PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Pyrolysis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66Linked to original sources

Determination of manganese in herbal medicine samples by slurry-sampling electrothermal atomic absorption spectrometry with a metal tube atomizer.

An ultrasonic slurry-sampling electrothermal atomic absorption spectrometry with a molybdenum tube atomizer has been developed for the determination of manganese in herbal medicine samples. Ten percent glycerol solution was used as the slurry medium. The optimum pyrolysis temperature was 400 degrees C. The detection limit was 69 fg (3xS/N). Matrix element interference was checked and it was found that glycerol as a chemical modifier eliminated the interference. The amounts of manganese in herbal medicines determined by the proposed method are in good accordance with those measured in dissolved acid-digested samples. The method enables rapid calibration, and simple and rapid analysis of manganese in herbal medicine samples at low cost.

Herbal Medicine↗

ETAAS determination of nickel in serum and urine.

Methods for the direct determination of Ni in human blood serum and urine by electrothermal atomic absorption spectrometry (ETAAS) are described. Hydrogen peroxide was proposed as matrix modifier, assisting thermal decomposition of proteins during the ashing step. A pyrolysis temperature of 1,200 degrees C was found to be optimal while 2,100 degrees C and 2,200 degrees C were found to be optimal atomizing temperatures for Ni in serum and urine respectively. Calibration was performed by using a calibration curve prepared with aqueous standard solutions of Ni (glycine must be used as modifier for Ni in aqueous solutions). The limits of detection, defined as the blank values plus 3 times the standard deviation of the blank values, were 0.2 microg/L for both serum and urine samples. Relative standard deviations for serum samples with concentrations of Ni in the range 0.5-2 microg/L were 10-15% and for urine samples with Ni concentrations in the range 0.5-2.5 microg/L were 8-10%.

Calibration↗

Simultaneous determination of inorganic mercury and methylmercury compounds in natural waters.

The purpose of the present work was to develop a simple, rapid, sensitive and accurate method for the simultaneous determination of inorganic mercury (Hg(2+)) and monomethylmercury compounds (MeHg) in natural water samples at the pg L(-1) level. The method is based on the simultaneous extraction of MeHg and Hg(2+)dithizonates into an organic solvent (toluene) after acidification of about 300 mL of a water sample, followed by back extraction into an aqueous solution of Na(2)S, removal of H(2)S by purging with N(2), subsequent ethylation with sodium tetraethylborate, room temperature precollection on Tenax, isothermal gas chromatographic separation (GC), pyrolysis and cold vapour atomic fluorescence spectrometric detection (CV AFS) of mercury. The limit of detection calculated on the basis of three times the standard deviation of the blank was about 0.006 ng L(-1) for MeHg and 0.06 ng L(-1) for Hg(2+)when 300 mL of water was analysed. The repeatability of the results was about 5% for MeHg and 10% for Hg(2+). Recoveries were 90-110% for both species.

Chromatography, Gas↗

Direct determination of Cr and Cu in urine samples by electrothermal atomic absorption spectrometry using ruthenium as permanent modifier (R1).

In this study Ru, deposited thermally on an integrated platform pyrolytic graphite tube, is proposed as a permanent modifier for the determination of Cu and Cr in urine samples by electrothermal atomic absorption spectrometry. The samples were diluted 1:1 with nitric acid (1% v/v). Pyrolysis and atomization temperatures for spiked urine samples were 1,100 degrees C and 1,900 degrees C respectively for Cu, and 1,400 degrees C and 2,500 degrees C respectively for Cr. For comparison purposes, the conventional modification with Pd+Mg was also studied. The sensitivity for Ru as permanent modifier was higher for the two analytes. The characteristic masses were 7.3 and 17.7 for Cr and Cu. The detection limits (3sigma) were 0.22 and 0.32 microg/L, for Cr and Cu, respectively. Good agreement was obtained with certified urine samples for the two elements.

Chromium↗

Origin assessment of green coffee (Coffea arabica) by multi-element stable isotope analysis of caffeine.

