PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “RIGIDITY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65Linked to original sources

Binding of rigid dendritic ruthenium complexes to carbon nanotubes.

Single-walled carbon nanotubes (SWNTs) bind strongly to rigid ruthenium metallodendrimers. High valence ions effectively coagulate these nanotubes from stable dispersions in N,N-dimethylforamide. While ruthenium salts and small [Ru(diimine)(3)](2+) complexes also coagulate the nanotubes, they require much higher concentrations and are easily extracted from the nanotubes with acetonitrile. Enantiomerically pure ruthenium metallodendrimer [Lambda(6)Delta(3)Lambda-Ru(10)](20+)[PF(6)(-)](20) is shown to bind strongly and specifically to the SWNTs. Most of the nanotube's ends are functionalized with this large (5.8 nm), optically active, rigid supramolecular complex. We study the binding capacity with UV-vis and atomic absorption spectroscopy. Imaging the functionalized nanotubes with scanning electron microscopy and atomic force microscopy (AFM) yields direct confirmation of end functionalization. Statistical analysis of the AFM images shows the morphology of the functionalized ends is consistent with the nanotubes binding to one of the endo- or exoreceptors around the dendrimer. Implications of these results toward efficient nanomanufacturing of carbon nanotube devices are discussed.

Journal Article↗

Pyrene-terminated phenylenethynylene rigid linkers anchored to metal oxide nanoparticles.

Phenylenethynylene (PE) rigid linkers (para and meta) were used to anchor pyrene to the surface of TiO2 (anatase) and ZrO2 nanoparticle thin films through the two COOH groups of an isophthalic acid (Ipa) unit. Four chromophore-linker models were studied in solution and bound. Two are novel meta-pyrene-PE linker systems: dimethyl 5-(3-(1-pyrenylethynyl)phenylethynyl)-isophthalate, carrying one pyrene, and dimethyl 5-(bis-3,5-(1-pyrenylethynyl)phenylethynyl)-isophthalate, carrying two. These were compared with para rigid-rods dimethyl 5-(1-pyrenylethynyl)isophthalate and dimethyl 5-(4-(1-pyrenylethynyl)phenylethynyl)-isophthalate, each carrying one pyrene but varying in length. The length of the PE linkers and the para or meta substitution influence the photophysical properties of the compounds. The extinction coefficient increased, and the long wavelength absorbance of the pyrene chromophore was shifted to the red with increasing conjugation. Compared to unsubstituted pyrene, the pyrene-linker systems were characterized by short fluorescence lifetimes (tau approximately 2 ns in tetrahydrofuran solutions), but quantum yields were close to unity. ZINDO/S CI calculations attribute this effect to a switching in the order of the two lowest-lying singlet states of pyrene. High surface coverages, approximately 10(-8) mol/cm2, and carboxylate binding modes on nanostructured TiO2 films were obtained in all cases. The appearance of a pyrene excimer emission on ZrO2, an insulator, indicates that the pyrene-linker system is closely packed (Py-Py < 4 A) on the surface. The fluorescence emission on TiO2 was completely quenched, consistent with quantitative and rapid electron injection into the semiconductor indicating that the pyrene excimer acts as a sensitizer. Photoelectrochemical studies in regenerative solar cells with I3-/I- as the redox mediator indicated near-quantitative conversion of absorbed photons into an electrical current.

Adsorption↗

Rigid sphere molecular model enables an assessment of the pore curvature effect upon realistic evaluations of surface areas of mesoporous and microporous materials.

A gas adsorption rigid spheres model (RSM) was incorporated into the CPSM model (corrugated pore structure model) to correlate the pore surface areas obtained from the BET and CPSM methods. The latter is a method simulating the gas sorption hysteresis loop and enables the evaluation of surface areas S(CPSM) through the integration of the pertinent pore size distributions. Thus, S(CPSM) values are inherently influenced by pore curvature. The new CPSM-RSM version estimates surface areas S(CPSMfs) that are independent of pore curvature and can be compared with the pertinent S(BET) values. The RSM exploits the fact that a curved pore surface accommodates fewer molecules, assumed to behave as rigid spheres, than an equal flat one. Thus, the RSM accounts for a higher molecular surface coverage Ac (nm2/molec.) in pores with marked curvature than that (i.e., Af) on a flat surface. The ratio Ac/Af for nitrogen adsorbed on single pore sizes varies in the range Ac/Af = 1.44-1.03 for pore sizes D = 1.5-15 nm, respectively. Also for D = 1.5-5.0 nm the S(CPSMfs) and S(BET) values are lower by approximately 10-45% than the S(CPSM) estimates. From the application of the CPSM-RSM model on several porous materials exhibiting all known types of sorption hysteresis loops, it was confirmed that S(BET) approximately S(CPSMfs) (+/-5%) and (S(CPSM) - S(BET))/S(BET) = 3-68% for the materials examined. In conclusion, the BET method may produce quite conservative surface area estimates for materials exhibiting pore structures with appreciable pore curvature, whereas the CPSM-RSM model can reliably predict both S(CPSM) and S(CPSMfs) = S(BET) values.

