Correction for particle-wall interactions in the separation of colloids by flow field-flow fractionation.

In the characterization of materials by field-flow fractionation (FFF), the experienced analyst understands the importance of incorporating additives in the carrier liquid that minimize or eliminate interactions between the analyte and accumulation wall, particularly in aqueous systems. However, as FFF is applied to more difficult samples, such as those with high surface energies, it is increasingly difficult to find additives that completely eliminate particle-wall interactions. Furthermore, the analyst may wish to use specific conditions that preserve the high surface energy of particles, to study their interaction with other materials through their behavior in the FFF channel. With this in mind, Williams and co-workers developed a model that quantifies the effect of particle-wall interactions in FFF using an empirically determined interaction parameter. In this work, the model is evaluated for the application of flow FFF in carrier liquids of low ionic strength, where particle-wall interactions are magnified. The retention of particles ranging in size from 64 to 1000 nm is measured using a wide range of field strengths and retention levels. The model is found to be generally valid over the entire range, except for minor discrepancies at lower levels of retention. Although retention levels are dramatically affected by particle-wall interactions, the point of steric inversion (500 nm), where the size-based elution order reverses, is not affected. When particle-wall interactions are not accounted for, they lead to a bias in particle sizes calculated from standard retention theory of up to 70%. The model can also be used to refine the measurement of channel thickness, which is important for the accurate conversion of retention parameters to particle sizes. In this work, for example, errors in channel thickness led to systematic errors on the order of 10% in particle diameter.

Algorithms↗

The use of sedimentation field flow fractionation and photon correlation spectroscopy in the characterization of casein micelles.

Sedimentation Field Flow Fractionation (SdFFF) was combined with Photon Correlation Spectroscopy (PCS), to characterize changes in the structure of the colloidal particles of reconstituted skim milk of diameter >50 nm (aggregates of casein and calcium phosphate known as casein micelles) with the changes in partitioning (with the addition of salt) of calcium (Ca), inorganic phosphate (Pi) and casein between the serum and colloidal phases of the milk. The number weighted particle size distributions are determined. These are well represented by a log-normal distribution. Methods are presented for estimating the relative contributions of scattering and absorbance to the SdFFF detector signal and for taking both into account when analysing SdFFF data. The values found for the effective density of the casein micelles were in good agreement with the literature and ranged from (1.06-1.08 g cm(-3)) according to the composition of micelles. The changes in the scattering intensity as determined by PCS correlated with the changes in the particle composition. Although the concentrations of colloidal calcium phosphate (CCP) (1.1-3.5 g/kg milk) and micellar casein (18.1-27.2 g/kg milk) varied considerably only small changes in the size distribution of particles >50 nm diameter were observed except for milk to which 30 mmol Pi+10 mmol Ca/kg milk had been added where the particle size distribution shows a swelling of the particles consistent with a lower than expected value for the particle density. These observations suggest that the micelles have the ability to both lose (depleted micelles) and accommodate (enriched micelles) more casein, calcium and inorganic phosphate in their interior, thus confirming the model of the micelles which postulates an open structure allowing freedom of movement of casein and small ions.

Animals↗

Field and flow programming in frit-inlet asymmetrical flow field-flow fractionation.

The separation of wide molecular mass (Mr) ranges of macromolecules using frit inlet asymmetrical flow field-flow fractionation (FI-AFlFFF) has been improved by implementing a combination of field and flow programming. In this first implementation, field strength (governed by the cross flow-rate through the membrane-covered accumulation wall) is decreased with time to obtain faster elution and improved detection of the more strongly retained (high Mr) materials. The channel outlet flow-rate is optionally held constant, increased, or decreased with time. With circulation of the flow exiting the accumulation wall to the inlet frit, the dual programming of cross flow and channel outlet flow could be implemented using just two pumps. With this flow configuration, the channel outlet flow-rate is always equal to the channel inlet flow-rate, and these may be programmed independently of the cross flow-rate through the membrane. FI-AFlFFF retains its operational advantage over conventional asymmetrical flow FFF (AFlFFF). Unlike conventional AFlFFF, FI-AFlFFF does not require time consuming, and experimentally inconvenient, sample focusing and relaxation steps involving valve switching and interruption of sample migration. The advantages of employing dual programming with FI-AFlFFF are demonstrated for sets of polystyrene sulfonate standards in the molecular mass range of 4 to 1000 kDa. It is shown that programmed FI-AFlFFF successfully expands the dynamic separation range of molecular mass.

Chromatography, High Pressure Liquid↗

Geometric scaling effects in electrical field flow fractionation. 2. Experimental results.

