PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ATMOSPHERE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67Linked to original sources

Our life is protected by the Earth's atmosphere and magnetic field: what aurora research tells us.

Our sun is an average middle-aged star. Without the sun, there would be no atmosphere, no water, and no life on the Earth. The sun is constantly changing, providing the Earth with energy through a complicated chain of processes that occur in space surrounding the Earth. This paper demonstrates that life on Earth is protected by two barriers, i.e., the atmosphere and the magnetic field, against otherwise menacing events in space. Because of these shielding effects, we, peacefully sitting on the Earth's surface, are not aware of a number of critical and potentially dangerous episodes that are taking place only 100 km above the Earth's surface. The aurora, which dances in the polar sky also because of the two barriers, is sending us a crucial hint about what is happening in space.

Animals↗

Effect of increased atmospheric pressure on radial keratotomy.

PURPOSE: To evaluate the effect of increased atmospheric pressure on visual acuity in patients who have had radial keratotomy (RK). SETTING: Long Beach Memorial Medical Center, Long Beach, California, USA. METHODS: This controlled clinical study comprised 4 eyes that had RK and 4 control eyes that were age and sex matched. All patients had prehyperbaric chamber examinations consisting of manifest and cycloplegic refractions, intraocular pressure (IOP), keratometry, and corneal pachymetry. They were then placed into the hyperbaric chamber for 1 hour. Immediately after the patients were removed from the chamber, the examinations were performed again. RESULTS: No statistically significant changes in visual acuity, refractive error, IOP, keratometry, or pachymetry occurred in the 2 groups. CONCLUSION: The results of this study indicate that, unlike at high altitudes, RK is stable at increased atmospheric pressure. This suggests that RK patients can engage in recreational scuba diving without encountering deleterious visual changes.

Adult↗

Natural atmospherics and occurrence of seizures in six adolescents with epilepsy: a cross correlation study.

As already seen in a former study of 315 epileptic seizures in adults, subsequent investigation of 3333 epileptic seizures in six adolescents revealed a significant increase of the seizure frequency during days with a higher mean frequency of 28 kHz atmospherics, and a decrease during days with a (Baumer apparatus) distinctly higher amount of 10 kHz when compared with the daily mean frequency within the whole period. However, one patient showed an opposite behaviour regarding the correlations of 28 and 10 kHz atmospherics and the mean numbers of seizures.

Adolescent↗

Liquid sample injection using an atmospheric pressure direct current glow discharge ionization source.

An atmospheric pressure DC glow discharge in helium has been used as an ionization source for organic samples introduced by liquid injection into atmospheric pressure ionization mass spectrometry (API/MS). The glow source operates typically in the range up to 1 mA of current at less than 1 kV, although the source can be operated up to a discharge current of 10 mA. Even at the high current used in this work, the protonated molecule, MH+, is observed with little or no fragmentation for many of the samples studied. The detection limits achieved for API glow discharge detection are typically in the low femtomole region for small organic molecules including small biological neurotransmitters, drugs, pesticides, phenylthiohydantoin-substituted amino acids, and explosives. A detection limit of approximately 2 pg has been achieved for tyramine with linear quantitation over at least 3 orders of magnitude. The sensitivity in these experiments has been further improved by optimization of the skimmer-interface system and the liquid injection/nebulization design.

Amino Acid Sequence↗

Detection of cyclic lipopeptide biomarkers from Bacillus species using atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry.

