Inexpensive, semi-automated system for measuring mechanical properties of soft tissues.

Stiffness and strength are important properties of many tissues, but standard material-testing equipment is expensive, often ill-suited for testing soft tissues, and rarely accessible to biologists. We describe a system built around a microcomputer and an electronic balance which is particularly well-suited for measuring stress and strain in small samples of soft tissue. We use a discarded floppy disk drive as a linear actuator to strain the sample, while an electronic balance measures the tension (used to calculate stress). We give an algorithm for a program to drive a microcomputer which controls the floppy disk drive via its parallel port and records the balance measurements via its serial port. We used this system to obtain stress-strain curves from a sample of latex rubber and a sample of soft insect cuticle. Three tests of the rubber sample gave nearly identical results, with smooth, J-shaped stress-strain curves. The stress-strain curves gave a modulus elasticity value of 1.72 Mpa over the steep, straight region, well within the range for natural latex rubber. We also tested a sample of abdominal cuticle from a caterpillar (Manduca sexta). The caterpillar cuticle had a J-shaped stress-strain curve with a modulus of elasticity of 2.11 Mpa over the steep part of the curve. J. Exp. Zool. 284:374-378, 1999.

Animals↗

Protein adsorption onto ceramic surfaces.

Ceramics seldom have been used as blood-contacting materials. However, alumina ceramic (Al2O3) and polyethylene are incorporated into the pivot bearings of the Gyro centrifugal blood pump. This material combination was chosen based on the high durability of the materials. Due to the stagnant flow that often occurs in a continuous flow condition inside a centrifugal pump, pivot bearing system is extremely critical. To evaluate the thombogenicity of pivot bearings in the Gyro pump, this study sought to investigate protein adsorption, particularly albumin, IgG, fibrinogen, and fibronectin onto ceramic surfaces. Al2O3 and silicon carbide ceramic (SiC) were compared with polyethylene (PE) and polyvinylchloride (PVC). Bicinchoninic acid (BCA) protein assay revealed that the amount of adsorbed proteins onto Al2O3 and SiC was significantly less than that on PVC. The sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) indicated that numerous proteins adsorbed onto PVC compared to PE, Al2O3, and SiC. Identification of adsorbed proteins by Western immunoblotting revealed that the adsorption of albumin was similar on all four materials tested. Western immunoblotting also indicated lesser amounts of IgG, fibrinogen, and fibronectin on Al2O3 and SiC than on PE and PVC. In conclusion, ceramics (Al2O3 and SiC) are expected to be thromboresistant from the viewpoint of protein adsorption.

Adsorption↗

A comparative in vitro study of visible light-cured sealants.

The introduction of visible light polymerization in dentistry led to the development of a new generation of pit and fissure sealants. The purpose of this study was an overall evaluation of some in vitro characteristics of four new sealants (Delton LC, Helioseal, Pentra-Seal and Visioseal) in comparison with a chemically cured control (Delton). The results indicate that the monomer systems utilized in the new materials have already been used in dental polymer technology. The relatively new monomers TCDDMA/TCDMA were identified in one product. Camphoroquinone is used as a photoinitiator in all the light-cured systems which, after 40 s exposure, present better conversion than the control. The extent of oxygen inhibition was considerably reduced in the new sealants and the surface hardness was enhanced. Great differences were obtained in the penetration coefficient values; these, however, did not affect the enamel retention capacity of the materials tested. Consequently, light-cured sealants should be considered to be strongly compatible with the conventional chemically cured sealants from a laboratory aspect until more clinical evidence is available for their effectiveness in the prevention of pit and fissure decay.

Bisphenol A-Glycidyl Methacrylate↗

In vivo coefficient of kinetic friction: study of urinary catheter biocompatibility.

