PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65Linked to original sources

A microfluidic device with an integrated waveguide beam splitter for velocity measurements of flowing particles by Fourier transformation.

A microfabricated capillary electrophoresis device for velocity measurements of flowing particles is presented. It consists of a 1 x 128 planar waveguide beam splitter monolithically integrated with an electrically insulated fluidic channel network for fluorescence excitation at multiple points. Stray light rejection structures are included in order to suppress unwanted light between the detection regions. The emission pattern of particles passing the detection region was collected by a photomultiplier tube that was placed in close proximity to the channel, thereby avoiding the use of transfer optics. The integrated planar waveguide beam splitter was, furthermore, permanently connected to the light source by a glued-on optical fiber, to achieve a robust and alignment-free operation of the system. The velocity was measured using a Fourier transformation with a Shah function, since the response of the light array was designed to approximate a square profile. Deviations from this response were observed as a result of the multimode nature of the integrated waveguides.

Journal Article↗

Fabrication of poly(methyl methacrylate) microfluidic chips by atmospheric molding.

A greatly simplified method for fabricating poly(methyl methacrylate) (PMMA) separation microchips is introduced. The new protocol relies on UV-initiated polymerization of the monomer solution in an open mold under ambient pressure. Silicon microstructures are transferred to the polymer substrate by molding a methyl methacrylate solution in a sandwich (silicon master/Teflon spacer/glass plate) mold. The chips are subsequently assembled by thermal sealing of the channel and cover plates. The new fabrication method obviates the need for specialized replication equipment and reduces the complexity of prototyping and manufacturing. Variables of the fabrication process were assessed and optimized. The new method compares favorably with common fabrication techniques, yielding high-quality devices with well-defined channel and injection-cross structures, and highly smoothed surfaces. Nearly 100 PMMA chips were replicated using a single silicon master, with high chip-to-chip reproducibility (relative standard deviations of 1.5 and 4.7% for the widths and depths of the replicated channels, respectively). The relatively high EOF value of the new chips (2.12 x 10(-4) cm(2) x V(-1) x s(-1)) indicates that the UV polymerization process increases the surface charge and hence enhances the fluidic transport. The attractive performance of the new CE microchips has been demonstrated in connection with end-column amperometric and contactless-conductivity detection schemes. While the new approach is demonstrated in connection with PMMA microchips, it could be applied to other materials that undergo light-initiated polymerization. The new approach brings significant simplification of the process of fabricating PMMA devices and should lead to a widespread low-cost production of high-quality separation microchips.

Journal Article↗

Monitoring food quality by microfluidic electrophoresis, gas chromatography, and mass spectrometry techniques: effects of aquaculture on the sea bass (Dicentrarchus labrax).

Monitoring food quality is a critical task for analytical chemistry and an important way to preserve human health. Fish is a valuable source of highly digestible proteins and contains large amounts of polyunsaturated fatty acids and fat-soluble vitamins. Since the world's wild fish stocks are limited, farmed fish is nowadays proposed as an alternative to consumers. It is now emerging that the fish muscle protein content is assuming great importance from an aquaculture perspective. Many data have been collected on the physiology and biochemistry of fish muscle, but few proteomic studies are available on farmed fish. Application of proteomics to aquaculture may play a key role in the development of new farming strategies. In this paper, a proteomic approach based on SDS-PAGE separation of proteins, in situ protein hydrolysis, de novo sequencing of peptides by MALDI and ESI MS(2), protein identification, and relative quantitation of protein by denaturing capillary electrophoresis was coupled with the determination of fatty acids and metal ions content by GM-MS and ICPMS in farmed and wild sea bass filet. Our results show that aquaculture could induce significant chemical and biochemical differences in fish muscle that may have an impact on food quality.

Amino Acid Sequence↗

Carrier medium exchange through ultrasonic particle switching in microfluidic channels.

