PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “RIGIDITY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66Linked to original sources

Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site.

A two-stage endosseous implant, placed in the retromolar area of the mandible was utilized as rigid anchorage to translate two molars 10-12 millimeters mesially into an atrophic endentulous ridge. Despite substantial anchorage demand over a three year period, the endosseous implant remained rigid ("osseointegrated"). At the end of treatment the implant and adjacent, intravitally labeled bone were recovered. Microradiographic and polarized light analyses revealed that about 80 percent of the endosseous portion of the implant was in direct contact with mature lamellar bone. Bone labels demonstrated a remarkably high remodeling rate (about 30 percent/year) for cortical bone within 0.5 millimeter of the interface. Continuous remodeling may be the long-term mechanism whereby loaded implants resist bone fatigue and maintain "osseointegration." Clinical use of orthodontic implants, placed outside the dental arches, requires careful attention to soft tissue management.

Adult↗

Insertion of the Combitube airway with the cervical spine immobilised in a rigid cervical collar.

The Combitube is a twin lumen device designed to establish the airway after blind insertion. Under general anaesthesia a rigid cervical collar was used to immobilise the neck in 15 ASA 1 and 2 patients. Insertion of the Combitude airway was then attempted. In 10/15 (66%) patients, blind insertion was not possible. In 5/15 (33%) successful blind insertions the Combitube entered the oesophagus on each occasion. In 8/10 of the failures, re-insertion of the Combitude was attempted with the aid of a Macintosh laryngoscope. In 6/8 cases (75%) satisfactory placement was then possible with the Combitube again entering the oesophagus on each occasion. Ventilation was satisfactory in all patients when insertion was successful. Blood staining of the Combitube was present in 7/15 (47%) patients. The Combitude cannot be recommended for use in patients whose necks are immobilised in rigid cervical collars.

Adult↗

Radiographic stereophotogrammetric evaluation of intersegmental stability after mandibular sagittal split osteotomy and rigid fixation.

PURPOSE: The purpose of this study was to determine if rigid fixation with bicortical screws and/or miniplates with monocortical screws prevent mobility at the osteotomy site after bilateral mandibular sagittal split osteotomy. PATIENTS AND METHODS: Three metal bone markers were inserted in the proximal and the distal segments of the mandible during the sagittal split operation in 10 patients. These served as measurement points in postoperative follow-up by radiographic stereophotogrammetry. The patients were examined at intervals during the first postoperative year. At each examination, 2 sets of radiographic stereograms were obtained: 1 in rest position and 1 with stress applied to the osteotomy sites. The difference in the position of the proximal segment in relation to the distal segment between the 2 sets of stereograms was recorded. Findings greater than 0.4 degrees and 0.2 mm change indicated true displacement of the bone segments. RESULTS: Immediately after surgery, mobility at of the osteotomy site(s) was found in 8 of 10 patients, and after 1 year it was still present in 4 patients. CONCLUSIONS: Fixation with bicortical screws or miniplates and monocortical screws does not prevent mobility at the osteotomy site after sagittal split osteotomies. This mobility may remain as long as 1 year after surgery. The term "rigid fixation" is thus not a proper term for this kind of fixation.

Adolescent↗

Evaluation of a nontoxic rigid polymer as connecting bar in external skeletal fixators.

OBJECTIVE: To investigate the mechanical characteristics of a nontoxic, low-cost, rigid polymer (RP) and to compare the structural and mechanical properties of a full-frame external skeletal fixator (ESF) with either RP connecting bars, polymethylmethacrylate (PMMA) connecting bars, or stainless-steel (SS) clamps and connecting bars. STUDY DESIGN: In vitro mechanical evaluation. METHODS: Mechanical properties were assessed using an in vitro bone fracture model with a bilateral uniplanar ESF (type II). Identical ESF were built with connecting bars using RP (n = 8), PMMA (n = 8), and SS connecting bars and clamps (System Meynard; n = 3). Nondestructive mechanical tests were performed in uniaxial compression (AC) and craniocaudal (CC) 4-point bending, as well as fatigue AC. Composite stiffness for each specimen and for each loading mode was calculated from 6 replicate measures using the slope of the load displacement curve at small displacements. RESULTS: RP, PMMA, and SS ESF constructs yielded mean +/- SD composite stiffness values of 227 +/- 15, 381 +/- 30, and 394 +/- 9 N/mm in AC and of 35 +/- 2, 24 +/- 2, and 15 +/- 0 N/mm in CC, respectively. CONCLUSIONS: Structural and mechanical properties of RP are satisfactorily rigid and fatigue resistant for its use as a connecting bar in ESF. CLINICAL RELEVANCE: RP connecting bars in an ESF are a reliable, versatile, nontoxic and inexpensive option for the veterinary surgeon.

