PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

Development and validation of an optical SPR biosensor assay for tylosin residues in honey.

In recent years there has been an increase in the use of tylosin in apiculture as bacterial brood diseases become resistant to oxytetracycline. Confirmatory mass spectrometry based methods have been developed but up until now there has been no complementary screening method available capable of sub 10 microg kg(-1) detection limits. In this paper the development and validation of a screening method using optical biosensor technology is presented. The honey was first dissolved in a phosphate buffer and following solid-phase extraction (SPE) cleanup was analyzed using a Biacore Q instrument. Using the criteria specified in European Commission Decision 2002/657/EC for qualitative screening methods, the detection capability (CCbeta) of the method was determined to be 2.5 microg kg(-)(1). Honey samples containing trace residue levels of tylosin were analyzed by both the biosensor screening method and a LC-MS/MS confirmatory procedure; the results were in good agreement.

Anti-Bacterial Agents↗

Cast thin film biosensor design based on a Nafion backbone, a multiwalled carbon nanotube conduit, and a glucose oxidase function.

Novel electroanalytical sensing nanobiocomposite materials are reported. These materials are prepared by mixing multiwalled carbon nanotubes (MWNTs), a Nafion cation exchanger, and glucose oxidase (GOD) in appropriate amounts. The MWNTs are cylindrical with a diameter in the range 40-60 nm and with a length of up to several micrometers, and they provide electrical conductivity. Nafion acts as a polymer backbone to give stable and homogeneous cast thin films. Both MWNTs and Nafion provide negative functionalities to bind to positively charged redox enzymes such as glucose oxidase. The resulting biosensing composite material is inexpensive, reliable, and easy to use. The homogeneity of the MWNT-Nafion-GOD nanobiocomposite films was characterized by atomic force microscopy (AFM). Amperometric transducers fabricated with these materials were characterized electrochemically using cyclic voltammetry and amperometry in the presence of hydrogen peroxide and in the presence of glucose. Their linear response to hydrogen peroxide was demonstrated. The glucose biosensor sensitivity was strongly influenced by the glucose oxidase concentration within the nanobiocomposite film. The optimized glucose biosensor (2.5 mg/mL GOD) displayed a sensitivity of 330 nA/mM, a linear range of up to 2 mM, a detection limit of 4 microM, and a response time of <3 s.

Biosensing Techniques↗

Study of the interaction between different phosphodiesterases and yessotoxin using a resonant mirror biosensor.

Yessotoxins (YTXs) are disulfated polyether toxins that were first isolated from scallops in Japan. It has been proposed that these toxins activate cellular phosphodiesterases (PDEs). The interaction between YTX and PDEs was confirmed by resonant biosensor and fluorescence polarization studies. The aim of this work is to study the specificity of different PDEs for YTX binding. Association measurements are done in a resonant mirror biosensor. The instrument detects changes in the refractive index and/or thickness occurring within a few hundred nanometers from the sensor surface where the association PDEs-YTX takes place. We use aminosilane cuvettes, where exonuclease Phosphodiesterase I from Crotalus atrox (PDE I), exonuclease Phosphodiesterase II from bovine spleen (PDE II), or phosphodiesterase 3',5'-cyclic-nucleotide-specific from bovine brain (PDEs) are immobilized. Over immobilized exonuclease PDE I and exonuclease PDE II are added different amounts of YTX, and typical association curve profiles are observed. These association curves fit a pseudo-first-order kinetic equation where the apparent association rate constant (k(on)) can be calculated. The value of this constant increases with YTX concentration. From the representation of k(on) versus YTX concentration, the association rate constant (k(ass)) and the dissociation rate constant (k(diss)) are obtained. From these values, the kinetic equilibrium dissociation constant (K(D)) of the YTX-PDE association can be calculated, indicating the affinity between them. The specificity of cyclic nucleotide PDE families is studied using different inhibitors that are added over immobilized cyclic nucleotide PDEs. In these conditions, changes in the association PDEs-YTX curves are detected. The results show YTX affinity by cyclic nucleotide PDE 1, PDE 3, PDE 4, and exonuclease PDE I.

Animals↗

Use of a luminescent bacterial biosensor for biomonitoring and characterization of arsenic toxicity of chromated copper arsenate (CCA).