This paper describes a method, utilizing acoustic force manipulation of suspended particles, in which particles in a laminar flow microchannel are continuously translated from one medium to another with virtually no mixing of the two media. During the study, 5-microm polyamide spheres suspended in distilled water, spiked (contaminated) with Evans blue, were switched over to clean distilled water. More than 95% of the polyamide spheres could be collected in the clean medium while removing up to 95% of the contaminant. Preliminary experiments to use this method to wash blood were performed. Red blood cells were switched from blood, spiked with Evans blue, to clean blood plasma. At least 95% of the red blood cells (bovine blood) could be collected in clean blood plasma while up to 98% of the contaminant was removed. The obtained results indicate that the presented method can be used as a generic method for particle washing and, more specifically, be applied for both intraoperative and postoperative blood washing.

Journal Article↗

Sol-gel modified poly(dimethylsiloxane) microfluidic devices with high electroosmotic mobilities and hydrophilic channel wall characteristics.

Using a sol-gel method, we have fabricated poly(dimethylsiloxane) (PDMS) microchips with SiO2 particles homogeneously distributed within the PDMS polymer matrix. These particles are approximately 10 nm in diameter. To fabricate such devices, PDMS (Sylgard 184) was cast against SU-8 molds. After curing, the chips were carefully removed from the mold and sealed against flat, cured pieces of PDMS to form enclosed channel manifolds. These chips were then solvated in tetraethyl orthosilicate (TEOS), causing them to expand. Subsequently, the chips were placed in an aqueous solution containing 2.8% ethylamine and heated to form nanometer-sized SiO2 particles within the cross-linked PDMS polymer. The water contact angle for the PDMS-SiO2 chips was approximately 90.2 degrees compared to a water contact angle for Sylgard 184 of approximately 108.5 degrees . More importantly, the SiO2 modified PDMS chips showed no rhodamine B absorption after 4 h, indicating a substantially more hydrophilic and nonabsorptive surface than native PDMS. Initial electroosmotic mobilities (EOM) of (8.3+/-0.2)x10(-4) cm2/(V.s) (RSD=2.6% (RSD is relative standard deviation); n=10) were measured. This value was approximately twice that of native Sylgard 184 PDMS chips (4.21+/-0.09)x10(-4) cm2/(V.s) (RSD=2.2%; n=10) and 55% greater than glass chips (5.3+/-0.4)x10(-4) cm2/(V.s) (RSD=7.7%; n=5). After 60 days of dry storage, the EOM was (7.6+/-0.3)x10(-4) cm2/(V.s) (RSD=3.9%; n=3), a decrease of only 8% below that of the initially measured value. Separations performed on these devices generated 80,000-100,000 theoretical plates in 6-14 s for both tetramethylrhodamine succidimidyl ester and fluorescein-5-isothiocyanate derivatized amino acids. The separation distance was 3.5 cm. Plots of peak variance vs analyte migration times gave diffusion coefficients which indicate that the separation efficiencies are within 15% of the diffusion limit.

Journal Article↗

Microfabricated filters for microfluidic analytical systems.

Solvent and reagent filters were micromachined into quartz wafers using deep reactive ion etching to create a network of intersecting 1.5 x 10 microns channels. When placed at the bottom of reservoirs with a side exit, this channel network behaved as a lateral percolation filter composed of an array of cubelike structures one layer deep. Flow through these filters was driven by electroosmotic flow (EOF). Silanol groups at the walls of channels in the network provided the requisite charge to trigger EOF when voltage was applied laterally to the filter. Adsorption of cationic proteins in this silanol-rich matrix was controlled by the application of a polyacrylamide coating prepared by bonding N-hydroxysuccinimide (NHS)-activated poly(acrylic acid) to (gamma-aminopropyl)silane-derivatized filters. Subsequent reaction of residual NHS groups in the coating with 2-(2-aminoethoxy)ethanol provided channels of low charge density and adsorptivity. These lateral percolation filters were shown to be efficacious in filtering solvents containing a variety of particulate materials, ranging from dust to cells.