An animal model was developed to measure objectively the in vivo intrinsic coefficient of kinetic friction (COFk) of various catheter materials. Uncoated red rubber catheters had the highest COFk of the three materials tested. The Biocath catheter exhibited less COFk when compared with the standard silicone catheter. Although the etiology of urethral strictures is multifactorial, better biocompatibility as measured by in vivo COFk may be an important factor in the inevitable urethral trauma and irritation associated with indwelling catheterization and possibly with postcatheterization urethral stricture formation.

Animals↗

Long-term cytotoxicity of orthodontic direct-bonding adhesives.

The purpose of this study was to examine the potential toxic effects of several orthodontic adhesives immediately after polymerization and at various time intervals up to 2 years postopolymerization by means of an in vitro overlay assay. Adhesive samples were incubated on tissue cultures containing an agar overlay with a vital dye (neutral red). Viable cells were stained red; nonviable cells were unstained. The circular pattern of nonviable cells demonstrated a zone of inhibition that was measured and compared. All materials tested showed cytotoxic effects immediately after polymerization and the toxic effect decreased with time postpolymerization. However, 2 years after initial polymerization, significant zones of inhibition indicating continued in vitro toxicity were still evident in all but one of the adhesives.

Adhesives↗

Anterior vertebral body screw pullout testing. A comparison of Zeilke, Kaneda, Universal Spine System, and Universal Spine System with pullout-resistant nut.

STUDY DESIGN: A biomechanical study of pullout of anteriorly implanted screws in cadaveric vertebral bodies. OBJECTIVES: To investigate and compare the pullout strength of the Zielke, Kaneda, Universal Spine System (USS) pedicle screw, and USS pedicle screw with a new pullout-resistant nut. SUMMARY OF BACKGROUND DATA: A common problem with anterior purchase regardless of the implant system is screw pullout at the proximal and distal ends of multilevel constructs. There is limited information on a solution to this problem. METHODS: The L1 to L4 vertebral bodies from four cadavers had one each of Zielke and Kaneda pedicle screws (Acromed Corp., Cleveland, OH), USS pedicle screw (Synthes Spine, Paoli, PA), and USS pedicle screw with pullout-resistant nut implanted transversely across the center of the vertebral body with bicortical purchase in a similar fashion as would be used clinically. The screws were extracted using a servohydraulic material testing system. The maximum axial forces were recorded. RESULTS: The Zielke and Kaneda screws had no significant difference in mean pullout strength (P = 0.542). The USS screw alone was less strong (P = 0.009). The USS screw and pullout-resistant nut increased the pullout strength by twofold (P = 0.00006). In the screw pullout tests, the mode of failure was at the screw thread's interface. The USS screw and pullout-resistant nut failed by imploding the body around the nut. With the USS screw and pullout-resistant nut, the pullout strength was determined by the compressive strength of the bone. CONCLUSIONS: The addition of a pullout-resistant nut to an anterior vertebral body screw improves the pullout strength by twofold and changes the mode of failure to rely ultimately on the inherent vertebral body strength rather than the screw's characteristics. The addition of a pullout-resistant nut may be applicable to multilevel implant constructs to prevent screw pullout at the top and bottom.

Biomechanical Phenomena↗

Comparative study of the marginal microleakage of six cements in fixed provisional crowns.

STATEMENT OF PROBLEM: In many situations, provisional restorations require a long-term permanence in the oral cavity. During this period, the abutments need the best possible biologic and mechanical protection. In this way, the vitality of the pulp and the integrity of mineralized tissues can be preserved. The luting cement used to fix interim restorations should have good mechanical properties, low solubility, and good adhesion to resist bacterial and molecular penetration. However, because of its provisional nature, the prosthesis should be easy to remove from the abutments. These contrasting requirements may lead to a compromise in cement behavior, particularly in its mechanical properties. PURPOSE: This in vitro study evaluated the marginal microleakage of 4 provisional cements, a cavity base compound and a zinc-phosphate luting cement in provisional acrylic resin crowns fixed on extracted human teeth. MATERIAL AND METHODS: Thirty acrylic resin crowns were made and fitted on intact human premolars with the 6 cements. All restorations were applied in a standardized manner by means of an axial load of 10 kg. Specimens were thermocycled then submerged in a 5% basic fuchsin solution, then sectioned and observed under a light stereomicroscope. A 5-level scale was used to score dye penetration in the tooth/cement interface. RESULTS: A high dye penetration in the tooth/cement interface was present in all 4 provisional cements. Microleakage existed in specimens where zinc-phosphate and cavity base compounds were used; however, it was lower than the other materials. A significant difference (P < .05) was found between zinc-phosphate and one eugenol-free cement and between cavity base and the same eugenol-free cement. CONCLUSIONS: All materials tested demonstrated different degrees of microleakage. Zinc-phosphate and cavity base compound cements had the best sealing properties. This latter, even if conceived as a cavity base, may be considered a good provisional cement as far as microleakage is concerned.

