PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65Linked to original sources

Development of a biosensor for E. coli based on a flexural plate wave (FPW) transducer.

To fulfill the need for rapid, cost-effective and sensitive methods for the detection of bacteria in medical diagnostics, food technology, biotechnology and environmental monitoring, a development of a bacterial sensor was initiated. Our approach of a biosensor for E. coli is based on an acousto-gravimetric flexural plate wave (FPW) transducer (gravimetric detection limit of less than 6 ng in a 32 microns thick sensitive layer in aqueous media), and an immunoaffinity layer on the transducer membrane for the molecular recognition of the target bacteria. An intermediate layer of covalently coupled poly (acrylic acid) yielded a major reduction of the non-specific binding to the metal surface. Such a biosensor, using antibodies against E. coli K12 and E. coli 15 outer surface antigens, yielded a detection range of 3.0 x 10(5) to 6.2 x 10(7) cells/ml for samples with the corresponding bacteria. To increase the sensitivity further, an amplification method using microspheres coupled with antibodies against E. coli was tested as a sandwich assay, and up to now a five-fold amplification of the signal has been achieved.

Antibodies, Bacterial↗

Development of a biosensor for monitoring of glycerol during alcoholic fermentation.

A biosensor for the measurement of glycerol in FIA was constructed using covalently immobilized glycerokinase and glycerol-3-phosphate oxidase in conjunction with a Pt based hydrogen peroxide probe. Different immobilization strategies have been studied including random and asymmetric immobilization onto a polymeric support and immobilization onto two different membranes. The latter resulted in the best configuration for batch measurement. The most effective configuration for measurement in FIA was the immobilization of glycerokinase in a glass beads reactor coupled with glycerol-3-phosphate oxidase on a preactivated Immobilon AV membrane kept at the electrode surface. Using a 250-microliter injection loop, 3 mmol ATP(Mg+2) in 0.1 M borate buffer pH 8.5 and a flow rate of 0.5 ml/min, a linear response in the 2 x 10(-6)/10(-3) mol/l range and a detection limit of 5 x 10(-7) mol/l were obtained for glycerol. Lifetime of the glycerol-3-phosphate membrane was extended up to 1 month by storage in the working buffer containing 1% DEAE-dextran and 5% lactitol. More than 350 samples can be assayed with this system. The biosensor was used to monitor off-line glycerol production during alcoholic fermentations carried out at different pHs and temperatures.

Biosensing Techniques↗

An immunological interleukine-6 capacitive biosensor using perturbation with a potentiostatic step.

An instrument for potentiostatic capacitance measurements, based on perturbation with a potentiostatic step was used. The capacitive sensor consisted of self-assembled sulfur compounds on gold to which antibodies towards Interleukine 6, Il-6, had been immobilized. The biosensor was part of a potentiostatic three-electrode system with an extra reference electrode. Two different methods using epoxy- or carbodiimide coupling of the polyclonal antibodies were compared. The antigen Il-6 could be detected from 5 x 10(-16) to 5 x 10(-13) M with one immobilization method and to more than 5 x 10(-9) M with the other. No labels were necessary since the binding of the antigen was detected directly. The insulating properties of the different layers of the biosensor were investigated.

Biosensing Techniques↗

Amperometric biosensors based on solid binding matrices applied in food quality monitoring.

Solid binding matrix (SBM) based composite transducers have been used for development of series of multibiosensor systems applicable in various fields. Here we present two hybrid three-channel multibiosensors for simultaneous amperometric operation in food quality control, i.e. glucose/fructose/ethanol multibiosensor, based on glucose oxidase/fructose dehydrogenase/alcohol dehydrogenase surface-modified enzyme electrodes and L-lactate/L-malate/sulfite multibiosensor, based on L-lactate dehydrogenase/L-malate dehydrogenase/sulfite oxidase surface-modified enzyme electrodes. Different parameters have been studied in order to optimize the response of the multibiosensor systems. The multibiosensor showed a good sensitivity, linear range and storage stability. The multibiosensors were used for the determination of glucose, fructose, ethanol, L-lactate, L-malate and sulfite in samples of wine, resulting in a good agreement with data certified by the supplier. Comparison of various designs, surface-modified, bulk-modified and thick-cover, of SBM based biosensors is studied on the example of fructose biosensor.

Biosensing Techniques↗

Detection of digitalis compounds using a surface plasmon resonance-based biosensor.