The delta(13)C(VPDB), delta(2)H(VSMOW) and delta(18)O(VSMOW) values of caffeine isolated from Arabica green coffee beans of different geographical origin have been determined by isotope ratio mass spectrometry (IRMS) using elemental analysis (EA) in the "combustion" (C) and "pyrolysis" (P) modes (EA-C/P-IRMS). In total, 45 coffee samples (20 from Central and South America, 16 from Africa, six from Indonesia, and three from Jamaica and Hawaii) were analysed, as well as three reference samples of synthetic caffeine. Validation was performed by excluding isotope discrimination in the course of sample preparation and determining linear dynamic ranges for EA-P-IRMS measurements. The values for caffeine from green coffee ranged from -25.1 to - 29.9 per thousand, -109 to -198 per thousand, and +2.0 to -12.0 per thousand for delta(13)C(VPDB), delta(2)H(VSMOW), and delta(18)O(VSMOW), respectively. Data evaluation by linear discrimination analysis (LDA) and by classification and regression tree (CART) analysis revealed the delta(18)O(VSMOW) values to be highly significant. Use of LDA on the delta(2)H(VSMOW) and delta(18)O(VSMOW) data from coffee of African and Central/South American provenance led to error rates of 5.7% and 7.7% for adaption and cross validation, respectively.

Journal Article↗

Slurry sampling for the determination of thallium in soils and sediments by graphite furnace atomic absorption spectrometry.

The analytical conditions for thallium determination in soils and sediments by slurry sampling graphite furnace atomic absorption spectrometry were studied and optimized. Elimination of a strong background for soils rich in organic materials by application of tungsten carbides coated graphite tubes/platforms was studied in detail. Tungsten carbides increased the maximum permissible pyrolysis temperature from 300 to 900 degrees C. The mechanism of tungsten carbide formation on different graphite surfaces was proposed. Application of a strong basic anion-exchange resin for interference elimination in thallium determination in marine sediments was described. Calibration was performed directly using aqueous standards both for soil and sediment analysis. Analysis of CRM confirmed the reliability of the approach. The precision and accuracy of thallium determination by the described method for soils and sediments was acceptable. A characteristic mass of 13.8 pg was obtained and the limit of detection for the proposed method was around 0.06 microg g(-1) Tl.

Journal Article↗

Analysis of functional groups on the surface of plasma-treated carbon nanofibers.

Plasma chemically modified carbon nanofibers were characterized by X-ray photoelectron spectroscopy with regard to the content of carbon, oxygen, and nitrogen and the contribution of carboxylic groups or ester, carbonyl and hydroxylic groups or ether on the surface. Unfortunately, X-ray photoelectron spectroscopy only provides an average value of the first 10 to 15 molecular layers. For comparison, depth profiles were measured and wet chemical methods were applied to estimate the thickness of the functionalized layer and the distribution of oxygen-containing functional groups within the near-surface layers. The results indicate that the fiber surface is covered by a monomolecular oxygen-containing layer and that plasma treatment allows a complete oxygen functionalization of the uppermost surface layer. The best conditions for plasma treatment found within the set of parameters applied to generate complete functionalization are: plasma gas O(2)/Ar ratio 1:1, gas pressure 1-1.5 hPa, plasma power 80 W, treatment time >or= 5 min. Additionally, three quick and easy methods are presented to estimate the efficiency of plasma treatment with regard to surface functionalization: pyrolysis, contact angle measurements, and light permeability measurements of aqueous carbon nanofiber suspensions.

Journal Article↗

Synchronous fluorescence for simultaneous determination of hydroquinone and resorcinol in air samples.

Several phenolic compounds are present in tobacco smoke. They are formed from the pyrolysis of tobacco during the smoking process and all of them are toxic. Therefore, the determination of these compounds in air samples is important. A rapid, simple, and sensitive method using a synchronous spectrofluorimetry technique was developed to quantify hydroquinone and resorcinol simultaneously. One of the advantages of this method is the simple and rapid sampling technique, which uses water as the absorption solution of the analytes in the air sample. The precision of the method (%RSD) was 1.8% and the detection limits were 0.125 mg m(-3) and 0.292 mg m(-3) for hydroquinone and resorcinol, respectively.

Air Pollutants↗

Structural and optical characterization of pyrolytic carbon derived from novolac resin.