A novel approach to microbial detection using atmospheric pressure matrix-assisted laser desorption/ionization with an ion trap mass spectrometer to analyze whole cell bacteria is introduced. This new approach was tested with lyophilized spores and cultures of Bacillus globigii (BG) grown on agar media for 4 days or longer. At each stage of growth, it was found that biomarkers, identified as cyclic lipopeptides known as fengycin and surfactin, could be detected by pulsed ultraviolet laser irradiation of intact BG cells (approximately 5 mg) cocrystallized with alpha-cyano-4-hydroxycinnamic acid. Furthermore, definitive amino acid sequence information was obtained by performing tandem mass spectrometry on the precursor ions of the cyclic lipopeptides. The investigation was broadened to include the examination of aerosolized BG spores collected from the atmosphere and directly deposited onto double-sided tape. Subsequent analysis of the recovered spores resulted in the production of mass peaks consistent with fengycin. Other Bacillus species were analyzed for comparison and showed mass spectral peaks also identified as originating from various cyclic lipopeptides. Further studies were conducted using a pulsed infrared laser as the excitation source to analyze BG cells (approximately 5 mg) suspended in a matrix of 0.03 M ammonium citrate and glycerol resulting in the production of ions characteristic of fengycin and surfactin.

Aerosols↗

High-performance liquid chromatography-atmospheric pressure photoionization/tandem mass spectrometric analysis for small molecules in plasma.

A generic high-performance liquid chromatography (HPLC) system interfaced with an atmospheric pressure photoionization (APPI) source and a tandem mass spectrometer was developed for the quantitative determination of small molecules in plasma in support of exploratory in vivo pharmacokinetics. This report summarizes the effects of variations in reversed-phase mode HPLC conditions such as mobile-phase flow rate, solvent composition, organic modifier content, and nebulizer temperature on the photoionization efficiency of both clozapine and lonafarnib. The matrix ionization suppression effect on this method was investigated using the postcolumn infusion technique. The procedure was used to quantitate plasma levels following oral administration of 42 drug discovery compounds to rats. The pharmacokinetic results of 42 drug discovery compounds in rats evaluated by both APPI and atmospheric pressure chemical ionization interfaces were found to be well correlated.

Administration, Oral↗

Characterization of hydrophobic peptides by atmospheric pressure photoionization-mass spectrometry and tandem mass spectrometry.

The use of photoionization at atmospheric pressure shows great potential for the mass analysis of large apolar or hydrophobic peptides. Mass spectra that were obtained using this technique showed mainly singly charged ions. While polar peptides spectra do not produce fragment ions, others lead to B-type or C-type in-source fragmentation. These dissociation reactions, which could involve electron capture dissociation processes in the case of the C-type ions, are observed for hydrophobic peptides. Both the compatibility of this ionization mode with reversed- or normal-phase liquid chromatographic separation and its sensitivity allow liquid chromatography coupling to both mass spectrometry and tandem mass spectrometry for the analyses of hydrophobic peptide mixtures. Atmospheric pressure photoionization seems to be an interesting alternative method to study hydrophobic peptides that are not easily ionizable by more classical ionization techniques such as electrospray ionization and matrix-assisted laser desorption/ionization.

Amino Acid Sequence↗

Atmospheric pressure MALDI with pulsed dynamic focusing for high-efficiency transmission of ions into a mass spectrometer.

The atmospheric pressure (AP) matrix-assisted laser desorption/ionization (MALDI) technique described to date has proven to be a convenient and rapid method for soft ionization of biomolecules. However, this technique, like other AP ionization methods, has so far suffered from a low efficiency in transmitting ions from atmospheric pressure into the vacuum of the mass spectrometer (MS). In this work, a novel technique we termed pulsed dynamic focusing, or PDF, which improves the ion transmission efficiency and sensitivity of AP-MALDI by over an order of magnitude, is described. Pulsed dynamic focusing operates on the basis of pulsing a high-voltage extraction field to zero, when ions are just outside of the MS entrance, to allow the intake gas flow of the MS to effectively entrain the ions into the MS. Results from application of the PDF technique to an AP-MALDI ion trap MS demonstrated that in comparison to static AP-MALDI operation (1). up to 2.1 times more ions from a given laser shot could be transferred into the MS, (2). applying higher voltages in combination with the switching scheme yielded up to 1.6-times-higher ion intensities, and (3). a 3-times-larger laser spot area could be utilized. The combination of these factors produced an enhancement in throughput and sensitivity, as measured by the ions detected per unit time, of over 12 times for a digest sample of bovine serum albumin. In addition, the PDF technique proved to make AP-MALDI less sensitive to laser positioning, creating a more robust ion source in comparison to static AP-MALDI.

