[Experimental validation of calcium phosphate precipitation modeling in a pellet reactor].

Calcium phosphate precipitation is studied in this article. The P-recovery process is carried out in a fluidized sand bed, the so-called pellet reactor which presents major advantages from the hydrodynamical viewpoint. The associated chemistry is yet relatively complex, due to pH gradient along the column and to the residence time of the various precipitates. The experimental observations showed three different phenomena: first, an agglomeration of fines around the sand grains is observed, second, a stagnation of fines in the bed occurs while a significant amount of fines also leaves the bed with the liquid effluent. The purpose of this work is to validate the thermodynamical model developed in our previous works on a semi-industrial sized pilot. Additional experimental runs carried out for various operating conditions showed the robustness of the model. These results open some interesting perspectives for the determination of optimized operating conditions at industrial scale.

Calcium Phosphates↗

Extracting invariable fault features of rotating machines with multi-ICA networks.

This paper proposes novel multi-layer neural networks based on Independent Component Analysis for feature extraction of fault modes. By the use of ICA, invariable features embedded in multi-channel vibration measurements under different operating conditions (rotating speed and/or load) can be captured together. Thus, stable MLP classifiers insensitive to the variation of operation conditions are constructed. The successful results achieved by selected experiments indicate great potential of ICA in health condition monitoring of rotating machines.

Algorithms↗

Solvent gradient operation of simulated moving beds. 2. Langmuir isotherms.

Simulated Moving Bed separations of enantiomers or fine chemicals are usually carried out in the isocratic mode, i.e. by applying the same operating conditions (temperature, pressure, mobile phase composition, pH) in the whole SMB unit. However, it has been recently recognized that by properly modulating operating conditions in the SMB sections. i.e. Sections 1-4 normally, separation performance in terms of productivity and solvent consumption can be significantly improved. In this work, we study solvent gradient SMB (SG-SMB) operation, where the concentration of a modifier in the main solvent constituting the mobile phase is adjusted along the SMB unit, so as to have weaker retention of the species to be separated in the first two sections, and stronger retention in Sections 3 and 4. Overload chromatographic conditions are considered, where the adsorption behavior is characterized by a nonlinear competitive adsorption isotherm, e.g. a binary Langmuir isotherm. Design criteria to achieve complete separation are developed in the frame of the equilibrium theory of chromatography. The theoretical findings are discussed in view of typical effects of the modifier concentration on retention times and solubility of the species to be separated, and an overall assessment of the SG-SMB technology is attempted.

Chromatography↗

Computational flow study of the continuous flow ventricular assist device, prototype number 3 blood pump.

A computational fluid dynamics study of blood flow in the continuous flow ventricular assist device, Prototype No. 3 (CFVAD3), which consists of a 4 blade shrouded impeller fully supported in magnetic bearings, was performed. This study focused on the regions within the pump where return flow occurs to the pump inlet, and where potentially damaging shear stresses and flow stagnation might occur: the impeller blade passages and the narrow gap clearance regions between the impeller-rotor and pump housing. Two separate geometry models define the spacing between the pump housing and the impeller's hub and shroud, and a third geometry model defines the pump's impeller and curved blades. The flow fields in these regions were calculated for various operating conditions of the pump. Pump performance curves were calculated, which compare well with experimentally obtained data. For all pump operating conditions, the flow rates within the gap regions were predicted to be toward the inlet of the pump, thus recirculating a portion of the impeller flow. Two smaller gap clearance regions were numerically examined to reduce the recirculation and to improve pump efficiency. The computational and geometry models will be used in future studies of a smaller pump to determine increased pump efficiency and the risk of hemolysis due to shear stress, and to insure the washing of blood through the clearance regions to prevent thrombosis.

Computer Simulation↗

A simple structured model for continuous production of a hybrid antibiotic by Streptomyces lividans pellets in a fluidized-bed bioreactor.