Animals↗

Angled rigid neuroendoscope for continuous intraoperative visual monitoring: technical note.

We developed and tested a new, angled rigid endoscope as a tool for performing continuous visual monitoring during microsurgery. The shaft of the scope is angled 110 degrees at its midportion using a prism. We used the scope continuously in 30 cases including 15 pituitary tumours, 7 brain tumours, 7 cerebral aneurysms, and one hemifacial spasm. For pituitary tumours the tip of the scope was positioned in the sphenoid sinus or in the cavity formed by tumour removal; for cerebral aneurysms it was placed behind the parent artery or the aneurysmal neck. Image quality was acceptable for intraoperative monitoring. In no case did the neuroendoscope have a deleterious impact on th e proper function of the microscope or surgical instruments. This angled rigid scope was more effective for intraoperative monitoring than conventional straight scopes.

Endoscopes↗

[Is the rigid hypopharyngo-esophagoscopy for suspected foreign body impaction still up to date?].

BACKGROUND: The increasing use of flexible esophagoscopes leads to controversies regarding the current status of rigid hypopharyngo-esophagoscopy in case of suspected foreign body impaction. METHODS: In a retrospective investigation we analyzed 309 open tube hypopharyngo-esophagoscopies performed for suspected foreign body impaction. RESULTS: In 108 patients (35.0 %) a foreign body was detected endoscopically. 69 Patients (22.3 %) had other pathologic findings within the upper digestive tract. 72 % of the foreign bodies and 83 % of the pathologic findings were localized within the hypopharynx or the cervical esophagus. CONCLUSIONS: The superior diagnostic and therapeutic properties of the classical rigid endoscopy in this area underlines its still actual status in patients with suspected foreign body impaction.

Adolescent↗

Endoscopic mucosal resection in the esophagus with a new rigid device: an animal study.

BACKGROUND AND STUDY AIMS: : There is a growing trend toward the use of minimally invasive endoscopic methods to treat early esophageal cancers. Although there is continuing controversy regarding the management of Barrett's esophagus and the value of surveillance programs continues to be debated, the ultimate goal is to eradicate all of the foci of intestinal metaplasia and hence the risk of developing an adenocarcinoma. A number of ablative techniques have so far been applied, but none has yet been shown to be superior and entirely satisfactory. The present study evaluates the feasibility, efficacy, and safety of a promising new method of endoscopic mucosal resection (EMR) in a sheep model, based on the use of a modified rigid esophagoscope. MATERIALS AND METHODS: The resectoscope consists of a rigid esophagoscope with a distal transparent window through which the mucosa and part of the submucosa are sucked in and then resected with a wire loop. The sheep model was chosen because of its similarities to human anatomy with regard to the thickness and histological structure of the esophagus. Fifty-five separate hemicircumferential resections and 11 circumferential resections were carried out in 21 and 11 animals, respectively. Mitomycin C, an agent inhibiting fibroblast proliferation, was administered at different time intervals after eight circumferential resections to prevent the development of esophageal strictures. RESULTS: All of the specimens of hemicircumferential resections were obtained as single distinct pieces and were easily examined histologically. The surface of the specimen correlated with the size of the window and ranged from 6 to 12 cm (2). In circumferential resections, the specimens were obtained in two pieces. An accurate resection depth through the submucosa was achieved in 58 of 65 resected specimens. No complications occurred after hemicircumferential resections. Complications after circumferential resections (stenosis or perforation, or both) were minimized after appropriate timing of mitomycin C administration. CONCLUSIONS: This EMR method offers a promising approach in comparison with other options currently available. It appears to be superior in terms of the size of the resected specimen, the precision and regularity of the resection depth, and the accuracy of histological diagnosis with safety margins. Hemicircumferential EMRs have been shown to be safe in the sheep model. This new technique warrants further animal studies before being used for circumferential EMR in humans.

Animals↗

[Contouring of a rigid eyelid implant: indication for the replacement with the platinum chain].

BACKGROUND: The resultant lagophthalmos at peripheral facial palsy can lead to keratopathy of varying degrees. In surgical therapy of lagophthalmos some implants to preserve a sufficient eyelid closure have been described. Besides to the use of magnets, silicone slings or palpebral springs the importance of the gold implantation (lidloading), first described by Illig in 1958, has increased. Unfortunately all of these techniques have often shown unwanted side effects. The platinum chain is a new implant which promises, due to its flexibility, lower postoperative complications. PATIENTS: We present two case reports to show the platinum chain's advantages compared to the older implants. The two patients developed a unsightly contouring (with threatening extrusion) of the rigid gold implant after lidloading. These gold implants were therefore replaced in one step by the platinum chain. RESULTS AND CONCLUSIONS: The further process was complication-free. In our opinion, in spite of the small case number, the new developed platinum chain can lead to a reduction of postoperative complications after lidloading. In complications with the rigid gold implants, such as contouring or extrusion, these implants can mostly be replaced in one step by corresponding platinum chains.

