PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68Linked to original sources

Linear viscoelastic properties of bovine brain tissue in shear.

We report the results from a series of rheological tests of fresh bovine brain tissue. Using a standard Bohlin VOR shear rheometer, shear relaxation and oscillating strain sweep experiments were performed on disks of brain tissue 30 mm in diameter, with a thickness of 1.5-2 mm. The strain sweep experiment showed that the viscoelastic strain limit is of the order of 0.1% strain. Shear relaxation data do not indicate the presence of a long-term elastic modulus, indicating fluid-like behavior. A relaxation spectrum was calculated by inverting the experimental data and used to predict oscillatory response, which agreed well with measured data.

Animals↗

Effect of pentosanase and oxidases on the characteristics of doughs and the glutenin macropolymer (GMP).

Rheological characteristics of dough and glutenin macropolymer (GMP) extracted thereof were investigated. Three single enzymes, pentosanase (PP), glucoseoxidase (GLZ), and laccase (LAC), and their combinations were used. GLZ gave the least extensible and most resistant dough, and pentosanase/glucoseoxidase (PPGLZ) resulted in dough with improved extensibility. The enzymes improved gluten quality. The glutenin macropolymer (GMP) was characterized in terms of wet weight, protein content, pentosan association, and dynamic rheological properties. Enzymatic addition decreased the wet weight of GMP but increased the protein content. PP decreased the content of pentosans on the GMP, but single oxidases increased the content of pentosans associated with GMP. PP did not modify the elastic modulus (G') of the GMP, whereas GLZ increased G' by increasing the polymerization of proteins and LAC diminished G'. The combination PPGLZ produced a synergic increase of G'.

Bread↗

Stiffness in bending of a superelastic Ni-Ti orthodontic wire as a function of cross-sectional dimension.

Superelasticity is a property used in orthodontics to initiate tooth movement in the first stage of orthodontic treatment. It is the aim of all clinicians to accomplish biological tooth movement, which implies the use of low, continuous force and requires archwire with low stiffness. In this study, 15 nickel-titanium archwires with three different cross-sectional dimensions were tested in three-point bending to determine the nature of forces in a loading and unloading cycle. The evolution of stiffness in bending as a function of wire size is discussed. The applied forces or stiffness dependence on cross-sectional size differs from the linear-elastic prediction because of the superelasticity property. We discuss the origin of the nonconventional profile of curves and the nature of reversible large deformation of these alloys. Martensitic transformation is at the origin of nonlinear elasticity. The stiffness decreases with increasing deflection, and this phenomenon is emphasized in the unloading process. The value of stiffness appears to vary with wire size but depends on the ratio of volume of martensitic transformation. During martensitic transformation, the rigidity (elastic modulus) of the alloy is nonconstant. These results and their understanding should allow a different approach of biomechanical considerations, ie, a large-size square wire does not produce necessarily high forces.

Biomechanical Phenomena↗

Disc lesions and the mechanics of the intervertebral joint complex.

STUDY DESIGN: Correlations between tears in the disc and the mechanics of both the intervertebral joint and vertebral body bone were analyzed. OBJECTIVES: To examine the effect of disc degeneration on the mechanics of spinal motion segments. SUMMARY OF BACKGROUND DATA: Degeneration of the intervertebral disc results in changes to the mechanics of the spine. The actual effect of tear type and size on the mechanics of the intervertebral joint is unknown. METHODS: Thirty spinal specimens (median age, 68 years) were divided into T12-L1, L2-L3, and L4-L5 motion segments. Mechanical tests recorded stiffness in flexion, extension, and torsion. Disc morphology was ascertained by taking three transverse sections of the disc and mapping and measuring the concentric tears, radial tears, and rim lesions. The severity of each tear type within each disc then was quantified. Bone cubes from the adjacent vertebral bodies were tested in compression to determine the elastic moduli and tested to failure in the longitudinal direction. RESULTS: Groups with tears were older and had reduced bone elastic moduli than groups without tears. Extension stiffness for the intact joint tended to increase with increasing tear severity. A decrease in torsional stiffness was present with increased severity of rim lesions at both L2-L3 and L4-L5. CONCLUSIONS: Tears in the intervertebral disc are reflected in a reduction in vertebral bone elastic modulus and in changes in the mechanics of the intervertebral joints in flexion, extension, and torsion.

Aged↗

Chronic platelet-activating factor induces a decrease in pulmonary vascular compliance, hydroxyproline, and loss of vascular matrix.