Atmospheric Pressure↗

Mass spectrometer characterization of halogen gases in air at atmospheric pressure.

We have developed a new interface for a commercial ion trap mass spectrometer equipped with APCI capable of real-time measurements of gaseous compounds with limits of detection on the order of pptv. The new interface has been tested using the detection of Br2 and Cl2 over synthetic seawater ice at atmospheric pressure as a model system. A mechanical pump is used to draw gaseous mixtures through a glass manifold into the corona discharge area, where the molecules are ionized. Analysis of bromine and chlorine in dry air show that ion intensity is affected by the pumping rate and the position of the glass manifold. The mass spectrometer signals for Br2 are linear in the 0.1-10.6 ppbv range, and the estimated 3sigma detection limit is 20 pptv. The MS signals for Cl2 are linear in the 0.2-25 ppbv range, and the estimated 3sigma detection limit is 1 ppbv. This new interface advances the field of analytical chemistry by introducing a practical modification to a commercially available ion trap mass spectrometer that expands the available methods for performing highly specific and sensitive measurements of gases in air at atmospheric pressure.

Air↗

Atmospheric pressure MALDI-fourier transform mass spectrometry.

The coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) with Fourier transform mass spectrometry (FTMS) is described, and its significance for the high-resolution analysis of complex peptide mixtures is demonstrated. High kinetic energy and extensive metastable decay characteristic of ions generated by vacuum MALDI have been known to constitute a possible obstacle to high-resolution analysis by FTMS. Since the initial coupling of laser desorption techniques with FTMS was realized two decades ago, several different solutions have been proposed to control the energy of the ions and fulfill the promise of high sensitivity and high resolution offered by this analytical method. Initial results obtained on quadrupole time-of-flight and ion trap analyzers have shown that ions generated by MALDI at atmospheric pressure are intrinsically less energetic than those provided by vacuum MALDI. Our report indicates that this characteristic is particularly beneficial for FTMS applications in which a sharp reduction of metastable decay can make larger ion currents available for detection and possible tandem experiments. In our hands, AP MALDI-FTMS has enabled the analysis of complex peptide mixtures with resolution and accuracy comparable to those obtained by analogous electrospray ionization-FTMS experiments, with no evidence of either metastable decomposition or significant formation of matrix adducts. Analysis of a trypsin digest of bovine serum albumin provided signal-to-noise ratios and limits of detection similar to those obtained by ion trap analyzers, but with unmatched resolution and accuracy. AP MALDI has been shown to provide stable precursor ions in amounts that allowed for informative tandem experiments. Finally, the potential of AP MALDI-FTMS for the high-resolution screening of complex mixtures was demonstrated by the analysis of isobaric peptides differing in mass by less than 0.04 Da.

Animals↗

Electrosonic spray ionization. A gentle technique for generating folded proteins and protein complexes in the gas phase and for studying ion-molecule reactions at atmospheric pressure.

Electrosonic spray ionization (ESSI), a variant on electrospray ionization (ESI), employs a traditional micro ESI source with supersonic nebulizing gas. The high linear velocity of the nebulizing gas provides efficient pneumatic spraying of the charged liquid sample. The variable electrostatic potential can be tuned to allow efficient and gentle ionization. This ionization method is successfully applied to aqueous solutions of various proteins at neutral pH, and its performance is compared to that of the nanospray and micro ESI techniques. Evidence for efficient desolvation during ESSI is provided by the fact that the peak widths for various multiply charged protein ions are an order of magnitude narrower than those for nanospray. Narrow charge-state distributions compared to other ESI techniques are observed also; for most of the proteins studied, more than 90% of the protein ions can be accumulated in one charge state using ESSI when optimizing conditions. The fact that the abundant charge state is normally as low or lower than that recorded by ESI or nanospray indicates that folded protein ions are generated. The sensitivity of the ionization technique to high salt concentrations is comparable to that of nanospray, but ESSI is considerably less sensitive to high concentrations of organic additives such as glycerol or 2-amino-2-(hydroxymethyl)-1,3-propanediol (Tris base). Noncovalent complexes are observed in the case of myoglobin, protein kinase A/ATP complex, and other proteins. The extent of dissociation of protein ions in ESSI is comparable to or even smaller than that in the case of nanospray, emphasizing the gentle nature of the method. The unique features of ESSI are ascribed to very efficient spraying and the low internal energy supplied to the ions. Evidence is provided that the method is capable of generating fully desolvated protein ions at atmospheric pressure. This allows the technique to be used for the study of ion-molecule reactions at atmospheric pressure and examples of this are shown.

