PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Spectroscopy, Near-Infrared”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67Linked to original sources

Temperature-dependent behavior of bacteriochlorophyll and bacteriopheophytin in the photosynthetic reaction center from Rhodobacter sphaeroides.

We have reexamined the temperature dependence of resonance Raman (RR) spectra of the bacteriochlorin cofactors bound to reaction centers from Rhodobacter sphaeroides. Three types of resonant excitations were performed, namely, Soret band, bacteriopheophytin Qx-band, and near-infrared, Qy-band (pre)resonances. Sample temperature was varied from 300 to 10 K. In both Soret-resonant and Qy-preresonant Raman spectra, the ca. 1610-cm(-1) band corresponding to a bacteriochlorophyll CaCm methine bridge stretching mode is observed to increase in frequency by 4-6 cm(-1) as temperature is decreased from 300 to 15 K. This upshift is interpreted as arising from a change in conformation of the bacteriochlorophyll macrocycles. It may be nonspecific to the protein-bound cofactors, since a similar 4-cm(-1) upshift was observed in the same temperature range for BChl a in solution. Qx-resonant Raman spectra of either of the two bacteriopheophytin (BPhe) cofactors were obtained selectively using excitations at 537 and 546 nm. No significant frequency shift was observed for the CaCm stretching mode of BPheL between 200 and 15 K. We conclude, at variance with a previous report, that the macrocycle of the BPheL primary electron acceptor does not undergo any significant conformational change in the 200-15 K temperature range. Qy-preresonant excitation of RCs at 1064 nm provided selective Raman information on the primary electron donor (P primary). The stretching frequencies of the two conjugated keto and acetyl carbonyl groups of the M-branch primary donor BChl cofactor (P(M)) did not significantly change between 300 and 10 K. In contrast the keto carbonyl stretching frequency of cofactor P(L) was observed to upshift by 5 cm(-1), while its acetyl carbonyl frequency downshifted by 2 cm(-1). The latter shift indicated that the strong H-bond between the acetyl group of P(L) and His L168 may have slightly strengthened at 10 K. Excitation at 1064 nm of chemically oxidized RCs selectively provided RR spectra of the primary donor in its radical P.+ state. These spectra can be interpreted as a decrease of the localization of the positive charge on P(L) from 78% to 63% when the temperature decreased from 300 to 10 K resulting in a more electronically symmetric dimer. Possible origins of the temperature dependence of the positive charge delocalization in P.+ are discussed.

Bacteriochlorophylls↗

FT-IR and near-infrared FT-Raman studies of the secondary structure of insulinotropin in the solid state: alpha-helix to beta-sheet conversion induced by phenol and/or by high shear force.

Insulinotropin (glucagon-like peptide I) is a peptide containing 31 amino acid residues. It stimulates the secretion of the hormone insulin. The solubility of this peptide is highly dependent on its environment and the treatment that it has undergone. For instance, synthetic insulinotropin is highly soluble in neutral phosphate-buffered saline (1 mg/mL). However, the application of shear force by stirring renders it extremely insoluble (1 micrograms/mL). This property may be explained in terms of a change in peptide secondary structure with no alteration in primary structure. In order to understand this phenomenon, FT-IR and near-IR FT-Raman were employed to examine four samples prepared under different experimental conditions. It was found that solubility decreases as the alpha-helix is converted to an antiparallel beta-sheet structure.

Amino Acid Sequence↗

Axial heme ligation in the cytochrome bc1 complexes of mitochondrial and photosynthetic membranes. A near-infrared magnetic circular dichroism and electron paramagnetic resonance study.