Acrylic Resins↗

Thermal expansion and microstructural analysis of experimental metal-ceramic titanium alloys.

UNLABELLED: Statement of problem Low-fusing porcelains for titanium veneering have demonstrated inferior color stability and metal-ceramic longevity compared to conventional porcelains. PURPOSE: This study evaluated the microstructure and thermal expansion coefficients of some experimental titanium alloys as alternative metallic substrates for low-fusing conventional porcelain. MATERIALS AND METHODS: Commercially pure titanium (CP Ti) and various metallic elements (Al, Co, Sn, Ga, In, Mn) were used to prepare 8 titanium alloys using a commercial 2-chamber electric-arc vacuum/inert gas dental casting machine (Cyclarc). The nominal compositions of these alloys were the following (wt%): I: 80Ti-18Sn-1.5In-0.5Mn; II: 76Ti-12Ga-7Sn-4Al-1Co; III: 87Ti-13Ga; IV: 79Ti-13Ga-7Al-1Co; V: 82Ti-18In; VI: 75.5Ti-18In-5Al-1Co-0.5Mn; VII: 85Ti-10Sn-5Al; VIII: 78Ti-12Co-7Ga-3Sn. Six rectangular wax patterns for each test material (l = 25 mm, w = 3 mm, h = 1 mm) were invested with magnesia-based material and cast with grade II CP Ti (control) and the 8 experimental alloys. The porosity of each casting was evaluated radiographically, and defective specimens were discarded. Two cast specimens from CP Ti and alloys I-VIII were embedded in epoxy resin and, after metallographic grinding and polishing, were studied by means of scanning electron microscopy and wavelength dispersive electron probe microanalysis. One specimen of each material was utilized for the determination of coefficient of thermal expansion (CTE) with a dilatometer operating from room temperature up to 650 degrees C at a heating rate of 5 degrees C/minute. RESULTS: Secondary electron images (SEI) and compositional backscattered electron images (BEI-COMPO) revealed that all cast specimens consisted of a homogeneous matrix except Alloy VIII, which contained a second phase (possibly Ti(2)Co) along with the titanium matrix. The results showed that the coefficient of thermal expansion (CTE) varied from 10.1 to 13.1 x 10(-6)/ degrees C (25 degrees -500 degrees C), depending on the elemental composition. CONCLUSION: The CTE of titanium can be considerably changed by alloying. Two-phase alloys were developed when alloying elements were added in concentrations greater than the maximum solubility limit in alpha-titanium phase.

Aluminum↗

Effects of post-core design and ferrule on fracture resistance of endodontically treated maxillary central incisors.

