PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Analog-Digital Conversion”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

Computerized system for assessing heart rate variability.

The principal theoretical, methodological and clinical aspects of heart rate variability (HRV) analysis are reviewed. This method has been developed over the last 10 years as a useful noninvasive method of measuring the activity of the autonomic nervous system. The main components and the functioning of the computerized rhythm-analyzer system developed by our team are presented. The system is able to perform short-term (maximum 20 minutes) time domain HRV analysis and statistical analysis of the ventricular rate in any rhythm, particularly in atrial fibrillation. The performances of our system are demonstrated by using the graphics (RR histograms, delta RR histograms, RR scattergrams) and the statistical parameters resulted from the processing of three ECG recordings. These recordings are obtained from a normal subject, from a patient with advanced heart failure, and from a patient with atrial fibrillation.

Algorithms↗

Direct spinal curvature digitization in scoliosis screening--a comparative study with Moiré contourgraphy.

The forward bending test, widely used in scoliosis screening, is associated with high false-positive rates. We postulate that direct surface measurement of the spinal curvature by digitization of the spinous processes used in combination with the forward bending test could increase the predictive value of detecting scoliosis without sacrificing sensitivity. Sixty consecutive patients referred from a school screening program were included in this study. All had moiré contourgraphy, spinous process digitization, and erect frontal radiographs of the spine. The number of false positives from the forward bending test was 35. Moiré contourgraphy did not reduce the number of false positives significantly. A posterior spinal deformity of 10 degrees or more predicted scoliosis in all patients, with 15 false-positive readings. Direct measurement of the spinal curvature by spinous process digitization can be an effective second-stage screening tool for scoliosis in centers where all the screened positives are referred to a single center.

Adolescent↗

[The "polarization" hunger dominant (the behavioral characteristics and EEG spectral analysis)].

A new experimental model of dominant was developed by the author, the so-called "polarization" hunger dominant created by application of weak direct current to the lateral hypothalamus in combination with a sound stimulus. There was an increase in the delta component of the electrical activity of the left parietal cortex (the dominant focus) while the EEG spectral power of the other cortical areas, lateral and ventrolateral hypothalamus decreased in the slow-wave ranges.

Acoustic Stimulation↗

Analog vs. digital photogrammetry for optic cup analysis.

This report compares the reproducibility of analog and digital photogrammetry for topographical analysis of the optic cup. Ten simultaneous stereophotographs of each of three optic discs were taken with the Zeiss fundus camera plus a twin-prism stereoseparator. Digital processing produced photogrammetric contours of the optic cup and estimates of its geometry. Optic cup contours from the same stereopairs were also drawn with an analog stereoplotter and were analyzed by manual planimetry. The reproducibility of digital photogrammetry and analysis for estimation of cup depth, cup width, cup cross sectional area, and cup volume was concluded to be generally superior to the reproducibility of analog photogrammetry and manual analysis.

Analog-Digital Conversion↗

A PC-based workstation for real-time acquisition, processing, and display of electromyogram signals.

A system for real-time acquisition, processing, display, and logging of multiple channels of the EMG waveform has been described. By designing this system around the configuration of a standard PC, custom hardware was avoided. Similarly, software was designed in a higher-level language (C), simplifying the programming burden and minimizing custom software development. Components of the software are available off the shelf. The computational capacity of generic PCs facilitates very high rates of numeric calculation, as required by some advanced EMG amplitude estimation algorithms. Computational capacity is expected to increase, facilitating ever more numerically intensive EMG algorithms that are likely to be developed in the future. The system described here has been used in the development of an adaptive window EMG amplitude-estimation algorithm. The system is extensible and can be altered for many uses related to EMG and biosignal processing.

Algorithms↗

Integration of analog and digital retinal tracking and coagulation subsystems.

Laser photocoagulation is used by ophthalmologists to treat retinal disorders such as diabetic retinopathy and retinal breaks and tears. Currently, the procedure is performed manually and suffers from several drawbacks: it often requires many clinical visits, it is very tedious for both patient and physician, the laser pointing accuracy and safety margin are limited by a combination of the physician's manual dexterity and the patient's ability to hold their eye still, and there is a wide variability in retinal tissue absorption parameters. This paper describes progress in developing a computer-assisted robotic laser system that will rapidly and safely place multiple therapeutic lesions at desired locations on the retina in a few seconds.

Analog-Digital Conversion↗

[Topographic distribution of visual evoked potentials in optic neuropathy].

INTRODUCTION: Digital treatment of electrical signals coming from the central nervous system on stimulation of the optic nerve path offers an objective method for evaluation of visual evoked potentials (VEP) shown graphically on a cerebral map. OBJECTIVE: To evaluate the topographical distribution of VEP in cases of optic neuropathy adding this parameter to the usual parameters of latency and amplitude. MATERIAL AND METHODS: We studied 35 patients with suspected optic neuropathy and normal findings on basic ophthalmological examination, in whom VEP and VEP mapping (VEPM) was done. RESULTS: In 26% of the cases there was no response for evaluation with the usual VEP recording techniques, whilst in those with VEPM this percentage was reduced to 11.5%. In the other cases there was a potential with characteristic distribution in the occipital areas and a maximally positive dipole posteriorly. CONCLUSION: VEPM is an objective method for evaluation of the visual pathway offering better discrimination than the usual VEP in more severe cases of neuropathy.