The combination of EPR and low-temperature near-IR magnetic circular dichroism spectroscopies have been used to investigate the axial ligation of the cytochromes in the cytochrome bc1 complexes from bovine heart mitochondria, Rhodobacter capsulatus, Rhodobacter sphaeroides, and Rhodospirillum rubrum, and the purified cytochromes c1 from bovine heart mitochondria, Rb. capsulatus and Rb. sphaeroides. The possibility of axial ligation of cytochrome c1 by the amino terminus of the polypeptide was also assessed by acetylating the N-terminus of Rb. capsulatus cytochrome c1 and comparing the properties of the acetylated and unmodified samples. The results are consistent with bis-histidine axial ligation for the high- and low-potential b-type cytochromes and histidine/methionine axial ligation for the c1-type cytochrome in the intact cytochrome bc1 complexes. Purified samples of cytochrome c1 are mixtures of two forms, one with histidine/methionine and the other with bis-histidine axial ligation. The form with bis-histidine axial ligation is also assembled in the M183L mutant of the Rb. capsulatus cyt bc1 complex in which the methionine residue coordinating cyt c1 is replaced by a leucine. The bis-histidine form appears to be an artifact of dissociation of cytochrome c1 from the cytochrome bc1 complex and is greatly enhanced particularly in the bacterial cytochromes c1 by sample handling and the addition of 50% (v/v) ethylene glycol or glycerol.

Amino Acid Sequence↗

Rapid verification of identity and content of drug formulations using mid-infrared spectroscopy.

A general method for the rapid verification of both identity and content of complete solid drug formulations has been devised. Infrared spectra for the samples were recorded using the diffuse reflectance technique, and specially written software was employed to identify the type of formulation and level of active ingredient. This software was devised to ensure reliable use when applied by those with minimal operator skills. Three differing drug tablet formulations containing simvastatin, enalapril maleate and lovastatin, as well as a capsule formulation containing finastride were studied. Adequate precision was obtained to reliably verify drug dosage levels. Near-infrared (NIR) and mid-infrared (MIR) spectrometers were evaluated for use with the method. The MIR instrument allowed sufficient resolution and spectral/structural selectivity to reliably verify correctness of either of two near derivative drugs necessarily present in the same clinical study. Drug tablet and capsule dosage levels tested ranged from 0.2 to 40 mg of drug. Approximately 1% (w/w) of the drug in the formulation was the minimum amount determined. Parameters affecting method ruggedness in routine use were optimized. Experimental addition of an extraneous material to a simvastatin formulation was easily detected and flagged by the routine test procedure. Subsequent data retrieval and searching against spectral libraries was used to demonstrate identification of the additive.

Anticholesteremic Agents↗

Identification of celluloses with Fourier-transform (FT) mid-infrared, FT-Raman and near-infrared spectrometry.

Five different celluloses are studied with FT-IR, FT-Raman and near-infrared (NIR) spectrometry, and the fingerprint region of the spectra is assigned. Identification of each of the five celluloses is possible with each of the three vibrational methods. Four different batches of hydroxyethyl cellulose yield very similar spectra with each of the three vibrational methods. Four different batches of hydroxyethyl cellulose yield very similar spectra with each of the three methods. The methods are compared with respect to their capability to discriminate between celluloses and batches, and with respect to ease and feasibility of sample preparation.

Cellulose↗

Exchange transfusion with fluorocarbon for studying synaptically evoked optical signal in rat cortex.