STATEMENT OF PROBLEM: Studies concerning the effects of post-core design and ferrule on the fracture resistance of endodontically treated teeth remain controversial. PURPOSE: The purpose of this study was to investigate in vitro the effects of post-core design and ferrule on the fracture resistance of root canal treated human maxillary central incisors restored with metal ceramic crowns. MATERIAL AND METHODS: Forty-eight extracted human maxillary central incisors were endodontically treated and divided into 4 groups of 12. The following treatments were evaluated: group A: restored with metal ceramic (porcelain fused to metal [PFM]) crowns as control; group B: 2-mm ferrule/custom cast post-core/PFM crowns; group C: no ferrule/custom cast post-core/PFM crowns; and group D: 2-mm ferrule/prefabricated post and resin core/PFM crowns. Each specimen was subjected to load (N) on the lingual surface at a 135-degree angle to the long axis with a MTS 810 material testing machine until fracture at a crosshead speed of 0.02 cm/min. One-way analysis of variance and nonparametric chi-square test were used to compare the results. A significant analysis of variance result was followed by Newman-Keuls pairwise multiple comparisons (P<.05). RESULTS: There were significant differences among the 4 groups studied (P<.01). Group B had the highest fracture strength (1793.59 +/- 387.93 N). There was no significant difference among the fracture resistances of the other 3 groups (group A: 958.49 +/- 286.02 N; group C: 992.98 +/- 291.00 N; group D: 994.94 +/- 285.04 N). CONCLUSION: Within the limitations of this study, not all of the post-core structures tested improved the strength of the endodontically treated teeth. Those prepared with a 2-mm dentin ferrule more effectively enhanced the fracture strength of custom cast post-core restored endodontically treated maxillary central incisors.

Analysis of Variance↗

Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement.

STUDY DESIGN: Pedicle screws were pulled out of human cadaveric vertebrae before and after augmentation with polymethylmethacrylate or in situ-setting calcium phosphate cement. The fixation strength of screws augmented with calcium phosphate cement was compared with that of screws augmented with polymethylmethacrylate. OBJECTIVES: To determine whether a new in situ-setting calcium phosphate cement might be suitable for augmenting the fixation of pedicle screws. The principle objective was to compare the pull-out resistance of screws augmented with calcium phosphate cement with the pull-out behavior of screws augmented with polymethylmethacrylate. Polymethylmethacrylate augmentation was chosen as the standard because of its current clinical use. Five types of screws were tested to determine whether screw design had an effect on the efficacy of augmentation. SUMMARY OF BACKGROUND DATA: Although many factors affect the pull-out resistance of pedicle screws, a key determinant of their performance is the strength of their attachment to the spine. In elderly, osteopenic patients, the screw-bone interface is especially at risk for stripping during insertion or pull-out after surgery. In these patients, polymethylmethacrylate has been used to augment pedicle screw fixation, although its use is not without risk. In situ-setting calcium phosphate cements may provide an alternative to polymethylmethacrylate in this application. Like polymethylmethacrylate, calcium phosphate cements can be injected into the prepared screw hole. They have the added advantage of being resorbed and replaced during healing and normal bone remodeling. METHODS: Thirty human lower lumbar vertebrae (L3-L5) were implanted bilaterally with one of five types of pedicle screws (n = 6 for each screw type). The screws were pulled out 3.0 mm at 0.25 mm/sec with a servohydraulic materials testing machine. The 3.0-mm pull-out distance, which was slightly longer than one thread pitch, was designed to strip the screw-bone interface but to leave the pedicle otherwise intact. After the initial testing, the screws in each vertebrae were removed, and the screw tracks were filled with 2.0 cc of polymethylmethacrylate (one side) or calcium phosphate cement (contralateral side). After augmentation, the screws were reinserted, and the cements were allowed to harden for 24 hours. Postaugmentation testing followed the protocols for preaugmentation testing, and the pull-out resistance of screws augmented with calcium phosphate cement was compared with the pull-out resistance of screws augmented with polymethylmethacrylate. RESULTS: Mechanically, calcium phosphate cement compared favorably with polymethylmethacrylate for augmenting pedicle screws. Both restored the strength of the screw-bone interface: across all screw types, the average increase in pull-out strength was 147% with polymethylmethacrylate augmentation and 102% with calcium phosphate cement. There were no significant differences because of screw type with either type of augmentation. CONCLUSIONS: The in situ-setting calcium phosphate cement investigated in this study compared favorably with polymethylmethacrylate in a single-cycle, pull-out test of augmented pedicle screws in senile trabecular bone. With further evaluation, this cement may offer an alternative to polymethylmethacrylate for the enhancement of pedicle screw fixation clinically.