A simple structured model is developed for the description of the experiments of continuous production of a hybrid antibiotic by Streptomyces lividans TK21 pellets in a fluidized-bed reactor. The model is based on the effect of internal and external phosphate concentrations on antibiotic production during cyclic feeding. These concentrations can be calculated on the basis of the equations postulated by the model. The model also considers the cell growth, reflected in changes of the pellet size along the culture. The model parameters are evaluated sequentially by performing experiments at different operational conditions. The validity of the model and its corresponding parameters is corroborated further by the satisfactory modeling of the bioreactor operation during an extended period of time at various operation conditions.

Anti-Bacterial Agents↗

Removal and transport mechanisms of arsenics in UF and NF membrane processes.

In this study, the removal and transport mechanisms of ionized and non-ionized arsenics through NF and UF membranes were systemically investigated. The charge repulsion between the membrane surface and arsenic ions was an important mechanism for the rejection of ions by a charged membrane. In addition, the effect of J0/k ratio was dependent on the membrane and ion charge, but the cross-flow velocity was not significantly affected. Both diffusion and convection are proved to affect the transport of arsenic ions. The reflection coefficients (sigma) of both UF and NF membranes increased with increasing pH; the reflection coefficients of arsenate were higher than those of arsenite under the same operating conditions. The spiral-wound module exhibited slightly higher arsenate removal than the flat-sheet module under the same operating conditions.

Arsenates↗

A new normalization method for determination of colloidal fouling potential in membrane processes.

Normalization of permeate flux data is widely used to characterize membrane fouling under different experimental conditions. The main intention of normalization is to allow a fair comparison of feed water fouling potentials by eliminating the effects of different operational parameters used in the experiments, such as net driving pressure and clean-membrane resistance. However, it was demonstrated that the commonly used intuitive normalization methods usually could not serve their intended purpose. In this study, a new normalization method was proposed for characterizing water-fouling potential based on fundamental principles of membrane fouling. The intention of this normalization method was to define a fouling potential for feed water that was independent of, or at least, not strongly affected by operational conditions. Laboratory-scale ultrafiltration fouling tests were conducted under different colloid sizes, concentrations, and driving pressures. The experiments showed that the fouling potentials defined by the newly proposed normalization method were linearly related to the colloid concentration of the feed water and that the effect of operational conditions used in the fouling experiments on the fouling potential was minimal.

Journal Article↗

Benzene: a secondary pollutant formed in the three-way catalyst.

Benzene emissions from a relevant proportion of today's gasoline-driven passenger cars and light-duty vehicles can increase by up to 2 orders of magnitude when driving at high engine load (e.g., on highways). Under such conditions, post-catalyst benzene levels exceeded those found pre-catalyst. As a consequence, formation of benzene in the catalyst was postulated. To further reduce ambient air concentrations of benzene,these critical operating conditions must be carefully avoided. Here, we report in detail to what extent and at what operating conditions catalyst-induced benzene and toluene formation can occur. For that purpose, a EURO-1 passenger car (1.8 L, model year 1995)fulfilling the valid regulations, equipped with a new, two-layered, Pd-CeO2-Al2O3/Rh-ZrO2-Al2O3 three-way catalyst was operated at steady state on a chassis dynamometer at 100, 125, and 150 km/h at variable air to fuel ratios. Pre- and post-catalyst exhaust gas concentrations of benzene, toluene, C2-, and C3-benzenes were monitored at a time resolution of 0.5 Hz by means of chemical ionization mass spectrometry. A net benzene formation window, ranging from pre-catalyst exhaust gas temperatures of 600-730 degrees C and lambda-values of 0.83-0.95, with a pronounced minimum at 0.87, was observed. Dealkylation reactions of aromatic hydrocarbons are assumed to be the major pathway leading to benzene.

Air Pollutants↗

[Post-infarction aneurysm of the left ventricle. Pre-operative parameters conditioning the surgical risk and remote results].