Optical imaging of intrinsic signal is a powerful technique for studying the functional organization of the brain [T. Bonhoeffer, D. S. Kim, D. Malonek, D. Shoham, A. Grinvald, Optical imaging of the layout of functional domains in area 17 and across the area 17/18 border in cat visual cortex, Eur. J. Neurosci. 7 (1995) 1973-1988; M. Hubener, D. Shoham, A. Grinvald, T. Bonhoeffer, Spatial relationships among three columnar systems in cat area 17, J. Neurosci. 17 (1997) 9270-9284; D. Malonek, A. Grinvald, Interactions between electrical activity and cortical microcirculation revealed by imaging spectroscopy: implications for functional brain mapping, Science 272 (1996) 551-554; A. Shmuel, A. Grinvald, Functional organization for direction of motion and its relationship to orientation maps in cat area 18, J. Neurosci. 16 (1996) 6945-6964] [1] [10] [14] [22]. Three components of intrinsic optical signal can be distinguished. Two of these components can be attributed either to changes in blood volume or to changes in oxygen consumption [R.D. Frostig, E.E. Lieke, D.Y. Ts'o, A. Grinvald, Cortical functional architecture and local coupling between neuronal activity and the microcirculation revealed by in vivo high resolution optical imaging of intrinsic signals, Proc. Natl. Acad. Sci. U. S. A. 87 (1990) 6082-6086] [7]. The origin of the third component is not yet clear but the component seems to be based on scattered light [H.U. Dodt, G. D'Arcangelo, E. Pestel, W. Zieglgansberger, The spread of excitation in neocortical columns visualized with infrared-dark field videomicroscopy, NeuroReport 7 (1996) 1553-1558; K. Holthoff, O.W. Witte, Intrinsic optical signals in rat neocortical slices measured with near-infrared dark-field microscopy reveal changes in extracellular space, J. Neurosci. 16 (1996) 2740-2749; B.A. MacVicar, D. Hochman, Imaging of synaptically evoked intrinsic optical signals in hippocampal slices, J. Neurosci. 11 (1991) 1458-1469; L. Trachsel, H.U. Dodt, W. Zieglgansberger, The intrinsic optical signal evoked by chiasm stimulation in the rat suprachiasmatic nuclei exhibits GABAergic day-night variation, Eur. J. Neurosci. 8 (1996) 319-328] [3] [9] [13] [24]. A spectral fitting method with three components is used for the analysis of intrinsic optical signal [M. Nemoto, Y. Nomura, C. Sato, M. Tamura, K. Houkin, I. Koyanagi, H. Abe, Analysis of optical signals evoked by peripheral nerve stimulation in rat somatosensory cortex: dynamic changes in hemoglobin concentration and oxygenation, J. Cereb. Blood Flow Metab. 19 (1999) 246-259] [17]. In order to validate the analysis, we need the knowledge on contribution of signal resulted from hemoglobin to total intrinsic optical signal. The exchange transfusion with fluorocarbon has the advantage that can change the spectral contribution of hemoglobin [M. Ferrari, M.A. Williams, D.A. Wilson, N.V. Thakor, R.J. Traystman, D.F. Hanley, Cat brain cytochrome-c oxidase redox changes induced by hypoxia after blood-fluorocarbon exchange transfusion, Am. J. Physiol. 269 (1995) H417-H424; A.L. Sylvia, C.A. Piantadosi, O(2) dependence of in vivo brain cytochrome redox responses and energy metabolism in bloodless rats, J. Cereb. Blood Flow Metab. 8 (1988) 163-172] [6] [23]. Here we describe a new method of the reduction of hemoglobin signal from somatosensory evoked optical intrinsic signal in rat cortex by the combination of exchange transfusion with fluorocarbon and imaging system of thinned skull cranial window. The method allows for the study of the synaptically evoked changes in light scattering as well as fluorescence of calcium indicator or voltage-sensitive dye without absorption of hemoglobin.

Animals↗

Near-infrared spectroscopic measurement of glucose in a protein matrix.

A method is described for measuring clinically relevant levels of glucose in a protein matrix by near-infrared (near-IR) absorption spectroscopy. Results from an initial screening of major blood constituents identify protein as a major potential interference to the near-IR measurement of glucose in blood. The interference by protein is caused by relatively high concentrations coupled with strong near-IR absorption bands between 5000 and 4000 cm-1 (2.0-2.5 microns). Calibration models based on a simple univariate calibration procedure are not capable of providing accurate glucose concentrations from an independent set of prediction spectra. By use of the multivariate technique of partial least squares (PLS) regression, glucose concentrations can be determined with a 0.35 mM (6.3 mg/dL) standard error of prediction. The spectral range for this calibration model extends from 4600 to 4200 cm-1, and the optimum number of PLS factors is 14. In addition, calibration models based on a combination of digital Fourier filtering and PLS regression have been constructed and evaluated. Superior calibration models are obtained by using a preprocessing digital filtering step to remove spectral features not associated with glucose. The best overall calibration model was obtained by using a Gaussian-shaped Fourier filter defined by a mean position of 0.03f and standard deviation of 0.007f coupled with a 12-factor PLS regression computed over the spectral range from 4600 to 4200 cm-1. This model provided a standard error of prediction of 0.24 mM (4.3 mg/dL) for an independent set of prediction spectra.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Glucose↗