An automated surface plasmon resonance-based biosensor system has been used to detect endogenous and exogenous digitalis-like factors (EDLF) in the pmolar range in real time. EDLF was purified from umbilical cord blood. EDLF has been suggested to play a role in hypertension and in perinatal adaptation. Highly specific polyclonal anti-ouabain antibodies showed a high affinity binding capacity for ouabain, ouabagenin and strophantidin with an IC50 value of 5 x 10(-10) M, 7.0 x 10(-10) M and 2 x 10(-8) M, respectively. EDLF cross-reacted with antibodies and its concentration in plasma at IC50 was around 50 pmol ouabain equivalent. This study shows the potential usefulness of the biosensor technology for biomolecular interaction analysis. The features of this technology (fully automated, measured in real time, sharpened response) offer several advantages compared with a traditional immunoassay like radioimmunoassay (RIA) in the detection of digitalis compounds in human fluids.

Antibodies↗

Improved operational stability of biosensors based on enzyme-polyelectrolyte complex adsorbed into a porous carbon electrode.

A novel porous active carbon is utilized in order to adsorb the diethylaminoethyl-dextran (DEAE-dextran)-enzyme stabilized complexes, for the construction of highly stable biosensors. The interaction of DEAE-dextran with the examined enzymes increases dramatically the operational stabilization of the sensors, without adverse effects on the enzyme activity. At the same time, the porous active carbon allows for high enzyme loading, good electrical contact and low resistance throughout the sensing element. Glucose oxidase and horseradish peroxidase are used as model enzymes in this study to construct biosensors, with very good reproducibility (less than 5% RSD). As a result, the glucose sensor exhibits very long operational stability (over a period of 5 months), while the hydrogen peroxide sensor retains its initial activity after several weeks.

Biosensing Techniques↗

Biosensor for on-line measurement of bovine progesterone during milking.

Reproductive management is a major financial concern of the dairy industry, with missed estrus detection a main cause of lost income. A biosensor was developed for on-line measurement of progesterone in bovine milk and detection of estrus. The biosensor used an enzyme immunoassay format for molecular recognition, which was developed to run in approximately eight minutes. The sensor was designed to operate on-line in a dairy parlor using microinjection pumps and valves for fluid transport, fiber optics and photodiodes for light measurement, and a control computer for sequencing. Calibration showed a dynamic response between 0.1 and 5 ng/ml progesterone in milk. The reusability of the test well was evaluated. Thiocyanate (0.5 M, pH 5.1) quickly regenerated the antibody surface while maintaining antibody activity for 15-20 cycles, but noise from the residual enzyme limited reusability.

Animals↗

Biosensor for direct determination of organophosphate nerve agents. 1. Potentiometric enzyme electrode.

A potentiometric enzyme electrode for the direct measurement of organophosphate (OP) nerve agents was developed. The basic element of this enzyme electrode was a pH electrode modified with an immobilized organophosphorus hydrolase (OPH) layer formed by cross-linking OPH with bovine serum albumin (BSA) and glutaradehyde. OPH catalyses the hydrolysis of organophosphorus pesticides to release protons, the concentration of which is proportional to the amount of hydrolysed substrate. The sensor signal and response time was optimized with respect to the buffer pH, ionic concentration of buffer, temperature, and units of OPH immobilized using paraoxon as substrate. The best sensitivity and response time were obtained using a sensor constructed with 500 IU of OPH and operating in pH 8.5, 1 mM HEPES buffer. Using these conditions, the biosensor was used to measure as low as 2 microM of paraoxon, ethyl parathion, methyl parathion and diazinon. The biosensor was completely stable for at least one month when stored in pH 8.5, 1 mM HEPES + 100 mM NaCl buffer at 4 degrees C.

Animals↗

Determination of lysine in pharmaceutical samples containing endogenous ammonium ions by using a lysine oxidase biosensor based on an all-solid-state potentiometric ammonium electrode.

A new potentiometric method is proposed to determine lysine in pharmaceutical samples. This method is based on a lysine biosensor consisting of a chemically immobilized lysine oxidase membrane attached to an all-solid-state ammonium electrode. Lysine is degraded in the sensor to release ammonium, which is detected by means of the ammonium electrode. The presence of endogenous ammonium in the samples interferes with these determinations, since the response measured corresponds to the sum of the ammonium generated enzymatically and that present in the sample. This is a general drawback for all biosensors based on the detection of ammonium. Study of samples containing both lysine and ammonium showed that concentration ranges exist in which a near-logarithmic relationship between potentials measured and lysine concentrations is found. Therefore, within these ranges, lysine can be determined by using the standard addition method, with the subsequent data treatment involving an iterative linearization procedure. Results obtained with the proposed potentiometric method are consistent with those given by the standard method for amino acid analysis.