Atmospheric Pressure↗

Continuous real-time analysis of products from the reaction of some monoterpenes with ozone using atmospheric sampling glow discharge ionization coupled to a quadrupole ion trap mass spectrometer.

An on-line technique has been demonstrated for the analysis of photochemical oxidation reaction products. The technique is based on the direct introduction of gas and particulate oxidation products into a custom-built atmospheric sampling glow discharge ionization source (ASGDI) coupled to a quadrupole ion trap mass spectrometer (QITMS). Operational parameters of the ASGDI system were investigated to determine their influence on the ion signal for the analysis of oxidation products in real time. These parameters include the discharge current, ion accumulation time, and type of reagent gas. Reference mass spectra from standards were generated for a variety of biogenic compounds and terpene reaction products containing keto, hydroxy, aldehyde, carboxylic acid, or epoxy groups to better understand the fragmentation that occurs in the glow discharge ion source. Results are presented for ozonolysis reactions of four biogenic monoterpenes (alpha-pinene, beta-pinene, D-limonene, Delta(3)-carene) monitored with the ASGDI quadrupole ion trap to demonstrate the ability to obtain real-time measurements. The reaction products identified with ASGDI-QITMS correspond to those products identified with other techniques, including on-line atmospheric pressure chemical ionization techniques. Efficient differentiation of multifunctional products including mono-/di-/hydroxy-/keto-carboxylic acid and keto-/hydroxy-aldehyde was possible by use of the MS/MS capability of the instrument.

Atmosphere↗

Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments.

Direct analysis of samples using atmospheric pressure ionization (API) provides a more rapid method for analysis of volatile and semivolatile compounds than vacuum solids probe methods and can be accomplished on commercial API mass spectrometers. With only a simple modification to either an electrospray (ESI) or atmospheric pressure chemical ionization (APCI) source, solid as well as liquid samples can be analyzed in seconds. The method acts as a fast solids/liquid probe introduction as well as an alternative to the new direct analysis in real time (DART) and desorption electrospray ionization (DESI) methods for many compound types. Vaporization of materials occurs in the hot nitrogen gas stream flowing from an ESI or APCI probe. Ionization of the thermally induced vapors occurs by corona discharge under standard APCI conditions. Accurate mass and mass-selected fragmentation are demonstrated as is the ability to obtain ions from biological tissue, currency, and other objects placed in the path of the hot nitrogen stream.

Atmospheric Pressure↗

Capillary electrochromatography coupled to atmospheric pressure photoionization mass spectrometry for methylated benzo[a]pyrene isomers.