An arsenic oxyanion-inducible Escherichia coli chromosomal operon (arsRBC) has been previously identified. Construction of a luciferase transcriptional gene fusion (arsB::luxAB) showed that ars operon expression, plus concomitant cell luminescence, was inducible in a concentration-dependent manner by arsenic salts. The present study was conducted to evaluate the potential of the arsB::luxAB transcriptional gene fusion for use as a biosensor in monitoring the toxicity of arsenic compounds. Cultures from this gene fusion strain were exposed to increasing concentrations of the wood preservative chromated copper arsenate (CCA), as well as its constituents, sodium arsenate and chromated copper solution (CC). Analysis of luciferase activity revealed that the arsB::luxAB gene fusion was expressed in response to CCA and sodium arsenate, but not to the CC solution. The detection limit of arsenic was found to be 0.01 microgram As/ml (10 parts per billion, 10 ppb) and therefore well within the range of environmental concerns. A greater induction of luminescence by arsenate was observed when cells were limited for phosphate, as phosphate can act as a competitive inhibitor of arsenate ions. Our results suggest that the E. coli arsB::luxAB fusion strain has a promising future as a specific and sensitive biosensor for monitoring bioavailable levels and toxicity of arsenic near sites where CCA-treated wood has been used.

Arsenates↗

Analysis of bispecific monoclonal antibody binding to immobilized antigens using an optical biosensor.

The interaction between two different monoclonal antibodies (Mabs) and their corresponding bispecific antibodies (Babs) with immobilized antigens was investigated using an optical biosensor (IAsys). The analyzed panel of affinity-purified antibodies included two parental Mabs (one of which was specific to human IgG (hIgG), and another one to horseradish peroxidase (HRP)), as well as Babs derived thereof (anti-hIgG/HRP). Babs resulting from the fusion of parental hybridomas bear two antigen-binding sites toward two different antigens and thus may interact with immobilized antigen through only one antigen-binding site (monovalently). Using an IAsys biosensor this study shows that the bivalent binding of Mabs predominates over the monovalent binding with immobilized HRP, whereas anti-hIgG parental Mabs were bound monovalently to the immobilized hIgG. The observed equilibrium association constant (K(ass)) values obtained in our last work [1] by solid-phase radioimmunoassay are consistent with those constants obtained by IAsys. The K(ass) of anti-HRP Mabs was about 50 times higher than that of anti-HRP shoulder of Babs. The dissociation rate constant (k(diss)) for anti-HRP shoulder of Babs was 21 times higher than k(diss) for anti-HRP Mabs. The comparison of the kinetic parameters for bivalent anti-HRP Mabs and Babs derived from anti-Mb/HRP and anti-hIgG/HRP, allowed to calculate that 95% of bound anti-HRP Mabs are bivalently linked with immobilized HRP, whereas only 5% of bound anti-HRP Mabs are monovalently linked. In general, the data obtained indicate that Babs bearing an enzyme-binding site may not be efficiently used instead of traditional antibody-enzyme conjugates in the case of binding of bivalent Mabs.

Antibodies, Monoclonal↗

Biosensor based on Langmuir-Blodgett films of poly(3-hexyl thiophene) for detection of galactose in human blood.

An amperometric biosensor was developed to estimate galactose in human blood serum. Monolayers of poly(3-hexyl thiophene) were placed on glass plates coated with indium tin oxide formed by dispensing a mixed solution of stearic acid in chloroform on to a water sub-phase. Galactose oxidase was mixed with poly(3-hexyl thiophene)/stearic acid in chloroform and dispensed on to the air-water interface of Langmuir-Blodgett trough. These monolayers were transferred on to glass plates which were used as working electrodes with platinum as a reference electrode. The amperometric galactose biosensor thus fabricated had a linear response from 0.05 to 0.5 g galactose l(-1) in blood serum. The normal level in blood is < 0.05 g galactose l(-1) in adults and 0-0.2 g galactose l(-1) in infants. In case of galactosemia, this increases to above 0.2 g galactose l(-1) in infants.

Adult↗

Colorimetric biosensors based on DNAzyme-assembled gold nanoparticles.

