PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “FORAMEN”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67Linked to original sources

Right atrial thrombus in an asymptomatic hemodialysis patient with malfunctioning catheter and patent foramen ovale.

The creation of an accurate functioning arteriovenous fistula has been a long-lasting problem in the hemodialysis setting. In spite of recent guidelines and largely because of the old age of the current dialysis population and a high incidence of diabetes mellitus, atherosclerosis, and related vascular problems, it is not always possible to create an adequate fistula. In that case, long-term tunneled indwelling central vein catheters are a frequently used alternative. Of the many possible complications related to venous access in hemodialysis patients, catheter dysfunction is the most prevalent. We report a 23-year-old female hemodialysis patient in whom such malfunctioning was followed by echocardiography that revealed a large right atrial thrombus (RAT) in close contact to the tip of a long-term indwelling catheter in the presence of a patent foramen ovale. Although RAT is a rare complication in hemodialysis patients, it has very specific therapeutic implications. The present patient underwent a successful surgical atrial thrombectomy. Our experience underscores that in cases of malfunctioning catheter, echocardiographic screening is mandatory.

Adult↗

Patent foramen ovale and migraine--bringing closure to the subject.

There is increasing interest in the relationship between migraine and patent foramen ovale (PFO). PFO is more common in migraineurs with aura, and migraine with aura is more prevalent in patients with PFO. Retrospective analyses of PFO closure for stroke prevention and decompression illness in divers have suggested that migraineurs with and without aura may derive significant benefit from PFO closure, but to date no prospective, randomized, sham-controlled study to confirm this has been completed. Herein we review published data regarding the relationship between migraine and PFO and discuss the rationale, justification, and important factors to consider in the conduct of prospective, controlled, clinical trials designed to evaluate the efficacy and safety of percutaneous device closure of PFO for migraine prevention.

Clinical Trials as Topic↗

Incarceration of the small intestine in the epiploic foramen. Report of 19 cases (1983-1992).

The medical records of 19 horses referred for colic and subsequently found (18 confirmed, 1 suspected) to have small intestinal incarceration through the epiploic foramen were reviewed. These horses were of various ages and breeds; they had clinical signs of colic for an average duration of 13.5 hours before examination. Seventeen horses had nasogastric reflux, and 15 had palpable small intestinal distention. Three horses were killed during surgery because of severe intestinal damage. Of the remaining 16 horses, 13 required intestinal resection and anastomosis. The length of incarcerated small intestine varied from 8 cm to 17.6 m. The ileum was involved in 12 cases. In one horse, the mesoduodenum was disrupted before surgery, causing intra-abdominal bleeding; incarceration of bowel was not found during surgery. The short-term (1 month) survival rate was 74% (14 of 19 cases), and the long-term survival rate was 63% (12 of 19 cases). The follow-up period was 3 months to 45 months (mean 17.2 +/- 7.2 months).

Anastomosis, Surgical↗

Protocol for optimal detection and exclusion of a patent foramen ovale using transthoracic echocardiography with agitated saline microbubbles.

Agitated saline bubble studies in conjunction with echocardiography, in particular transesophageal echocardiography, are currently the principal means in the diagnosis of patent foramen ovale (PFO). We describe techniques and guidelines for the detection and exclusion of a PFO. The potential for misinterpretation of these bubble studies exists and therefore, several false positive and false negative scenarios are illustrated and discussed.

Diagnosis, Differential↗

Transesophageal echocardiography through nasal way as a guide to percutaneous closure of patent foramen ovale.

Percutaneous device closure of patent foramen ovale (PFO) has become an effective and safe alternative to medical or surgery treatment. Transesophageal echocardiography (TEE), as commonly used to guide this procedure, has the limitation to require general anesthesia. Recently, intracardiac echocardiography (ICE) with AcuNav probe was used to guide percutaneous PFO closure. We report a 42 year-old man with two previous cryptogenetic strokes in whom both diagnosis and guidance of PFO closure were performed by means of TEE using the AcuNav catheter introduced through nasal way (TEENW). This technique, that does not require general anesthesia, provided adequate and complete view of the Amplatzer procedure. TEENW might offer a feasible and equivalent echocardiographic alternative either to standard TEE or ICE as a guide to percutaneous PFO closure.

Adult↗

Catheter closure of atrial septal defects and patent foramen ovale in patients with an atrial septal aneurysm using different devices.