The structural and optical properties of technologically interesting pyrolytic carbons formed from cured novolac resin and cured novolac/biomass composites were studied by X-Ray Diffraction Analysis (XRD), and Fourier Transform Infrared (FTIR), Raman and Photoluminescence (PL) spectroscopy. Pyrolysis of the cured materials took place at temperatures in the range 400-1000 degrees C. The most important weight loss, shrinkage and structural changes of pyrolyzed composites are observed at temperatures up to 600 degrees C due to the olive stone component. In the same temperature range, the changes in pyrolyzed novolac are smaller. The spectroscopic analysis shows that novolac pyrolyzed up to 900 ( degrees )C has less defects and disorder than the composites. However, above 900 ( degrees )C, pyrolyzed novolac becomes more disordered compared to the pyrolyzed composites. It is concluded that partial replacement of novolac by olive stone in the composite materials leads to the formation of a low cost, good quality product.

Biomass↗

Direct determination of arsenic and antimony in naphtha by electrothermal atomic absorption spectrometry with microemulsion sample introduction and iridium permanent modifier.

This paper reports the determination of arsenic and antimony in naphtha by employing electrothermal atomic absorption spectrometry (ETAAS) as the analytical technique. In order to promote the direct determination of the analytes in the very volatile naphtha, the formation of a microemulsion with different surfactants (Triton X-100 and Brij-35) and different chemical modification strategies were tested. The results indicated that Triton X-100 is the best emulsification agent for naphtha in both As and Sb determination when it is employed at a concentration of 1% w/v in the microemulsion. Under these conditions, the microemulsion was stabile for at least 2 h. By using Brij-35 it was possible to achieve good stability only in the first 15 min. Among all chemical modification approaches investigated (Ir permanent modifier, W-Ir permanent modifier, and Pd modifier), the Ir permanent modifier provided better sensitivity for both analytes and allowed a higher pyrolysis temperature, which decreased the background signals at lower levels. Under the best conditions established in this work, an RSD of 4.6% (20 microg L(-1)) and a detection limit of 2.7 microg L(-1) were observed for arsenic. For antimony, an RSD of 4.0% (20 microg L(-1)) and a detection limit of 2.5 microg L(-1) were obtained. The accuracy of the procedure was assessed by analyzing spiked samples of naphtha from different origins.

Journal Article↗

The determination of total Se in urine and serum by graphite furnace atomic absorption spectrometry using Ir as permanent modifier and in situ oxidation for complete trimethylselenonium recovery.

The present work evaluated the use of iridium (Ir) as permanent modifier for the determination of total selenium in urine and serum by graphite furnace atomic absorption spectrometry. Concerning urine, the presence of trimethylselenonium (TMSe(+)) was especially considered. Pyrolysis and atomization temperatures of 1,000 and 2,100 degrees C, respectively, were used. For nondigested urine and serum samples, 0.2% v/v HNO(3) and Triton X-100 were used as diluents, respectively, and the same initial platform Ir treatment was effective for up to 1,100 atomization cycles. Good precision [less than 5% relative standard deviation (RSD)] can be achieved with the proposed method. Low TMSe(+) recovery was observed for nondigested urine samples. Thus, if this species is to be considered in urine analysis, a previous external mineralization step was found to be necessary. Alternatively, an in situ oxidation treatment was developed. Detection limits of 8, 10, and 7 mug l(-1) were obtained after dilution, microwave-assisted digestion, and in situ oxidation procedures, respectively. The accuracy of the method was validated by the analysis of certified reference or commercial quality control materials and spiked samples.

Graphite↗

Establishing a chromium-reactor design for measuring delta2H values of solid polyhalogenated compounds using direct elemental analysis and stable isotope ratio mass spectrometry.