83 patients who underwent resection of postinfarction aneurysms involving the anterior wall of the left ventricle were studied to identify possible determinants of operative outcome, long-term survival and long-term improvement. The indications for aneurysmectomy (either isolated or combined with direct revascularization) were congestive heart failure, angina or life-threatening arrhythmias; six patients were asymptomatic at the time of surgery. Operative mortality rate was 14.4% (11.5% for patients operated more than 60 days following myocardial infarction). The over-all survival rate, at a mean follow-up of 31.5 months (range 2 to 82 months), was 74.39%; 80.88% of patient discharged from hospital, exhibited clinical improvement. Mean values of ejection fraction and excess ejection fraction were significantly higher in the group of operative survivors (31.28 +/- 8.26% and 0.17 +/- 0.08 respectively) than those of surgical deaths (20.25 +/- 8.37% and 0.08 +/- 0.06) (p less than 0.005); the coronary score was significantly lower in the group of survivors (6.81 +/- 2.35 vs 8.33 +/- 2.29) (p less than 0.025). Presence of arrhythmias increased operative mortality (33.3% vs 11.2%, p = 0.05), as did a low cardiac output, impaired contraction of the postero-lateral wall and mitral regurgitation. Long-term survival and improvement were not related to anyone of preoperative parameters taken into consideration: however, a higher percentage of clinical improvement was observed when myocardial revascularization was associated to aneurysmectomy (85% vs. 67.7%).

Adult↗

A prospective study on knee proprioception after meniscal allograft transplantation.

The meniscus plays an important role in the proprioceptive ability of the knee joint. The aim of this prospective study was to assess the short-term influence of a meniscus replacement on the proprioception of the knee. Fourteen patients who had undergone a fresh meniscal allograft transplantation between May 2001 and June 2003 were tested pre-operatively and 6 months post-operatively. Disability regarding pain, stiffness and functionality of the affected knee during daily activities was measured by the Western Ontario and McMaster Universities Arthritis (WOMAC) scale. The knee joint position sense was assessed using the Biodex System 3 isokinetic dynamometer. The results of the WOMAC scale showed no significant differences concerning pain, stiffness or knee function between the pre- and post-operative condition of the knee. Assessment of the knee joint position sense at a reference point of 70 degrees of knee flexion revealed a significant improvement of the proprioception of the operated knee at 6 months after surgery compared with the pre-operative condition. The results of this study suggest that although no significant improvement of pain and functionality of the operated knee occurred at this short-term follow-up period, a meniscal allograft transplantation seems to have a significant positive effect on the joint position sense of the previously meniscectomised knee.

Adolescent↗

Thermal effects of the electron beam and implications of surface damage in the analysis of bone tissue.

Electron beam interactions with specimens in the scanning electron microscope (SEM) can lead to increased surface temperatures and damage. These changes may have significant consequences in the analysis of bone tissue. An investigation was performed to measure the surface temperature changes associated with the electron beam on a thermocouple with systematic variations in operating conditions. Probe currents, magnifications, and accelerating voltages were incrementally adjusted to measure the temperature changes and to make assessments for determining optimal operating conditions for the SEM in future analyses of bone tissue. Results from this study suggest that thermal effects were minimal at lower accelerating voltages (< 20 kV), lower probe currents (< 10 nA), and lower magnifications, but surface damage may still occur during the analysis of bone tissue.

Animals↗

Electrodegradation of methylene blue dye in water and wastewater using lead oxide/titanium modified electrode.

A modified electrode was prepared by the electrodeposition of a lead oxide layer on a titanium substrate. This electrode was used as an anode for electrocatalytic oxidation process of dyestuff in aqueous solution. The modified electrode was used for electrochemical degradation of methylene blue dye. The results of the electrocatalytic oxidation process of the dyestuff solutions were expressed in terms of the remaining dye concentration and chemical oxygen demand (COD) values. Different operating conditions and factors that affected the treatment process including current density, pH, initial dye concentration, conductive electrolyte and time of electrolysis were studied. The optimum operating conditions for the dye and modified electrode were investigated. This has resulted in complete removal of the dye and COD. The optimum conditions were applied to the treatment of methylene blue dye in real wastewater solutions. These results indicate that the suggested modified electrode was highly efficient in the treatment of effluents containing methylene blue dye with very slight effect of matrix. This electrochemical system is robust in structure and simple in operation. It has the potential to be developed as a feasible and an effective wastewater treatment process.