Bone Cements↗

Flexural strength distribution of a PMMA-based bone cement.

Polymethylmethacrylate bone cement containing either no added antibiotic or 0.5 g of Gentamicin was prepared and stored either in air at room temperature or in a 37 degree C water bath for 48 h. An additive-free cement stored in air at room temperature was also tested for purposes of comparison. Following storage the specimens were tested in flexure. Weibull statistics demonstrated to fit the flexural strength distribution of all the materials tested with regression coefficients of at least 0.98. The presence of a BaSO(4) radiopacifier markedly reduced the mean flexural strength and increased the data scatter in the air-stored specimens. On the other hand, the flexural strength of both impregnated and nonimpregnated antibiotic increased when those materials were stored in water at 37 degree C, compared with the same material stored in air, as a consequence of the water ingress. The water-stored antibiotic-impregnated cement displayed lower flexural strength, increased data scatter, and a remarkably higher number of weak specimens compared with the antibiotic-free cement. The influence of the load type on the flexural behavior was studied by testing the air-stored specimens in three-point bending and four-point bending. Cements tested in four-point bending resulted in lower flexural strength than that tested in three-point bending. The ratio of mean strength measured in the different load arrangements was satisfactory, as predicted by the Weibull model.

Anti-Bacterial Agents↗

The dynamic frictional resistance between orthodontic brackets and arch wires.

Limited published research on friction deals mainly with conventional stainless steel brackets and arch wires. However, the clinician can choose from a range of modern materials in determining arch wire and bracket combinations. This study quantifies the dynamic frictional force of sliding between different modern orthodontic brackets and arch wires. From the multitude of factors involved in the frictional process, the following were selected for investigation: arch wire material, bracket material, bracket-to-arch wire angulation, and lubrication (artificial saliva). The frictional force involved in sliding a ligated arch wire through a bracket slot was measured with a universal materials testing machine. A four-way analysis of variance was used to assess the results. Of the four factors investigated, all were found to have a significant influence on friction. Polycarbonate brackets showed the highest friction and stainless steel brackets the lowest. Friction increased with bracket-to-arch wire angulation. Lubrication significantly reduced friction. A range of 0.9 to 6.8 N frictional force was recorded. The actual force values recorded were most useful for comparing the relative influence of the factors tested on friction, rather than as a quantitative assessment of friction in vivo. The forces observed suggest that friction may be a significant influence on the amount of applied force required to move a tooth in the mouth. Hence, arch wire and bracket selection may be an important consideration when posterior anchorage is critical.

Aluminum Oxide↗

Influence of thermal cycles in water on flexural strength of laboratory-processed composite resin.

Recently a new generation of laboratory-processed composite resins containing submicron glass fillers was introduced, with claims of high strength. The purpose of this study was to evaluate the effect of thermal cycling in water on the flexural strength and hardness of several laboratory composite systems. The flexural strength of the new laboratory processed composite resins (Artglass [AG], Targis [TR] and Estenia [ES]) was significantly higher than that of conventional resins (Dentacolor [DC] and Cesead II [CS]). Thermocycling caused a reduction of the flexural strength but not a reduction of the hardness for most of materials tested. It was concluded that thermocycling affected the properties of the laboratory-processed hybrid type composite resin, ES, AG and TR. However, the changes of these properties were smaller than those of microfine type composite resin DC. Thus, ES, AG and TR may maintain better properties during service compared with DC.

Analysis of Variance↗

Effect of fluoride varnishes on color stability of esthetic restorative materials.

