PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “surface modification”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66Linked to original sources

Chemical graft polymerization of sulfobetaine monomer on polyurethane surface for reduction in platelet adhesion.

Surface modification is an effective way to improve the hemocompatibility and remain bulk properties of biomaterials. Recently, polymer tailored with zwitterions was found having good blood compatibility. In this study, the zwitterionic monomer of sulfobetaine was graft polymerized onto polyurethane (PU) surface in a three-step heterogenous system through the vinyl bonds of acrylic acid (AA) or hydroxyethyl methacrylate (HEMA), which was immobilized with hexamethylene diisocyanate (HDI) beforehand. First, PU was activated with isocyanate groups using HDI as coupling agent. Second, AA or HEMA was introduced through reaction of AA or HEMA with NCO groups bonded on PU surface. Last, zwitterionic monomer of sulfobetain was graft polymerized with vinyl group of AA or HEMA using AIBN as polymerization initiator. The reaction process was monitored with ATR-IR spectra and XPS spectra. Variation of graft yield with temperature and monomer feed concentration was investigated and feasible conditions were optimized. The wettability of films was investigated by water contact angle measurement and water absorbance. Platelet adhesion experiment was conducted as a preliminary test to confirm the improved blood compatibility of PU. The number of platelets adhering to PU decreased greatly comparing with the originals after 1 and 3 h of contact with human plate-rich plasma (PRP).

Acrylates↗

Bio-/haemocompatibility: implications and outcomes for sensors?

Sensors are a sample contacting technology, and when exposed to biological matrices tend to suffer from the problem of poor biocompatibility and surface fouling. The effects are evidenced by time dependent signal drift (particularly for those devices which are implanted intravascularly). Practical methods to reduce such effects require an understanding of the interface between the electrode and its environment prior to assessment of the potential areas for improvement. Current procedures employed to overcome the observed losses in electrode sensitivity (following exposure to whole blood) include surface modification of the outer diffusion limiting membrane (via variation in film porosity) or even biomimicry of the fluid cell membrane. At amperometric electrodes incorporation of additional inner perm-selective membranes has achieved a reduction in electrode passivation from undesirable surface active compounds as has the use of low polarisation potentials. Other studies have attempted to induce an aqueous barrier between the matrix and the electrode tip which physically prevents passage of cellular components from the sensor surface. Careful choice of the system and materials will ultimately lead to biocompatible non-fouling devices capable of functioning in an array of bio-environments suitable for clinical monitoring of the critically ill patient.

Biocompatible Materials↗

In vitro and in vivo studies of PEO-grafted blood-contacting cardiovascular prostheses.

The initial step of thrombus formation on blood-contacting biomaterials is known to be adsorption of blood proteins followed by platelet adhesion. Poly(ethylene oxide) (PEO) has been frequently used to modify biomaterial surfaces to minimize or prevent protein adsorption and cell adhesion. PEO was grafted onto a number of biomaterials in our laboratory. Nitinol stents and glass tubes were grafted with PEO by priming the metal surface with trichlorovinylsilane (TCVS) followed by adsorption of Pluronic and y-irradiation. Nitinol stents were also coated with Carbothane for PEO grafting. Chemically inert polymeric biomaterials, such as Carbothane, polyethylene, silicone rubber, and expanded polytetrafluoroethylene (e-PTFE), were first adsorbed with PEO-polybutadiene-PEO (PEO-PB-PEO) triblock copolymers and then exposed to gamma-irradiation for covalent grafting. For PEO grafting to Dacron (polyethylene terephthalate), the surface was sequentially treated with PEO-PB-PEO and Pluronics followed by gamma-irradiation. In vitro studies showed substantial reduction in fibrinogen adsorption and platelet adhesion to the PEO-grafted surfaces compared with control surfaces. Fibrinogen adsorption was reduced by 70-95% by PEO grafting on all surfaces, except for e-PTFE. The platelet adhesion corresponded to the fibrinogen adsorption. When the PEO-grafted surfaces were tested ex vivo/in vivo, however, the expected beneficial effect of PEO grafting was inconsistent. The beneficial effect of the PEO grafting was most pronounced on the PEO-grafted nitinol stents. Thrombus formation was reduced by more than 85% by PEO grafting on metallic stents. Only moderate improvement (i.e. 35% decrease in platelet deposition) was observed with PEO-grafted tubes of polyethylene, silicone rubber, and glass. For PEO-grafted heart valves made of Dacron, however, no effect of PEO grafting was observed at all. It appears that the extent of thrombus formation on PEO-grafted biomaterials was directly related to the extent of tissue damage during implantation surgery. Platelets can be activated and form aggregates in the bulk blood, and the formed platelet aggregates may be able to deposit on the PEO monolayer overcoming its repulsive property. Our studies indicate that the testing of in vitro platelet adhesion should include adhesion of large platelet aggregates, in addition to adhesion of individual platelets. Furthermore, the surface modification methods should be improved over the current monolayer grafting concept so that the repulsive force by the grafted PEO layers is large enough to prevent adhesion of platelet aggregates formed in the bulk blood before arriving at the biomaterial surface.