Electrodes↗

Interface dynamics in a centrifugal cell separator.

Experiments were performed with bovine blood to study the response of the plasma/cell interface position to pumping rate adjustments in two single-stage (SS I and SS II) cell separation chambers. Standard clinical instrumentation and equipment and on-line computer interfacing were used to monitor and control the interface position. The data provided a quantitative description of its dynamics in the SS I and the SS II chambers. In the SS I chamber, adjustments in the flow rate caused the interface to move very slowly and in a complex manner from one steady-state operation position to another. Such behavior made both manual and computer-controlled operation very difficult. By contrast, the SS II chamber was inherently unstable for most operating conditions. We demonstrated, however, that a feedback controller could be used easily to adjust or maintain the interface position, and this system moved from one steady-state operating condition to another 10 times as fast as the system using the SS I chamber. Also, the manner in which the controller allowed the system to respond to operator requests was much simplier than that for the SS I system.

Animals↗

Nonlinear modeling and adaptive monitoring with fuzzy and multivariate statistical methods in biological wastewater treatment plants.

A new approach to nonlinear modeling and adaptive monitoring using fuzzy principal component regression (FPCR) is proposed and then applied to a real wastewater treatment plant (WWTP) data set. First, principal component analysis (PCA) is used to reduce the dimensionality of data and to remove collinearity. Second, the adaptive credibilistic fuzzy-c-means method is used to appropriately monitor diverse operating conditions based on the PCA score values. Then a new adaptive discrimination monitoring method is proposed to distinguish between a large process change and a simple fault. Third, a FPCR method is proposed, where the Takagi-Sugeno-Kang (TSK) fuzzy model is employed to model the relation between the PCA score values and the target output to avoid the over-fitting problem with original variables. Here, the rule bases, the centers and the widths of TSK fuzzy model are found by heuristic methods. The proposed FPCR method is applied to predict the output variable, the reduction of chemical oxygen demand in the full-scale WWTP. The result shows that it has the ability to model the nonlinear process and multiple operating conditions and is able to identify various operating regions and discriminate between a sustained fault and a simple fault (or abnormalities) occurring within the process data.

Algorithms↗

Intravenous procaine as a supplement to general anesthesia for carbon dioxide laser resection for carbon dioxide laser resection of laryngeal papillomas in children.

Procaine suppresses the cough reflex, decreases laryngeal irritability, and has general anesthetic properties. For these reasons, 14 pediatric patients undergoing CO2 laser resection of laryngeal papillomas were studied in which an intravenous infusion of procaine (1 mg/kg/min) was added to N2O-O2 halothane/enflurane general anesthesia immediately following endotracheal intubation. These patients were compared to nine patients receiving the same anesthesia without procaine. The mean age of both groups was 11 years. There was no difference between the groups in duration of anesthesia or surgery. Emergence, however, averaged 15 minutes in study patients compared to 36 minutes in the control group (p less than 0.01). There was no difference in anesthetic concentrations required to maintain satisfactory operative conditions in the two groups. Muscle relaxants were required intraoperatively in seven control patients but in none of the study patients. The surgeon ranked the operative conditions excellent in all study patients but poor in seven of the nine control patients. Five of the latter required postoperative treatment of laryngeal complications, including reintubation in three. Only one of the study patients had postoperative stridor. No evidence of procaine toxicity was noted in the study patients with total doses ranging from 500--3600 mg. Intravenous procaine is useful in pediatric patients having endoscopic laryngeal operations.

Anesthesia, Inhalation↗

Removal of dye from aqueous solution using a combination of advanced oxidation process and nanofiltration.

