PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Application”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67Linked to original sources

The effect of site of application on the transcutaneous absorption of 17-beta estradiol from a transdermal delivery system (Climara).

OBJECTIVE: The effect of site of application on 17-beta estradiol bioavailability was assessed in an open-label, randomized, crossover study of a once-weekly transdermal estradiol patch (Climara). DESIGN: After placement of a transdermal patch delivering 0.1 mg/day of estradiol on either the buttocks or abdomen, serial plasma samples were obtained over 7 days and for the immediate 24 h after patch removal. Plasma estradiol concentrations were used to estimate pharmacokinetic parameters for the rate and extent of absorption between the two sites. RESULTS: Plasma estradiol concentrations were sustained at premenopausal levels over the week in most subjects. After application on the buttock, mean peak plasma concentration (Cmax) was 125.1% and mean relative bioavailability (AUC(0-168)) was 117.2% of that from the abdomen site. CONCLUSIONS: In summary, the buttocks seem to be an acceptable site for the application for this once-weekly 17-beta estradiol transdermal delivery system. Because the extent of absorption was significantly more for buttock than for abdomen application, this application site may provide an advantage in women who experience menopausal symptoms at the end of the week.

Abdomen↗

Retrospective case series of therapeutic applications of lotrafilcon a silicone hydrogel soft contact lenses.

PURPOSE: To report a series of consecutive cases for which a lotrafilcon A silicone hydrogel soft contact lens was used in therapeutic applications. METHODS: Three practitioners in Spain, Denmark, and Germany supplied 41 consecutive case reports of 39 patients for whom a lotrafilcon A silicone hydrogel soft contact lens was used in therapeutic applications. Applications included erosion or recurrent erosion, bullous keratopathy, corneal edema, corneal dystrophy, neurotrophic corneal ulcer, entropion, and use after corneal surgeries. Practitioners reported their judgments of pain relief, change in corneal signs by slitlamp evaluation, additional complications, and success of therapeutic lens treatment. Twenty cases of completed treatment and 21 cases of ongoing treatment were reported. RESULTS: Complete pain relief was reported for 78% of all cases, with 94% of all cases reporting pain relief of 50% or higher. Corneal signs were restored to normal for 74% of all cases, with 100% of all cases showing at least partial improvement. No additional complications were reported in 83% of all cases. Therapeutic contact lens application was judged fully successful for 71% of all cases, with 93% of all cases showing at least partial improvement. CONCLUSION: The high-oxygen permeable (Dk) lotrafilcon A lens met or exceeded the outcomes reported from historic reports of therapeutic applications of low-Dk soft contact lenses. Although the case reporting conditions vary among the historic studies and from the current study, this study indicates that success may be improved with the lotrafilcon A high-Dk lens.

Adult↗

Steering UNICORE applications with VISIT.

The UNICORE (UNiform Interface to COmputing REsources) software provides a Grid infrastructure together with a computing portal for engineers and scientists to access supercomputer centres from anywhere on the Internet. While UNICORE is primarily designed for the submission and control of batch jobs, it is also feasible to establish an on-line connection between an application and the UNICORE user-client. This opens up the possibility of performing on-line visualization and computational steering of applications under UNICORE control while maintaining the security provided by this system. This contribution describes the design of a steering extension to UNICORE based on the steering toolkit VISIT (VISualization Interface Toolkit). VISIT is a lightweight library that supports bidirectional data exchange between visualizations and parallel applications. As an example application, a parallel simulation of a laser-plasma interaction that can be steered by an AVS/Express application is presented.

Computer Graphics↗

Medical applications with synchrotron radiation in Japan.

In Japan, various medical applications of synchrotron X-ray imaging, such as angiography, monochromatic X-ray computed tomography (CT), radiography and radiation therapy, are being developed. In particular, coronary arteriography (CAG) is quite an important clinical application of synchrotron radiation. Using a two-dimensional imaging method, the first human intravenous CAG was carried out at KEK in May 1996; however, further improvements of image quality are required in clinical practice. On the other hand, two-dimensional aortographic CAG revealed canine coronary arteries as clearly as those on selective CAG, and coronary arteries less than 0.2 mm in diameter. Among applications of synchrotron radiation to X-ray CT, phase-contrast X-ray CT and fluorescent X-ray CT are expected to be very interesting future applications of synchrotron radiation. For actual clinical applications of synchrotron radiation, a medical beamline and a laboratory are now being constructed at SPring-8 in Harima.