Adolescent↗

Hybrid retinal photocoagulation system using analog tracking.

We describe initial in vivo experimental results of a new hybrid digital and analog design for retinal tracking and laser beam control. An overview of the design is given. The results show in vivo tracking rates which exceed the equivalent of 38 degrees per second in the eye, with automated lesion pattern creation. Robotically-assisted laser surgery to treat conditions such as diabetic retinopathy and retinal breaks may soon be realized under clinical conditions with requisite safety using standard video hardware and inexpensive optical components based on this design.

Analog-Digital Conversion↗

A neural network approach to markerless measurement of human motion.

Most automatic motion analysis system operates by tracking markers across a field of view. The markers are usually attached to the skin at the joints. For some applications such as measuring the motion of elderly and the disabled persons, this approach can be uncomfortable which ultimately can affect the motion itself. The protocol of some markers can also be a problem for example active markers using infra-red LEDs must continuously be in the field of view of the detectors at all times. This will impose restriction in the motion. Therefore a marker free method is an attractive proposition. Such an approach would allow the subject to move freely thus exhibiting a more natural movement. We have developed a PC based system which uses frames from the video or photographic capture of a motion in the frontal and sagital plane. Key frames are selected and co-ordinate positions of the joints are identified. Joint angles are calculated from these positions based on a multiple link model of the human figure. The angles are then used as training data for a fully connected neural network. The neural network generates a model of the captured motion which is used to reproduce closely the actual motion.

Analog-Digital Conversion↗

Automated rodent respiratory monitor and histogram computer--a preliminary report.

The system described in this paper was designed to monitor total inhaled volume (V), tidal volume (VT), and respiratory frequency (f) of Fisher rats before, during, and after exposure to cigarette smoke. The systems consists of three major subsystems: plethysmograph, analog signal conditioner, and histogram computer. The volume type whole body plethysmograph incorporates a rubber nose seal. Tidal flow rate (V) from the tube, measured by a pneumotachometer, is integrated by the signal conditioning system to obtain VT and V. Both V and V are displayed on a strip chart recorder. A rat will often exhibit considerable sniffing, especially in the presence of cigarette smoke. Consequently, average tidal volume (VT) and average respiratory frequency (f) are not accurate measurements of typical VT and f. Sensitivity of the system to changes in typical VT and f is important snce the system will be used to evaluate the effects of subtle differences in types of experimental cigarettes. A microprocessor was used in conjunction with a cathode ray tube to compute and display both the VT and respiratory period (T = 1/f) as histograms. From the histograms the most common (typical) VT (mode of the histogram) and the most common T can be easily observed and recorded. The histogram computer also calculates and digitally displays VT and f.

Analog-Digital Conversion↗

A charge coupled transversal filter for biomedical signal conditioning.

The analysis and processing of biological signals is often hampered by the contamination of these low frequency, often low amplitude waveforms by motion artifact in fluid-filled catheter systems and skin electrodes, power line hum, and so on. Although noise suppression techniques have relied upon low pass filtration of the analog signals with active or passive RLC filters, even the most recent active RLC filter implementations display operational characteristics not entirely satisfactory for low frequency applications.

Analog-Digital Conversion↗

Physiological data collection system for field use in trained military dogs.

This research program resulted in synthesis of a complete system for "in the field" collection of dynamic physiologic data from trained military dogs. Sensors and sensor implantation techniques were developed for arterial blood pressure, electroencephalogram, electrooculogram, temperature, and respiratory rate monitoring in dogs under strenuous field conditions. A data acquisition system was developed that provided the capability for recording this physiologic data for later computer analysis, and computer programs were written for evaluation of the data. In the final evaluation of the system, two factors indicated a need for additional refinement: (1) that of reducing EEG signal artifact due to cable capacitance and, (2) signal jitter caused by the casette recorder.

Analog-Digital Conversion↗

ECG boy: low-cost medical instrumentation using mass-produced, hand-held entertainment computers. A preliminary report.

A prototype low-cost, portable ECG monitor, the "ECG Boy," is described. A mass produced hand-held video game platform is the basis for a complete three-lead, driven right-leg electrocardiogram (ECG). The ECG circuitry is planned to fit in a standard modular cartridge that is inserted in a production Nintendo "Gameboy." The combination is slightly smaller than a paperback book and weighs less than 500 g. The unit contains essential safety features such as optical isolation and is powered by 9-V and AA batteries. Functionally, the ECG Boy permits viewing ECG recordings in real time on the integrated screen. The user can select both the lead displayed on the screen and the time scale used. A 1-mV reference allows for calibration. Other ECG enhancements such as data transmission via telephone can be easily and inexpensively added to this system. The ECG Boy is intended as a proof of concept for a new class of low-cost biomedical instruments. Rising health care costs coupled with tightened funding have created an acute demand for low-cost medical equipment that satisfies safety and quality standards. A mass-produced microprocessor-based platform designed for the entertainment market can keep costs low while providing a functional basis for a biomedical instrument.

Analog-Digital Conversion↗