Journal Article↗

Enantiodifferentiating photocyclodimerization of 2-anthracenecarboxylic acid mediated by gamma-cyclodextrins with a flexible or rigid cap.

[reaction: see text] A series of modified gamma-cyclodextrins (CDs) with a flexible or rigid cap, synthesized and used as chiral supramolecular hosts for mediating the enantiodifferentiating photocyclodimerization of 2-anthracenecarboxylic acid, significantly improved the chemical and optical yields of chiral head-to-head cyclodimer 3, while the gamma-CD with a rigid cap dramatically inverted the stereochemical outcomes and further improved the enantioselectivities of both head-to-tail and head-to-head dimers 2 and 3.

Anthracenes↗

Design evaluation of commonly used rigid and levering laryngoscope blades.

BACKGROUND: The shape of a laryngoscope blade affects the exposition of the larynx. This study evaluates and compares some rigid and levering blade designs based on previous investigative X-ray laryngoscopic studies. METHODS: Five rigid laryngoscope blades (Miller #3, Standard Macintosh #3, Classical Macintosh #4 and English-Macintosh #3 and #4) and two levering laryngoscope blades (McCoy in neutral and maximally elevated positions and Flexiblade in three basic positions: straight, neutral, and maximally curved) were evaluated. This study assesses two parameters derived from the depth of insertion: the eye line deviation from the ideal straight view line to the vocal cords, and the space occupied by the blade behind the mandible, which affects the contact of the blade tip with the base of the tongue. RESULTS: The best results on larynx exposition were produced by the English-Macintosh #4 at all insertion depths between 5 and 14 cm. It surpassed the Classical Macintosh #4 and both the English and Standard Macintosh #3. Although the Miller and the Flexiblade in a straight position afford a nearly ideal view line, both blades reduce the space reserved for the tongue behind the mandible. The McCoy with its tip maximally elevated provides limited view, while activation of the Flexiblade provides various ranges of larynx exposition. CONCLUSION: The difference in shape and design of Macintosh blades affects their performance. The distal portion of a large-sized curved blade is more effective than the full length of a shorter blade. The #4 English Macintosh is a better choice for routine clinical use. The Flexiblade performs as a multiblade device and can therefore be used for both routine and difficult intubations.

Equipment Design↗

A new technique for rigid gas permeable contact lens fitting following penetrating keratoplasty.

PURPOSE: To evaluate a new, rigid gas permeable contact lens fitting technique following penetrating keratoplasty. METHODS: For the correction of postoperative anisometropia or astigmatism, a rigid gas permeable, tetra-curve contact lens with an overall diameter of 12.0 mm and a back optic zone diameter of 8.5 mm was fitted in 36 eyes of 33 patients, 7 months after penetrating keratoplasty. The contact lens back optic zone radius was selected using the videokeratography values over the elevated edges of the transplant wound (with the sutures in place). Graft clarity, visual outcome, and corneal topography were evaluated up to 3 years after surgery at intervals of 6 months. RESULTS: Throughout the follow-up period (range 6-36, mean 19.3+/-sd 11.8 months), all grafts remained clear. Mean contact lens daily wearing time averaged 13.6 (+/- sd 4.7) hours. Mean best-corrected visual acuity improved from +0.36 (+/- sd 0.18) LogMAR with spectacles to +0.11 (+/- sd 0.11) LogMAR with contact lenses (p < 0.0001). One patient was excluded from the study due to a lack of motivation and one had an adverse reaction to the stitches. CONCLUSIONS: To improve the visual performance following penetrating keratoplasty, the described fitting technique, guided by videokeratography, eased selection of the back optic zone radius of the initial trial lens. The large diameter contact lenses with a tetra-curve design were well tolerated in all patients for more than 13 hours daily.

Adult↗

Rigidity in cinema seen from the front row, side aisle.