Amino Acid Oxidoreductases↗

Effect of methanol on the interaction of monoclonal antibody with free and immobilized atrazine studied using the resonant mirror-based biosensor.

The interaction of monoclonal anti-atrazine antibody D6F3 with free and immobilized atrazine was studied using the resonant mirror-based optical biosensor system IAsys. The binding of antibody to atrazine immobilized on silanized surface through albumin spacer was studied in the presence of methanol. The highest affinity was observed in 10% methanol, the kinetic equilibrium association constant KA was 1.16 x 10(9) mol-1 l compared to 4.3 x 10(8) mol-1 l determined in water. The surface binding capacity was 2-fold lower in the presence of methanol compared to aqueous buffer solution. The kinetic rate constants were significantly improved with low contents of methanol; the fastest association and slowest dissociation occurred at 5 and 10% methanol, respectively. The formation of immunocomplexes was observed even in the presence of 50% methanol. To avoid possible disturbing effects resulting from the immobilization of atrazine, the interaction of free atrazine and antibody was studied using the competitive procedure. The determined values of KA were 9.35, 0.73 and 410 x 10(6) mol-1 l for interactions carried out in 10, 30 and 50% methanol, respectively. For practical determination of atrazine using this antibody, the content of 10% methanol in the assay mixture seems to be the best choice. Thirty percent methanol resulted in the lowest affinity; 50% methanol provides the highest affinity, but much smaller signal is measured. The affinity biosensor system IAsys appeared to be a suitable, rapid and convenient tool for studies of binding interactions in the presence of organic solvents.

Antibodies, Monoclonal↗

A ferric chloride pre-treatment to prevent calcification of Nafion membrane used for implantable biosensors.

Since the perfluorosulfonated ionomer Nafion, commonly used for the protection of biosensors, experiences calcification in a biological environment, we evaluated the efficacy of preincubating Nafion membranes in a FeCl3 solution to reduce the number of nucleation sites responsible for the growth of the calcium phosphate crystals. Nafion membranes were prepared and divided into two groups. In the first group, the Nafion membranes were pre-incubated in 0.1 M FeCl3 for a 24 h period. In the second group, no pre-incubation took place. All membranes were placed in a culture medium for a period of up to 4 weeks. All membranes were then examined for changes in: (1) their surface topography (using scanning electron microscopy (SEM)); (2) their near surface chemical properties (using energy dispersive X-ray (EDX)); and (3) their permeability to glucose. The membranes that were not pre-incubated in FeCl3 showed significant cracking of the Nafion surface, extensive calcium phosphate deposits and a resulting decrease in permeability. In contrast, the membranes treated with FeCl3 showed almost no cracking, very little calcium phosphate deposits and no change in permeability to glucose. This study demonstrated that FeCl3 significantly reduces calcification of Nafion and thus should help in preserving the in vivo function of implantable biosensors that utilize Nafion in their design.

Biosensing Techniques↗

Array biosensor for detection of biohazards.

A fluorescence-based biosensor has been developed for simultaneous analysis of multiple samples for multiple biohazardous agents. A patterned array of antibodies immobilized on the surface of a planar waveguide is used to capture antigen present in samples; bound analyte is then quantified by means of fluorescent tracer antibodies. Upon excitation of the fluorophore by a small diode laser, a CCD camera detects the pattern of fluorescent antibody:antigen complexes on the waveguide surface. Image analysis software correlates the position of fluorescent signals with the identity of the analyte. This array biosensor has been used to detect toxins, toxoids, and killed or non-pathogenic (vaccine) strains of pathogenic bacteria. Limits of detection in the mid-ng/ml range (toxins and toxoids) and in the 10(3)-10(6) cfu/ml range (bacterial analytes) were achieved with a facile 14-min off-line assay. In addition, a fluidics and imaging system has been developed which allows automated detection of staphylococcal enterotoxin B (SEB) in the low ng/ml range.

Biosensing Techniques↗

The BARC biosensor applied to the detection of biological warfare agents.