Journal Article↗

Theoretical and experimental analysis of air cooling for intracavitary microwave hyperthermia applicators.

An intracavitary microwave antenna array system has been developed and tested for the hyperthermia treatment of prostate cancer at Thayer School of Engineering and Dartmouth-Hitchcock Medical Center. The antenna array consists of a choked dipole antenna inserted into the urethra and a choked dipole antenna eccentrically embedded in a Teflon obturator inserted into the rectum. To prevent unnecessary heating of the healthy tissue that surrounds each applicator, an air cooling system has been incorporated into the rectal applicator. The air cooling system was designed and modeled theoretically using a numerical solution of heat and momentum equations within the applicator, and an analytical solution of the Pennes bioheat equation in tissue surrounding the applicator. The 3-D temperature distribution produced by the air-cooled rectal applicator was measured in a perfused canine prostate.

Animals↗

The use of a current sheet applicator array for superficial hyperthermia: incoherent versus coherent operation.

There are a number of potential advantages to be gained by using an array of applicators in hyperthermia treatments compared with single applicator systems. These advantages include the possibility of greater spatial control of power deposition and conformability to nonplanar sites. Arrays of applicators can be driven either coherently or incoherently. In the case of coherent operation, an added advantage is the ability to steer power deposition by varying the phases of the antennas. In this study, we investigated the relative merits of the two modes of operation when a 2 x 2 planar array of current sheet applicators is used. The effective field size (EFS) of the array was calculated using a Gaussian beam representation of the applicators on a layered model in which the fat layer had its thickness varied. Good agreement was obtained between the square of the electric field distribution (E2) and quantitative experimental results. It is shown that when the planar array is used with a fat layer greater than about 2 mm present, it should be driven incoherently as this results in a significantly larger EFS than that obtained when the array is driven coherently.

Humans↗

A communication server for telemedicine applications.

The telemedicine applications, in some cases, need multipoint-to-multipoint communication. To meet the requirement of telemedicine communication, the development of a medical communication server is proposed in this paper. To make a working, as well as cost-effective, communication platform for the telemedicine applications, a specially designed communication server model is proposed in this work. This server is able to provide an effective multipoint-to-multipoint communication service for any level applications in telemedicine. The implementation program of this server is developed in a Windows'95 environment by using a winsocket. The trial application testing in a telemonitoring system is also presented to demonstrate the feasibility of taking such a structure with the server. By using the architecture of such a communication server in telemedicine applications, the multipoint-to-multipoint communication is easily managed and the communication processes are simplified and well controlled by the server.

Blood Pressure Monitoring, Ambulatory↗

Electron microscopic observations on the lesions of herpes zoster with topical application of interferon.

The lesions of herpes zoster in three patients were investigated electron microscopically before and after topical application of interferon. In the blister, on the 5th to 7th day after its formation, the following were seen: acantholytic cells with virus particles in the nucleus and cytoplasm, multinucleated cells derived from keratinocytes, edematous and degenerated keratinocytes containing virus particles and tonofibrillar materials, macrophages with many large vacuoles, neutrophils, lymphocytes and Langerhans's cells. After the first application of interferon, the findings for keratinocytes were the same as those of before application and keratinocytes were frequently found adjacent to macrophages. The macrophages were large and had numerons large vacuoles in the cytoplasm. After the second application of interferon, virus particles were often seen in the vacuoles of the macrophages in comparison with that before application. In the cytoplasm of macrophages, acantholytic keratinocytes and tonofibrillar materials were phagocytized. Many virus particles were seen in the vacuoles of some acantholytic keratinocytes. It was concluded from these findings that the macrophages accelerated the phagocytotic activity of the virus particles.

Administration, Topical↗

Daily versus intermittent application of high-concentration tacalcitol ointment in combination with low-dose cyclosporin for psoriasis vulgaris.

In this study, we aimed to compare the clinical effectiveness of highly-concentrated tacalcitol ointment daily versus intermittent application in patients with psoriasis vulgaris who simultaneously took a low dose of cyclosporin. All the patients in both groups showed significant improvements, and the patients in the intermittent application group obtained more patient satisfaction in cost performance. The treatment cost of low-dose cyclosporin and intermittent application of highly-concentrated tacalcitol ointment was less than half of that of high-dose cyclosporin and daily application of highly-concentrated tacalcitol ointment. This preliminary study suggests that the combination therapy with low-dose cyclosporin administration and intermittent application of highly-concentrated tacalcitol is effective, safe and provides acceptable costs for the treatment.