BACKGROUND: Atrial septal aneurysm is frequently associated with patent foramen ovale (PFO) and atrial septal defects (ASD). Moreover, a relationship between atrial septal aneurysm and embolic cerebrovascular events has been suggested. The aims of this study were to analyze morphological and functional characteristics of atrial septal aneurysm in PFO and ASD patients and to assess the feasibility and efficacy of different devices for transcatheter closure and the influence of atrial septal aneurysm. METHODS: Between March 1997 and May 2000 transcatheter ASD or PFO closure was attempted in 63 patients (mean age 47 +/- 13 years) with an atrial septal aneurysm using one of the following devices: Angelwings (n = 3), Cardioseal (n = 5), Cardioseal-Starflex (n = 7), Amplatzer (n = 11), Amplatzer-PFO (n = 5), PFO-Star (n = 25), or Helex (n = 7). RESULTS: Implantation was primarily successful (after the first or second attempt) in all patients. One PFO-Star device embolized 12 hours after the procedure. During follow-up (0.6-37 months, mean 10.4 +/- 9.2) a residual shunt could be detected by transesophageal echocardiography after 2 weeks in four patients and after 6 months in one patient. Three PFO patients had cerebrovascular events after implantation. Two patients had a transient ischemic attack (TIA) and one patient a stroke. A thrombus formation on the device detected in three patients disappeared after antithrombotic therapy. CONCLUSION: We conclude that ASDs and PFOs with an associated atrial septal aneurysm can be closed with different available devices. There seem to be no additional risks compared with patients without atrial septal aneurysm.

Adult↗

Hypoxemia related to right-to-left shunting through a patent foramen ovale: successful percutaneous treatment with the CardioSeal device.

Hypoxemia related to right-to-left shunting through a patent foramen ovale (PFO) is not rare. It can be observed in correlation with a specific situation such as pneumonectomy and can occur even with normal pulmonary pressure. This article reports the experience of 12 patients in which a transcatheter closure with the CardioSeal device was done successfully. Clinical improvement is often obtained, despite incomplete occlusion of the defects. The author demonstrated that transcatheter closure of PFO can be performed safety and should be considered as an efficient alternative to surgery in cyanotic patients with PFO.

Aged↗

Echocardiographically guided closure of a patent foramen ovale during pregnancy after recurrent strokes.

BACKGROUND: Stroke during pregnancy and puerperium is a severe complication that causes high morbidity and mortality. A patent foramen ovale (PFO) allowing paradoxical embolism is one identified risk factor. CASE: A 25-year-old pregnant woman with PFO suffered from recurrent cerebral embolism. To prevent recurrent cerebral embolism during pregnancy, delivery, and puerperium, interventional closure of the PFO was performed without fluoroscopy under echocardiographic guidance. The postinterventional course was uneventful. CONCLUSION: Percutaneous transvenous closure of a PFO during pregnancy is feasible without the use of fluoroscopy.

Adult↗

Percutaneous closure of patent foramen ovale in symptomatic patients.

BACKGROUND: Patent foramen ovale (PFO) and atrial septal aneurysm (ASA) have been associated with stroke in young adults. Patients with PFO suffering from paradoxical embolism are at increased risk for recurrent events. Percutaneous PFO closure is a new treatment modality aimed at secondary prevention. METHODS AND RESULTS: Since April 1994, 132 consecutive patients, aged 51 +/- 12 years with PFO and with at least one paradoxical embolic event, underwent percutaneous PFO closure using six different device types. The embolic index event was an ischemic stroke in 62% of patients, a transient ischemic attack (TIA) in 33% of patients, and a peripheral embolism in 5% of patients. Thirty-six (27%) patients had PFO associated with ASA, whereas 96 (73%) patients had PFO only. The implantation procedure was successful in 130 (98%) patients. During and up to 6 years of follow-up (mean 1.8 +/- 1.6 years, 231 patient years), a total of eight recurrent embolic events were observed, with six TIAs, two peripheral emboli, and no ischemic stroke. The actuarial freedom from recurrence of the combined end point of TIA, ischemic stroke, and peripheral embolism was 95.3% (95% confidence interval [CI], 91.0%-96.4%) at 1 year and 90.5% (95% CI, 83.6%-97.2%) at 6 years. CONCLUSIONS: Percutaneous PFO closure can be performed with a high success rate. The procedure appears a promising therapeutic modality for secondary prevention of recurrent embolism in patients with PFO. Randomized trials must define its therapeutic value.