Adult↗

[Intubation aid by a rigid endoscope].

A method has been developed making it possible to look around intubation obstacles with the aid of rigid angular-lens systems. A glottis that is not or is only partly visible in direct laryngoscopy can be visualized endoscopically. The normal intubation technique is retained. A rigid endoscope is additionally introduced into the oropharynx, the glottis located endoscopically, and the endoscope secured to the laryngoscope in the position. The free hand can then be used to advance the tube through the glottis into the trachea under endoscopic control. This endoscopic method is intended to augment the physician's instrumental repertoire.

Endoscopes↗

Rigid or flexible choledochoscopy?

This is a comparative study of two types of choledochoscopes: The Wolf rigid scope and the flexible CHF B3 Olympus scope. These were used for the exploration of 120 consecutive cases of common bile duct disease covering a 4-year period. The rigid and the flexible choledochoscopes were used in 30 and 88 cases, respectively, while in another 2 cases both scopes were used to complete the examination. We established that the Wolf scope does not provide ease of handling in inexperienced hands. Its low price and durability under rough handling should not be an excuse for recommending it for beginners. On the other hand, the Olympus scope is an expensive and delicate instrument, which is much easier to handle. Both choledochoscopes can, however, equally provide good results in experienced hands.

Common Bile Duct Diseases↗

Surgical correction of cervical hyperextension in rigid spine syndrome.

The rigid spine syndrome is a condition characterized by a mild axial and proximal myopathy in which the fibrous shortening of spinal extensor muscles causes a marked limitation in flexion of the spine. This 10-year-old boy with rigid spine syndrome showed a progressive limitation in flexion of the cervical spine with fixed hyperextension of the neck. To look forward he had to bend forward his trunk flexing hips and knees. An X-ray study demonstrated a progressive limitation in flexion but also in extension of the cervical spine. A particular radiologic aspect named "Alligator sign" was demonstrated. The hyperextension of the neck was corrected surgically by opening the interspinous spaces from C2 to C7 through a capsulotomy. The correction was stabilized with bone grafts fixed to the spinous processes. This boy with the straightened cervical spine was then able to look forward without any compensatory posture.

Cervical Vertebrae↗

Congenital muscular dystrophy and rigid spine syndrome.

In three patients with muscular dystrophy, the unexpected occurrence of spinal stiffness suggested a diagnosis of rigid spine syndrome. One case belongs to the benign form of the congenital muscular dystrophies; in the other cases however, the severity and the distribution of the muscular process, associated with neurological abnormalities, seems to correspond to a unique variant of congenital muscular dystrophy. These observations underline the heterogeneity of the rigid spine syndrome.

Brain↗

A first principles simulation of rigid water.

We present the results of Car-Parrinello (CP) simulations of water at ambient conditions and under pressure, using a rigid molecule approximation. Throughout our calculations, water molecules were maintained at a fixed intramolecular geometry corresponding to the average structure obtained in fully unconstrained simulations. This allows us to use larger time steps than those adopted in ordinary CP simulations of water, and thus to access longer time scales. In the absence of chemical reactions or dissociation effects, these calculations open the way to ab initio simulations of aqueous solutions that require time scales substantially longer than presently feasible (e.g., simulations of hydrophobic solvation). Our results show that structural properties and diffusion coefficients obtained with a rigid model are in better agreement with experiment than those determined with fully flexible simulations. Possible reasons responsible for this improved agreement are discussed.

Journal Article↗

Quantum effects in light and heavy liquid water: A rigid-body centroid molecular dynamics study.

The centroid molecular dynamics (CMD) method is applied to the study of liquid water in the context of the rigid-body approximation. This rigid-body CMD technique, which is significantly more efficient than the standard CMD method, is implemented on the TIP4P model for water and used to examine isotopic effects in the equilibrium and dynamical properties of liquid H(2)O and D(2)O. The results obtained with this approach compare remarkably well with those determined previously with path integrals simulations as well as those obtained from the standard CMD method employing flexible models. In addition, an examination of the impact of quantization on the rotational and librational motion of the water molecule is also reported.

Journal Article↗

Monte Carlo simulations of rigid biopolymer growth processes.