Near-infrared measurement of relative and absolute humidity through detection of water adsorbed on a silica gel layer.

Near-IR spectroscopy is especially well suited to moisture determination because of the relatively high absorptivity of water compared to most other substances. In the present work, near-IR diffuse-transmittance spectroscopy is applied to the measurement of humidity via observation of adsorbed water on a high-performance thin-layer chromatography silica gel plate. The adsorbed water is detected through both ordinary absorption of radiation by water molecules and the increased scattering of near-IR radiation by the silica gel as it adsorbs more water. This technique shows promise as a highly accurate and sensitive humidity sensor with a time constant of less than 1 min. The addition of inorganic salts to the silica gel layer is shown to increase the response to water vapor. However, it also increases the time constant of the sensor. A miniature humidity sensor using a commercially available near-IR transmissive switch is also demonstrated. Possible interferences and hysteresis effects are investigated.

Adsorption↗

Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides.

Selective calibration models are generated for glucose over the 1-20 nM concentration range by use of partial least-squares regression analysis of near-infrared spectra from 5000 to 4000 cm-1. Two spectral data sets are used to simulate triglyceride and protein variations in clinical samples. Triacetin is used in one data set to simulate variations in triglyceride levels, and bovine serum albumin (BSA) is used in the second data set to simulate variations in blood protein levels. Although these matrix components possess strong absorption bands that overlap and overshadow the absorption bands of glucose, successful calibration models can be generated with no evidence of prediction bias caused by the different levels of the matrix components. Furthermore, the benefits of using digital Fourier filtering as a preprocessing step are evaluated in terms of calibration performance. The resulting calibration models provide standard errors of prediction of 0.5 and 0.2 mM in triacetin and BSA matrices, respectively. Accurate glucose predictions are demonstrated from spectra that correspond to protein concentrations not present in the calibration data set. Lastly, digital Fourier filtering alone is shown to have only limited ability to isolate glucose signals from those of BSA and triacetin due to similarities in the widths of the absorption bands of the three species.

Animals↗

FT-IR and near-infrared FT-Raman study of aggregation of bacteriochlorophyll c in solutions: evidence for involvement of the ester group in the aggregation.

Ultraviolet-visible (UV-Vis) absorption, Fourier-transform infrared (FT-IR), and near-infrared (NIR)-excited FT-Raman spectra have been measured for bacteriochlorophyll c (BChl-c) in acetone, tetrahydrofuran (THF), pyridine-d5, carbon disulfide (CS2), and water-saturated carbon tetrachloride (CCl4) to investigate its aggregation in vitro. The UV-Vis absorption spectra can be classified into two groups. Group I (acetone, THF, and pyridine-d5 solutions) gives a spectrum with a Qy band around 665 nm while group II (CS2 and water-saturated CCl4 solutions) shows a spectrum typical of BChl-c aggregates with a broader red-shifted Qy band. All the NIR-FT-Raman spectra, which are preresonant with the Qy band, are very close to those of chlorophyll a (Chl-a) measured in the corresponding solutions. Bands due to a C = O stretching mode of free and strongly hydrogen-bonded 13(1)-keto carbonyl groups appear near 1685 and 1645 cm-1, respectively. In contrast to the FT-Raman spectra, FT-IR spectra of the pyridine-d5 solution and group II are largely different from those of Chl-a in the corresponding solutions, suggesting that BChl-c forms quite different types of aggregates. It is clear from the IR spectra that the ester carbonyl group plays an important role in the aggregation for the pyridine-d5 and group II solutions. Of particular note is that bands due to C = O stretching modes of the ester group are observed at 1733, 1719, and 1705 cm-1 in the spectrum of BChl-c in water-saturated CCl4.(ABSTRACT TRUNCATED AT 250 WORDS)

Bacteria↗

Electron transfer kinetics in purified reaction centers from the green sulfur bacterium Chlorobium tepidum studied by multiple-flash excitation.

