PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Body Fluids”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68Linked to original sources

[Disorders of consciousness due to disorders of body fluid composition--case report of a female patient].

We report a female patient presenting with sepsis and multi-organ failure following eclampsia and intrauterine childdeath. In the phase of recovery, the patient developed consciousness disorder and coma characterized by fasciculation, generalized myoclonia and respiratory insufficiency. The clinical picture corresponded to that of Lance Adam's syndrome. A quick change in the composition of body fluids in the polyuric phase of renal insufficiency associated with an antidiuretic hormone deficit was a cause of that disorder. Metabolic dysfunction and hyperexcitability of neurons developed as a result. Hyperexcitability of the caudal part of the medulla oblongata was responsible for the development of myoclonia. Following the correction of that disorder, the patient completely improved.

Acute Kidney Injury↗

Modification of a tunable UV-visible capillary electrophoresis detector for simultaneous absorbance and fluorescence detection: profiling of body fluids for drugs and endogenous compounds.

Using fused-silica optical fibres for fluorescence light collection and bandpass filters for selection of emission wavelengths, a capillary electrophoresis detection cell of a conventional, tunable UV-Vis absorbance detector was adapted for simultaneous fluorescence (at selected emission wavelength) and absorbance (at selected excitation wavelength) detection. Detector performance is demonstrated with the monitoring of underivatized fluorescent compounds in body fluids by micellar electrokinetic capillary chromatography with direct sample injection. Compared with UV absorption detection, fluorescence detection is shown to provide increased selectivity and for selected compounds also up to tenfold higher sensitivity. Examples studied include screening for urinary indole derivatives (tryptophan, 5-hydroxytryptophan, tyrosine, 3-indoxyl sulfate and 5-hydroxyindole-3-acetic acid) and catecholamine metabolites (homovanillic acid and vanillylmandelic acid) and the monitoring of naproxen in serum, quinidine in serum and urine and of salicylate and its metabolites in serum and urine.

Catecholamines↗

Heterogeneity of corticotropin-immunoreactive compounds in human body fluids.

Using reversed-phase "high-performance" liquid chromatography and hydrophilic ion-pairing reagents, we studied the chromatographic profiles of corticotropin immunoreactivities in human plasma, cerebrospinal fluid, and urine. The chromatographic system we applied provides excellent separation of peptide molecules, with reproducibility (CV) of retention times better than 0.5%, and makes feasible the subsequent immunological quantitation of eluted fractions. Profiles of corticotropin immunoreactivities exhibited several chemically different compounds in each of the three body fluids studied. A considerable portion of these immunoreactive compounds is more hydrophilic and probably of lower molecular mass than the human corticotropin 1-39 molecule itself. These hydrophilic molecules are more predominant in urine and plasma than in cerebrospinal fluid.

Adrenocorticotropic Hormone↗

Multi-component analyses of human body fluids and tissue in health and disease using capillary gas chromatography-mass spectrometry and high-resolution two-dimensional electrophoresis.

Glass capillary gas chromatography-mass spectrometry and high resolution two-dimensional electrophoresis have been used in combination to achieve multi-component analyses of human serum, urine, cerebrospinal fluid and various tumours. The analytical system covers both low- and high-molecular-weight constituents, that is, metabolites and proteins. Over 1000 compounds can be separated in a single sample of a few milligrams. The techniques have been used to study changes in the biochemical composition of body fluids and tissues in different human diseases: metabolic disorder, neurological disorders and certain types of cancer. The new multi-component analytical approach, now in its early stages, may have considerable potential in biomedical research and diagnosis.

Blood Proteins↗

Determination of synapsin I and synaptophysin in body fluids by two-site enzyme-linked immunosorbent assays.