2H/1H isotope ratios of polyhalogenated compounds were determined by elemental analysis and isotope ratio mass spectrometry (EA-IRMS). Initial measurements with standard EA-IRMS equipment, which used high-temperature pyrolysis to convert the organic compounds into hydrogen, did not achieve significant signals for polychlorinated pesticides and related compounds, presumably due to the formation of HCl instead of hydrogen. To reverse this problematic reaction, a chromium reactor was incorporated into the element analyzer system, which scavenged Cl, forming chromium chloride and releasing hydrogen again in the form of H2. The optimized system therefore allowed the delta2H values of polyhalogenated compounds to be determined. A quality assurance program was developed based on several parameters. (i) Each compound was analyzed using a sequence of five injections, where the first measurement was discarded. (ii) Recovery of H (when calculated relative to acetanilide) had to be >90% for all replicates in a sequence. (iii) All delta-values within a sequence had to vary by less than 10/1000. (iv) Results had to be reproducible on another day with a different sample scheme. Once this reproducibility had been established, variabilities in the delta2H values of organohalogen standards were investigated using the technique. The highest delta2H value of +75/1000 was found for o,p'-DDD, whereas the strongest depletion in deuterium was found for Melipax (-181/1000). The most important results for comparable compounds were as follows. DDT-related compounds gave delta2H values of between +59 and +75/1000 (technical DDT, o,p'- and p,p'-DDD) or in the range of approximately -1/1000, indicative of the different sources/methods of producing this compound. Four HCH isomers from the same supplier showed relatively similar hydrogen isotope distributions, whereas two lindane (gamma-HCH) standards from other sources had 39/1000 less deuterium. This difference is likely due to different purification steps during the isolation of pure lindane from the technical HCH mixture. An even greater difference was observed between the delta2H values of Toxaphene (US product dating from 1978) and Melipax (product from the former East Germany, dating from 1979), which gave delta2H values of -101/1000 and -181/1000, respectively, meaning that both products were easily distinguished via delta2H-IRMS. Fractioning of hydrogen isotopes in the atmospheric water cycle was suggested as one reason for the different values. In this theory, the water (which had different delta2H values depending on where it was taken from) was incorporated during the biosynthesis of camphene, which is the natural product used to produce both products. These results indicate that hydrogen isotope-specific analysis can be a valuable tool for tracing the origins of a compound in certain cases.

Aldrin↗

Eu3+-doped Gd2O3 nanoparticles as reporters for optical detection and visualization of antibodies patterned by microcontact printing.

Lanthanide oxide nanoparticles are promising luminescent probes in bioanalysis, because of their unique spectral properties, photostability, and low-cost synthesis. We report for the first time the application of europium-doped gadolinium oxide (Eu:Gd2O3) nanoparticles to the optical imaging of antibody micropatterns. The nanoparticles were synthesized by spray pyrolysis and coated with antibody (IgG) molecules by physical adsorption. Our experiments showed that the Eu:Gd2O3 is a good biocompatible solid support for antibody immobilization. The antibodies (anti-rabbit IgG) immobilized on the nanoparticles had excellent biological activity in the specific recognition reaction with rabbit IgG patterned in line strips (10 micromx10 microm) on a glass substrate by use of a micro-contact printing technique. The specific immunoreaction was confirmed by two independent microscopic techniques-fluorescence and scanning electron microscopy (SEM). Both microscopic images revealed that the nanoparticles were organized into designated structures as defined by the microcontact printing process with negligible non-specific binding. The nanoparticles can be used as fluorescent markers in a variety of immunosensing applications in a microscale format.

Adsorption↗

Investigation of the species-specific degradation behaviour of methylmercury and ethylmercury under microwave irradiation.

The degradation behaviour of methylmercury (MeHg) under microwave irradiation is investigated, as is the (different) degradation behaviour of ethylmercury (EtHg) under similar irradiation. A simple and highly sensitive SPME-GC-pyrolysis-AFS system was used to analyse the aqueous MeHg and EtHg standard solutions after derivatization with sodium tetraphenylborate (NaBPh(4)). Samples were irradiated in a microwave digester at microwave powers ranging from 20 to 160 W for durations of 2 to 10 min. The different tolerances towards microwave treatment of the two organomercury species were evident. Practically no degradation was experienced for MeHg for up to 8 minutes of irradiation at 120 W or for up to 4 minutes at 160 W. Significant analyte loss was observed for EtHg after 2 minutes at 40 W of microwave power.

Journal Article↗

Direct solid sampling electrothermal atomic absorption spectrometry for the analysis of high-purity niobium pentaoxide.