In order to have energy and cost effective separation of dyes, a combination of advanced oxidation process (AOP) using Fenton's reagent and nanofiltration (NF) is proposed. Three combinations of AOP and NF are studied using a synthetic solution of eosin dye. Scheme-1 is AOP followed by NF. Scheme-2 is NF followed by AOP. And Scheme-3 is two-step NF. The concentration of eosin dye studied in the first step of each of the schemes is in the range of 70-200mg/l. The operating transmembrane pressures for NF steps are 552, 689 and 828kPa. The crossflow velocities are 0.46, 0.69 and 0.91m/s. The schemes are compared for permeate flux, permeate concentration and duration of operation. In Scheme-1, AOP is conducted for 30min, and then subjected to NF, whereas in Scheme-2, the time needed for AOP is more than 3h to achieve the concentration level of the dye below 1mg/l. Thus, it is found that Scheme-1 is superior to Scheme-2 due to lesser time requirement. However, Scheme-3 involving no AOP, is also suitable for dye separation as the final eosin concentration in the permeate falls below 1mg/l. Scheme-1 is found suitable for dye concentration of 70mg/l and the most appropriate composition of Fenton's reagent is 1665mg/l of H(2)O(2) and 347.5mg/l of FeSO(4)x7H(2)O. Suitable NF operating conditions in step 2 of Scheme-1 is transmembrane pressure of 689kPa and crossflow velocity of 0.91m/s. In Scheme-3, the suitable operating conditions for NF in both the steps are 828kPa transmembrane pressure and 0.91m/s crossflow velocity. Scheme-2 is found to be unsuitable.

Coloring Agents↗

A comparison of topical and retrobulbar anesthesia for trabeculectomy.

PURPOSE: To compare the safety and efficacy of topical versus retrobulbar anesthesia for primary trabeculectomy METHODS: A prospective study of 36 consecutive patients undergoing trabeculectomy who were randomized to receive topical (n = 18) or retrobulbar (n = 18) anesthesia. Operating conditions, patient comfort, and surgical outcome were evaluated. SETTINGS: Tertiary-care university hospital ambulatory surgical center. RESULTS: There were no differences in operating conditions (P = 0.14), pain during (P = 0.54) or after (P = 0.76) surgery, or supplemental anesthesia required (P = 0.34) between the two groups. Very few patients in either group were bothered by touch sensation, tissue manipulation, or the microscope light. Chemosis, subconjunctival hemorrhage and eyelid hemorrhage were seen exclusively in the retrobulbar group (P <0.03), and were all attributable to the injection. Inadvertent eye movement was present more frequently in the topical group (P = 0.01), although this did not pose a problem to the surgeon. No surgical complications were encountered in either group. CONCLUSION: Topical anesthesia is a safe and effective alternative to retrobulbar anesthesia for primary trabeculectomy.

Aged↗

Fractionation of bovine serum albumin and monoclonal antibody alemtuzumab using carrier phase ultrafiltration.

Protein transmission and hence selectivity of separation can be significantly affected by solution pH and ionic strength in protein fractionation using ultrafiltration. Using parameter scanning ultrafiltration, the transmission of bovine serum albumin (BSA) and monoclonal antibody alemtuzumab (Campath-1H) through 300 kDa polyethersulfone (PES) ultrafiltration membranes were studied over a range of pH and salt concentrations, with focus on the likely conditions for achieving "reverse selectivity," i.e., obtaining purified alemtuzumab (approximately 155 kDa) in the permeate. Experimental results demonstrate that the reverse selectivity could be obtained by manipulating the operating conditions such as the solution pH, ionic strength, permeate flux, and system hydrodynamics. With a two-stage batch ultrafiltration process under suitable conditions, the monoclonal antibody alemtuzumab with a purity of > 98% was obtained in the permeate from a feed solution initially containing 0.50 g/l each of BSA and alemtuzumab. Further purity can be expected by selecting more suitable membranes and optimizing operating conditions.

Alemtuzumab↗