Fluoride varnish applications were applied to two hybrid resin composite materials, Z-100 (3M Dental Products, St Paul, MN, USA) and Esthet-X (Dentsply Caulk, Milford, DE, USA), shades A1 and A2 and a glass ionomer, GC Fuji IX GP Fast (GC Corporation, Tokyo, Japan), shade A2, to evaluate color stability. Specimens (12.6-mm dia x 2.3 mm) were prepared using a polyethylene frame, light-cured and polished through a 1-microm alumina finish. After the initial baseline color measurements, the discs were suspended in Fusayama artificial saliva (FAS) solution at 37 degrees C for 48 hours. Post immersion, the specimens were divided into five groups (n=15 each). The following fluoride varnishes were applied to four groups of test specimens: Duraphat (Colgate Oral Pharmaceutical, Inc, Canton MA, USA), Cavity Shield (OMNII Oral Pharmaceuticals, West Palm Beach, FL, USA), Duraflor (Pharmascience Inc, Montreal, Canada) and Fluor Protector (Vivadent, Ivoclar North America, Amherst, NY, USA). The varnish was allowed to dry for five minutes before immersion. The control group was not coated with varnish, although the specimens were immersed in FAS. All specimens were incubated in newly prepared FAS at 37 degrees C for 24 hours, cleaned with an electric toothbrush and the process repeated using newly prepared FAS. CIE L*a*b* color measurements were recorded five times: at baseline, after 48 hours FAS immersion, after cleaning the first and second fluoride varnish applications and after the final brushing using a commercial toothpaste (Crest). A Minolta CR-300 tristimulus colorimeter with an 8-mm aperture (Ramsey, NJ, USA) was used to record color measurements with the daylight (D65) setting. Calculations were performed for using CIE parameters deltaE*, deltaL*, delta a*, delta b*. Analysis of variance (ANOVA) and post-hoc test (Fisher's PLSD) were used for statistical analysis. After immersion in saliva, the tested glass ionomer (Fuji IX) produced the most significant color changes (deltaE*=1.19 and deltaL*=-1.03), indicating the effect of the color change was due to absorption. After fluoride varnish applications, Duraphat varnish produced significant changes in all tested materials and shades, resulting in color changes with deltaE greater than (>) 1 but less than (<) 3. These color changes are considered visually perceptible, yet have been reported in dental literature as clinically acceptable. Fluoride varnishes can be used without adversely affecting the color of restorative materials.

Absorption↗

Color stability of provisional resin restorative materials.

STATEMENT OF PROBLEM: Use of temporary crowns and fixed partial dentures is especially relevant when the treatment plan requires restorations for long interim periods, and the in-service discoloration of provisional restorative materials is a major drawback. PURPOSE: This study evaluated the discoloration effect of coffee and tea on some materials that are commonly used in the fabrication of provisional restorations. MATERIAL AND METHODS: Six commercially available provisional resins (Jet, Caulk TBR, Protemp Garant, Luxatemp Solar, Provipont DC and SR-Ivocron-PE) were evaluated after 1 day, 7 days, and 30 days of immersion in various staining solutions. Color measurements were obtained by using a Dr Lange Micro Color tristimulus colorimeter and color differences (delta E*) were estimated. RESULTS: The 2 chemically activated resins (Jet and Caulk TBR) and the heat-cured resin (SR-Ivocron PE) exhibited the least color changes, whereas the Provipont-DC resin was the least color stable. After immersion for 30 days, the combination with the coffee solution resulted in unacceptable discoloration for all the tested materials. CONCLUSIONS: Provisional restorative materials, staining solutions, and immersion time were significant factors that affected color stability. After immersion for 7 days, all materials showed observable color changes. The composite-based materials, especially light-curing composites, were the least color stable. The coffee solution exhibited more staining capacity than the tea solution.

Analysis of Variance↗

[Composites versus amalgam: comparative measurements of abrasion resistance in vivo: 1-year results].

