Hydraulic activity of cement mixed with slag from vitrified solid waste incinerator fly ash.

This study investigates the effects of the slag composition on the hydraulic activity in slag blended cement pastes that incorporate synthetic slag prepared by melting CaO-modified municipal solid waste incinerator fly ash. Two types of composition-modified slag were prepared for this study. First, fly ash was mixed with the modifier (CaO) at 5% and 15% (by weight) respectively, resulting in two fly ash mixtures. These mixtures were then melted at 1400 degrees C for 30 minutes and milled to produce two types of slag with different modifier contents, designated as C1-slag and C2-slag. These synthetic slags were blended with ordinary Portland cement at various weight ratios ranging from 10% to 40%. The synthetic slags presented sufficient hydraulic activity, and the heavy metal leaching concentrations all met the EPA's regulatory thresholds. The pore size distribution was determined by mercury intrusion porosimetry, and the results correlated with the compressive strength. The results also indicate that the incorporation of the 10% C1-slag tended to enhance the hydration degree of slag blended cement pastes during the early ages (3-28 days). However, at later ages, no significant difference in hydration degree was observed between ordinary Portland cement pastes and 10% C1-slag blended cement pastes. In the 10% C2-slag case, the trend was similar, but with a more limited enhancement during the early ages (3-28 days). Thus vitrified waste incinerator fly ash is a technically useful additive to cement, reducing the disposal needs for the toxic fly ash.

Carbon↗

An alternative method for the treatment of waste produced at a dye and a metal-plating industry using natural and/or waste materials.

The aim of this study was to develop cost-effective, appropriate solidification technologies for treating hazardous industrial wastes that are currently disposed of in ways that may threaten the quality of local groundwater. One major objective was to use materials other than cement, and preferably materials that are themselves wastes, as the solidification additives, namely using wastes to treat wastes or locally available natural material. This research examines the cement-based and lime-based stabilization/solidification (S/S) techniques applied for waste generated at a metal-plating industry and a dye industry. For the lime-based S/S process the following binder mixtures were used: cement kiln dust/ lime, bentonite/lime and gypsum/lime. For the cement-based S/S process three binder mixtures were used: cement kiln dust/cement, bentonite/cement and gypsum/cement. The leachability of the wastes was evaluated using the toxicity characteristic leaching procedure. The applicability and optimum weight ratio of the binder mixtures were estimated using the unconfined compressive strength test. The optimum ratio mixtures were mixed with waste samples in different ratios and cured for 28 days in order to find the S/S products with the highest strength and lowest leachability at the same time. The results of this work showed that the cement-and lime-based S/S process, using cement kiln dust and bentonite as additives can be effectively used in order to treat industrial waste.

Coloring Agents↗

Utilization of bottom ash from the incineration of separated wastes as a cement substitute.

Waste incineration is still an essential technology in the concept of integrated waste management. Most of the combustion residues are incinerator bottom ash. It has been discovered that incinerator bottom ash from the incineration of separated waste in the primary chamber of the modular two-stage incinerator mainly consists of metal oxides, especially SiO2 and CaO, in proportions that are quite similar to those in cement and so the feasibility of its application as a substitute for cement in concrete was investigated. It was found that after 28 days, the flexural and compressive strengths of the binder using bottom ash were practically comparable with those of a pure cement mixture. The results show that it is reasonable to use a binder containing incinerator bottom ash for applications in which an early-stage lower strength of concrete element is acceptable.

Calcium Compounds↗

Studies on recycled aggregates-based concrete.

Reduced extraction of raw materials, reduced transportation cost, improved profits, reduced environmental impact and fast-depleting reserves of conventional natural aggregates has necessitated the use of recycling, in order to be able to conserve conventional natural aggregate. In this study various physical and mechanical properties of recycled concrete aggregates were examined. Recycled concrete aggregates are different from natural aggregates and concrete made from them has specific properties. The percentages of recycled concrete aggregates were varied and it was observed that properties such as compressive strength showed a decrease of up to 10% as the percentage of recycled concrete aggregates increased. Water absorption of recycled aggregates was found to be greater than natural aggregates, and this needs to be compensated during mix design.