Reaction center preparations from the green sulfur bacterium Chlorobium tepidum, which contain monoheme cytochrome c, were studied by flash-absorption spectroscopy in the near-UV, visible, and near-infrared regions. The decay kinetics of the photooxidized primary donor P840(+), together with the amount of photooxidized cytochrome c, were analyzed along a series of four flashes spaced by 1 ms: 95% of the P840(+) was reduced by cytochrome c with a t(1/2) of approximately 65 micros after the first flash, 80% with a t(1/2) of approximately 100 micros after the second flash, and 23% with a t(1/2) of approximately 100 micros after the third flash; after the fourth flash, almost no cytochrome c oxidation occurred. The observed rates, the establishment of redox equilibrium after each flash, and the total amount of photooxidizable cytochrome c are consistent with the presence of two equivalent cytochrome c molecules per photooxidizable P840. The data are well fitted assuming a standard free energy change DeltaG degrees of -53 meV for electron transfer from one cytochrome c to P840(+), DeltaG degrees being independent of the oxidation state of the other cytochrome c. These observations support a model with two monoheme cytochromes c which are symmetrically arranged around the reaction center core. From the ratio of menaquinone-7 to the bacteriochlorophyll pigment absorbing at 663 nm, it was estimated that our preparations contain 0.6-1.2 menaquinone-7 molecules per reaction center. However, no transient signal due to menaquinone could be observed between 360 and 450 nm in the time window from 10 ns to 4 micros. No recombination reaction between the primary partners P840(+) and A(0)(-) could be detected under normal conditions. Such a recombination was observed (t(1/2) approximately 19 ns) under highly reducing conditions or after accumulation of three electrons on the acceptor side during a series of flashes, showing that the secondary acceptors can stabilize three electrons. From our data, there is no evidence for involvement of menaquinone in charge separation in the reaction center of green sulfur bacteria.

Bacterial Proteins↗

Comparison of spectroscopic techniques for the determination of Kjeldahl and ammoniacal nitrogen content of farmyard manure.

The feasibility of determining the nitrogen content of farmyard manure using infrared spectroscopy was investigated. Fifteen samples each of cattle, pig, and turkey manure were analyzed by three infrared techniques: Fourier transform mid-infrared (MIR), using attenuated total reflection (ATR); near-infrared reflectance (NIR-R); and near-infrared optothermal photoacoustic (NIR-OT). The near-infrared measurements were made at wavelengths determined respectively by four (NIR-OT) and five (NIR-R) band-pass filters. The total nitrogen (using the Kjeldahl method) and volatile (ammoniacal) nitrogen contents of all samples were measured by wet chemistry. Internally cross-validated (ICV) partial least-squares (PLS) regression was then used to obtain calibrations for the nitrogen content. The data sets obtained by each technique were treated separately. Within these sets, data from each manure type were treated both separately and combined: the best predictive ability was obtained by combining data from all three manure types. From the combined data set, the residual standard deviations and correlation coefficients for the ICV-predicted versus actual Kjeldahl nitrogen content were, respectively, 6772 mg/kg dry wt, 0.862 (MIR); 9434 mg/kg dry wt, 0.771 (NIR-OT); and 8943 mg/kg dry wt, 0.865 (NIR-R). For the ammoniacal nitrogen content, the residual standard deviations and correlation coefficients were 3869 mg/kg dry wt, 0.899 (MIR); 6079 mg/kg dry wt, 0.820 (NIR-OT); and 3498 mg/kg dry wt, 0.961 (NIR-R).