We have previously demonstrated that chronic intravenous platelet-activating factor (PAF) induces morphologic remodeling of pulmonary arteries characterized by a decrease in internal and external elastic lamina circumference, pulmonary arterial contracture, and internal elastic lamina duplication. The mechanism of PAF-induced arterial contracture is unknown. In this study we determined whether PAF caused arterial contracture through cell loss by calculating the number of cell nuclei/total cross-sectional area of arteries. The nuclear ratio was increased in intra- and preacinar pulmonary arteries of PAF-treated rabbits. Hydroxyproline content of lungs stratified by anatomic region was significantly reduced in intra-acinar tissue of PAF-treated rabbits, indicating that PAF-induced vascular contracture was associated with loss of interstitial collagen. We next tested whether these morphologic alterations were associated with decreased pulmonary vascular compliance and increased resistance. Compliance and resistance were determined in isolated, perfused lungs from rabbits chronically treated with PAF. Compliance was calculated: (1) from the slope of the venous occlusion trace (CVO), (2) by increasing left atrial pressure (CLA), (3) by increasing flow (CHF), and (4) by the classic static technique (CAV) of adding volume (2 ml) to a passively drained lung. Vascular compliance was significantly reduced in PAF-treated lungs when measured by all four methods; however, pulmonary vascular resistance was unchanged. We conclude that structural changes that result from chronic intravenous PAF infusion affect the elastic modulus to a greater extent than factors that influence pulmonary vascular resistance.

Animals↗

Mechanical characteristics of the canine thoracic duct: what are the driving forces of the lymph flow?

This study is designed to better understand the mode of lymph transport, particularly through the extrinsic pumping by external compression of the lymph vessel. The pressure-diameter relationship of lymphatic segments isolated from the canine thoracic duct was examined using a laser optical micrometer measurement system. Results revealed that the thoracic duct displayed a high extensibility or compliance in the physiological pressure range, yet became progressively less so with increasing internal pressure. The calculated incremental circumferential modulus of the thoracic duct under physiological pressure (range of 2 to 6 cm H2O) showed values ranging from 1.2 x 10(4) to 3.61 x 10(5) dyn/cm2. At a pressure of 35 cm H2O, the modulus reached a limiting value of approximately 6.0 x 10(6) dyn/cm2. In the physiological pressure range, the relative wall thickness (h/R0) of the canine thoracic duct was approximately 3.5%, which was much lower than that reported for canine arterial segments and similar in value to that of the canine jugular vein. In conclusion, the pressure-diameter curve of the canine thoracic duct was shown to resemble that of venous vessels. However, the circumferential elastic modulus of the thoracic duct wall was lower than the moduli of veins, proving that lymphatics are more compliant than veins. This suggests lymph flow in the thoracic duct may be better promoted by external compression of the lymphatic vessel.

Animals↗

Relations of mechanical properties to density and CT numbers in human bone.

Mechanical properties of cortical and cancellous bone from eight human subjects were determined using an ultrasonic transmission technique. Raw computerized tomography (CT) values obtained from scans of the bones in water were corrected to Hounsfield units. The correlations between CT numbers and mechanical property estimated from cortical bone were found to be low (r2 < 0.2), while these relationships for cancellous bone were found to be higher (r2 > 0.6). These results suggest that CT values may be useful in predicting mechanical properties only for cancellous bone. Poor correlations were found between modulus in the radial or circumferential direction and modulus in the superior-inferior direction for cortical bone, whereas good correlations were found between modulus in the anterior-posterior direction or medial-lateral direction and modulus in the S-I direction for cancellous bone. These results indicate that modulus in the radial or circumferential direction could not be predicted from modulus in the S-I direction for cortical bone, but could be predicted for cancellous bone. The predictive capabilities of linear and power models evaluated for cancellous bone alone were approximately equal. However, the power function gives a better fit of data at the low and high density values. The specific relationships, depending on the types of bone, that predict elastic modulus from density and CT numbers were suggested for human cortical and cancellous bone. These specific correlations may help a number of researchers develop more accurate models; however, these hypotheses should be proven by further study.

Aged↗

Quo vadis elasticity imaging?