Adsorption↗

Adsorption/desorption phenomena on pure and Teflon AF-coated titania surfaces studied by dynamic contact angle analysis.

As a result of inflammatory processes, plaque formation on dental titanium implants often leads to clinically pathogenic situations. This special biofilm formation on (bio)materials in contact with saliva is initiated by ionic and protein interactions. In this interfacial process, albumin becomes a main constituent of dental pellicle. Interfacial reactions change the surface characteristics. They determine the following steps of macromolecular adsorption and bacterial adhesion. This work focuses on the dynamic contact angle analysis (DCA), which is a tool for online measurements of dynamic changes of wettability without disturbing the interface during detection. Repeatability of the DCA method has been assessed according to the Bland and Altman method. The kinetics and equilibrium data of shifts in the wetting tension hysteresis indicate ionic influences at the titanium/bovine serum albumin (BSA) interface: the Ca-mediated increase of the BSA adsorption on titanium and the adsorption maximum at the isoelectric point (IEP) of BSA. Ti was surface modified by Teflon AF polymeric coatings. The result of the assessment gives reason to consider Teflon AF as a reference material for DCA repeatability studies. This surface modification caused drastic changes in the dynamic interfacial reactions. Shifts in the wetting tensions during DCA adsorption-desorption experiments clearly demonstrated the partially irreversible adsorption of BSA on Teflon AF. In contrast, reversible adsorption behavior was detected on pure Ti surfaces. These findings strengthen the hypothesis that the analysis of dynamic changes in wetting tension and wetting tension hysteresis is a sensitive analytical method for the detection of dynamic interfacial changes at biomaterial/biosystem interfaces during the initial steps of biofilm formation.

Adsorption↗

Hydroxypropyl cellulose as an adsorptive coating sieving matrix for DNA separations: artificial neural network optimization for microchip analysis.

Effective DNA separations in microelectrophoretic systems are complicated by the need to passivate the surface dynamically or covalently. We describe the optimization and utilization of a novel buffer system for fast DNA separations by capillary and microchip electrophoresis without the need for any surface modification or conditioning prior to separation. At concentrations as high as 5%, hydroxypropyl cellulose (HPC) has a relatively low viscosity, allowing for microchip channel filling to be performed with ease. A MES/TRIS buffer system at pH 6.1 eliminates the need for surface preconditioning procedures due to the promotion of hydrogen bonding of HPC with the wall. An additional benefit with this buffer system is the low current observed at high fields when compared to other common DNA separation buffers. An artificial neural network (ANN) was used to model the data and to predict the optimum conditions. Utility of the ANN-optimized system for molecular diagnostic testing was demonstrated by performing microchip separations on DNA samples from patients suspected of having genetic mutations associated with Duchenne muscular dystrophy (DMD). Microchip analysis easily allowed for the patient samples positive for DMD mutations to be distinguished from patient samples negative for the disease.

