PubMed HealthSearch

SEARCH · PubMed Health

Results for “Flow Injection Analysis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Amperometric flow-injection analysis of creatinine based on immobilized creatinine deiminase, leucine dehydrogenase and L-amino acid oxidase.

Leucine dehydrogenase/L-amino acid oxidase was proposed as an enzymatic conversion system for ammonia and its application to amperometric assay of creatinine was investigated. Ammonia formed by creatinine deiminase catalyzed hydrolysis of creatinine was converted to L-leucine by leucine dehydrogenase, and the oxidation of L-leucine by L-amino acid oxidase was detected with an oxygen electrode. Two approaches were proposed to overcome the problem of endogenous ammonia and L-amino acids. The first was using glutamate dehydrogenase prereactor to remove endogenous ammonia; endogenous L-amino acids were corrected by a separate run. In the second approach, endogenous ammonia and L-amino acids were simultaneously compensated with a two-channel system. It resulted in double peak recording that the flow was split and rejoined between the two ends of creatinine deiminase reactor and a delay coil and a reference column were properly set at one of the two-channels. One gave the sum response of all responsible compounds, the other that of endogenous interferences except creatinine. Both approaches were applied to creatinine assay in urine and the results showed a good agreement with those obtained from the Jaffe method.

Amino Acid Oxidoreductases

Measurement of protein using flow injection analysis with bicinchoninic acid.

We have used the bicinchoninic acid reagent developed by Pierce Chemical Co. to measure proteins in a simple flow injection analyzer. The sensitivity is comparable to that of the Lowry method and no pipetting of reagents is needed. Results are obtained in less than 1 min and samples may be run at a rate of 60/h. The response is linear over a range of protein concentration (0-10 micrograms) and sample size (5-20 microliters) convenient for most analytical requirements. A peristaltic pump, a controlled-temperature water bath, and a spectrophotometer with flow cuvette are the only special apparatus required.

Proteins

[Determination of tetracyclines by flow injection analysis].

An accurate, convenient and fast method was proposed for the determination of tetracyclines (tetracycline, chlortetracycline, oxytetracycline, doxycycline and methacycline) and their preparations by flow injection detector based on tetracycline flow-through sensor. The parameters affecting the measurement were discussed. The detector can respond to tetracycline, chlortetracycline, oxytetracycline, doxycycline and methacycline, at the same time. Their slopes are 51-55 mV/decade over the concentration range of 10(-2)-5 x 10(-5) mol/L at pH 1.5-3.5. The results obtained are in good agreement with those by biological assay (less than 3% deviation). One hundred samples can be determined in an hour.

Electrochemistry

Flow injection analysis using ion-sensitive field effect transistors. A model system for discrete assays and continuous in vitro monitoring of pH and pCa.

A miniaturized flow injection system yields an instant readout and requires microlitre volumes of sample and reagent solutions. Using electrode measurement as an example it is shown that the difference between discrete assays and continuous monitoring becomes so small that the same apparatus will eventually perform both functions.

Calcium

Flow-injection analysis of amino acids and their metabolites by immobilized vitamin B6-dependent enzymes. Sensitive determination of L-aspartate, L-glutamate, 2-oxoglutarate, and oxaloacetate.

Sensitive flow-injection analyses of aspartate, glutamate, 2-oxoglutarate, and oxaloacetate were developed. The analytes were enzymatically coupled with NADH which was monitored by light emission from immobilized bacterial bioluminescence enzymes. Aspartate (or oxaloacetate) was assayed on the basis of NADH consumption by introducing the sample through a coimmobilized aspartate aminotransferase-malate dehydrogenase column. The assay responded linearly from 100 pmoles to 5 nmoles per assay. Glutamate (2-oxoglutarate) was determined by formation of NADH in the glutamate dehydrogenase reaction. The measuring range for glutamate was from 10 pmoles to 100 nmoles per assay. The precision of the flow-injection method was generally excellent, and the sensitivities of the described assays were 100-1000-fold higher than with spectrophotometric methods. The immobilized enzyme preparations were stable for several months in storage, and the enzyme columns could be used for 600-800 analyses. Flow-injection analyses of amino acids and related compounds by NADH/bioluminescence-coupled reactions provide a sensitive, fast, and inexpensive assay method for a wide variety of purposes.