Benzo[a]pyrene, one of the most carcinogenic PAHs, has 12 monomethylated positional isomers (MBAPs). A strong correlation between the carcinogenicity of these isomers and methyl substitution has been reported. In this study, on-line coupling of capillary electrochromatography (CEC) and atmospheric pressure photoionization mass spectrometry (APPI-MS) provides a unique solution to highly selective separation and sensitive detection of MBAP isomers. The studies indicated that APPI provides significantly better sensitivity compared to electrospray ionization and atmospheric pressure chemical ionization modes of MS. A systematic investigation of APPI-MS detection parameters and CEC separation is established. First, several sheath liquid parameters (including type and concentration of volatile buffers, type and content of organic modifiers, use of dopants and inorganic/organic additives, and sheath liquid flow rate) and APPI-MS spray chamber parameters (capillary voltage, vaporizer temperature, nebulizer pressure) were found to have effects on detection sensitivity as well as the profile of mass spectrum. For example, when ammonium acetate was replaced with acetic acid in the sheath liquid, the MS signal was enhanced as much as 90% and the formation of ammonia adduct was effectively suppressed. Next, the separation of MBAP isomers was conducted on internal tapered columns packed with polymeric C18 stationary phase. With the use of a mobile phase consisting of slightly higher acetonitrile content (90%,v/v) and a small amount of tropylium ion, the analysis times were significantly shortened by 20 min without compromising the resolutions between the isomers. Finally, quantitative aspects of the CEC-APPI-MS method were demonstrated using 7-MBAP as the internal standard. The calibration curves of three of the most carcinogenic isomers, namely, 1-MBAP, 3-MBAP, and 11-MBAP, showed good linearity in the range of 2.5-50 microg/mL with a limit of detection at 400 ng/mL.

Atmospheric Pressure↗

Characterizing electrospray ionization using atmospheric pressure ion mobility spectrometry.

Reduced flow rate electrospray ionization has been proven to provide improved sensitivity, less background noise, and improved limits of detections for ESI-MS analysis. Miniaturizing the ESI source from conventional electrospray to microelectrospray and further down to nanoelectrospray has resulted in higher and higher sensitivity; however, when effects of flow rate were investigated for atmospheric pressure ESI-IMS using a nanospray emitter, a striking opposite result was observed. The general tendency we observed in ESI-IMS was that higher flow rate offered higher ion signal intensity throughout a variety of conditions investigated. Thus, further efforts were undertaken to rationalize these contradictory results. It is well accepted that decreased flow rate increases both ionization efficiency and transmission efficiency, thus improving ion signal in ESI-MS. However, our study revealed that decreased flow rate results in decreased ion signal because ion transfer is constant, no matter how flow rate changes in ESI-IMS. Since ion transfer is constant in atmospheric pressure ESI-IMS, ionization efficiency can be studied independently, which otherwise is not possible in ESI-MS in which both ionization efficiency and transmission efficiency vary as conditions alter. In this article, we present a systematic study of signal intensity and ionization efficiency at various experimental conditions using ESI-IMS and demonstrate the ionization efficiency as a function of flow rate, analyte concentration, and solvent composition.

Atmospheric Pressure↗

Column performance and stability for high-speed vacuum-outlet GC of volatile organic compounds using atmospheric pressure air as carrier gas.

The development of lightweight, portable GC instrumentation is handicapped by the need for compressed carrier gas to drive the separation. The use of air as carrier gas eliminates the need for compressed gas tanks. If a vacuum pump is used to pull carrier gas and injected samples through the column, atmospheric pressure air can be used as carrier gas. Vacuum outlet operation also improves performance for high-speed separations by reducing detector dead time and by shifting optimal carrier gas velocity to higher values. Under vacuum outlet conditions using atmospheric pressure air as carrier gas, a 6-m-long, 0.25-mm-i.d. capillary column can generate approximately 12,500 theoretical plates, and a 12-m-long column can generate approximately 44,000 plates but with a 3-4-fold increase in separation time. The principal issues in column selection for high-speed GC with air as a carrier gas are efficiency and stability. Several bonded and nonbonded stationary phases were evaluated for use with air as carrier gas in the analysis of volatile organic compounds of interest in airmonitoring applications. These include dimethylpolysiloxane, 50% phenyl-50% methyl polysiloxane, 50% cycanopropylphenyl-50% methyl polysiloxane, trifluoropropyl polysiloxane, poly(ethylene glycol), and dicyanoallyl polysiloxane (nonbonded). The dimethyl polysiloxane and the trifluoropropyl polysiloxane columns showed good efficiency and no significant deterioration after 5 days of continuous operation with air as carrier gas. The 50% phenyl-50% methyl polysiloxane and the 50% cycanopropylphenyl-50% methyl polysiloxane columns showed poorer efficiency, and the poly(ethylene glycol) and dicyanoallyl polysiloxane columns showed excessive deterioration in air.