Pictures and cinema seen at a slant present the optics of virtual objects that are distorted and inconsistent with their real counterparts. In particular, it should not be possible for moving objects on slanted film and television screens to be seen as rigid, at least according to rules of linear perspective. Previous approaches to this problem have suggested that some process (perhaps cognitive) rectifies the optics of objects in slanted pictures to derive true shape and preserve shape constancy. The means for this rectification is usually thought to be based on recovery of true screen slant. In three experiments I show that this account is unnecessary and insufficient to explain the perception of rotating, rectangular objects in slanted cinema. I present data in favor of an alternate view, one in which the information is sufficient for perceivers to determine rigidity in an object on slanted screens, at least for parallel projections. In the human visual system, local measurements of objects are apparently made according to projective geometry; in those measurements, small amounts of certain distortions in projection are tolerated. Stimuli that appear nonrigid are ones that violate certain local principles, known as Perkins's laws, of projections of rectangular solids.

Humans↗

Nucleotide rigidity.

It is show that in aqueous solution the backbone conformation of adenosine is as much flexible as that of 3'-AMP, 5'-AMP and 3', 5'-ADP indicating that nucleotides are not any more rigid than nucleosides. The flexible conformation of the monomeric components is conserved in the nucleotidyl units of destacked ApA, ApApA and poly(A), but it is not conserved in base stacked conditions. The findings are extended to guanosine, uridine and cytidine systems. It is projected that in aqueous solution, conformations of the individual nucleotidyl units of yeast tRNAhe are confined to the classically stable domains in the base stacked region and non-rigid flexible structures populate in the unstacked region comprising D16, D17, G20, U47 and A76.

Adenine Nucleotides↗

The generic enhancement of photochromic dye switching speeds in a rigid polymer matrix.

The switching or isomerization speed of photochromic dyes in a rigid polymeric matrix (such as an ophthalmic lens) is generally significantly slower than that observed in the mobile environment of a solution. Here we describe that the attachment of flexible oligomers having a low glass-transition temperature-such as poly(dimethylsiloxane)-to photochromic dyes greatly increases their switching speeds in a rigid polymer matrix. The greatest impact was observed in the thermal fade parameters T(1/2) and T(3/4)-the times it takes for the optical density to reduce by half and three quarters of the initial optical density of the coloured state-which were reduced by 40-95% and 60-99% respectively for spirooxazines, chromenes and an azo dye in a host polymer with a glass-transition temperature of 120 degrees C. The method does not alter the electronic nature of the dyes but simply protects them from the host matrix and provides greater molecular mobility for the switching process. In addition to ophthalmic lenses, the generic nature of the method may find further utility in data recording or optical switching.

Circular Dichroism↗

Supramolecular barrels from amphiphilic rigid-flexible macrocycles.

Precise control of supramolecular objects requires the rational design of molecular components, because the information determining their specific assembly should be encoded in their molecular architecture. In this context, diverse self-assembling molecules including liquid crystals, dendrimers, block copolymers, hydrogen-bonded complexes and rigid macrocycles are being created as a means of manipulating supramolecular structure. Incorporation of a stiff rod-like building block into an amphiphilic molecular architecture leads to another class of self-assembling molecules. Aggregation of rod building blocks can generate various nanoscale objects including bundles, ribbons, tubules and vesicles, depending on the molecular structure and/or the presence of a selective solvent. We present here an unusual example of supramolecular barrels in the solid and in aqueous solution, based on the self-assembly of amphiphilic rigid-flexible macrocycles driven by non-covalent interactions. Preliminary experiments show that these amphiphilic macrocycles are membrane-active. The amphiphilic macrocycles might thus lead to an excellent model system for exploring biological processes in supramolecular materials.

Journal Article↗

The use of cantilevered, adhesively retained bridges with enhanced rigidity.

Adhesively retained bridges replacing missing posterior teeth are reported to be less successful than those used to replace anterior teeth. This is due in part to the increased occlusal loading in the posterior region and inadequate rigidity of the retainers. This report describes the use of minimal preparation cast restorations incorporating an 'occlusal strut' to improve the rigidity of the retainers used to support pontics replacing upper premolars. The advantages of using intracoronal minimal preparations are discussed.

Adult↗

Are normal hemodynamic responses invariably associated with normal penile rigidity and potency?

The existence and importance of patients with low penile buckling pressure and normal penile hemodynamic status have been recently recognized. We assessed the ratio of inadequate erection for vaginal penetration (low buckling pressure) in patients with normal penile vascular system proved with penile Doppler ultrasonography. A total of 101 patients with normal penile vascular status were retrospectively scrutinized dependent on penile axial rigidity (buckling pressure). Ninety patients had sufficient penile axial rigidity (> or = 550 g) whereas in the remaining 11 patients (11%) inadequate penile buckling pressure for vaginal penetration (< 550 g) was determined. Penile geometric and mechanical properties should not be overlooked during the evaluation of penile vascular system lest the patient be incorrectly diagnosed as having psychogenic impotence.