The Bead ARray Counter (BARC) is a multi-analyte biosensor that uses DNA hybridization, magnetic microbeads, and giant magnetoresistive (GMR) sensors to detect and identify biological warfare agents. The current prototype is a table-top instrument consisting of a microfabricated chip (solid substrate) with an array of GMR sensors, a chip carrier board with electronics for lock-in detection, a fluidics cell and cartridge, and an electromagnet. DNA probes are patterned onto the solid substrate chip directly above the GMR sensors, and sample analyte containing complementary DNA hybridizes with the probes on the surface. Labeled, micron-sized magnetic beads are then injected that specifically bind to the sample DNA. A magnetic field is applied, removing any beads that are not specifically bound to the surface. The beads remaining on the surface are detected by the GMR sensors, and the intensity and location of the signal indicate the concentration and identity of pathogens present in the sample. The current BARC chip contains a 64-element sensor array, however, with recent advances in magnetoresistive technology, chips with millions of these GMR sensors will soon be commercially available, allowing simultaneous detection of thousands of analytes. Because each GMR sensor is capable of detecting a single magnetic bead, in theory, the BARC biosensor should be able to detect the presence of a single analyte molecule.

Biological Warfare↗

An automated, handheld biosensor for aflatoxin.

A new immunoaffinity fluorometric biosensor has been developed for detecting and quantifying aflatoxins, a family of potent fungi-produced carcinogens that are commonly found in a variety of agriculture products. They have also been cited as a biological agent under weapons development. The handheld, self-contained biosensor is fully automatic, highly sensitive, quick, quantitative, and requires no special storage. Approximately 100 measurements can be made before refurbishment is required, and concentrations from 0.1 parts per billion (ppb) to 50 ppb can be determined in <2 min with a 1 ml sample volume. The device operates on the principles of immunoaffinity for specificity and fluorescence for a quantitative assay. The analytic procedure is flexible so that other chemical and biological analytes could be detected with minor modifications to the current device. Advances in electro-optical components, electronics, and miniaturized fluidics were combined to produce this reliable, small, and versatile instrument.

Aflatoxins↗

Research and development in biosensors.

Progress in biosensors has mainly been made by the improvement of the biological components and the implementation of microsystem technologies. Enzymes are still the most appropriate recognition elements because they combine high chemical specificity and inherent biocatalytic signal amplification. A breakthrough has been achieved in the application of membrane-integrated receptor systems for analyte recognition and signal transduction in biosensors. Sensor integration of RNA aptamers has been initiated, and the performance of fully synthetic molecularly imprinted polymers has been improved.

Antibodies↗

Amperometric biosensors.

Over the past 18 months, our understanding of the chemistry and engineering principles of amperometric biosensors, including bioaffinity sensors, has deepened. In addition, several novel amperometric biosensors have been commercialized and progress has been made in the design of subcutaneous sensors, particularly those for glucose.

Biosensing Techniques↗

Advances in surface plasmon resonance biosensor analysis.

The number and diversity of surface plasmon resonance (SPR) biosensor applications continue to increase. Evolutions in instrument and sensor chip technology, experimental methodology, and data analysis are making it possible to examine a wider variety of biomolecular interactions in greater mechanistic detail. SPR biosensors are poised to make a significant impact in basic research and pharmaceutical discovery.

Animals↗

Sensing performance of protein C immuno-biosensor for biological samples and sensor minimization.

Protein C (PC) is an important anticoagulant and antithrombotic agent in human blood plasma. PC deficiency can result in clotting complications that interfere with oxygen and nutrient transport. A fiber-optic biosensor is being developed to provide real time diagnosis of PC deficiency. The PC sensor was tested to quantify PC level in human plasma. The signal intensity obtained from the plasma sample was 30% of the buffered sample, possibly due to the increased viscosity. The feasibility of monitoring PC level in animal cell culture broth and animal milk was tested. For the cell culture broth, 80% of signal was observed. However, the decrease was consistent over the sensing range. For whole and 1:100 diluted bovine milk, the signals were 60 and 78% of buffered sample, respectively. The biosensor length was reduced from 12.5 to 6 cm with sufficient sensitivity. To increase the sensor reusability, various elution buffers were applied after each sensing. Triethylamine elution buffer provided the best sensor regeneration capability and increased the number of assays from 2.5 to 7 times for 6 cm fibers.

Animals↗