Measurements of accelerator-produced leakage neutron and photon transmission through concrete.

Optimum shielding of the radiation from particle accelerators requires knowledge of the attenuation characteristics of the shielding material. The most common material for shielding this radiation is concrete, which can be made using various materials of different densities as aggregates. These different concrete mixes can have very different attenuation characteristics. Information about the attenuation of leakage photons and neutrons in ordinary and heavy concrete is, however, very limited. To increase our knowledge and understanding of the radiation attenuation in concrete of various compositions, we have performed measurements of the transmission of leakage radiation, photons and neutrons, from a Varian Clinac 2100C medical linear accelerator operating at maximum electron energies of 6 and 18 MeV. We have also calculated, using Monte Carlo techniques, the leakage neutron spectra and its transmission through concrete. The results of these measurements and calculations extend the information currently available for designing shielding for medical electron accelerators. Photon transmission characteristics depend more on the manufacturer of the concrete than on the atomic composition. A possible cause for this effect is a non-uniform distribution of the high-density aggregate, typically iron, in the concrete matrix. Errors in estimated transmission of photons can exceed a factor of three, depending on barrier thickness, if attenuation in high-density concrete is simply scaled from that of normal density concrete. We found that neutron transmission through the high-density concretes can be estimated most reasonably and conservatively by using the linear tenth-value layer of normal concrete if specific values of the tenth-value layer of the high-density concrete are not known. The reason for this is that the neutron transmission depends primarily on the hydrogen content of the concrete, which does not significantly depend on concrete density. Errors of factors of two to more than ten, depending on barrier thickness, in the estimated transmission of neutrons through high-density concrete can be made if the attenuation is scaled by density from normal concrete.

Air Pollutants, Radioactive↗

Effect of ethanol on visual-vestibular interactions during vertical linear body acceleration.

BACKGROUND: Ethanol led to disturbed dynamic visual acuity (DVA) during vertical linear acceleration (VLA; amplitude, 5 cm; frequency, 1.2 Hz). The aim of this study was to analyze whether suppression of visual-oculomotor or vestibular pathway is responsible for the disturbance of DVA. METHODS: Twenty volunteers were investigated before and after ethanol consumption (mean breath alcohol concentration, 0.32 mg/liter). Vertical eye movements and linear head acceleration were recorded. Tested stimuli were vestibular (VLA in the dark), visual (smooth pursuit), and combined (VLA plus fixation on an earth-fixed target) stimulation; visual suppression (VLA plus fixation of a head-fixed target); static visual acuity; and DVA. Parameters of analysis were gain, sensitivity, eye velocity and amplitude, latency between onset of head acceleration and start of eye movement, correct and wrong answers during static visual acuity and DVA testing, feeling of drunkenness (FOD), and breath alcohol concentration. RESULTS: Both during isolated visual and during combined visual-vestibular stimulation, alcohol induced a significant latency increase. Furthermore, DVA was disturbed after ethanol consumption. Test subjects with a strong alcohol-induced disturbance of DVA presented during isolated visual stimulation a significantly higher latency change than volunteers with a minor alcohol-induced disturbance of DVA. On the basis of the FOD, two groups were formed (one with a slight and one with a strong FOD). The two groups differed significantly concerning the alcohol-induced latency increase during isolated visual stimulation and the alcohol-induced disturbance of DVA. CONCLUSIONS: Ethanol leads to a disturbance of the visual-oculomotor system and, thus, even during combined visual-vestibular stimulation, to a latency increase. This "delay" is responsible for the disturbance of DVA. This alcohol-induced suppression of the visual-oculomotor system and the disturbance of DVA show a significantly positive correlation with the subjective FOD.

Acceleration↗

Moving towards acceleration for estimates of activity-specific metabolic rate in free-living animals: the case of the cormorant.