Rigid biopolymers, such as actin filaments, microtubules, and intermediate filaments, are vital components of the cytoskeleton and the cellular environment. Understanding biopolymer growth dynamics is essential for the description of the mechanisms and principles of cellular functions. These biopolymers are composed of N parallel protofilaments which are aligned with arbitrary but fixed relative displacements, thus giving rise to complex end structures. We have investigated rigid biopolymer growth processes by Monte Carlo simulations by taking into account the effects of such "end" properties and lateral interactions. Our simulations reproduce analytical results for the case of N = 2, which is biologically relevant for actin filaments. For the case of N = 13, which applies to microtubules, the simulations produced results qualitatively similar to the N = 2 case. The simulation results indicate that polymerization events are evenly distributed among the N protofilaments, which imply that both end-structure effects and lateral interactions are significant. The effect of different splittings in activation energy has been investigated for the case of N = 2. The effects of activation energy coefficients on the specific polymerization and depolymerization processes were found to be unsubstantial. By expanding the model, we have also obtained a force-velocity relationship of microtubules as observed in experiments. In addition, a range of lateral free-energy parameters was found that yields growth velocities in accordance with experimental observations and previous simulation estimates for the case of N = 13.

Actin Cytoskeleton↗

Effective electrostatic interactions in solutions of polyelectrolyte stars with rigid rodlike arms.

In solutions of star-branched polyelectrolytes, electrostatic interactions between charged arms on neighboring stars can compete with intrastar interactions and rotational entropy to induce anisotropy in the orientational distribution of arms. We explore the influence of arm orientational anisotropy on effective star-star interactions for model stars comprising rigid rodlike arms with evenly spaced charged monomers interacting via an effective screened-Coulomb (Yukawa) potential. Monte Carlo simulation and density-functional theory are used to compute the arm orientational distributions and effective pair potentials between weakly charged stars. For comparison, a torque balance analysis is performed to obtain the configuration and energy of the ground state, in which the torque vanishes on each arm of the two-star system. The degree of anisotropy is found to increase with the strength of electrostatic interactions and proximity of the stars. As two stars begin to overlap, the forward arms are pushed back by interstar arm-arm repulsion, but partially interdigitate due to rotational entropy. At center-center separations approaching complete overlap, the arms relax to an isotropic distribution. For nonoverlapping stars, anisotropy-induced changes in the intra- and interstar arm-arm interactions largely cancel and the effective pair interactions are then well approximated by a simple Yukawa potential, as predicted by linear-response theory for a continuum model of isotropic stars [A. R. Denton, Phys. Rev. E 67, 11804 (2003)]. For overlapping stars, the effective pair interactions in the simple rigid-arm-Yukawa model agree closely with simulations of a molecular model that includes flexible arms and explicit counterions [A. Jusufi et al., Phys. Rev. Lett. 88, 018301 (2002); J. Chem. Phys. 116, 11011 (2002)].

Journal Article↗

The dependence of nanostructures on the molecule rigidity of A2(B4)2-type miktoarm block copolymer.

Using the dissipative particle dynamics simulation technique, we have studied the influence of the molecule rigidity on the nanostructures of the A2(B4)2-type miktoarm block copolymers. A typical spherical micellar ordered structure is obtained for a coil-coil miktoarm block copolymer in melt. By introducing a bond angle potential in our model to enhance the molecule rigidity systematically, we find, respectively, a hexagonal cylindrical structure and a parallel ellipsoid in lamellae structure which is discovered for the first time.

Journal Article↗

A comparison of rigid and flexible water models in collisions of monomers and small clusters.

In this study we have investigated the dynamics of small water clusters using microcanonical molecular dynamics simulations. The clusters are formed by colliding vapor monomers with target clusters of two and five molecules. The monomers are sampled from a thermal ensemble at T=300 K and target clusters with several total energies are considered. We compare rigid extended simple point charge water with flexible counterparts having intramolecular harmonic bonds with force constants 10(3) and 10(5) kcal(mol A2). We show that the lifetimes of the clusters formed via collision process are similar for the rigid model and the flexible model with the bigger force constant, if the translational temperatures of the target cluster molecules are equal. The model with the smaller force constant results in much longer lifetimes due to the stabilizing effect caused by the kinetic energy transfer into internal vibration of the molecules. This process may take several hundreds of picoseconds, giving rise to time-dependent decay rates of constant-energy clusters. A study of binary collisions of water molecules shows that the introduction of flexibility to the molecules increases the possibility of dimer formation and thus offers an alternative route for dimer production in vapors. Our results imply that allowing for internal degrees of freedom is likely to enhance gas-liquid nucleation rates in water simulations.

Journal Article↗