltration of the brachial plexus. Maximal doses varied from 150 to 200 Gy, delivered by a 5-mm diameter collimator and 5 to 8 noncoplanar arcs evenly distributed. RESULTS: All patients gained substantial relief of their pain. They were able to reduce their medications and improve their activity levels. The patient with end-stage metastatic disease died of his malignancy 2 weeks after the treatment. One patient presented with recurrence of the pain 4 months after the treatment. No clinical complications were noticed. CONCLUSIONS: A dedicated linear accelerator is able to perform a precise and circumscribed lesion in the thalamus for pain control. Moreover, it proved to be safe, because no complications were observed. For patients using chronic anticoagulant therapy or with severe disabilities caused by cardiac, pulmonary or malignant diseases, this technique represents an alternative of treatment to radiofrequency thalamotomy.

Aged↗

Acceleration of fetal head induced by vibration of maternal abdominal wall in sheep.

OBJECTIVE: The human body is often exposed to significant vibration stress in the workplace, at home, and during recreational activities. The current study was designed to evaluate whether low- to midfrequency vibrations present at the extraabdominal wall would be attenuated across this wall and what the levels of exposure would be once these vibrations reached the fetal head. STUDY DESIGN: Four pregnant sheep were instrumented with acceleration transducers to obtain acceleration levels at the extraabdominal and intraabdominal walls and at the fetal head. Sine-wave vibration stimulation was applied over a frequency range of 3 to 150 Hz at a constant acceleration level of 2.5 m/sec2 (root-mean-square). RESULTS: Vibration of the extraabdominal wall resulted in a frequency-dependent rise in vibration levels at the intraabdominal wall, from 4% to 140% of the input level. At the fetal head a broad peak in response was noted between 6 and 12 Hz, but the overall levels never exceeded 4% of the input level. CONCLUSION: Fetal exposure to localized vibratory stimulation of the maternal abdomen is maximal in the range of 6 to 12 Hz.

Abdominal Muscles↗