Adult↗

Catheter closure of the persistent foramen ovale: mid-term results in 162 patients.

Four different types of occluder systems were used to close a persistent foramen ovale (PFO) in 162 patients with paradoxical embolic events. Ninety-eight patients had ischemic stroke, 60 transient ischemic attacks (TIA) or prolonged reversible ischemic neurological deficit (PRIND), and 4 had peripheral arterial embolism. The age of the patients was 40.2 +/- 11.9 years and the ischemic event had happened 7 +/- 10 months before device closure. CardioSeal and Amplatzer occluders were the most commonly used devices (73 and 77 cases, respectively). Implantations were successful in all patients. Serious catheter-related complications included two device embolizations and two venous bleedings. Six patients had documented supraventricular arrhythmias within the first month after implantation, which disappeared spontaneously within some weeks without therapy in three patients; the other three patients with atrial fibrillation needed conversion to sinus rhythm. Residual leaks were found in 5 out of 116 patients who had been followed by transesophageal echocardiography (TEE) and one leak was closed by a second device. During a follow-up period of 19.4 +/- 16.2 months per patient, TIA and PRIND occurred in 3 of 116 patients. Interventional closure of PFO is a simple, effective and quick method that is superior to surgery and avoids the problems of life-long anticoagulation.

Adult↗

Patent foramen ovale closure in patients with transient ischemia attack/stroke.

Paradoxical embolism through a patent foramen ovale (PFO) has been recognized as a potential cause of transient ischemia attack (TIA) and stroke especially in younger patients. The therapeutic options are medical treatment (antiaggregation or anticoagulation) with an annual recurrence rate of 3% to 4% for stroke or TIA, surgical PFO closure, or catheter closure. Randomized studies are ongoing; however, the results will not be available soon. Since August 1994, we have attempted catheter closure of a PFO in 281 patients (age 17 to 79 years, mean 46.8 +/- 13.2) with paradoxical embolism. Of these, 184 patients had at least one embolic stroke, 112 patients at least one TIA, and 15 patients at least one peripheral embolism. The diameter of the PFO, measured with a balloon catheter, ranged from 3 mm to 24 mm with a mean of 10 +/- 3.5 mm. Implantation of the occluder was technically successful in all patients (two attempts in four patients). Seven different devices were used: 26 Sideris buttoned, 11 ASDOS, 19 Angel Wings, 98 PFO-Star, 37 Cardioseal-Starflex, 57 Amplatzer and, 33 Helex devices. One patient suffered from septicemia and subsequently died. In 2 patients, device embolization occurred during or after the procedure (1 Sideris, 1 PFO-Star; catheter retrieval successful). Thirty-seven patients had other minor complications without long-term sequelae: atrial fibrillation within the first weeks after implantation in five patients, asymptomatic thrombus on the device at routine transesophageal echocardiogram (TEE) in 7 patients (1 Angel Wings, 1 ASDOS, 1 CardioSeal, 4 PFO-Star), and device frame fracture in 25 patients (2 Sideris, 4 ASDOS, 1 Angel Wings, 1 CardioSeal, 17 PFO-Star). No complications occurred with the newer devices (Amplatzer and Helex). A residual shunt after 6 months was found in 5.5% of the patients who had completed their 6-month TEE follow-up. In two patients, a second occluder was implanted because of a residual shunt. During a follow-up period of 1 month to 71 months (mean 12 +/- 16 months, 268 patient years), a recurrence of an embolic event (seven TIA, two stroke) occurred in eight patients. None of these occurred with the newer devices (Amplatzer, Helex). Freedom from recurrence of the combined end point of TIA, ischemic stroke, and peripheral embolism was 95.7% (95% CI: 89.0%-98.4%) at 1 year and 94.1% (95% CI: 80.1-98.4%) at 3 years. Catheter PFO closure is a technically simple procedure. With the newer devices and increasing experience, the success rate has improved and the complication rate has decreased. The advantage of the procedure is that closing the defect means a causal treatment. However, catheter closure of PFO despite a very low morbidity has inherent potential risks like any other interventional procedure. Furthermore, selection of patients who definitely have PFO as the cause of their cerebral event has not been defined. For these reasons, further studies are warranted.

Adolescent↗

Interventional closure with Amplatzer PFO occluder of patent foramen ovale in patients with paradoxical cerebral embolism.