Air↗

Development of multi-ESI-sprayer, multi-atmospheric-pressure-inlet mass spectrometry and its application to accurate mass measurement using time-of-flight mass spectrometry.

The atmospheric pressure sampling nozzle (orifice, heated capillary, or inlet) of a high mass accuracy time-of-flight mass spectrometer (TOF-MS) was modified by replacing its single nozzle with multiple atmospheric pressure nozzles. This allowed multiple streams of liquids to be introduced into the MS in parallel (an electrosprayer for each nozzle), with minimum analyte interactions between the streams. The chemical contents of all liquid streams were analyzed concurrently using a single mass spectrometer. To obtain a higher mass accuracy by providing internal reference on each scan (acquisition) and to evaluate the suitability of TOF-MS for molecular-formula confirmation, a dual-ESI-sprayer, dual-nozzle version of this design was used. The accurate masses of tens of organic compounds in the mass range of 200-3000 Da were measured, and the results were compared with those obtained using dual-sprayer, single-nozzle TOF-MS. A significant improvement in mass accuracy was observed when the former technique was used. Comparison between the mass accuracy using dual-ESI-sprayer, dual-nozzle TOF-MS and that obtained using a double-focusing mass spectrometer operating under chemical ionization (CI) and fast atom bombardment (FAB) shows the suitability of the technique for elemental-composition confirmation. Approximately 85% of samples analyzed had mass errors of less than 5 ppm, and the other 15% had mass errors less than 8 ppm. Using a high-performance liquid chromatography (HPLC) as a device for introduction of one liquid stream (sample) and a syringe pump as a device for introduction of the second liquid stream (reference standard), the accurate mass of a tryptic digest of cytochrome c was measured. The range of mass errors was from -6.1 ppm to +3.6 ppm, a significant improvement over our previously reported mass accuracy for this digest using single-nozzle TOF-MS. The interactions between analytes in the liquid streams also were investigated using a variety of sample-introduction and nozzle-design combinations, including single-ESI-sprayer, single-nozzle; dual-ESI-sprayer, single-nozzle; dual-ESI-sprayer, Y-shaped inlet; and dual-ESI-sprayer, dual-inlet. The results demonstrated that the dual-ESI-sprayer, dual-inlet design provides reference peaks on every acquisition with minimum analyte-reference interaction and, therefore, higher consistent mass accuracy.

Atmospheric Pressure↗

Atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry.

A novel ionization source for biological mass spectrometry is described that combines atmospheric pressure (AP) ionization and matrix-assisted laser desorption/ionization (MALDI). The transfer of the ions from the atmospheric pressure ionization region to the high vacuum is pneumatically assisted (PA) by a stream of nitrogen, hence the acronym PA-AP MALDI. PA-AP MALDI is readily interchangeable with electrospray ionization on an orthogonal acceleration time-of-flight (oaTOF) mass spectrometer. Sample preparation is identical to that for conventional vacuum MALDI and uses the same matrix compounds, such as alpha-cyano-4-hydroxycinnamic acid. The performance of this ion source on the oaTOF mass spectrometer is compared with that of conventional vacuum MALDI-TOF for the analysis of peptides. PA-AP MALDI can detect low femtomole amounts of peptides in mixtures with good signal-to-noise ratio and with less discrimination for the detection of individual peptides in a protein digest. Peptide ions produced by this method generally exhibit no metastable fragmentation, whereas an oligosaccharide ionized by PA-AP MALDI shows several structurally diagnostic fragment ions. Total sample consumption is higher for PA-AP MALDI than for vacuum MALDI, as the transfer of ions into the vacuum system is relatively inefficient. This ionization method is able to produce protonated molecular ions for small proteins such as insulin, but these tend to form clusters with the matrix material. Limitations of the oaTOF mass spectrometer for singly charged high-mass ions make it difficult to evaluate the ionization of larger proteins.

Animals↗