Adsorption↗

A blank slate? Layer-by-layer deposition of hyaluronic acid and chitosan onto various surfaces.

Although poly(alpha-hydroxy esters), especially the PLGA family of lactic acid/glycolic acid copolymers, have many properties which make them promising materials for tissue engineering, the inherent chemistry of surfaces made from these particular polymers is problematic. In vivo, they promote a strong foreign-body response as a result of nonspecific adsorption and denaturation of serum proteins, which generally results in the formation of a nonfunctional fibrous capsule. Surface modification post-production of the scaffolds is an often-utilized approach to solving this problem, conceptually allowing the formation of a scaffold with mechanical properties defined by the bulk material and molecular-level interactions defined by the modified surface properties. A promising concept is the so-called "blank slate": essentially a surface that is rendered resistant to nonspecific protein adsorption but can be readily activated to covalently bind bio-functional molecules such as extracellular matrix proteins, growth factors or polysaccharides. This study focuses on the use of the quartz crystal microbalance (QCM) to follow the layer-by-layer (LbL) electrostatic deposition of high molecular weight hyaluronic acid and chitosan onto PLGA surfaces rendered positively charged by aminolysis, to form a robust, protein-resistant coating. We further show that this surface may be further functionalized via the covalent attachment of collagen IV, which may then be used as a template for the self-assembly of basement membrane components from dilute Matrigel. The response of NIH-3T3 fibroblasts to these surfaces was also followed and shown to closely parallel the results observed in the QCM.

3T3 Cells↗

Cationic silica nanoparticles as gene carriers: synthesis, characterization and transfection efficiency in vitro and in vivo.

The potential of cationic SiO2 nanoparticles was investigated for in vivo gene transfer in this study. Cationic SiO2 nanoparticles with surface modification were generated using amino-hexyl-amino-propyltri-methoxysilane (AHAPS). The zeta potential of the nanoparticles at pH = 7.4 varied from -31.4 mV (unmodified particles; 10 nm) to +9.6 mV (modified by AHAPS). Complete immobilization of DNA at the nanoparticle surface was achieved at a particle ratio of 80 (w/w nanoparticle/DNA ratio). The surface modified nanoparticle had a size of 42 nm with a distribution from 10-100 nm. The ability of these particles to transfect pCMVbeta reporter gene was tested in Cos-1 cells, and optimum results were obtained in the presence of FCS and chloroquine at a particle ratio of 80. These nanoparticles were tested for their ability to transfer genes in vivo in the mouse lung, and a two-times increase in the expression levels was found with silica particles in comparison to EGFP alone. Very low or no cell toxicity was observed, suggesting silica nanoparticles as potential alternatives for gene transfection.

Animals↗

Collagen/apatite coating on 3-dimensional carbon/carbon composite.

A three-dimensional carbon/carbon composite (3D C/C) was studied as potential bone-repairing material; its major mechanical properties were found to be closer to those of human bone than other common bone-repairing materials available. In vitro calcification tests revealed that as-received 3D C/C is almost bioinert in simulated body fluid (SBF) over an immersion period of 4 weeks. To improve the bioactivity of 3D C/C, surface modification was accomplished through two practical routes: (1) grafting with polyethylene glycol (PEG) and (2) phosphorylation and precalcification. After grafting with alpha, omega di(aminopropyl) polyethylene glycol 800 (NH2-PEG-NH2), a continuous layer of calcium phosphate was formed on the surface of 3D C/C in SBF after 4 weeks. Phosphorylated 3D C/C samples have the ability to induce apatite precipitation after precalcification in a saturated Ca(OH)2 solution for 1 week. To speed up the coating process, a calcification solution with collagen was developed in which a collagen/apatite coating layer can be formed on 3D C/C in 9 h in ambient conditions.