1. Time and energy are key currencies in animal ecology, and judicious management of these is a primary focus for natural selection. At present, however, there are only two main methods for estimation of rate of energy expenditure in the field, heart rate and doubly labelled water, both of which have been used with success; but both also have their limitations. 2. The deployment of data loggers that measure acceleration is emerging as a powerful tool for quantifying the behaviour of free-living animals. Given that animal movement requires the use of energy, the accelerometry technique potentially has application in the quantification of rate of energy expenditure during activity. 3. In the present study, we test the hypothesis that acceleration can serve as a proxy for rate of energy expenditure in free-living animals. We measured rate of energy expenditure as rates of O2 consumption (VO2) and CO2 production (VCO2) in great cormorants (Phalacrocorax carbo) at rest and during pedestrian exercise. VO2 and VCO2 were then related to overall dynamic body acceleration (ODBA) measured with an externally attached three-axis accelerometer. 4. Both VO2 and VCO2 were significantly positively associated with ODBA in great cormorants. This suggests that accelerometric measurements of ODBA can be used to estimate VO2 and VCO2 and, with some additional assumptions regarding metabolic substrate use and the energy equivalence of O2 and CO2, that ODBA can be used to estimate the activity specific rate of energy expenditure of free-living cormorants. 5. To verify that the approach identifies expected trends in from situations with variable power requirements, we measured ODBA in free-living imperial cormorants (Phalacrocorax atriceps) during foraging trips. We compared ODBA during return and outward foraging flights, when birds are expected to be laden and not laden with captured fish, respectively. We also examined changes in ODBA during the descent phase of diving, when power requirements are predicted to decrease with depth due to changes in buoyancy associated with compression of plumage and respiratory air. 6. In free-living imperial cormorants, ODBA, and hence estimated VO2, was higher during the return flight of a foraging bout, and decreased with depth during the descent phase of a dive, supporting the use of accelerometry for the determination of activity-specific rate of energy expenditure.

Acceleration↗

Is local myocardial contractility related to endocardial acceleration signals detected by a transvenous pacing lead?

The availability of sensors monitoring cardiac function parameters may offer many interesting new applications in cardiac pacing. A microaccelerometer sensor (BEST, Biomechanical Endocardial Sorin Transducer) located at the tip of a pacing lead (PL) has been developed by Sorin Biomedica. The signal detected by the accelerometer, peak endocardial acceleration (PEA), was shown to reflect cardiac contractility and to be related to the dP/dt signal. Whether the PEA detected by the BEST sensor in different cardiac locations is the expression of local acceleration forces or reflects the whole heart contractility has not yet been demonstrated in humans. Endocardial acceleration and PEA were evaluated in five patients (4 males, 1 female, mean age 68 years) who underwent cardiac catheterization. Sinus rhythm was present in four patients and chronic atrial fibrillation was present in one. The BEST PL was introduced through the left subclavian vein and PEA signals were recorded: (1) at the apex of the right ventricle (RV), (2) within the coronary sinus (CS), (3) at the right atrial appendage (RAA), and (4) floating in the right atrium. The PEA signals were recorded simultaneously with surface ECG, intracardiac electrograms, and RV pressure. At each recording site, PEA signals with significant amplitude were always recorded during the preejection period, during the isovolumic contraction phase, independently of the recording site and cardiac rhythm. The PEA amplitude was higher in the RV (mean value 1.32 g) and it decreased in the RAA and CS (0.75 and 0.45 g, respectively). The same behavior of PEA was observed during sinus rhythm or atrial fibrillation. The amplitude and the timing of the PEA signals detected by the BEST accelerometer were independent of the recording site and atrial rhythm; they appeared to be strictly related to the global ventricular contractility. These results suggest that the BEST could be used either as an effective sensor in closed loop pacing systems, or primarily as a diagnostic hemodynamic sensor.

Acceleration↗

Chronic myeloid leukemia in accelerated phase: treatment results with conventional chemotherapy and allogeneic bone marrow transplantation in 96 patients.

The treatment results of 96 patients with Philadelphia-positive chronic myeloid leukemia (CML) in accelerated phase (AP) were reviewed retrospectively. Treatment of AP consisted of allogeneic bone marrow transplantation in 20 (14 related and 6 unrelated donors) or conventional chemotherapy (CC) in 76 patients. Three main treatment strategies were followed in the CC group: continuation (group A) or dose escalation (group B) of chronic phase therapy or change of chronic phase therapy to hydroxyurea (group C). Median survival was 7.0 months in group A (range 1.8-110), in group B 8.3 months (range 0.9-40) and in group C 9.6 months (range 1.5-47.6), p=0.89. Survival in CC was dependent on response to therapy as the achievement of a second chronic phase was significantly associated (p<0.001) with a longer median survival (21 months) compared with stable accelerated phase disease (11 months) or treatment failure (5 months). Median survival in the BMT group was 16.7 months (range 5-77), the 5-yr probability of relapse was 25% and the 5-yr disease-free survival was 36%. For patients <55 yr median survival after BMT was significantly prolonged compared with median survival after CC (n=45, 8.3 months, p=0.008). After developing criteria of AP, median survival in our analysis has been less than 1 yr. The results of conventional chemotherapy in the treatment of accelerated phase CML are disappointing. If a suitable donor is available allogeneic BMT should be performed without delay in patients with AP.