Animals↗

Mid-infrared diffuse reflectance spectroscopy for the quantitative analysis of agricultural soils.

Soil samples were analyzed conventionally and by mid-infrared diffuse reflectance spectroscopy for total C, total N, pH, and measures of biological activity. Ground, non KBr diluted, samples (n = 180) from experimental plots (two locations, three replicate plots, under plow and no-till practices, three rates of N fertilizer, and from five depths) were scanned from 4000 to 400 cm(-1) (4-cm(-1) resolution, 64 co-added scans) on a DigiLab FTS-60 Fourier transform spectrometer using a custom-made linear sample transport (50 by 2 mm sample area scanned). Results using partial least-squares regression showed that accurate calibrations can be developed for the determination of a number of compositional parameters: total C, total N, pH, and many measures of biological activity. In general, the results achieved using mid-infrared spectra were at least as accurate as those found previously using near-infrared spectra and were sometimes significantly better, that is, pH.

Agriculture↗

Near-infrared spectroscopic monitoring of the film coating process.

PURPOSE: The purpose of this study was to investigate the potential of near-infrared (near-IR) spectroscopy for non-destructive at-line determination of the amount of polymer coat applied to tablet cores in a Wurster column. METHODS: The effects of coating composition on the near-IR spectroscopic determination of ethylcellulose (Aquacoat ECD-30) or hydroxypropylmethylcellulose (HPMC)-based (Spectrablend) coating were evaluated, as were the performance of several chemometric techniques. RESULTS: Tablets were coated with up to 30% ethylcellulose or 22% HPMC, and samples were pulled at regular intervals during each coating run. Near-IR reflectance spectra of the intact tablets were then collected. The spectra were preprocessed by multiplicative scatter correction (MSC) or second derivative (D2) calculations, and calibrations developed using either principal components (PCs) or multiple spectral wavelengths. The near-IR method provided predictions of film applied with standard errors of 1.07% w/w or less. CONCLUSIONS: Near-IR spectroscopy can be profitably employed in a rapid and non-destructive determination of the amount of polymer film applied to tablets, and offers a simple means to monitor the film coating process.

Calibration↗

Monitoring the melt-extrusion transesterification of ethylene-vinylacetate copolymer by self-modeling curve resolution analysis of on-line near-infrared spectra.

The transesterification of molten ethylene-vinylacetate (EVA) copolymers by octanol with sodium methoxide as catalyst in an extruder has been monitored by on-line near infrared (NIR) spectroscopy. A total of 60 NIR spectra were acquired for 37 min with the last spectrum recorded 31 min after the addition of octanol and catalyst was stopped. The experimental spectra show strong baseline fluctuations which are corrected for by multiplicative scatter correction (MSC). The chemometric methods of the orthogonal projection approach (OPA) and multivariate curve resolution (MCR) were used to resolve the spectra and to derive concentration profiles of the species. The detailed analysis reveals the absence of completely pure variables which leads to small errors in the calculation of pure spectra. The initial estimation of a concentration that is necessary as an input parameter for MCR also presents a non-trivial task. We obtained results that were not ideal but applicable for practical concentration control. They enable a fast monitoring of the process in real-time and resolve the spectra of the EVA copolymer and the ethylene-vinyl alcohol (EVAL) copolymer to be very close to the reference spectra. The chemometric methods used and the decomposed spectra are discussed in detail.

Journal Article↗

Infrared spectroscopy of photodissociated carboxymyoglobin at low temperatures.