In the past decade, an important field that has emerged as complementary to ultrasonic imaging is that of elasticity imaging. The term encompasses a variety of techniques that can depict a mechanical response or property of tissues. In ultrasound, its premise is built on two important facts: (a) that significant differences between mechanical properties of several tissue components exist and (b) that the information contained in the coherent scattering, or speckle, is sufficient to depict these differences following an external or internal mechanical stimulus. Parameters, such as velocity of vibration, displacement, strain, strain rate, velocity of wave propagation and elastic modulus, have all been demonstrated feasible in their estimation and have resulted in the accurate depiction of stiffer tissue masses, such as tumors, high-intensity focused ultrasound (HIFU) lesions and atherosclerotic plaques. More recently, through the development of ultrafast algorithms tailored to suitable hardware as well as the familiarity of the physician with the sensitivity of the methods used, one elasticity imaging technique in particular, elastography, has been shown applicable in a typical clinical ultrasound setting. In other words, elastograms can currently be obtained at quasi real-time (approximately at a frame rate of 8 frames/s) and with the use of a hand-held transducer (as opposed to the previously used frame-suspended setup) during and simultaneously with an ultrasound exam of, e.g., the breast or the prostate. The higher frame rate available with certain clinical ultrasound scanners has also resulted in the successful application of elasticity imaging techniques on the myocardium and monitoring its deformation over several cardiac cycles for the detection of ischemic regions. As a result, elasticity imaging with its ever increasing number of applications and demonstrated applicability in a typical, clinical ultrasound setting promises to make an important contribution to the ultrasound practice as we know it.

Elasticity↗

The influence of water on the nanomechanical behavior of the plant biopolyester cutin as studied by AFM and solid-state NMR.

Atomic force microscopy and solid-state nuclear magnetic resonance have been used to investigate the effect of water absorption on the nanoscale elastic properties of the biopolyester, cutin, isolated from tomato fruit cuticle. Changes in the humidity and temperature at which fruits are grown or stored can affect the plant surface (cuticle) and modify its susceptibility to pathogenic attack by altering the cuticle's rheological properties. In this work, atomic force microscopy measurements of the surface mechanical properties of isolated plant cutin have been made as a first step to probing the impact of water uptake from the environment on surface flexibility. A dramatic decrease in surface elastic modulus (from approximately 32 to approximately 6 MPa) accompanies increases in water content as small as 2 wt %. Complementary solid-state nuclear magnetic resonance measurements reveal enhanced local mobility of the acyl chain segments with increasing water content, even at molecular sites remote from the covalent cross-links that are likely to play a crucial role in cutin's elastic properties.

Biomechanical Phenomena↗

Forces generated during actin-based propulsion: a direct measurement by micromanipulation.

Dynamic actin networks generate forces for numerous types of movements such as lamellipodia protrusion or the motion of endocytic vesicles. The actin-based propulsive movement of Listeria monocytogenes or of functionalized microspheres have been extensively used as model systems to identify the biochemical components that are necessary for actin-based motility. However, quantitative force measurements are required to elucidate the mechanism of force generation, which is still under debate. To directly probe the forces generated in the process of actin-based propulsion, we developed a micromanipulation experiment. A comet growing from a coated polystyrene bead is held by a micropipette while the bead is attached to a force probe, by using a specially designed "flexible handle." This system allows us to apply both pulling and pushing external forces up to a few nanonewtons. By pulling the actin tail away from the bead at high speed, we estimate the elastic modulus of the gel and measure the force necessary to detach the tail from the bead. By applying a constant force in the range of -1.7 to 4.3 nN, the force-velocity relation is established. We find that the relation is linear for pulling forces and decays more weakly for pushing forces. This behavior is explained by using a dimensional elastic analysis.

Actins↗

Intrinsic aging and effective viscosity in the slow dynamics of a soft glass with tunable elasticity.

We investigate by rheology and light scattering the influence of the elastic modulus, G0, on the slow dynamics and the aging of a soft glass. We show that the slow dynamics and the aging can be entirely described by the evolution of an effective viscosity, eta(eff), defined as the characteristic time measured in a stress relaxation experiment times G0. At all times, eta(eff) is found to be independent of G0, of elastic perturbations, and of the rate at which the sample is quenched in the glassy phase. We propose a simple model that links eta(eff) to the internal stress built up at the fluid-to-solid transition.

Journal Article↗

Elemental composition, morphology and mechanical properties of calcified deposits obtained from abdominal aortic aneurysms.