Adult↗

Association between International Index of Erectile Function and axial penile rigidity in patients with erectile dysfunction.

We investigated the association between the International Index of Erectile Function (IIEF) and axial penile rigidity parameters in patients with erectile dysfunction (ED). A total of 516 male patients (491 patients with ED and 25 patients without ED) were assessed using IIEF. Patients were assessed for axial penile rigidity (APR) using a digital inflection rigidometer. Mean age+/-s.d. was 52.4+/-9.9 y. ED was mild in 11.4% of the patients, moderate in 40.1%, and severe in 48.5%. Regarding APR, the following was found: (1) no significant difference between patients who had a mild degree of ED and patients who had no ED (P>0.05); (2) a significant difference between patients with different degrees of ED (P<0.05 for each); (3) a significant association between overall presence of ED and low APR (P<0.05). IIEF score is associated with APR and can differentiate between patients with and without ED.

Adult↗

Nocturnal penile tumescence and rigidity (NPTR) findings in spinal cord injured men with erectile dysfunction.

This prospective study aimed at determining whether nocturnal penile tumescence and rigidity (NPTR) findings correlate to the neurologic disorders in spinal cord injured (SCI) patients suffering from erectile dysfunction (ED). A total of 25 acute SCI male patients with post-traumatic ED underwent neurological, electrophysiological and urodynamic examinations, respectively, as well as NPTR recordings. The mean value for rigidity (R), tumescence (T) and duration (D) during NTPR tests were 83.3%, 3.3 cm, 6.4 min in patients with a complete lesion above the sacral (S2-S4) spinal cord (n=10), 46.1%, 1.6 cm, 5.5 min in patients with a complete lesion involving the sacral metameres (n=5) and 89.8%, 3.8 cm, 29 min in patients with an incomplete suprasacral lesion (n=7). The differences among these groups were statistically significant (P<0.05). Patients with lesions involving both sacral and thoracolumbar spinal cord showed no erections (n=3). We found four NTPR patterns: (1) normal R and T, short D; (2) weak R and T, short D; (3) normal R, T and D; and (4) no erections, which can be assigned to different levels and completeness of spinal cord lesions. Nocturnal erections of normal quality need preservation of thoracolumbar and sacral neuronal control as well as partially intact connections of the spinal erection centres with brain areas responsible for sexual arousal.

Adolescent↗

Reinforced molecular recognition as an alternative to rigid receptors.

In theory, a perfectly rigid receptor will probably be an unbeatable binder. However, rigidity may not be easy to achieve in practice and it is certainly not Nature's method to realise high affinity. In many proteins binding affinity is increased through non-covalent interactions within the protein. Thus there is a considerable incentive to follow Nature's example and start exploring the use of secondary intra-receptor interactions to aid in the binding process. Secondary interactions within a receptor will reinforce host-guest binding when the same conformational rearrangement (or freezing of motion) is required for guest binding as for the formation of the intra-receptor interactions. Introducing secondary interactions will require rather elaborate synthetic receptors to be produced. With the recent developments in dynamic combinatorial chemistry, access to the desired structures should be facilitated. Whether or not this approach will develop into a practical method remains to be established, but even if it does not, efforts along these lines will lead to a better understanding of the complex interplay between molecular recognition, folding and dynamics.

Journal Article↗

Probing the dimensions of semi-rigid inner functionalised U-shaped bis-porphyrin cavities.

The synthesis of a series of open U-shaped bis-porphyrin cavity molecules is described, with bridged bicyclic backbones to confer rigidity, and a pendant substituted aromatic probe unit suspended on the inside of the cavity. The dimensions and flexibility of the bis-zincporphyrin cavity were probed using several different techniques. Initially the molecular ruler concept was employed, using flexible bidentate ligands as guests with a range of possible linear dimensions. Secondly, NMR methods were employed with rigid bidentate ligand guests of fixed lengths, and thirdly diffusion based NMR methods were utilised. The range of inter-porphyrin distances estimated by these methods suggests that these types of open-cavity systems have a surprising degree of flexibility.

Magnetic Resonance Spectroscopy↗

Rigid endosseous implants for orthodontic and orthopedic anchorage.

Clinical rigidity ("osseointegration") was achieved by 94 percent of the titanium implants placed in dog mandibles. All loaded implants remained rigid. Inadvertent impingement on the periodontal ligament and roots of adjacent teeth was uneventful. Microradiographic imaging was more reliable than polarized light microscopy for assessing bone contact at the endosseous interface. Implants with less than 10 percent of the endosseous interface in direct contact with bone successfully resisted a continuous load of 3 N (greater than 300 grams) for 13 weeks.

Acid Etching, Dental↗