Conservation of Natural Resources↗

Effect of resin matrix ratio, storage medium, and time upon the physical properties of a radiopaque dental composite.

Three light curing composite pastes with varying resin matrix ratios [bisphenol A-glycidyl methacrylate (BIS-GMA)/urethane tetramethacrylate (UTMA) 25:75, BIS-GMA/UTMA 50:50, and BIS-GMA/UTMA 75:25 w/w%] were prepared in combination with a radiopaque glass powder and camphorquinone photoinitiator. Cured samples were aged at 37 degrees C in three food simulating media such as citrate buffer (pH 4.0), PBS buffer (pH 7.4), and 75% ethyl alcohol. Samples were withdrawn at specific intervals of 1, 15, 30, 45, and 60 days and tested for changes in mechanical properties, sorption, and solubility characteristics. Statistical calculations revealed significant changes in compressive strength (CS) for composites depending on the resin matrix ratio and type of medium used for aging. While diametral tensile strength (DTS) was affected adversely in citrate medium for composites with higher urethane content, samples stored in alcohol medium showed deterioration of transverse strength (TS) and microhardness (VMH) for all composites studied. Increase in BIS-GMA content in the resin matrix and storage in alcohol medium resulted in higher sorption and solubility values and lower microhardness.

Bisphenol A-Glycidyl Methacrylate↗

Novel porous hydroxyapatite prepared by combining H2O2 foaming with PU sponge and modified with PLGA and bioactive glass.

Porous hydroxyapatite (HA) scaffolds have been intensively studied and developed for bone tissue engineering, but their mechanical properties remain to be improved. The aim of this study is to prepare HA-based composite scaffolds that have a unique macroporous structure and special struts of a polymer/ceramic interpenetrating composite and a bioactive coating. A novel combination of a polyurethane (PU) foam method and a hydrogen peroxide (H(2)O( 2)) foaming method is used to fabricate the macroporous HA scaffolds. Micropores are present in the resulting porous HA ceramics after the unusual sintering of a common calcium phosphate cement and are infiltrated with the poly(D,L-lactic-co-glycolic acid) (PLGA) polymer. The internal surfaces of the macropores are further coated with a PLGA-bioactive glass composite coating. The porous composite scaffolds are characterized in terms of microstructure, mechanical properties, and bioactivity. It is found that the HA scaffolds fabricated by the combined method show high porosities of 61-65% and proper macropore sizes of 200-600 microm. The PLGA infiltration improved the compressive strengths of the scaffolds from 1.5-1.8 to 4.0-5.8 MPa. Furthermore, the bioactive glass-PLGA coating rendered a good bioactivity to the composites, evidenced by the formation of an apatite layer on the sample surfaces immersed in the simulated body fluid (SBF) for 5 days. The porous HA-based composites obtained from this study have suitable porous structures, proper mechanical properties, and a high bioactivity, and thus finds potential application as scaffolds for bone tissue engineering.

Bone Substitutes↗

Effect of amine activators on the properties of chemical cured dental composites.

The purpose of this study was to evaluate the reactivity and the effect of concentration of three tertiary amines upon the mechanical properties of a chemical curing dental composite. Chemical cured composite pastes were prepared by keeping peroxide concentration constant at 1 wt% (by weight of resin mixture) and by varying the amine/peroxide molar ratio from 0.25 to 1.5. Composite samples were prepared for all three amine pastes aged for 1, 15, 30, 45, and 60 d stored at 8, 22, and 37 degrees C. The loss in activity of the tertiary amine with time was measured. Changes in compressive strength, diametral tensile strength, and microhardness were also measured. A sharp decrease in working and setting times corresponding to increased activity was noticed with an increased amine content. The activity was found to vary in the order N,N-dimethyl p-toluidine (DMPT) > 2-(4-dimethylaminophenyl)ethanol (DMAPEA) > N,Ndiethanol p-toluidine (DEPT). DMPT is found to be more temperature sensitive than DMAPEA and DEPT. However, DEPT is found to provide better storage stability out of all three amines tested. Each amine was found to possess optimum concentrations at which the mechanical properties showed maximum values. DEPT is preferred for long-term storage stability in chemical-cured dental composites where aging tends to reduce the activity of the amine.