Calcified deposits exist in almost all abdominal aortic aneurysms (AAAs). The significant difference in stiffness between these hard deposits and the compliant arterial wall may result in local stress concentrations and increase the risk of aneurysm rupture. Calcium deposits may also complicate AAA repair by hindering the attachment of a graft or stent-graft to the arterial wall or cause vessel wall injury at the site of balloon dilation or vascular clamp placement. Knowledge of the composition and properties of calcified deposits helps in understanding the risks associated with their presence. This work presents results of elemental composition, microscopic morphology, and mechanical property measurements of human calcified deposits obtained from within AAAs. The elemental analyses indicate the deposits are composed primarily of calcium phosphate with other assorted constituents. Microscopy investigations show a variety of microstructures within the deposits. The mechanical property measurements indicate an average elastic modulus in the range of cortical bone and an average hardness similar to nickel and iron.

Aged↗

Water sorption and mechanical behaviour of cosmetic direct restorative materials in artificial saliva.

OBJECTIVES: To evaluate the water sorption and mechanical behaviour of a compomer in comparison with those of its nominal forerunners, a filled resin restorative material and a conventional glass ionomer cement. METHOD: Compomer (Dyract AP) (D-AP), filled resin (SureFil) (SF), and glass ionomer (ChemFlex) (CF) (all Dentsply, Addlestone, UK) restorative materials were tested. Forty bar specimens (26x1.5x1.0mm(3)) of each material were prepared according to the manufacturer's instructions and randomly distributed into eight groups: dry air (22% RH), saturated water vapour (WV) (100% RH), and five in artificial saliva (AS) at pH6, all at 37 degrees C, as well as untreated control (UC) (23 degrees C, 50% RH). Water sorption was assessed gravimetrically; flexural strength and elastic modulus were determined in three-point bend. The control group was tested at 24h; AS groups were separately tested after 0.5, 1, 3, 6 and 9 months; the other two at 9 months. RESULTS: Mass gain for SF, D-AP and CF in AS was up to 0.17%, 1.2% and 7.0%, respectively. CF showed a marked decrease of strength in AS compared with other groups, followed by a gradual slight rise to a peak at 3 months. Unlike SF and CF, whose flexural strength remained relatively stable, that of D-AP showed a sharp decline from the 1 month peak (P=6x10(-7)) after 6 months in AS. D-AP also showed a slight decline in flexural modulus from a peak, that of SF was quite stable, while CF showed no peak. The values of flexural strength for both CF and D-AP at 9 months were significantly lower in AS than WV, but SF showed no such difference. SIGNIFICANCE: Materials intended for service in the mouth must be stored in a realistic medium if the results of testing are to be interpretable. Dyract AP, a compomer, does not seem suitable for application in stress bearing areas as is currently recommended by its manufacturer. The rapid decline in flexural strength after 1 month of exposure to AS and its progressive fall in flexural modulus suggest a progressive deterioration of the material and this necessitates re-examination of the chemistry of compomers, if the behaviour is typical of the class.

Air↗

Influence of elastic deformation of particles on Heckel analysis.

The Heckel equation is one of the most useful equations for describing the compaction properties of pharmaceutical powders. Important material properties (e.g., yield strength) of powders can be derived using Heckel analysis. Two types of Heckel analysis are in common use. One is the "out-of-die," or "zero-pressure" method, the other is the "in-die" or "at-pressure" method. Because particles undergo elastic deformation under pressure, which tends to lower the porosity of the powder bed, the "out-of-die" method describes powder consolidation and compaction more accurately than the "in-die" method. However, "in-die" Heckel analysis has been widely used because of the speed and ease of data collection. Using L-lysine monohydrochloride dihydrate as a model compound, this work analyzes quantitatively the effects of elastic deformation on the calculation of porosity of a tablet, and therefore on the Heckel analysis. The effects of a small change in porosity, epsilon, on Heckel analysis are presented mathematically. It is found that a decrease in porosity of 0.001, when the porosity is lower than 0.05, causes a significant increase in the value of -ln epsilon. Therefore, data at epsilon < 0.05 should be interpreted with caution when using Heckel analysis. Elastic deformation causes positive deviations in the Heckel plot, and therefore leads to a yield strength that is lower than the true value. The lower the elastic modulus of the powder, the greater is the deviation from the true value. Therefore, the "in-die" method gives values of yield strength that are significantly lower than the true values for most pharmaceutical powders.

Elasticity↗

Biomechanical evaluation of retrieved massive allografts: preliminary results.