A direct solid sampling electrothermal atomic absorption spectrometry (SoS-ETAAS) method for ultratrace analysis of powdered niobium pentaoxide for Al, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni and Zn has been developed. The elements K, Mg, Na and Zn could be determined without any chemical modification. However, in the determination of the elements Al, Co, Cr, Cu, Fe, Mn and Ni, serious matrix-caused non-spectral interferences and background occurred which made their determination impossible. This problem was remedied by conversion of the niobium pentaoxide matrix into the thermally stable niobium carbide by using methane atmosphere during the pyrolysis stage. The development resulted in establishing an extraordinary powerful method for the analysis of niobium pentaoxide in term of limits of detection, accuracy, simplicity and analysis time. Quantification was performed using calibration curves measured with aqueous standard solutions. The accuracy was checked by comparing the results with those obtained by ETAAS in analysis of slurries and digests of the sample. Due to almost complete freedom of blank and high applicable sample amounts (up to 15 mg), extremely low limits of detection (0.5-2 ng/g) were achieved.

Journal Article↗

Effects of various salts on the determination of arsenic by graphite furnace atomic absorption spectrometry. Direct determination in seawater.

The effect of Na, Mg, Ca and Sr as their nitrate, chloride and sulfate salts and seasalt, with and without the use of palladium, on the determination of arsenic by electrothermal atomic absorption spectrometry was investigated. In the absence of any stabilizing agent, arsenic was partially lost as molecular species at low temperatures. The effect of salts on the shape of the atomization signal, the integrated absorbance and the stabilizing effect were highly dependent both on their nature and mass. By trapping arsenic, oxide species resulting from the decomposition of nitrate salts induced a high stabilization effect depending on their vaporization temperatures: MgO approximately CaO>SrO>Na2O. The stabilization effect of chlorides occurred about 200 degrees C lower and depended on mass, volatility and hydrolytic properties: SrCl2>CaCl2>MgCl2 approximately NaCl. The effect of sulfates was mainly dependent on their decomposition/vaporization mechanisms, and in the presence of Na2SO4 or CaSO4 a strong chemical interference effect was observed. Palladium stabilized arsenic in the presence of nitrates, chlorides or even sulfates, leading to a similar delaying effect, signal shape and integrated absorbance. Seasalt induced also important modifications to the atomization signal of As. Moreover, an interference effect was observed, which could probably be attributed to the simultaneous vaporization of sulfate in seasalt. In seawater, Pd suppressed this interference effect and permitted to use a high pyrolysis temperature up to 1400 C to remove the major part of the seawater matrix before atomization. Under optimized conditions, the detection limit for As obtained in unmodified seawater in the presence of Pd was 0.34 microg L(-1) for a 10 microl sample.

Journal Article↗

Tungsten atomizer--theory of atomization mechanism of some volatile analytes.

Several types of chemical reactions may participate in the evolution of free atoms in a tungsten furnace. Reactions may take place either in the homogeneous or heterogeneous phase. The assumed reactions may be classified into four types according to the phases in which they take place. Reactions occurring in the gaseous phase, i.e. in the inner volume of the furnace, are kinetically more significant. However, for atomization of easily volatile analytes heterogeneous reaction between gaseous compounds and between condensed salts of analytes and the solid surface of the furnace become significant. With regards to the reaction mechanisms during drying, pyrolysis and atomization of nitrates of volatile analytes, three basic types of chemical reactions may be assumed. Free atoms of analytes arise by evaporation of the elementary form of analytes at atomization temperature, where the particular analyte in its elementary form is produced by direct reduction of analyte nitrate by tungsten or by hydrogen at higher temperatures. Precursory reactions of atom formation are reduction reactions which occur between analyte nitrates and tungsten, between analyte nitrates and hydrogen, as well as reactions of thermal dissociation of relevant nitrates. The importance of particular types of precursory reactions for formation of metallic analytes or their oxides is documented by dependence of Gibbs energy values of particular reactions on the temperature.

Journal Article↗

Direct observation of the formation of aromatic pollutants in waste incineration flue gases by on-line REMPI-TOFMS laser mass spectrometry.

On-line REMPI-TOFMS laser mass spectrometry (Resonance Enhanced Multi-Photon Ionization-Time-Of-Flight Mass Spectrometry) was used to monitor combustion and pyrolysis byproducts from industrial combustion processes, including polycyclic aromatic hydrocarbons (PAH) and monochlorobenzene in the flue gas of an industrial 22 MW hazardous waste incineration plant. Sampling at different places in the flue gas stream revealed the complexity of the processes responsible for the formation of the different chemical species, while time resolved measurements depicted the emission dynamics.

Air Pollutants↗