Amines↗

Association of collagen type 1 alpha1 gene polymorphism with bone density in early childhood.

Osteoporosis is a disease characterized by the development of nontraumatic fractures, most commonly in the vertebrae of elderly women. Approximately 500,000 elderly women in the United States are newly diagnosed with vertebral fractures every year, as the compressive strength of the vertebra, mainly determined by the density of cancellous bone and its cross-sectional area, declines with age. A recent study in women suggested that a polymorphism in the Sp1 binding site of the collagen type I gene (COLIA1) was related to decreased vertebral bone mass and vertebral fractures. Determining the phenotypic trait(s) responsible for this relationship and whether this association is manifested in childhood would further define the structural basis for decreased bone mass and help identify children "at risk" for fractures later in life. We therefore studied the COLIA1 gene polymorphism and measurements of the size and the density of vertebral bone in 109 healthy, prepubertal girls. On average, 22 girls with the Ss genotype and one girl with the ss genotype had 6.7% and 49.4% lower cancellous bone density in the vertebrae than girls with the SS genotype. In contrast, there was no association between the size of the vertebrae and the COLIA1 genotypes.

Aging↗

Advanced textile composite ring for Ilizarov external fixator system.

The use of a radiolucent composite material permits easier and more accurate radiographic evaluation of the bone healing process, and results in a much lighter system. The finite element method (FEM) is employed to determine the worst possible in-service loading condition and the ring dimensions are modified accordingly. Half-ring prototypes are produced using two types of composite materials: knitted aramid fibre fabric reinforced epoxy and random short carbon (RSC) fibre reinforced epoxy. The in-plane compressive strength and axial stiffness of the complete frame are tested according to ASTM specifications. The performance is evaluated, and compared with an existing system in simulated in-service conditions.

Biomechanical Phenomena↗

Osteotransductive bone cements.

Calcium phosphate bone cements (CPBCs) are osteotransductive, i.e. after implantation in bone they are transformed into new bone tissue. Furthermore, due to the fact that they are mouldable, their osteointegration is immediate. Their chemistry has been established previously. Some CPBCs contain amorphous calcium phosphate (ACP) and set by a sol-gel transition. The others are crystalline and can give as the reaction product dicalcium phosphate dihydrate (DCPD), calcium-deficient hydroxyapatite (CDHA), carbonated apatite (CA) or hydroxyapatite (HA). Mixed-type gypsum-DCPD cements are also described. In vivo rates of osteotransduction vary as follows: gypsum-DCPD > DCPD > CDHA approximately CA > HA. The osteotransduction of CDHA-type cements may be increased by adding dicalcium phosphate anhydrous (DCP) and/or CaCO3 to the cement powder. CPBCs can be used for healing of bone defects, bone augmentation and bone reconstruction. Incorporation of drugs like antibiotics and bone morphogenetic protein is envisaged. Load-bearing applications are allowed for CHDA-type, CA-type and HA-type CPBCs as they have a higher compressive strength than human trabecular bone (10 MPa).

Biomechanical Phenomena↗

The clinical repair of teeth using direct filling materials: engineering considerations.

This paper reviews the way in which teeth damaged by caries may be repaired clinically. The mechanical effects of caries are described, as are the materials available to repair the damage caused by this disease. Studies are reported which have shown that caries reduces the compressive strength of the tooth to less than 50 per cent of its original value and that, by use of appropriate materials and placement techniques, this can be restored to some 80 per cent of this value. However, very few studies have been carried out which view tooth repair from an engineering perspective. Instead, emphasis is placed on determining clinical durability of repairs. This is related to repair strength but brings in other factors, such as the oral hygiene of the patient. Despite this complication, durability studies show that modern restorative materials perform well under clinical conditions, from which it may be concluded that the repair process allows a structure to be fabricated that is essentially sound from an engineering viewpoint, even if inferior to the original tooth structure provided by nature.

Biomedical Engineering↗

Accurate selection of compression and antiembolic hosiery.