Allograft bone is the primary source of graft material for large skeletal defects. No study has determined the physical characteristics of such grafts after various periods of time in vivo for incorporation and remodeling. The purpose of this pilot study was to obtain allograft tissue and biomechanically evaluate the tissue to assess allograft bone material properties. The mechanical properties of the retrieved allograft tissue were compared to allograft bone prior to transplantation. Histological analysis of the retrieved allograft tissue is currently underway to correlate degree of incorporation, allograft porosity, and microfracture density with allograft material properties. After allograft retrieval, radiographs were used to plan sectioning for histological and biomechanical analyses. Rectangular sections of uniform dimensions (50 x 3 x 3 mm) were mapped and machined from the bulk specimens. The samples were loaded in bending in the medial to lateral direction using a 4-point bending fixture to obtain flexural elastic modulus and breaking strength. Preconditioning was applied to each specimen by cycling through 5 submaximal loading cycles (maximum deflection = 1% specimen length). After preconditioning, the specimens were loaded to failure at a rate of 1 mm/min. Retrieved specimens consisted of 1 tibia, 2 femurs, and 2 humeri ranging from 2 to 13 years in vivo. Two control tibia specimens were also tested. Assuming that material properties of cortical bone are consistent regardless of skeletal site, the preliminary data indicates that allograft modulus and strength decline with time in vivo. Testing and analysis of more specimens continue in order to corroborate these initial results.

Biomechanical Phenomena↗

Effect of complement on the viscoelastic properties of human erythrocyte membrane.

Using the micropipette technique, we examined the viscoelastic properties of the red blood cell (RBC) membrane which had been strongly coated with various components of complement (primary C3b, C3d, C4b, C4d) in vitro. The membrane elastic modulus (E), the viscosity index of the initial rapid phase of deformation (eta D1), the viscosity of the later slow phase of deformation (eta D2) and the viscosity of the recovery phase (eta R) were determined. Compared to control non-complement coated RBCs, RBCs coated with C3d, either alone or with other complement components, showed significant increase in the values for elasticity and viscosities. Thus C3d fixation resulted in decreased membrane deformability. Changes in membrane viscoelasticity due to bound C3d were not enhanced by bound C4b, C4d, C5, factor Bb or p; presence on RBC membrane of the latter two complement components may partially reverse the effect of C3d fixation. Lipid fluidity of RBC membrane, examined by fluorescence depolarization, increased with fixation of all complement components except C5. These complement-induced changes in membrane viscoelastic properties have potential pathophysiological and clinical implications. The data suggest that extravascular sequestration of human RBCs may be explained in part by increased membrane rigidity resulting from C3d fixation.

Complement C3↗

Biological impact of polyacetal particles on loosening of isoelastic stems.

The aim of our study was to identify biological factors responsible for premature loosening of polyacetal hip stems. The results of histological analyses of the tissue around 11 total hip prostheses with loosened polyacetal femoral stems were compared to those obtained in a group of 11 total hip prostheses with loosened metal (CoCr) femoral components. A higher number of polymer wear particles surrounded by giant cells, more bone chips, and a more extensive necrosis were found around loosened polyacetal stems. Histomorphological characteristics of polyacetal wear particles containing BaSO(4) granules in the tissue around loosened polyacetal stems were described. Radiological evaluation of the wear of polyethylene cups suggested that elastic modulus of the stem had no influence on the wear of polyethylene cups. This study indicates that polyacetal wear particles have a great biological potential accelerating the process of loosening.

Acetals↗

Dentin caries activity status related to hardness and elasticity.

This research tested the hypothesis that active and arrested carious dentin lesions have distinct structural characteristics and differ in atomic force microscopy-based nano-mechanical properties of the identifiable zones found in hydrated coronal carious lesions. Eight carious molars were used in this study. After longitudinally bisecting all the samples through the centers of carious lesions, they were divided into two subgroups: moderately active caries and arrested caries. The samples were highly polished and stained by caries detector, which allowed identification of four zones: pink, light pink, transparent and apparently normal. The mechanical properties were studied wet using atomic force microscopy. The results show that both groups contained the same zones, regardless of activity status, and different zones have different mechanical properties. Generally, the more demineralized outer zones (pink, light pink) were larger and the mechanical properties of the zones were lower for moderately active caries. For arrested caries, the transparent zone occupied a larger portion of the lesion and the reduced elastic modulus was not significantly different from the underlying normal zone, although its hardness was lower than the apparently normal zone.

Dental Caries↗