Administration, Topical↗

The EMLA patch--a new type of local anaesthetic application for dermal analgesia in children.

The skin application of EMLA cream under a Tegaderm dressing was compared in children with a new combined dressing/local anaesthetic patch--the EMLA patch. The analgesic effect during venepuncture was assessed using a visual analogue scale (patients) and a verbal rating scale (investigator). Skin adhesiveness and incidence of local skin reactions with the two types of application were also studied. The study was designed as an open randomised trial with two parallel groups. Sixty children, aged between 5 and 15 years were evaluated. After a minimum application time of 60 min an intravenous cannula was inserted. There was no difference in analgesia as assessed by the patients or the investigators. Mild discomfort at removal of the occlusive dressing/patch was observed in a few patients, but there was no difference in the adhesiveness of the Tegaderm dressing and the EMLA patch. Only mild local skin reactions (with paleness in the anaesthetised skin area) were observed in both groups. It was concluded that both the EMLA patch and the Tegaderm/EMLA cream dressing provide effective dermal analgesia for venepuncture with a 0.8 mm (outer diameter) cannula. The two types of application were indistinguishable but the ease of application of the patch is a distinct advantage.

Adolescent↗

Bioavailability and absorption kinetics of nicotine following application of a transdermal system.

1. The absolute bioavailability and absorption kinetics of nicotine were investigated in 13 healthy adult male smokers following single and multiple applications of a nicotine transdermal system (NTS), designed to release nicotine at an approximate rate of 1.5 mg h-1 over 24 h. The absorption of nicotine from the single NTS application was calculated with reference to a simultaneous intravenous infusion (i.v.) of deuterium-labelled nicotine. 2. The mean input time (MIT) and mean absorption time (MAT) for nicotine following application of NTS for 24 h were 7.7 and 4.2 h, respectively. 3. Following NTS removal, the mean apparent nicotine elimination half-life was 2.8 h, compared with 2.0 h following i.v. nicotine, reflecting continued absorption of nicotine following NTS removal. 4. The mean amount of nicotine absorbed from the NTS after the 24 h application was 20.9 mg, which represents about 68% of the amount released from the system; the remaining 32% was lost from the system during daily activities. 5. The ratio of AUC values for the metabolite cotinine relative to nicotine was similar whether nicotine was administered transdermally or intravenously. 6. Following i.v. administration, the mean nicotine clearance was 72 l h-1 (coefficient of variation 29%). Since coefficients of variation in AUC values following NTS and i.v. treatments were similar, transdermal administration of nicotine was not associated with increased interindividual variability in plasma nicotine concentrations. 7. No significant changes were seen in the pharmacokinetics of nicotine between single and multiple applications of NTS. 8. As expected from the higher total plasma nicotine concentrations, the incidence of adverse effects was higher following simultaneous intravenous and transdermal administration of nicotine. The most frequently reported systemic side effects were nervousness and headache: mild itching was the most frequent topical effect.

Administration, Cutaneous↗

The application of quality of life.

BACKGROUND: Despite its popularity, to date little systematic work has been done in the application of the quality of life (QOL) concept to persons with intellectual disability (ID) and its impact on individuals and families. This article addresses that need. METHOD: The article summarizes the four application strands suggested by the IASSID SIRG on Quality of Life regarding the application of the QOL concept and discusses critical aspects of each. RESULTS: Examples and guidelines regarding each strand are presented, along with the ongoing need to align conceptualization, application, and research efforts and integrate QOL principles into professional education and training programmes. CONCLUSIONS: The QOL concept is now challenging some of the more traditional views and approaches to ID. These challenges are resulting in modifications and adaptations in current services and supports, along with the need to evaluate the outcomes from the application of QOL principles to persons with ID.

Choice Behavior↗

Disposition of parathion after dermal application in pigs.

Pharmacokinetic parameters of parathion were studied in pigs after intravenous (i.v.) and dermal administration of unlabelled and 14C-parathion. Plasma concentration-time data were subjected to non-compartmental analysis. Intravenous injection studies showed a mean residence time (MRT) of 2.15 h, a body clearance (ClB) of 4.4 l/kg/h and a volume of distribution (Vss) of 9.8 l/kg. Dermal application led to a mean absorption time (MAT) of 78 h, and a bioavailability of 9.9%. Plasma levels of 14C-parathion (parathion + metabolites) were much higher and more persistent than those of parathion itself. After i.v. administration, recovery of 14C-parathion from urine plus faeces was almost 100% within 3 d, while it was less than 20% after dermal application. Ten days after dermal application high 14C concentrations remained in the back skin, i.e. the application area. In skin samples from areas where contamination from the application area could not have occurred, the 14C-parathion concentration was as low as 2 micrograms/g. It is concluded that in view of the low dermal bioavailability for organophosphorus insecticides it is unlikely that pour-on preparations containing these insecticides reach the ectoparasites through absorption and systemic distribution, but rather that this happens after spreading on the surface of the skin.