Adsorption↗

Flame hydrolysis deposition of glass on silicon for the integration of optical and microfluidic devices

Flame hydrolysis deposition (FHD) of glasses has previously found applications in the telecommunications industry. This paper shows how the technology can be used to deposit silica with different refractive indices and thereby produce low-loss planar waveguides for use in analytical applications. We also show that the glasses can be patterned using a new reactive ion etch and sealed using a modification of anodic bonding, such that the resulting microstructures can be readily incorporated within a lithographically defined "chip", integrating both optical and fluidic circuitry on the same device. In the example described in this paper, waveguides, analytical microtiter chambers and fluidic capillary channels, with the necessary high aspect ratio features (and with depths up to 40 microm) were all produced in glass, using the appropriate deposition and etching technologies. The performance of the chip was assessed in the framework of a low-volume fluorescence assay, using waveguides to address miniaturized microtiter chambers with volumes of 230 and 570 pL. Devices featuring different optical detection configurations, including both in-line and orthogonal waveguide geometries, were fabricated. In the optimal configuration, the experimental detection limit was determined as ca. 20 pM (equivalent to 10 zmol) of a cyanine fluorophore, Cy5. The applicability of the device as a biochip platform was further illustrated by analytical measurements on fluorescently labeled oligodeoxynucleotides.

Journal Article↗

Integrated system for rapid PCR-based DNA analysis in microfluidic devices.

An integrated system for rapid PCR-based analysis on a microchip has been demonstrated. The system couples a compact thermal cycling assembly based on dual Peltier thermoelectric elements with a microchip gel electrophoresis platform. This configuration allows fast (approximately 1 min/ cycle) and efficient DNA amplification on-chip followed by electrophoretic sizing and detection on the same chip. An on-chip DNA concentration technique has been incorporated into the system to further reduce analysis time by decreasing the number of thermal cycles required. The concentration injection scheme enables detection of PCR products after performing as few as 10 thermal cycles, with a total analysis time of less than 20 min. The starting template copy number was less than 15 per injection volume.

DNA↗

Vibration-actuated drop motion on surfaces for batch microfluidic processes.

When a liquid drop is subjected to an asymmetric lateral vibration on a nonwettable surface, a net inertial force acting on the drop causes it to move. The direction and velocity of the drop motion are related to the shape, frequency, and amplitude of vibration, as well as the natural harmonics of the drop oscillation. Aqueous drops can be propelled through fluidic networks connecting various unit operations in order to carry out batch processing at the miniature scale. We illustrate the integration of several unit operations on a chip: drop transport, mixing, and thermal cycling, which are precursor steps to carrying out advanced biological processes at microscale, including cell sorting, polymerase chain reaction, and DNA hybridization.

Journal Article↗

Surface engineering of poly(dimethylsiloxane) microfluidic devices using transition metal sol-gel chemistry.

We report the coating of poly(dimethylsiloxane) (PDMS) microchannels using transition metal sol-gel chemistry and the subsequent characterization of the coatings. The channels were created using soft polymer lithography, and three metal alkoxide sol-gel precursors were investigated, titanium isopropoxide, zirconium isopropoxide, and vanadium triisobutoxide oxide. The metal alkoxides were diffused into the sidewalls of a PDMS channel and subsequently hydrolyzed using water vapor. This procedure resulted in the formation of durable metal oxide surfaces of titania, zirconia, or vanadia. The resulting surfaces were characterized using contact angle, X-ray photoelectron spectroscopy (XPS), Raman, transmission electron microscopy (TEM), scanning electron microscopy (SEM), atomic force microscopy (AFM), and electroosmotic mobility (EOM) measurements. All of the metal oxide-modified PDMS surfaces were significantly more hydrophilic than native PDMS. Contact angles for the coatings were 90 degrees for PDMS-ZrO2, 61 degrees for PDMS-TiO2, and 19 degrees for PDMS-vanadia. XPS showed the presence of titania, zirconia, and vanadia on the PDMS surface. XPS spectra also showed no chemical modification of the PDMS after the in situ deposition of the particles either in the Si-O, Si-C, or C-H bonds of the PDMS. The particles deposited in situ were imaged with TEM and were found to be homogeneously distributed throughout the bulk of the PDMS. EOM measurements of the inorganic coatings were stable over a period of at least 95 days. Both cathodic and anodic EOMs could be generated depending upon buffer pH used. The points of net zero charge for PDMS-TiO2, PDMS-ZrO2, and PDMS-vanadia channels were calculated using EOM versus pH measurements and were found to be 4.1 +/- 0.25, 6.1 +/- 0.2, and 7.0 +/- 0.43, respectively. In addition to modifying PDMS channels with inorganic coatings, these inorganic coatings were derivatized with various organic functionalities including oligoethylene oxide (OEO), amino, perfluoro, or mercapto groups using silane chemistry. Contact angle measurements for perfluoro, mercapto, amino, and OEO-coated surfaces yielded contact angles of 120 degrees , 76 degrees , 45 degrees , and 23 degrees , respectively. These contact angles did not change over the period of 95 days. OEO-coated channels reduced the EOM by 50% from native PDMS-TiO2 to 0.9 +/- 0.05 x 10(-4) cm2/V.s (n = 5, 5.5% RSD).