We have studied the infrared spectra of the bound and photodissociated states of Mb-12CO and Mb-13CO from 5.2 to 300 K. The absorbance peaks seen between 1800 and 2200 cm-1 correspond to CO stretching vibrations. In the bound state of Mb-12CO, the known lines A0 at 1969, A1 at 1945, and A2 at 1927 cm-1, have center frequencies, widths, and absorbances that are independent of temperature between 5.2 and 160 K. Above 160 K, A2 gradually shifts to 1933 cm-1. The low-temperature photodissociated state (Mb) shows three lines (B0, B1, B2) at 2144, 2131, and 2119 cm-1 for 12CO. The absorbances of the three lines depend on temperature. B0 is tentatively assigned to free CO in the heme pocket and B1 and B2, to CO weakly bound to the heme or heme pocket wall. The data are consistent with a model in which photodissociation of MbCO leads to B1 and B2. B2 decays thermally to B1 above 13 K; rebinding to A occurs from B1. The barriers between B2 and B1 and between B1 and A are described by activation enthalpy spectra. Heme and the central metal atom in state Mb have near-infrared, EPR, and Mössbauer spectra that differ slightly from those of deoxyMb. The observation of essentially free CO in state B implies that the difference between Mb and deoxyMb is not due to an interaction of the flashed-off ligand with the protein but is caused by an incomplete relaxation of the protein structure at low temperatures.

Animals↗

Influence of overlying tissue and probe geometry on the sensitivity of a near-infrared tissue oximeter.

In this paper, the influences of overlying tissue and detecting distance between the source and the detector on the measurement of a tissue oximeter were discussed. The signal-noise-ratio of the detector was also examined. A semi-infinite multi-layer Monte Carlo model was induced to simulate the migration of the photons in the skin, adipose and muscle. The thickness of the adipose layer and the separation between the source and the detector in the muscle were changed to simulate the clinical application. Partial pathlength was introduced as a characteristic parameter to evaluate the sensitivity of the oximeter. A two-wavelength (700 and 830 nm) tissue oximeter was developed to verify the results of the simulation. The Monte Carlo simulation results showed that the sensitivity of the near infrared spectroscopy (NIRS) oximeter declined greatly with increasing overlying tissue thickness. Increasing the distance between the light source and the detector improved the sensitivity. However, in order to achieve a sufficiently high signal-to-noise ratio, it was necessary to limit this distance. The results of a bicycle ergometer exercise verified the above results and showed that, for a special adipose thickness (AT), there may be a reasonable range of the emitter-detector separation.

Adipose Tissue↗

X-ray diffraction studies on chromatophore membrane from photosynthetic bacteria. II. Comparison of diffraction patterns of photosynthetic units from various purple bacteria.

Comparative X-ray diffraction studies, in conjunction with infrared absorption spectroscopy, were performed on chromatophores isolated from various purple photosynthetic bacteria in order to achieve a better understanding of the molecular structure of the photosynthetic unit. Purple non-sulfur bacteria used were Rhodospirillum rubrum, Rhodospirillum molischianum, Rhodopseudomonas sphaeroides, and Rhodopseudomonas palustris. Chromatophores of Chromatium vinosum, as a typical example of purple sulfur bacteria, were also investigated. The results were as follows. Distinct equatorial X-ray diffraction patterns were obtained from chromatophores of all the bacteria examined. They showed diffuse, continuous diffraction patterns having several maxima, and the patterns are evidently distinguished from those of either crystalline or amorphous material. The pattern indicates that the photosynthetic unit in the chromatophore has a highly organized molecular structure in the plane of the membrane. Bacteria whose major photosynthetic pigment is bacteriochlorophyll alpha can be categorized in three groups from the viewpoint of near infrared absorption spectra. X-ray diffraction patterns are also grouped accordingly, although the differences are minimal and the patterns display common features. In other words, the bacteriochlorophyll forms, which are bacteriochlorophyll-protein complexes exhibiting different near-infrared absorption spectra, show different X-ray patterns: the molecular structure of photosynthetic units is closely related to the state of pigment in each complex, although the "X-ray" molecular structure is mainly concerned with the arrangement of constituent protein molecules at the present resolution, whereas the "spectroscopic" structure reflects the local environment of pigment.(ABSTRACT TRUNCATED AT 250 WORDS)

Bacterial Chromatophores↗