Adolescent↗

Inflation waves induced by axial acceleration of the aorta.

The phenomenon of high-amplitude inflation waves resulting from a sharp axial acceleration of the aorta, as may occur in road accidents, is investigated theoretically. The aorta is modeled as an axisymmetric tapered membranic shell (tube) made of an incompressible, nonlinear viscoelastic material with cylindrical orthotropy. It is filled with an inviscid, incompressible fluid whose flow is considered as quasi-one dimensional along the tube axis. The equations of motion of the tube and of the fluid are solved numerically, by using a two-step explicit scheme, for several axial acceleration profiles. The solutions shows that an inflation wave is generated and it propagates in opposite direction to that of the acceleration. The wall stresses, deformations and their time derivatives as well as fluid velocity and pressure are determined along the tube at different time intervals. Peak axial and circumferential stresses are high, with the latter far exceeding the former. These stresses may cause rupture of the aorta.

Acceleration↗

Monte Carlo calculation of output factors for circular, rectangular, and square fields of electron accelerators (6-20 MeV).

Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was used to model electron beams (6-20 MeV) from a Varian 2100C linear accelerator. After optimization of the Monte Carlo simulation model, agreement within 1% to 2% was obtained between calculated and measured (with a Si diode) lateral and depth dose distributions or within 1 mm in the penumbral regions. Output factors for square, rectangular, and circular fields were measured using two different plane-parallel ion chambers (Markus and NACP) and compared to MC simulations. The agreement was usually within 1% to 2%. This study was not primarily concerned with minimizing the simulation time required to obtain output factors but some considerations with respect to this are presented. It would be particularly useful if the MC model could also be used to calculate output factors for other, similar linacs. To see if this was possible, the primary electron energies in the MC model were retuned to model a recently commissioned similar linac. Good agreement between calculated and measured output factors was obtained for most field sizes for this second accelerator.

Biophysical Phenomena↗

Practical aspects of in situ 16O (gamma,n) 15O activation using a conventional medical accelerator for the purpose of perfusion imaging.

We report investigations into the feasibility of generating radioactive oxygen (15O, a positron emitter, with half-life 2.05 min) using a tuned Elekta SL25 accelerator, for the end purpose of imaging tumor perfusion. 15O is produced by the "gamma, neutron," (gamma,n) reaction between high-energy photons and normal oxygen (16O) in the body. As most in vivo 16O is bound in water molecules the 15O radio-marker is produced in proportion to water content in tissue. Imaging the washout of the 15O distribution using sensitive positron-emission-tomography (PET) technology can yield spatial information about blood perfusion in the tissue. The aim of this article was to determine the amount of 15O activity that could be produced by the tuned medical accelerator. A further aim was to model the activation process using Monte Carlo and to investigate ways to optimize the amount of 15O that could be generated. Increased activation was achieved by (i) tuning the beam to give higher-energy electrons incident on the target of the accelerator, (ii) increasing dose rate by removing the conventional filtration in the beam and reducing the source to object distance, and (iii) reducing low-energy photons by means of a carbon block absorber. The activity per-unit-dose produced by the tuned beam was measured by irradiating spheres of water to known doses and placing the spheres in a calibrated coincidence-counting apparatus. Peak energy of the tuned bremsstrahlung beam was estimated at 29 MeV, and generated activity up to 0.24/microCi/cc/3Gy in water. The measured amount of 15O agreed to within 10% of the prediction from the Monte-Carlo-computed spectrum, indicating reasonable ability to model the activation process. The optimal thickness of the carbon absorber was found to be about 25 cm. The insertion of a carbon absorber improved spectral quality for activation purposes but at the cost of reduced dose rate. In conclusion, the viability of generating 15O with an Elekta SL25 has been demonstrated. In conjunction with recent advances in high-sensitivity portable PET imaging devices, real potential exists for imaging in situ activated 15O washout as a surrogate measurement of macroscopic tumor perfusion.

Calibration↗

Dose properties of a laser accelerated electron beam and prospects for clinical application.