Absorption↗

Determination in rejected medical school applicants: a 10-year follow-up.

In view of low admission rate to medical schools, a large number of applicants are rejected annually. This population is denied the fulfillment of its occupational goal and must decide either to reapply to medical school or to choose a different occupational path. The present study focused on the possible career paths of rejected applicants, their persistence in reapplication and eventual admittance. The closeness to medicine of the alternative career was examined by two dimensions: the situs and the status. The career paths were viewed with respect to pre-admission cognitive criteria and occupational status of the alternative choices as compared to medicine. The study's random sample comprised one-third of the unaccepted applicants to the Tel-Aviv University School of Medicine for the 1970 academic year. The research follow-up (n = 208) of the applicants was conducted in 1981. The results showed a strong determination on the part of the unaccepted applicants to persist in their choice of medicine: 59% of the subjects reapplied and graduated from medical school either in Israel or in other countries. This group was found to be significantly more persistent in its number of reapplications than subjects who turned to an alternative career path. Thus, persistence was rewarding. When an alternative occupation was chosen, the tendency was towards careers unrelated to medicine but with a similarly high occupational status. No significant differences were found in the pre-admission cognitive criteria between those who studied medicine and those who chose an alternative career. Motivation and determination seemed to be the dominant factors in the attainment of one's choice of medicine as a profession.

Career Choice↗

Stepwise compared with rapid application of vacuum in ventouse extraction procedures.

OBJECTIVE: To compare a one-step (rapid) application of negative pressure (vacuum) with conventional stepwise application for ventouse extraction following a prolonged second stage of labour. DESIGN: Randomised controlled study. SETTING: Teaching Hospital. PARTICIPANTS: Forty-seven women were randomised to the rapid vacuum group and 47 to the stepwise group. MAIN OUTCOME MEASURES: Duration of ventouse procedure, effectiveness of methods of application, morbidity of mother and infant. RESULTS: There was no significant difference in frequency of detachment of the cup after rapid or stepwise application of vacuum. A reduction in mean duration of the ventouse procedure of 6 min was realised without significant difference in maternal or neonatal morbidity. CONCLUSION: Rapid application of vacuum significantly reduces the duration of a ventouse extraction procedure without compromise to efficiency and safety.

Acid-Base Equilibrium↗

Effects of prolonged application of isoprenaline on intracellular free magnesium concentration in isolated heart of rat.

1. The effect of prolonged application of isoprenaline on intracellular free-Mg2+ concentration ([Mg2+]i) was examined by use of 31P-nuclear magnetic resonance (31P-n.m.r.) in rat isolated hearts. Left ventricular pressure (LVP) was simultaneously measured. 2. [Mg2+]i was estimated from the separation of the alpha- and beta-ATP peaks, using the dissociation constant of MgATP 38 microM (established previously). In normal (phosphate-free, Krebs-Henseleit) solution, [Mg2+]i was approximately 0.4 mM. 3. When isoprenaline was applied for 100 min, a transient increase in [Mg2+]i was observed during the initial 25 min, whilst concentrations of ATP ([ATP]) and phosphocreatine ([PCr]) decreased and [Pi] correspondingly increased. During the subsequent 75 min of isoprenaline application, [Mg2+]i decreased below its resting levels. Washout of isoprenaline restored [Mg2+]i and [PCr], but [ATP] remained low. These changes elicited by isoprenaline were not observed in the presence of propranolol, a typical alpha-adrenoceptor blocker. 4. Isoprenaline increased both LVP and heart rate. The increased LVP and heart rate slowly returned to lower values during prolonged application of isoprenaline, but remained higher than those before application. 5. The transient rise in [Mg2+]i elicited by isoprenaline could be attributed to the decrease in [ATP] resulting in a release of Mg2+. The subsequent decrease in [Mg2+]i during the prolonged applications suggests that beta-adrenoceptor stimulation itself facilitates Mg(2+)-extruding mechanism(s).