Journal Article↗

Stable modification of PDMS surface properties by plasma polymerization: application to the formation of double emulsions in microfluidic systems.

We describe a method based on plasma polymerization for the modification and control of the surface properties of poly(dimethylsiloxane) (PDMS) surfaces. By depositing plasma polymerized acrylic acid coatings on PDMS, we succeeded to fabricate stable (several days) hydrophilic and patterned hydrophobic/hydrophilic surfaces. We used this approach to generate direct and (for the first time in this material) double emulsions in PDMS microchannels.

Journal Article↗

Embedded template-assisted fabrication of complex microchannels in PDMS and design of a microfluidic adhesive.

In this paper, we describe a novel method for fabricating 2-D and 3-D microchannel patterns in a flexible platform of cross-linked poly(dimethylsiloxane) (PDMS). Here, a slender nylon thread formed into different 2-D and 3-D shapes is used as a template that is embedded inside a block of cross-linked PDMS. The cross-linked network is then allowed to swell in a suitable solvent that swells the network selectively but leaves the nylon thread unaltered. The thread is then gently removed from the swollen network leaving behind a microchannel. Channels of a variety of topologically complex orientations like knots, helices, super-helices, and channels of a variety of cross-sections can be generated using this simple method. Finally, we have presented an application by generating inside layers of adhesive in these microchannels, which are observed to enhance the adhesion strength significantly.

Journal Article↗

Strategy for allosteric analysis based on protein-patterned stationary phase in microfluidic chip.

An effective method is presented for the on-chip analysis of chiral interactions with a successful depression of nonspecific adsorption. The alumina gel-derived protein network on poly(methyl methacrylate) (PMMA) microchannel was explored to form a protein-stationary phase and then used to carry out electrophoresis for fast enantioseparation coupled with electrochemical detection. On the basis of the chemical modification of a synthesized copolymer containing silane-functionalized scaffold, alumina sol-gel could react readily with the silane groups and form steady microstructure on the chip surface achieving the encapsulation of functional biomolecules. Compared with the native PMMA microchannels, the modified surfaces exhibited much better wettability, more stable and enhanced electroosmotic mobility, and less nonspecific adsorption. The water contact angle and EOF of alumina-gel-derived PMMA substrate were 22 degrees and 4.3 x 10(-4) cm(2) V(-1) s(-1), compared to those of 73 degrees and 1.9 x 10(-4) cm(2) V(-1) s(-1) from the untreated one, respectively. Bovine serum albumin, acting as a target protein, could be stably and homogeneously immobilized in the modified PMMA microchannel to fabricate a protein-stationary phase. Under a mild condition, D- and L-tryptophan were efficiently separated with a resolution of 1.57. The as-prepared microchip can perform chiral separations within short time, indicating that the general protocol has the potential to provide a platform for high throughput screening of enantiomer candidates such as those biochemical drugs with protein targets and the research of receptor interactions.

Adsorption↗

Wavelet transform for Shah convolution velocity measurements of single particles and solutes in a microfluidic chip.

Wavelet transform analysis is applied to determine the speed of fluorescent polystyrene microspheres and fluorescent solutes in a microchip. The data analysed consist of the periodical signal (Shah convolution) obtained when fluorescent particles or solute plugs move in a channel that is covered with a chromium grid pattern. This setup converts velocity into a (fluorescence emission) frequency, and previous analyses therefore used Fourier transform to extract the frequency information. In this paper it is shown that wavelet transform has some advantages over Fourier transform. With wavelet transform, time information can be obtained in addition to frequency information. Thus the speed of individual particles was determined together with their moments of appearance and disappearance in the system. With solutes small changes of velocity during the analysis were detected, and an improvement in peak frequency resolution was obtained.

Journal Article↗