Two-site enzyme-linked immunosorbent assays (ELISA) have been established for the specific and sensitive determination of two membrane proteins of the small synaptic vesicles (SSV), namely: peripheral synapsin I and integral synaptophysin. The ELISA used highly specific capture monoclonal antibodies (mAB) and polyclonal antibodies (pAB) as detectors. For synapsin I, the mAB were newly generated, whereas for synaptophysin, the commercially available mAB SY38 was applied. In order to calibrate the ELISA and to raise pAB, both proteins were purified in the mg-range. Synapsin I was purified by conventional means from human and porcine brain and synaptophysin was purified by immunoaffinity chromatography from porcine brain. Using the ELISA, neither synapsin I nor synaptophysin could be determined in serum or cerebrospinal fluid (CSF) from healthy donors or patients suffering various neurological disorders or pheochromocytomas. For this reason, the degradation of both proteins in serum and CSF was investigated. With the exception of synaptophysin measured in serum, both proteins exhibited fast rates of degradation. Despite the negative results in human body fluids, the two ELISA are appropriate for the quantification of these membrane proteins in neuronal or neuroendocrine cell extracts or preparations of SSV.

Amino Acid Sequence↗

Sensitive analysis of aconitine, hypaconitine, mesaconitine and jesaconitine in human body fluids and Aconitum tubers by LC/ESI-TOF-MS.

The Aconitum species (Ranunculaceae) are widely distributed in northern Asia and North America. Their roots are popularly used in herbal medicines in China and Japan. Many cases of accidental, suicidal and homicidal intoxication with this plant have been reported; some of these were fatal because the toxicity of Aconitum is very high. It is thus important to detect and quantify Aconitum alkaloids in body fluids, with high sensitivity. We have developed a simple and sensitive method for measuring four kinds of Aconitum alkaloids (aconitine, hypaconitine, jesaconitine and mesaconitine) by LC/electrospray (ESI)-time-of-flight (TOF)-MS. For all of them, only molecular ions were observed at an orifice voltage of 75 V; at 135 V, base peaks corresponding to [M - 60 + H]+ ions were observed. These four compounds and methyllycaconitine (internal standard) in human plasma samples were purified by solid-phase extraction. The four extracted compounds were completely separated in mass chromatograms; the calibration curves showed good linearity in the range 10-300 ng/ml, and the detection limits were estimated to be 0.2-0.5 ng/ml. Using our method, we also determined the amounts of these compounds in tuber samples. The present method is applicable in clinical and forensic toxicology.

Aconitine↗

Detection and characterization of the prostate-specific membrane antigen (PSMA) in tissue extracts and body fluids.

The prostate-specific membrane antigen (PSMA) glycoprotein is recognized by the monoclonal antibody (MAb) 7E11-C5.3 as a predominant 100 kDa and minor 180 kDa component in LNCaP cell line extracts and its expression has been shown by immunohistochemistry to be highly restricted to prostate epithelium. The aim of the present study was to utilize Western blot analysis to determine if PSMA could be detected in human tissue extracts and body fluids and if so, which molecular forms were present. PSMA was detected as 120 and 200 kDa bands in normal, benign and malignant prostate tissues and seminal plasma. Further analysis demonstrated that the larger molecular form of PSMA may be a dimer of the lower m.w. species. The PSMA glycoprotein was not detected in the majority of non-prostate tissue extracts examined except for a low yet significant amount in normal salivary gland, brain and small intestine, suggesting that PSMA may not be as prostate-specific as originally thought. Since the prostate-specific antigen (PSA) has been shown to be maximally shed into the serum in high-grade and metastatic prostate carcinomas, it was surprising that PSMA could not be detected in serum by Western blot analysis even in patients with actively progressive metastatic disease. Second generation antibodies generated against different epitopes may be required to determine if PSMA is shed into serum. Our results support the hypothesis that PSMA is a novel prostate biomarker.

Animals↗

Micro high-performance liquid chromatographic system with micro precolumn and dual electrochemical detector for direct injection analysis of catecholamines in body fluids.

A new micro high-performance liquid chromatographic system has been developed, which determines catecholamines from directly injected human urine without any sample pretreatment. The system consists of a mixing junction for adjusting the sample to pH 8.5, a micro alumina precolumn for enriching catecholamines in the sample, and a dual electrochemical detector for selectively detecting catecholamines based on their electrochemical reversibility. The system is able to operate with directly injected body fluids and to determine simultaneously all of the four catecholamines with high precision.