Apatites↗

A novel method for depositing erythroid cells onto glass slides for fetal cell analysis.

BACKGROUND: We have developed a method for selecting erythroblasts from blood, the first step toward identifying fetal cells in maternal blood for diagnostic purposes. Because the selection method results in a large number of positive cells, we needed to develop new methods to deposit the cells onto slides and to modify in situ hybridization procedures to enable detection of fetal cells. METHODS: We utilized Nunc flaskettes to increase the slide surface area available for cell deposition. The ability of erythroid lineage cells to adhere to several surface modifications was examined. In situ hybridization methods were tested to find the best approach that is compatible with these cell preparations. RESULTS: The best glass slide coating for erythroid cells was found to be an antibody to glycophorin A, a red cell surface antigen. We were able to get excellent in situ hybridization signals in cells on flaskettes by modifying fixation and pretreatment parameters. CONCLUSIONS: The methods described here appear to be the best way of attaching a large number of erythroid lineage cells to slides and of detecting them by in situ hybridization.

Antibodies, Monoclonal↗

Covalent micropatterning of poly(dimethylsiloxane) by photografting through a mask.

A new photografting method to micropattern a covalent surface modification on poly(dimethylsiloxane) (PDMS) provides advantages in simplicity and efficiency. To accomplish the entire process on the benchtop, the PDMS was initially treated with benzophenone dissolved in a water/acetone mixture. This process permitted limited diffusion of the photoinitiator into the PDMS surface. Polymerization of acrylic acid was initiated by exposure of the benzophenone-implanted PDMS to UV radiation through a photomask with a thin aqueous layer of acrylic acid sandwiched between the PDMS and photomask. This procedure resulted in patterned poly(acrylic acid) (PAA) on the PDMS surface. In the modified regions, PAA and PDMS formed an interpenetrating polymer network extending 50 microm into the PDMS with an X-Y spatial resolution of 5 microm. The carboxyl groups of the PAA graft could be derivatized to covalently bond other molecules to the patterned PAA. Two bioanalytical applications of this micropatterned surface were demonstrated: (1) a guide for cell attachment and growth and (2) a substrate for immunoassays. 3T3 cells were shown to selectively localize to modified surface regions where they could be cultured for up to 7 days. Additionally, the micropatterned surface was used to immobilize either protein A or antibody for heterogeneous immunoassays.

Acrylic Resins↗

Chemical force titrations of amine- and sulfonic acid-modified poly(dimethylsiloxane).

Chemical force titrations-measurements of the adhesive interaction between a pair of suitably chemically modified atomic force microscopy (AFM) tip and sample surfaces as a function of pH-have been carried out for various combinations of silanol, amine, carboxylic acid, and sulfonic acid functional groups on both tip and sample. The primary surface material studied was poly(dimethylsiloxane) (PDMS). Surface modification was carried out using a plasma oxidation process to form silanol sites; further modification with amine or sulfonic acid sites was carried out by reaction of the silanol sites with the appropriate trialkoxysilane derivative. AFM tips were also modified using trialkoxysilane compounds. In the cases of tip/sample combinations with the same functional group on each, surface pK(1/2) values could be determined. In several "mixed" tip/sample combinations, a peak appeared in the titration curve midway between the surface pK(1/2) values of the tip and sample, consistent with an ionic H-bonding model for the interactions. The amine/sulfonic acid pair showed more complex behavior; the amine-terminated tip/sulfonic acid-terminated PDMS surface force titration curve consisted of two peaks centered at pH 4 and pH 8. Reversing the tip/sample pair resulted in the peak positions being shifted upward by 1.0 pH unit. The peak appearing at lower pH is assigned to electrostatic interactions between the two oppositely charged surfaces, whereas the higher pH peak is believed to arise due to ionic H-bonding interactions. AFM images show the effects on surface patterning of amine- and sulfonic acid-modified PDMS surfaces that have undergone two different oxidation methods (air plasma oxidation and Tesla coil oxidation). The surface morphologies of freshly prepared and 24 h aged air plasma oxidized PDMS are also discussed in this study.