The use of compression and antiembolic hosiery is widespread in hospital and community settings, but there is wide variation in almost every aspect of selection and prescribing practice. In some localities pharmacists or appliance officers are responsible for selecting a suitable stocking for patients, whereas in others it may be left to medical staff. Anecdotally, there is a lack of knowledge about when and what is safe to prescribe relative to the underlying disorder. This is compounded by discrepancy between the level of compression provided by stockings made according to the European method, and that prescribable under the UK Drug Tariff in primary care. This can result in clinically serious variation in what the patient is given and what his/her condition needs. A particular problem arises when the patient's care is continued following discharge from hospital. In this case not only may an inferior quality product be supplied (meeting the Drug Tariff specifications), but also the compression 'strength' can be unintentionally lower than expected or prescribed. A simple method of prescribing according to condition and pressure has been developed and is outlined here.

Bandages↗

The effect of posture on the lumbar spine.

A series of experiments showing how posture affects the lumbar spine is reviewed. Postures which flatten (that is, flex) the lumbar spine are compared with those that preserve the lumbar lordosis. Our review shows that flexed postures have several advantages: flexion improves the transport of metabolites in the intervertebral discs, reduces the stresses on the apophyseal joints and on the posterior half of the annulus fibrosus, and gives the spine a high compressive strength. Flexion also has disadvantages: it increases the stress on the anterior annulus and increases the hydrostatic pressure in the nucleus pulposus at low load levels. The disadvantages are not of much significance and we conclude that it is mechanically and nutritionally advantageous to flatten the lumbar spine when sitting and when lifting heavy weights.

Humans↗

Treatment of skeletally mature ovariectomized rhesus monkeys with PTH(1-84) for 16 months increases bone formation and density and improves trabecular architecture and biomechanical properties at the lumbar spine.

UNLABELLED: Histomorphometric studies of treatments for osteoporosis in humans are restricted to iliac crest biopsies. We studied the effects of PTH(1-84) treatment at the lumbar spine of skeletally mature ovariectomized rhesus monkeys. PTH increased bone turnover, rapidly normalized BMD, and increased vertebral compressive strength. PTH increased trabecular bone volume primarily by increasing trabecular number by markedly increasing intratrabecular tunneling. INTRODUCTION: Histomorphometric studies of the anabolic properties of PTH(1-84) (PTH) and related peptides in human bone are restricted to iliac crest biopsies. The ovariectomized (OVX) monkey is an accepted model of human postmenopausal bone loss and was used to study the effects of PTH treatment at clinically relevant skeletal sites. MATERIALS AND METHODS: Skeletally mature rhesus monkeys were OVX or sham-operated and, after a bone depletion period of 9 months, treated daily for 16 months with PTH (5, 10, or 25 microg/kg). Markers of bone formation (serum osteocalcin) and resorption (urine N-telopeptide [NTX]) and lumbar spine BMD were measured throughout the study. Trabecular architecture and vertebral biomechanical properties were quantified at 16 months. RESULTS: PTH treatment induced dose-dependent increases in bone turnover but did not increase serum calcium. Osteocalcin was significantly increased above OVX controls by 1 month. NTX was significantly elevated at 1 month with the highest dose, but not until 12 months with the 5 and 10 microg/kg doses. Lumbar spine BMD was 5% lower in OVX than in sham animals when treatment was started. All PTH doses increased BMD rapidly, with sham levels restored by 3-7 months with 10 and 25 microg/kg and by 16 months with 5 microg/kg. PTH treatment increased trabecular bone volume (BV/TV), primarily by increasing trabecular number, and dose-dependently increased bone formation rate (BFR) solely by increasing mineralizing surface. The largest effects on BV/TV and yield load occurred with the 10 microg/kg dose. The highest dose reduced trabecular thickness by markedly increasing intratrabecular tunneling. CONCLUSIONS: PTH treatment of OVX rhesus monkeys increased bone turnover and increased BV/TV, BMD, and strength at the lumbar spine. All PTH doses were safe, but the 10 microg/kg dose was generally optimal, possibly because the highest dose resulted in too marked a stimulation of bone remodeling.

Animals↗

Long-term changes in bone mineral and biomechanical properties of vertebrae and femur in aging, dietary calcium restricted, and/or estrogen-deprived/-replaced rats.