Catecholamines↗

Proportional changes in body fluid with hemodialysis evaluated by dual-energy X-ray absorptiometry and transthoracic bioimpedance with particular emphasis on the thoracic region.

Alterations in body composition during extracorporeal hemodialysis (HD) were investigated in 12 hemodialysis patients (9 males and 3 females, mean age 50 +/- 15 years) with a mean ultrafiltration of 2.6 +/- 1.0 L. Analysis was performed using a dual-energy x-ray absorptiometry technique (DXA), which measures 3 principal components of the body: fat mass (FM): lean body mass (LBM), i.e., all soft tissues excluding fat; and bone mineral content (BMC). These 3 components were calculated for the whole body and for different body regions (namely, the thorax, trunk, lower limbs, and upper limbs). The thoracic cage region could be defined manually, separately from the trunk, and its tissue composition was calculated. DXA analysis was performed concomitant with a measurement of the basal thoracic impedance (TFI) by bioimpedance cardiography prior to and 1 h after dialysis. We found a significant decrease in the total LBM, from 55.8 +/- 8.8 to 53.3 +/- 9.3 kg (p < 0.05), but no change in either the FM or BMC. Moreover, there was a disproportional reduction in the LBM in different regions, being significantly greater in the thorax (7.47 +/- 3.7%) than in the other body regions (trunk 4.3 +/- 2.0%, lower limbs 5.4 +/- 2.1%, and upper limbs 4.7 +/- 1.5%). Regarding bioimpedance, a stronger significant correlation was detected between the percentage changes in the TFI and the changes in thoracic fluid (r = 0.80, p < 0.01) than between the changes in the TFI and the changes in the total body fluid (r = 0.63, p < 0.01). The absolute values of the TFI were also significantly and negatively correlated to the thoracic lean mass to fat mass ratio, both before and after HD (r = 0.82, p < 0.001 and r = 0.86, p < 0.001, respectively). In conclusion, DXA is a very sensitive technique to detect fluid changes during HD in the thorax when the thoracic cavity is defined as a region of interest as well as for the whole body. The data also indicate an extracellular compartmental imbalance between different regions with a significantly greater change in the thoracic region. Transthoracic bioimpedance is a useful technique for evaluating the HD induced changes in the thoracic fluid, rather than total body fluid.

Absorptiometry, Photon↗

A sensitive micromethod for the routine estimation of methylmalonic acid in body fluids and tissues using thin layer chromatography.

A routine method for the rapid estimation of methylmalonic acid (MMA) has been developed using thin-layer chromatography (TLC) on cellulose, locating the separated MMA zones by coupling with a diazo reagent and quantitating the results by densitometric scanning of a photocopy of the chromatogram on transparency film. The method can detect as little as 25 pg MMA in small volumes of urine, plasma and other body fluids or tissue homogenates, has potential for the simultaneous estimation of MMA, other organic acids, methylmalonyl coenzyme A and creatinine and should be of particular value in the investigation of occult cobalamin deficiency or suspected errors of vitamin B12 or intermediary metabolism.

Adolescent↗

Body fluid analysis of a phosphonic acid angiotensin-converting enzyme inhibitor using high-performance liquid chromatography and post-column derivatization with o-phthalaldehyde.

A method is described for the extraction of a phosphonic acid angiotensin-converting enzyme inhibitor from either urine or plasma, and subsequent quantitation using high-performance liquid chromatographic (HPLC) analysis and post-column o-phthalaldehyde reagent derivatization. The compound cannot be quantitatively extracted from the body fluids, but use of a fluorinated internal standard allowed for the computation of accurate results. With the use of an internal standard, excellent precision, linearity, and recovery were obtained for analyte response in both urine and plasma. In urine a working range of 0.2-10 micrograms/ml was found, with a limit of detection of 0.1 micrograms/ml. For plasma the working range was found to be 2-500 ng/ml, and the limit of detection was established as 1 ng/ml. Due to the non-polar character of the analyte at low pH values, it was possible to use novel extraction (solid-phase C8 column) and HPLC [poly(styrenedivinyl benzene) HPLC column] conditions to separate and quantitate the compound from plasma and urine.

Chemical Phenomena↗