Journal Article↗

Effect of bleaching agents on the fluoride release and microhardness of dental materials.

The use of bleaching agents has become a popular procedure for whitening teeth. Recently introduced polyacid-modified composite resins (compomers) have several favorable features, such as improved physical properties and fluoride release. Because these two materials have many possibilities to interact in the oral cavity during dental treatment, it is necessary to understand such interaction. To evaluate the effect of a bleaching agent on dental restoratives, three compomers were photopolymerized and then bleached for 1, 2, 3 and 5 days with the use of 30% hydrogen peroxide. Fluoride release, surface microhardness, and surface modifications were evaluated. It was found that the cumulative fluoride release was found to be linearly correlated to the tested periods of bleaching in all compomers. Among the tested compomers, F2000 showed the highest cumulative fluoride release. Bleached compomers became soft because of surface degradation, so the surface microhardness decreased. F2000 showed an apparent crack formation that was not observed in other compomers. The nearly linear correlation between the filler content and microhardness was found in the control samples. However, the same correlation was not observed after the compomers were stored in a bleaching agent or distilled water.

Compomers↗

Enhanced surface hardness by boron implantation in Nitinol alloy.

Boron implantation into Nitinol alloy has a potential for developing improved Nitinol root canal instruments with excellent cutting properties, without affecting their superelastic bulk-mechanical properties. The surface hardness of nickel-titanium (NiTi) alloy, also known as "Nitinol" (50 atm% nickel+50 atm% titanium), has been improved by ion-beam surface modification. With an implantation dose of 4.8 x 10(17) boron/cm2, a high concentration of boron (30 atm%) is incorporated into NiTi alloy by 110 keV boron ions at room temperature (25 degrees C). Boron-implanted and unimplanted (pure) Nitinol alloys show surface hardness of 7.6 +/- 0.2 and 3.2 +/- 0.2 GPa, respectively, at the nanoindentation depth of 0.05 micron. The ion-beam-modified NiTi alloy exceeds the surface hardness of stainless steel.

Boron↗

A nonviral DNA delivery system based on surface modified silica-nanoparticles can efficiently transfect cells in vitro.

Diverse polycationic polymers have been used as nonviral transfection agents. Here we report the ability of colloidal silica particles with covalently attached cationic surface modifications to transfect plasmid DNA in vitro and make an attempt to describe the structure of the resulting transfection complexes. In analogy to the terms lipoplex and polyplex, we propose to describe the nanoparticle-DNA complexes by the term "nanoplex". Three batches, Si10E, Si100E, and Si26H, sized between 10 and 100 nm and with zeta potentials ranging from +7 to +31 mV at pH 7.4 were evaluated. The galactosidase expression plasmid DNA pCMVbeta was immobilized on the particle surface and efficiently transfected Cos-1 cells. The transfection activity was accompanied by very low cytotoxicity, with LD(50) values in the milligrams per milliliter range. The most active batch, Si26H, was produced by modification of commercially available silica particles with N-(6-aminohexyl)-3-aminopropyltrimethoxysilane, yielding spherical nanoparticles with a mean diameter of 26 nm and a zeta potential of +31 mV at pH 7.4. Complexes of Si26H and pCMVbeta plasmid DNA formed at w/w ratios of 10 were most effective in promoting transfection of Cos-1 cells in the absence of serum. At this ratio, >90% of the DNA was associated with the particles, yielding nanoplexes with a net negative surface charge. When the transfection medium was supplemented with 10% serum, maximum gene expression was observed at a w/w ratio of 30, at which the resulting particle-DNA complexes possessed a positive surface charge. Transfection was strongly increased in the presence of 100 microM chloroquine in the incubation medium and reached approximately 30% of the efficiency of a 60 kDa polyethylenimine. In contrast to polyethylenimine, no toxicity was observed at the concentrations required. Atomic force microscopy of Si26H-DNA complexes revealed a spaghetti-meatball-like structure. The surface of complexes prepared at a w/w ratio of 30 was dominated by particles half-spheres. Complex sizes correlated well with those determined previously by dynamic light scattering.