Taking advantage of recent developments in the field of metallic nanoparticle-based colorimetric DNA detection and in the field of in vitro selection of functional DNA/RNA that can recognize a wide range of analytes, we have designed highly sensitive and selective colorimetric biosensors for many analytes of choice. As an example of the sensor design strategy, a highly sensitive and selective colorimetric lead biosensor based on DNAzyme-directed assembly of gold nanoparticles is reviewed. The DNAzyme consists of an enzyme and a substrate strand, which can be used to assemble DNA-functionalized gold nanoparticles. The aggregation brings gold nanoparticles together, resulting in a blue-colored nanoparticle assembly. In the presence of lead, the DNAzyme catalyzes specific hydrolytic cleavage of the substrate strand, which disrupts the formation of the nanoparticle assembly, resulting in red-colored individual nanoparticles. The application of the sensor in lead detection in leaded paint is also demonstrated. In perspective, the use of allosteric DNA/RNAzymes to expand the range of the nanoparticle-based sensor design method is described.

Biosensing Techniques↗

Protein-based biosensors for diabetic patients.

In this article we show the recent progress in the field of glucose sensing based on the utilization of enzymes and proteins as probes for stable and non-consuming fluorescence biosensors. We developed a new methodology for glucose sensing using inactive forms of enzymes such as the glucose oxidase from Aspergillus niger, the glucose dehydrogenase from the thermophilic microorganism Thermoplasma acidophilum, and the glucokinase from the thermophilic eubacterium Bacillus stearothermophilus. Glucose oxidase was rendered inactive by removal of the FAD cofactor. The resulting apo-glucose oxidase still binds glucose as observed from a decrease in its intrinsic tryptophan fluorescence. 8-Anilino-1-naphthalene sulfonic acid was found to bind spontaneously to apo-glucose oxidase as seen from an enhancement of the ANS fluorescence. The steady state intensity of the bound ANS decreased 25% upon binding of glucose, and the mean lifetime of the bound ANS decreased about 40%. These spectral changes occurred with a midpoint from 10 to 20 mM glucose, which is comparable to the KD of holo-glucose oxidase. The ANS-labeled apo-glucose dehydrogenase from Thermoplasma acidophilum also displayed an approximate 25% decrease in emission intensity upon binding glucose. This decrease can be also used to measure the glucose concentration. The thermophilic apo-glucose dehydrogenase was also stable in the presence of organic solvents, allowing determination of glucose in the presence of acetone. The third enzyme used for glucose sensing was the glucokinase from Bacillus stearothermophilus. A fluorescence competitive assay for the determination of glucose was developed based on the utilization of this thermostable enzyme. Taken together, our results show that enzymes which use glucose as their substrate can be used as reversible and non-consuming glucose biosensors in the absence of required co-factors. Moreover, the possibility of using inactive apo-enzymes for a reversible sensor greatly expands the range of proteins which can be used as sensors, not only for glucose, but for a wide variety of biochemically relevant analytes.

Anilino Naphthalenesulfonates↗

Measurement of the affinity of melittin for zwitterionic and anionic membranes using immobilized lipid biosensors.

The binding of melittin to zwitterionic dimyristyphosphatidylcholine (DMPC) and anionic dimyristylphosphatidylglycerol (DMPG) was analysed using two different immobilized model membrane systems. The first system used surface plasmon resonance (SPR), which monitors the real-time binding of peptides to an immobilized hybrid bilayer. SPR experiments reflected a stronger binding of melittin for DMPG than for DMPC, while kinetic analysis suggested the existence of at least two distinct binding steps. The second lipid biosensor system involved an immobilized phospholipid monolayer covalently attached to a microporous silica surface. The binding of melittin to the immobilized monolayer was then monitored using dynamic elution chromatography with varied methanol concentrations to analyse the binding of melittin to DMPC and DMPG. The nonlinear binding behaviour observed for melittin with the phosphatidylcholine (PC) and phosphatidylglycerol (PG) monolayers compared with the linear retention plots and Gaussian peak shapes observed for the control molecule demonstrated that melittin undergoes significant conformational and orientational changes upon binding to the immobilized PC and PG ligands. The dependence of log k' on per cent methanol also demonstrated a bimodal interaction whereby hydrophobic forces predominated at higher temperatures and methanol concentrations, while other forces, presumably electrostatic in nature, also made a contribution to the affinity of the peptides for the lipid monolayer, particularly at lower temperatures. The complementary use of these two lipid biosensors thus allows the role of hydrophobic and electrostatic forces in peptide-membrane interactions to be studied.