Laser wakefield acceleration (LWFA) technology has evolved to where it should be evaluated for its potential as a future competitor to existing technology that produces electron and x-ray beams. The purpose of the present work is to investigate the dosimetric properties of an electron beam that should be achievable using existing LWFA technology, and to document the necessary improvements to make radiotherapy application for LWFA viable. This paper first qualitatively reviews the fundamental principles of LWFA and describes a potential design for a 30 cm accelerator chamber containing a gas target. Electron beam energy spectra, upon which our dose calculations are based, were obtained from a uniform energy distribution and from two-dimensional particle-in-cell (2D PIC) simulations. The 2D PIC simulation parameters are consistent with those reported by a previous LWFA experiment. According to the 2D PIC simulations, only approximately 0.3% of the LWFA electrons are emitted with an energy greater than 1 MeV. We studied only the high-energy electrons to determine their potential for clinical electron beams of central energy from 9 to 21 MeV. Each electron beam was broadened and flattened by designing a dual scattering foil system to produce a uniform beam (103%>off-axis ratio>95%) over a 25 x 25 cm2 field. An energy window (deltaE) ranging from 0.5 to 6.5 MeV was selected to study central-axis depth dose, beam flatness, and dose rate. Dose was calculated in water at a 100 cm source-to-surface distance using the EGS/BEAM Monte Carlo algorithm. Calculations showed that the beam flatness was fairly insensitive to deltaE. However, since the falloff of the depth-dose curve (R10-R90) and the dose rate both increase with deltaE, a tradeoff between minimizing (R10-R90) and maximizing dose rate is implied. If deltaE is constrained so that R10-R90 is within 0.5 cm of its value for a monoenergetic beam, the maximum practical dose rate based on 2D PIC is approximately 0.1 Gy min(-1) for a 9 MeV beam and 0.03 Gy min(-1) for a 15 MeV beam. It was concluded that current LWFA technology should allow a table-top terawatt (T3) laser to produce therapeutic electron beams that have acceptable flatness, penetration, and falloff of depth dose; however, the dose rate is still 1%-3% of that which would be acceptable, especially for higher-energy electron beams. Further progress in laser technology, e.g., increasing the pulse repetition rate or number of high energy electrons generated per pulse, is necessary to give dose rates acceptable for electron beams. Future measurements confirming dosimetric calculations are required to substantiate our results. In addition to achieving adequate dose rate, significant engineering developments are needed for this technology to compete with current electron acceleration technology. Also, the functional benefits of LWFA electron beams require further study and evaluation.

Computer Simulation↗

A block design for split-field tests of accelerator alignment.

We present a block design that facilitates split-field tests, a technique frequently employed to assess several potential misalignments in linear accelerators. Two tests are possible with this device using: (1) opposed collimator angles and (2) opposed gantry angles. The first test is sensitive to jaw symmetry only. In the second test, the alignment of one field edge indicates gantry sag, while the other field edge is sensitive to the combined effects of jaw asymmetry, misalignment of the beam spot, and misalignment of the gantry and collimator rotation axes. The block arrangement consists of a pattern of three polygons cast in lead or Cerrobend. The assembly mounts in the accessory tray of the accelerator and allows all necessary exposures to be taken in a single room entry. Any field size up to 24 cm can be tested with the assembly constructed here. A simultaneous test of light field-radiation field coincidence can also be accommodated. Exposed films with a prototype device show that offsets of +/-1 mm are readily visible. The block design facilitates the required measurements for split-field tests and makes this a practical technique for routine quality assurance on a linear accelerator.

Calibration↗

Relative measurements of fast neutron contamination in 18-MV photon beams from two linear accelerators and a betatron.

Fast neutron contamination in photon beams in the 20 MV range have been reported in recent years. In order to determine if the variations were due mainly to differences in measurement procedures, or inherent in the design of the accelerators, three different 18-MV (BJR) photon beams were compared using identical analytical techniques. The units studied were a Philips SL/75-20 and a Siemens Mevatron-20 linear accelerators and a Schimadzu betatron. Gamma spectroscopy of an activated aluminum foil was the method used. By comparing the relative amounts of neutron contamination, errors associated with absolute measurements such as detector efficiency and differences in activation foils were eliminated. Fast neutron contaminations per rad of x rays in a ratio of 6.7:3.7:1 were found for the Philips, Schimadzu and Siemens accelerators, respectively.

Fast Neutrons↗

Off-axis beam quality change in linear accelerator x-ray beams.

The effective energy of the x-ray beam from linear accelerators changes as a function of the position in the beam due to nonuniform filtration by the flattening filter. In this work, the transmittance through a water column was measured in good geometry and the beam quality characterized in units of HVL in water. Measurements were made on a variety of linear accelerators from 4 to 10 MV. The beam energy decreased with increasing distance from the central ray for all accelerators measured.

Particle Accelerators↗

Phosphorus activation neutron dosimetry and its application to an 18-MV radiotherapy accelerator.