Animals↗

Surface labelling of senescent chick fibroblasts by lactoperoxidase-catalysed iodination.

Cell surface of chick fibroblasts were labelled by a short treatment with 125I in presence of lactoperoxidase. A glycoprotein (220,000 molec. wt) was iodinated and was present in a more exposed position or in greater amounts at the surface of old phase III cells compared to young phase II cells. The findings extend our previous observations on cell surface modifications in in vitro senescing fibroblasts.

Aging↗

Effects of branching and molecular weight of surface-bound poly(ethylene oxide) on protein rejection.

To understand better the origin of protein rejection observed with surface-bound poly(ethylene oxide) (or PEO), we have measured fibrinogen adsorption for a series of linear and branched, low-molecular-weight PEOs bound to solid polystyrene surfaces. The results show that a dependence on molecular weight is found below 1500 g mol-1 for linear PEO. Branched PEOs are less effective at protein rejection than linear PEOs. The branched PEOs have smaller exclusion volumes (from GPC) than the corresponding linear PEOs, consistent with restriction in conformational freedom for the branched compounds. The protein rejection results are interpreted in terms of entropy changes that result upon protein adsorption. In addition, some practical problems in preparation of PEO glycidyl ethers have been clarified, thus making these PEO derivatives more useful for surface modification.

Adsorption↗

Fibronectin adsorption on surface-activated poly(dimethylsiloxane) and its effect on cellular function.

This article reports that surface modification of poly(dimethylsiloxane) (PDMS) influences fibronectin (Fn) adsorption and enhances cell attachment. Controlled adsorption of Fn on chemically activated polymer substrates is known to influence cellular function. Thin films of PDMS were spun cast on silicon wafers to obtain homogeneous and molecularly smooth surfaces. The films were made hydrophilic by exposure to ultraviolet ozone activation (PDMS*). The films then were characterized by contact angle goniometry, ellipsometry, atomic force microscopy (AFM), Rutherford backscattering spectrometry and X-ray photoelectron spectroscopy. Contact angle measurements indicated higher hydrophobicity of the nonactivated PDMS substrates than PDMS*. AFM scans of the substrates indicated higher surface roughness of PDMS* (Ra = 0.55 nm) than PDMS (Ra = 0.25 nm). Although Fn surface density (Gamma) was slightly higher on PDMS than on PDMS*, due to hydrophobic interactions between substrate and Fn, cell function was greatly enhanced on the Fn-coated PDMS* (PDMS*-Fn) than on PDMS (PDMS-Fn). Higher attachment of MC3T3-E1 osteoblast-like cells was observed on PDMS*-Fn than on PDMS-Fn. Moreover, cell spreading and cytoskeleton organization after 72 h was clearly favored on the Fn-coated PDMS* surfaces.

Actins↗

Reversible hydrophobization and lipophobization of cellulose fibers via trifluoroacetylation.

The surface modification of cellulose fibers with trifluoroacetic anhydride (TFAA) was studied using the heterogeneous cellulose/TFAA/pyridine/toluene system. The degree of substitution (DS) of the ensuing trifluoroacetylated fibers ranged from 0.04 to 0.30. This treatment conferred a high degree of both hydrophobicity and lipophobicity on the fibers' surface, even at low DS values. Both the dispersive and the polar contributions to the surface energy were drastically reduced. However, the original cellulose hydrophilicity could be readily restored through hydrolysis, by treating the modified fibers with neutral water.

Acetic Anhydrides↗