Anions↗

A biosensor that uses ion-channel switches.

Biosensors are molecular sensors that combine a biological recognition mechanism with a physical transduction technique. They provide a new class of inexpensive, portable instrument that permit sophisticated analytical measurements to be undertaken rapidly at decentralized locations. However, the adoption of biosensors for practical applications other than the measurement of blood glucose is currently limited by the expense, insensitivity and inflexibility of the available transduction methods. Here we describe the development of a biosensing technique in which the conductance of a population of molecular ion channels is switched by the recognition event. The approach mimics biological sensory functions and can be used with most types of receptor, including antibodies and nucleotides. The technique is very flexible and even in its simplest form it is sensitive to picomolar concentrations of proteins. The sensor is essentially an impedance element whose dimensions can readily be reduced to become an integral component of a microelectronic circuit. It may be used in a wide range of applications and in complex media, including blood. These uses might include cell typing, the detection of large proteins, viruses, antibodies, DNA, electrolytes, drugs, pesticides and other low-molecular-weight compounds.

Biosensing Techniques↗

Proteomic applications of surface plasmon resonance biosensors: analysis of protein arrays.

Proteomics is one of the most important issues in the post-genomic area, because it can greatly contribute to identifying protein biomarkers for disease diagnosis and drug screening. Protein array is a key technology for proteome researches and has been analyzed by various methods including fluorescence, mass spectrometry, atomic force microscopy and surface plasmon resonance (SPR). SPR biosensor is a promising technology in proteomics, since it has various advantages including real-time measurement of biomolecular interactions without labeling and the simple optical system for the device. SPR biosensors have a strong potential for analyzing proteomes by SPR imaging and SPR spectroscopic imaging, even though the challenge is to produce proteins on a proteomic scale.

Animals↗

Real-time multiplex analysis of four beta-thalassemia mutations employing surface plasmon resonance and biosensor technology.

In this paper, biospecific interaction analysis (BIA) employing surface plasmon resonance (SPR) and biosensor technologies was applied to the analysis of multiple mutations of the human beta-globin gene. To this aim, large target polymerase chain reaction (PCR) products were immobilized on sensor chips and then probes detecting beta degrees 39 (C>T), beta degrees IVSI-1 (G>A), beta(+)IVSI-6 (T>C) and beta(+)IVSI-110 (G>A) thalassemia mutations were sequentially injected. In this study, a total of ten normal and seven heterozygous subjects, and six homozygous patients were considered. The results obtained allow to conclude that discrimination between normal subjects, heterozygous, and homozygous patients is readily achieved for all the four mutations by PCR amplification of genomic DNA containing all the regions corresponding to the same mutations, immobilization of the same PCR products, and hybridization. To our knowledge the procedure described here is the first reported on the use of SPR-based BIA and biosensor technology for multiple detections of point mutations.

Base Sequence↗

Continuous, noninvasive monitoring of local microscopic inflammation using a genetically engineered cell-based biosensor.

Using an inflammation-responsive regulatory element as a molecular sensor, we established a cell-based biosensor for continuous, noninvasive monitoring of local microscopic inflammation in vivo. Glomerular mesangial cells were stably transfected with a marker gene encoding secreted alkaline phosphatase (SEAP) under the control of the kappaB enhancer elements. The established cells secreted SEAP in vitro in response to proinflammatory cytokines as well as to soluble factors produced by inflamed glomeruli. To examine feasibility of using the established cells for in vivo monitoring of local microscopic inflammation, the sensor cells were transferred selectively into rat glomeruli via the renal circulation. After induction of acute glomerulonephritis, the serum level of SEAP was increased transiently in cell-transferred nephritic rats. The kinetics of serum SEAP was closely correlated with the natural course of the inflammation, and the increase in SEAP was attenuated by suppression of inflammation using an immunosuppressive drug, cyclophosphamide. Neither cell-transferred normal rats nor nephritic rats without cell transfer exhibited increase in the serum level of SEAP. When the sensor cells were transferred extrarenally, elevation of serum SEAP was not observed in nephritic rats, confirming that the locally settled sensor cells responded only to local inflammation. These results suggested that, without invasive procedures like tissue biopsies, continuous monitoring of microscopic inflammation is feasible in vivo via locally created, cell-based biosensors.