Neutron fluxes and dose rates in and near the 18-MV x-ray beam of a Therac-20 accelerator were determined with measured activities from the nuclear reactions 31P(n, rho)31Si (fast neutrons) and 31P(n, gamma)32P (thermal neutrons), published cross sections, and neutron energy spectra from Monte Carlo calculations. Measurements were made in the patient plane in air and at a 10-cm depth in a tissue-similar phantom, and in a plane containing the x-ray target. Orthophosphoric acid solution was identified as a suitable and convenient phosphorus dosimeter material. In the 31P activation method, fluxes and dose rates are determined as the product of measured saturation activity per 31P atom and a conversion factor, which depends on the shape of the assumed neutron spectrum. For fast neutrons, which deliver most of the dose, the accuracy error in the saturation activity determinations was shown to be approximately less than 25%. An inconsistency resulting from neglect of the accelerator's adjustable collimator in the Monte Carlo calculations was demonstrated between the measured saturation activities and the theoretical neutron spectra. The maximum neutron dose equivalent rate observed was 5.9 mSv/Gy of x-ray absorbed dose at the accelerator calibration point. Surface dose equivalent rates of the present study are less than those of fluxmeter and remmeter studies at sites outside Therac-20 treatment fields by as much as factors of 2.4 and 2.8, respectively. The phantom study showed that at 18 MV internally produced neutrons have a negligible effect on the neutron field within the patient.

Neutrons↗

Air activation produced by high-energy medical accelerators.

The activity of 15O and 13N per unit volume of air produced by a 25 and a 45-MeV medical accelerator was determined by direct measurement. The accelerators were operated in such a fashion as to produce maximum activation of the treatment room air. Levels of the order of 1% or less of the maximum permissible concentration in air for 15O and 13N were found immediately after accelerator shutdown. Three different techniques for calibrations of the air detector were investigated.

Air Pollution, Radioactive↗

Dosimetry of a dual photon energy linear accelerator.

We describe the dosimetric characteristics of a newly introduced dual photon energy linear accelerator, the Varian Clinac 1800. Depth doses are compared with other accelerators of the same nominal accelerating potentials (6 and 10 MV). Field flatness at dmax and at 10 cm depth, depth of dmax, wedge characteristics, output factors, and doses in the buildup region are presented.

Particle Accelerators↗

The effect of collimator backscatter radiation on photon output of linear accelerators.

The field-size dependence of the photon output of linear accelerators in air has been attributed in part to changes in the amount of radiation backscattered from the collimator jaws into the dose monitor chamber. This possible effect was investigated for a variety of accelerators with energies from 4 to 15 MV by measuring the monitor unit rate (MU/min) for different collimator openings. This measurement was made without dose rate feedback control, i.e., with constant electron beam current in the accelerator. The monitor unit rate was independent of collimator setting for all machines tested. Hence, it is concluded that backscattered radiation from the collimator jaws into the dose monitor chamber does not contribute to the variation of output with field size.

Particle Accelerators↗

Long term variation in beam symmetry as a function of gantry angle for a computer-controlled linear accelerator.

Testing computer-controlled linear accelerators for patient safety and proper patient dose delivery requires that certain beam characteristics be monitored over an extended period of time. Computer-controlled conformal radiation therapy using asymmetric collimator jaw settings necessitates stable symmetric treatment beams. Long term beam symmetry measurements have been performed on a Philips SL20 dual energy computer-controlled linear accelerator. Symmetry in both the radial and transverse axis of each x-ray beam was monitored for eight gantry positions. These measurements were undertaken to determine the effectiveness of the SL20 beam steering system during dose delivery of 50 monitor units (MU) per field. Evaluation of the data shows that careful beam steering setup procedures result in x-ray beams in which fluctuations in symmetry as a function of gantry angle are within +/- 1.5%. Day to day instabilities produce a total overall variation in beam symmetry on the order of +/- 2.0%. Results suggest the measurement of symmetry as a function of gantry position become a routine quality assurance procedure for this accelerator.

Computers↗

A dose-per-pulse monitor for a dual-mode medical accelerator.

On a radiotherapy accelerator, the dose monitoring system is the last level of protection between the patient and the extremely high dose rate which all accelerators are capable of producing. The risk of losing this level of protection is substantially reduced if two or more dose monitoring systems are used which are mechanically and electrically independent in design. This paper describes the installation of an independent radiation monitor in a dual-mode, computer-controlled accelerator with a moveable monitor chamber. The added device is fixed in the beam path, is capable of monitoring each beam pulse, and is capable of terminating irradiation within the pulse repetition period if any measured pulse is unacceptably high.

Electrons↗