A method for the in-vivo measurement of wear resistance of restorative materials is described. A profilometer is used to record the reduction in vertical dimension of the test material's occlusal surface. This loss of substance is calculated as the wear resistance index. The technique was used in a 13 month clinical evaluation of 3 different restorative materials, Adaptic, Amalgam (Dispersalloy) and Estic microfill. The procedure is simple in execution and very accurate. Statistical analysis has shown significant differences in wear resistance of the examined materials independent of patient variation. Attrition and abrasion were definitely greater with a standard composite material (Adaptic) than with amalgam and a test composite (Estic microfill). The newly developed composite material utilizing extremely fine filler particles of pyrogenic SiO2 (Estic microfill) was shown to be comparable to amalgam in wear resistance during the 13-month test period.

Adult↗

A biomechanical analysis of triangulation of anterior vertebral double-screw fixation.

OBJECTIVE: This study tested the hypothesis that triangulation of two anterior vertebral screws without penetration of the cortex offers more resistance to pullout than two screws placed in parallel and penetrated. DESIGN: The pullout strength for two parallel or two triangulated anterior vertebral screws fixation, with a uni-cortical or bi-cortical purchase, were tested and compared to the strength of a single-screw fixation with a bi-cortical purchase. Four porcine spines (six months old) were used for biomechanical test and bone mineral density was measured for each specimen before testing. BACKGROUND: The potential hazards from penetration by anterior vertebral cortex screws including neurovascular and organs injuries are well documented. However, bi-cortical screw penetration is widely recognized as necessary for good anterior spinal stabilization. The authors are not aware of any biomechanical study on the anterior placement of triangulated vertebral screws without penetration and its effect on the fixation strength of anterior vertebral device remains unclear. METHODS: In this study five modes of screw fixations in lateral vertebral bodies were performed: Group A, triangulated screws with one screw penetration; Group B, triangulated screws without penetration; Group C, parallel penetrating screws; Group D, parallel nonpenetrating screws; and Group E, a single-screw with bi-cortical purchase. Biomechanical analysis with a material testing system machine was performed to determine the pull out strength of each configuration. RESULTS: The results showed that the pullout strength in the various double-screw fixation modes were statistically increased as compared to that of the single-screw with bi-cortical purchase mode. There existed statistical differences (P<0.05) between Groups A and B, Groups C and D and Groups D and E, respectively. However, no significant difference was found between Groups B and C (P=0.144). CONCLUSIONS: Based on the current data, triangulation of two anterior vertebral screws without penetration of the cortex (Group B) achieved pullout strengths similar to that of two-parallel double-cortical screws (Group C). The authors believe that this is an attractive alternative in anterior spinal instrumentation avoiding the potential risks of cortical penetration. However, in the event of pullout failure, the triangulation configuration will produce a more disastrous consequence. RELEVANCE: Triangulation of two anterior vertebral screws without penetration of the cortex achieve pullout strengths similar to that of two-parallel double-cortical screws. This is an attractive alternative in anterior spinal instrumentation that avoids the potential risks of cortical penetration.

Analysis of Variance↗

[The effect of adding cefobid upon the physiochemical properties of calcium phosphate cement].

This study was conducted to analyze the physiochemical properties of different mass ratio compounds of cefobid-load calcium phosphate cement(CPC). The compounds of 0%, 2.9%, 4.8% and 7.4% mass ratio cefobid-load CPC were made respectively. The setting time was observed; the compressive strength of compounds was measured by a material testing machine; the construction of compounds was observed by scanning electron microscopy(SEM) and analyzed by EIG. The results showed that both the setting time and the ratio of hole did not change obviously after the addition of cefobid, but the ultimate compressive strength decreased slowly and the results of the four groups were (21.98 +/- 1.06)MPa, (21.38 +/- 0.95)MPa, (19.22 +/- 1.11)MPa and (13.5 +/- 1.65)MPa respectively. These data indicate there is no obvious effect on the physicochemical properties of calcium phosphate cement after the addition of cefobid between 0% and 4.8%. The compounds have irregular holes and hence a good ability of compressive strength. It might be a new bone grafting material for the reparation of infection-related bone defects.

Biomechanical Phenomena↗