Adenosine Triphosphate↗

Comparison of skin anesthetic effect of liposomal lidocaine, nonliposomal lidocaine, and EMLA using 30-minute application time.

BACKGROUND: Liposomes are microscopic phospholipid vessels that have been utilized to extend the action of topical medications. Previous studies have demonstrated that liposomal vehicles can prolong the action of a variety of medications, including antifungals, anesthetics, interferon, and antineoplastic agents. OBJECTIVE: The purpose of this study was to examine the degree and duration of anesthesia produced by lidocaine in a liposomal vehicle compared with lidocaine in a nonliposomal vehicle and compared with EMLA. The topical preparations in this study were allowed to contact the skin for a 30-minute period prior to evaluation of anesthetic effectiveness. Unoccluded and Tegaderm-occluded topical preparations were evaluated in two separate arms of the study. MATERIALS AND METHODS: Thirteen healthy volunteers (three male, 10 female) were recruited for the nonocclusion arm of the study. Six healthy volunteers (two male, four female) were recruited for the occlusion arm of the study. Subjects with a history of allergy to lidocaine, a history of seizures, cardiac or respiratory difficulty, pregnant patients, and patients less than 18 years old were excluded. Written informed consent was obtained from all patients prior to testing. The volar forearms of the volunteers were swabbed with isopropyl alcohol and allowed to dry. A template was then utilized to mark 2 x 2-cm squares with a skin marker on both volar forearms. In total, nine squares corresponding to nine test areas were marked. The nine test preparations were applied to the test areas in a double-blinded fashion using a clean swab stick. The test preparations were then allowed to remain on the skin for 30 minutes in either occluded or nonoccluded from depending upon the arm of the study. Following the 30-minute application period, the test preparations were wiped off with clean gauze. Testing for anesthesia was performed by following a previously published method utilizing gentle pinpricks. A new pinprick apparatus was used for each patient. Pinprick testing was performed at 0, 15, 30, 60, and 90 minutes following the end of the 30-minute application period. Patients' responses to the pinprick were recorded in a binary fashion, as being either: 1) totally painless or 0) painfully sharp to any degree. Ten applications of the pinprick were applied randomly across each 2 x 2-cm test area. The number of painless applications of the pinprick out of a total of 10 applications of the pinprick was then recorded for each test area at every particular test time. In total, nine test preparations were evaluated. Analysis of the data was performed by a PhD statistical faculty consultant from the UCLA Mathematics Department. RESULTS: Liposomal lidocaine preparations evidenced longer durations of anesthesia than lidocaine preparations in nonliposomal vehicles. Five percent liposomal lidocaine preparations were statistically equivalent to EMLA in anesthetic effectiveness. CONCLUSION: Five percent liposomal lidocaine is an effective alternative topical agent for use in the attainment of temporary local anesthesia of the skin.

Adult↗

An increase in sinus rate following radiofrequency energy application in the posteroseptal space.

An increase in sinus rate has been previously described in patients with AV node reentry (AVNRT) following successful AV node modification. This increase could either be a specific sign of elimination of slow pathway conduction or it could be a consequence of energy application in the posteroseptal area. Thus, we compared the changes in sinus cycle length following successful slow pathway ablation (defined as complete elimination of dual AV node physiology) in patients having AVNRT with those in patients undergoing successful ablation of a posteroseptal atrioventricular accessory connection. Twenty five patients (16 women and 9 men, mean age 41 +/- 4 years) with typical AVNRT (cycle length 378 +/- 12 ms) and 29 patients (16 women and 13 men, age 34 +/- 5 years) with an accessory connection (17 manifest and 12 concealed) were studied. The electrophysiology study was performed during sedation with Fentanyl and Midazolam. The mean number of energy applications was 3 +/- 1 for successful slow pathway ablation and 4 +/- 1 for successful ablation of the accessory connection (p:NS). Following the successful energy application, the sinus cycle length decreased significantly 776 ms at baseline to 691 ms in patients with AVNRT. Following successful ablation of the posteroseptal AC, sinus cycle length decreased from 755 ms at baseline to 664 ms (p < 0.05 in both groups [difference between groups not significant]). The decrease in sinus cycle length did not correlate with the number of RF energy applications required for successful ablation or the total energy delivered. In conclusion, ablation of the AV node slow pathway and a posteroseptal accessory connection results in similar increases in the sinus rate. Thus, the increase in sinus rate is probably due to energy application in the posteroseptal space, possibly due to concomitant destruction of vagal inputs, and it is not specific for elimination of slow pathway conduction.

Adult↗