Animals

Determination of total cholesterol in serum by flow injection analysis with immobilized enzymes.

Several photometric and fluorimetric methods are proposed for the determination of cholesterol by use of enzymes immobilized on controlled-pore glass and the normal and stopped-flow injection modes, achieving linear ranges of the calibration curves between 26-776 mumol/l and 5-265 mumol/l with excellent regression coefficients and good coefficients of variation. The methods have been applied to the determination of this analyte in serum with excellent results.

Cholesterol

Serum iron and total iron-binding capacity determination by flow-injection analysis with atomic absorption detection.

The deproteinised sample (150 microliters) is 'injected' into a continuously flowing stream of deionised water which is pumped, via a capillary tube, to the nebuliser of an atomic absorption spectrophotometer. Analytical readout is obtained, in the form of transient peaks, 6 s after sample injection. Before injection traces of haemoglobin are removed from the serum by treatment with trichloroacetic acid-ascorbate solution. This protein precipitant facilitates rapid removal of haemoglobin bound iron without the need for heating. After centrifugation the supernatant solution is introduced into the flowing stream by use of a novel inexpensive 'injector'. Analytical recovery and precision are good, and results compare well with those obtained by a standard AutoAnalyzer procedure.

Autoanalysis

Automated fluoroimmunoassay of theophylline and valproic acid by flow-injection analysis with use of HPLC instruments.

For automated determination of theophylline and valproic acid by use of Ames' fluoroimmunoassays we used a high-pressure liquid-chromatographic system consisting of a pump, a robotic unit (Gilson 231/401, to prepare and inject the samples into the flowing carrier), and a fluorometer with a 10-microL flow cell. Results correlated well with those of conventional liquid- and gas-chromatography (r less than 0.96). The between-run CV is about 5%. In comparison with the manual method, the volume of reagents (and thus the cost per analysis) was decreased by eightfold.

Autoanalysis

A flow injection analysis system involving immobilized NADH oxidase in column form for clinical analysis.

A highly sensitive FIA system for chemiluminometric determination of reduced coenzyme, NADH, was developed, using immobilized NADH oxidase from Brevibacterium ammoniagenes. The enzyme catalyzed the oxidation of NADH generating hydrogen peroxide which emitted chemiluminescence when mixed with luminol and potassium ferricyanide. The immobilized enzyme reactor was a mini-column, measuring 1 or 2 mm in inner diameter and 20 mm in length, and the sample volume was only 1 microliter per assay, with a feeding speed of one sample per min and a lowest detection limit of 10 pmol NADH. A FIA system was also developed for the determination of magnesium in human serum, using an enzyme column reactor with simultaneously coimmobilized hexokinase, D-glucose-6-phosphate dehydrogenase, and NADH oxidase. The performance of the system was as satisfactory as a routine colorimetric assay, but with much higher sensitivity.

Colorimetry

Rapid-scan hydrodynamic voltammetry and cyclic voltammetry of pharmaceuticals in flow injection analysis conditions.

An on-line rapid-scan electrochemical detector is described for HPLC and FIA systems. Its practical use in qualitative analysis is demonstrated for 19 drug substances. The detector can be operated to record convection/diffusion-controlled (S-shaped), or diffusion-controlled (peak-shaped) voltammograms. In the latter mode, on-line cyclic voltammetry measurements are possible. The cell can also be used as an amperometric detector for conventional, microbore and micro-LC methods. Detection limits are of the order of 10 pg (conventional and microbore HPLC), or at the sub-picogram level (micro-LC). For scanning work, drugs can be analysed at mg l-1 levels in an FIA setup.

Caffeic Acids