Percutaneous transcatheter closure has been proposed as an alternative to surgical closure or long-term anticoagulation in patients with presumed paradoxical embolism and patent foramen ovale (PFO). We report our mid-term results of 55 consecutive symptomatic patients (mean age: 47 years, range: 20-79) who underwent percutaneous transcatheter closure of PFO after at least one event of cerebral ischemia; 16 (29%) patients had at least one transient ischemic attack and 39 (71%) patients at least one embolic stroke. Multiple embolic events had occurred in 6 (11%) patients. Percutaneous transcatheter closure was technically successful in all 55 patients (100%). For the majority of patients, an Amplatzer PFO occluder measuring 25 mm in diameter (n=49) or an Amplatzer PFO occluder measuring 35 mm in diameter (n=6) was used. Complete occlusion by color Doppler and transesophageal contrast echocardiography investigation was achieved in 96% at follow-up 3-6 months after implantation; only 2 patients had a trivial residual shunt at follow-up. Mean fluoroscopy time was 6.7 minutes (range: 1.7-47.1), and in-hospital follow-up was uneventful except for 1 patient who developed a cardiac tamponade requiring uneventful and successful needle pericardiocentesis. At a mean follow-up of 19 months (range: 3-32) no recurrent embolic neurological events was observed. Transcatheter closure of PFO with Amplatzer PFO occluder devices is a safe and effective therapy for patients with previous paradoxical embolism and aneurysmatic or nonaneurysmatic PFO. Percutaneous closure is associated with a high success rate, low incidence of hospital complications, and freedom of cerebral ischemia events.

Adult↗

Perforation of aortic root as secondary complication after implantation of patent foramen ovale occlusion device in a 31-year-old woman.

Transesophageal echocardiography (TEE) revealed a 3-mm-large patent foramen ovale (PFO). No other reason for these neurological events could be found and the patient underwent percutaneous closure of the PFO with a CARDIA Star 03/30 device without periprocedural complications. Four weeks later, the patient underwent a routine control of device without any adverse clinical symptoms. Surprisingly, echocardiography revealed a perforation of the aortic root by an umbrella strut with a small shunt from the aortic root to the right atrium. Magnetic resonance imaging (MRI) confirmed the diagnosis of device malposition. Consecutively, the patient underwent minimal invasive surgery. After removal of the single perforating strut, the bleeding lesion was closed. The patient remained free of any additional complications during the postoperative course and up until now has had uneventful follow-ups.

Adult↗

Setting up a multidisciplinary program for management of patent foramen ovale-mediated syndromes.

BACKGROUND: These days no codified multidisciplinary protocol has been reported to manage all the different patent foramen ovale (PFO)-mediated syndromes. We sought to propose a multidisciplinary program of diagnosis, treatment, and follow-up of all PFO-mediated syndromes based on an in-hospital multidisciplinary task force and to review the activities during the first year. METHODS: From September 2004, we organized in our hospital, a 600-bed tertiary hospital, a management program for PFO-mediated syndromes based on a task force composed of cardiologists, neurologists, and internists. Different levels of protocols were created in order to cover diagnosis, treatment, and follow-up of PFO-mediated syndromes. We reviewed the activity of our program in the first year up to September 2005. RESULTS: Thirty-five patients (23 female, mean age 65 +/- 24 years) were evaluated for suspected PFO-mediated syndromes: 20 for cryptogenic stroke, 2 for peripheral and coronary embolisms, 3 for platypnea-orthodeoxia, 9 for emicrania with aura, and 1 with hypoxiemia during neurosurgical intervention in the posterior cranial fossa. Diagnosis of PFO was confirmed in 25 patients. According to the multidisciplinary protocols, 15 patients failed to meet the requirements for transcatheter closure and were left in medical therapy whereas 11 patients (7 patients with PFO, 2 with multiperforated ASD, and 2 with a secundum ASD) underwent transcatheter closure. After a mean follow-up of 10.8 +/- 4.9 months, no recurrent PFO syndromes were noted in patients treated with devices. CONCLUSION: The first year of our multidisciplinary program allowed a reasonable and potentially successful approach for correctly identifying patients with PFO-mediated syndromes until randomized studies are completed.

Adult↗

Patent foramen ovale using the Premere device: the results of the CLOSEUP trial.