To study the long-term effect of aging, low calcium diet (LCD) and/or ovariectomy (OVX), and estrogen replacement therapy (+E) on rat bone quality of both trabecular and cortical bone, 150 female Wistar rats of 4.5 months were divided into baseline, sham-operation (sham), sham + LCD, OVX, OVX + E, OVX + LCD, OVX + LCD + E, and were observed for 3, 6, and 9 months postsurgery. The bone mineral density (BMD) of the lumbar spine L1-L4, the femoral neck, the midshaft, and the distal metaphysis were determined using dual-energy X-ray absorptiometry (DXA) in vitro. Biomechanical tests of the L1 vertebral body and the left femur were performed. The right femoral midshaft and neck were processed undecalcified for determining cross-sectional moments of inertia (CSMIs). BMD in all groups increased rapidly with aging in the femoral midshaft composed only of cortical bone at 3 months post-OVX and stabilized or decreased thereafter, but decreased at all observation periods in the distal femoral metaphysis, consisting mostly of trabecular bone. L1 maximum compressive strength and stiffness increased as a function of aging in sham and sham + LCD but not in OVX and OVX + LCD. The order of loss in BMD at all sites and in L1 strength and stiffness was: OVX + LCD > OVX > LCD. LCD reduced while OVX improved the total femoral area, CSMIs in the femoral midshaft, and the torsional strength. Estrogen treatment preserved BMD and prevented OVX-induced loss in L1 strength. The BMD and biomechanical properties were greater in OVX + E than in OVX + LCD + E. Loss in BMD and CSMIs was greater in the femoral neck than in the midshaft. The data suggest that rat cortical bone might not be matured until 7.5 months of age. It would be more appropriate to consider rats at peak bone mass as a model of mature rat and to perform OVX at that time. LCD and OVX have a great potential for weakening the bone quality of cortical bone and trabecular bone, respectively, and have an additive effect when combined. Estrogen prevents only OVX-induced bone loss.

Absorptiometry, Photon↗

Physical properties of dental silver-tin amalgams with high and low copper contents.

Newly developed amalgams such as Tytin, Sybraloy, and Dispersalloy had low static creep, high compressive strength, and similar values for both diametral tensile strength and dimensional change in comparison with conventional amalgams such as Kerr Spheraloy, Caulk Spherical, Shofu Spherical, and Caulk 20th Century Micro Cut. The data for physical properties were evaluated statistically, and the amalgams were ranked according to the numerical position assigned to each property.

American Dental Association↗

[The further development of a human, alloplastic tracheal prosthesis].

The present paper discusses the design, construction and characterization of human alloplastic tracheal prostheses. Two different types of construction, the spiral and the clasp prosthesis, have been developed. The prostheses are composite constructions comprising a silicone tube and a polyethylene reinforcement connected together by means of a biocompatible adhesive. The results of various mechanical examinations (stress-strain behavior, torsional strength, compressibility, bending stiffness, fatigue testing) show that some of the 14 prostheses investigated approach the human trachea in terms of mechanical properties, and may be considered suitable. Suggestions for further improvements are made.

Biomechanical Phenomena↗

Noninvasive assessment of stiffness and failure load of human vertebrae from CT-data.

A calculational method based on noninvasively derived data for the assessment of the mechanical quality of individual vertebrae is presented. Dimensional data obtained from serial, segmented CT scans were used as the geometric input for a newly developed finite element model designed to calculate stiffness and failure load of these complex bone structures. Mechanical, structural data for cancellous bone was obtained by measurements of the compressive strength and failure load of actual vertebral specimens obtained at autopsy. The stiffness and failure load calculated by the newly developed finite element model were compared with the data obtained from mechanical measurements of vertebral specimens. A high correlation between measured and calculated failure load was found (r = 0.89, p < 0.001, n = 16). The correlation between the failure load and bone mineral density (BMD) was significant (r = 0.82, p < 0.001, n = 16). A similar correlation between calculated and measured stiffness (r = 0.81, p < 0.001, n = 15) was also found using the finite element model described herein. Thus the newly developed calculation methodology has been verified and can be used to predict the failure load and stiffness of osteoporotic vertebrae using data obtained non-invasively from CT scans.