Acute Disease↗

A carbohydrate biosensor surface for the detection of uropathogenic bacteria.

We have developed a new surface for use in biosensors that is based on a gold plate covered with a specific carbohydrate receptor structure. The carbohydrate, Gal alpha 1-4Gal, was bound covalently via a thioalkylcarboxy-spacer, or adsorbed as a neoglycoprotein, to a two-dimensional gold surface. Both types of surfaces showed high specificity in the binding of the uropathogenic bacteria P-fimbriated Escherichia coli compared to the binding of non-infectious bacteria. The signal to noise ratio is sufficiently high to allow specific detection of the bacteria in biosensor applications.

Adsorption↗

A single-use luciferase-based mercury biosensor using Escherichia coli HB101 immobilized in a latex copolymer film.

A single-use Hg(II) patch biosensor has been developed consisting of 1.25-cm diameter patches of two acrylic vinyl acetate copolymer layers coated on polyester. The top layer copolymer was 47 microm thick whereas the bottom layer of copolymer plus E. coli cells was 30 microm thick. The immobilized E. coli HB101 cells harbored a mer-lux plasmid construct and produced a detectable light signal when exposed to Hg(II). The immobilized-cell Hg(II) biosensor had a sensitivity similar to that of suspended cells but a significantly larger detection range. The levels of mercury detected by the patches ranged from 0.1 nM to 10 000 nM HgCl2 in pyruvate buffer, and luciferase induction as a function of Hg(II) concentration was sigmoidal. Luciferase activity was detected in immobilized cells for more than 78 h after exposure of the cells to HgCl2. Addition of 1 mM D-cysteine to the pyruvate buffer increased luciferase induction more than 100-fold in the immobilized cell patches and 3.5-fold in a comparable suspension culture. The copolymer patches with immobilized cells were stable at -20 degrees C for at least 3 months, and the Hg(II)-induced luciferase activity after storage was similar to that of samples assayed immediately after coating. Patches stored desiccated at room temperature for 2 weeks showed lower mercury-induced luciferase activity when compared to freshly prepared patches, but they still had a considerable detection range of 1 to 10 000 nM HgCl2.

Biosensing Techniques↗

Microbial detection by a glucose biosensor coupled to a microdialysis fibre.

The use of a glucose biosensor coupled to microdialysis sampling in a flow injection analysis system is described to follow the growth of Escherichia coli in a glucose-containing liquid culture medium. The experimental set-up permitted a throughput rate of 25 samples h-1. Growth curves were modelled by a modified Gompertz equation, which permitted the determination of lag time and maximum specific growth rate. The time required to produce an appreciable variation in the biosensor response (minimum detection time, MDT) was determined. A plot of MDT versus microbial concentration was found to be linear in the range 10(6)-10(10) colony forming units (cfu) ml-1. A microbial concentration of 10(6) cfu ml-1 can be detected after about 5 h.

Bacteriological Techniques↗

Biosensor for neurotransmitter L-glutamic acid designed for efficient use of L-glutamate oxidase and effective rejection of interference.

An amperometric biosensor for L-glutamic acid (Glu) was constructed by the adsorption and dip coating of L-glutamate oxidase (GluOx, 200 U ml-1 phosphate buffer, pH 7.4) onto 60-micron radius Teflon-coated Pt wire (1 mm exposed length). The enzyme was then trapped on the surface by electropolymerisation of o-phenylenediamine that also served to block electroactive interference. This procedure afforded electrodes with similar substrate sensitivity compared with the classical approach of immobilising enzyme from a solution of monomer, and represents an approximately 10,000-fold increase in the yield of biosensors from a batch of enzyme. A number of strategies were examined to enhance the sensitivity and selectivity of the Pt/PPD/GluOx sensors operating at 0.7 V versus SCE. Pre-coating the Pt with lipid and incorporation of the protein bovine serum albumin into the polymer matrix were found to improve the performance of the electrode. The sensors had a fast response time, high sensitivity to Glu, with an LOD of about 0.3 mumol l-1, and possessed selectivity characteristics suggesting that monitoring Glu in biological tissues in vivo may be feasible.

Amino Acid Oxidoreductases↗

Trends in electrochemical biosensors.

The development of electrochemically based biosensors is discussed in the context of what has been learned from the successful development of glucose biosensors. Some future trends are discussed.

Biosensing Techniques↗