OBJECTIVES: The CLOSEUP trial was conducted to determine the safety and effectiveness of the Premere closure device in closure of patent foramen ovale (PFO). BACKGROUND: PFO is a relatively common congenital condition, associated with cryptogenic stroke and migraine with aura. The Premere device is specifically designed to close PFO of variable size and length, with right and left anchor arms connected by a flexible tether. The device has an open architecture, a low profile, and a small surface area on the left atrial side which may discourage thrombus formation. METHODS: Patients between 18 and 65 years of age who had a cryptogenic ischemic stroke or a transient ischemic attack and a PFO underwent percutaneous PFO closure using the Premere device. RESULTS: Of the 73 enrolled patients, six patients had atrial anatomy not appropriate for the Premere; 27 patients received the 15 mm and 40 patients received the 20 mm device. Implantation was successful in all patients. At 6 months of follow-up, 86% of patients had no shunt that could be provoked with Valsalva as assessed during contrast echocardiography. Closure rates were better with the 20 mm versus the 15 mm device, and three patients with residual shunt had atrial septal aneurysms at baseline. One patient had transient atrial fibrillation which resolved by 3 months. There were no instances of thrombus, death, or stroke. CONCLUSIONS: These data demonstrate that the Premere device can safely and effectively close PFO. Additional studies should be undertaken to demonstrate the effectiveness of PFO closure in reducing thrombo-embolic events such as stroke.

Adolescent↗

Transcatheter closure of patent foramen ovale in patients with migraine headache.

Our objective is to review the epidemiology and pathophysiology of migraine headache, its association with patent foramen ovale (PFO), and the impact of PFO closure on migraine. Upon reviewing English-language publications listed in MEDLINE relating to migraine headache, PFO, and transcatheter closure of PFO, we selected case series, retrospective and prospective studies relevant to the topic. Primarily retrospective case-control studies demonstrate a link between PFO closure and improvement of migraine headache. Few prospective data confirm the initial results. However, the only randomized, controlled trial finished to date analyzing the effect of PFO closure on migraine failed to reach its primary outcome of resolution of migraine following the intervention. The evidence of a benefit on migraine headache following PFO closure is not convincing, but certainly intriguing. With currently ongoing trials, more information related to this topic can be expected.

Cardiac Catheterization↗

Platypnea-orthodeoxia: an unusual indication for surgical closure of a patent foramen ovale.

Platypnea-orthodeoxia is an infrequently reported clinical form of position dependent dyspnea and oxygen desaturation. There are several diverse etiologies for this syndrome. This case report of a patient with platypnea-orthodeoxia is the first known presentation of a case secondary to a patent foramen ovale and idiopathic hemidiaphragm paralysis. A major problem with this disease is the clinical recognition of its existence. Full recovery is possible with proper assessment of clinical signs and symptoms, appropriate noninvasive diagnostic tests, and corrective surgery in selective cases.

Aged↗

Surgical closure of combined symptomatic patent foramen ovale and atrial septum aneurysm for prevention of recurrent cerebral emboli.

BACKGROUND: Patients with patent foramen ovale (PFO) have an undefined but certainly considerable risk of repeated cerebral ischemia due to paradoxical embolism. Especially, if a cerebrovascular event has already occurred and the combination with an atrial septum aneurysm (ASA) is present this risk increases tremendously. The aim of this study was to demonstrate that surgical closure of PFO in combination with an ASA is safe and useful in preventing recurrent strokes. METHODS: Ten patients with previous cerebral ischemia, proven by CT or MRI, and PFO in combination with an ASA were prospectively scheduled for surgical closure. Patients with extracardiac sources of embolic disease were excluded from this study. However, one patient suffered from a hypercoagulability syndrome. RESULTS: All patients (mean age 35.5 +/- 19.1 years) underwent direct suture of the PFO and plication of the ASA with the aid of cardiopulmonary bypass and cardioplegic arrest (n = 3) or ventricular fibrillation (n = 7). Mean operation time was 123.1 +/- 20.2 minutes; mean bypass time was 34.5 +/- 9.9 minutes. There was no mortality or significant postoperative morbidity. Mean hospital stay was 5.1 +/- 1.5 days. During a follow-up of >4 years, no recurrent stroke or transient ischemic attack occurred and no patient received anticoagulation therapy. CONCLUSION: Our data suggest that surgical closure of PFO in combination with ASA in patients with previous stroke is safe and efficacious to prevent recurrent strokes and avoids lifelong anticoagulation.

Adolescent↗