Geometric scaling of microelectrical field flow fractionation (micro-EFFF) systems is investigated experimentally and compared to theory and to macroscale EFFF systems. Experimental results are presented to demonstrate that the miniaturized system operates according to the scaling theory associated with the system. Demonstrated improvements in the channels include increased retention and resolution and decreased peak broadening, electrical time constants, relaxation time, power consumption, and sample size. Additionally, scaling effects related to the compression of separation zones in the miniaturized EFFF systems are discussed.

Electrodes↗

Dielectrophoresis field flow fractionation of single-walled carbon nanotubes.

We report a study on Dielectrophoresis Field Flow Fractionation of Single-Wall Carbon Nanotubes (SWNTs). SWNTs, individually suspended in 1% SDBS solution, were separated by type when they passed a dielectrophoresis field flow fractionation device where 1 MHz AC voltage was supplied and the field strength was well below 1 V per mum. Furthermore, we uniquely observed enrichment of semiconductive SWNTs based on their band gap. In addition to Raman spectrum, UV-vis absorption and NIR fluorescence spectra were used for solution samples for characterization.

Electrophoresis, Microchip↗

Study of continuous two-dimensional thermal field-flow fractionation of polymers.

Two-dimensional thermal field-flow fractionation (2D-ThFFF) is a new instrumental technique devised for continuous fractionation of soluble macromolecules and particles. The sample mixture is introduced into a disc-shaped channel and the separated sample components are collected continuously from the channel outlets. The method is based on a two-dimensional fractionation mechanism with radial and tangential flow components in the channel. The effects of flow components and thermal gradient on the fractionation were studied in the separation of polystyrene samples of different molecular masses using cyclohexane or a binary solvent consisting of 25% ethylbenzene and 75% cyclohexane as carrier. The continuous separation of polystyrene samples was improved with increasing thermal gradient and with the use of slow radial and tangential flow rates. The technique can be applied to preparative continuous separation of macromolecules.

Journal Article↗

Analysis of drug/plasma protein interactions by means of asymmetrical flow field-flow fractionation.

PURPOSE: The applicability of Asymmetrical Flow Field-Flow Fractionation (Asymmetrical Flow FFF) as an alternative tool to examine the distribution of a lipophilic drug (N-Benzoyl-staurosporine) within human plasma protein fractions was investigated with respect to high separation speed and loss of material on surfaces due to adsorption. METHODS: Field-Flow Fractionation is defined as a group of pseudochromatographic separation methods, where compounds are separated under the influence of an externally applied force based on differences in their physicochemical properties. This method was used to separate human plasma in its protein fractions. The drug distribution in the fractions was investigated by monitoring the fractionated eluate for drug content by fluorescence spectroscopy. RESULTS: Human plasma was separated into human serum albumin (HSA), high density lipoprotein (HDL), alpha 2-macroglobulin and low density lipoprotein (LDL) fractions in less than ten minutes. Calibration of the system and identification of the individual fractions was performed using commercially available protein reference standards. The influence of membrane type and carrier solution composition on the absolute recovery of N-Benzoyl-staurosporine and fluorescein-isothiocyanate-albumin (FITC-albumin) was found to be quite significant. Both factors were optimized during the course of the investigations. N-Benzoyl-staurosporine was found to be enriched in the fraction containing HSA. CONCLUSIONS: If experimental conditions are thoroughly selected and controlled to suppress drug and plasma protein adsorption at the separation membrane, Asymmetrical Flow FFF shows high recoveries and fast separation of human plasma proteins, and can be a reliable tool to characterize drug/plasma protein interactions. For analytical purposes it has the potential to rival established technologies like ultracentrifugation in terms of ease-of-use, precision, and separation time.

Adsorption↗

Biocompatible channels for field-flow fractionation of biological samples: correlation between surface composition and operating performance.

Biocompatible methods capable of rapid purification and fractionation of analytes from complex natural matrices are increasingly in demand, particularly at the forefront of biotechnological applications. Field-flow fractionation is a separation technique suitable for nano-sized and micro-sized analytes among which bioanalytes are an important family. The objective of this preliminary study is to start a more general approach to field-flow fractionation for bio-samples by investigation of the correlation between channel surface composition and biosample adhesion. For the first time we report on the use of X-ray photoelectron spectroscopy (XPS) to study the surface properties of channels of known performance. By XPS, a polar hydrophobic environment was found on PVC material commonly used as accumulation wall in gravitational field-flow fractionation (GrFFF), which explains the low recovery obtained when GrFFF was used to fractionate a biological sample such as Staphylococcus aureus. An increase in separation performance was obtained first by conditioning the accumulation wall with bovine serum albumin and then by using the ion-beam sputtering technique to cover the GrFFF channel surface with a controlled inert film. XPS analysis was also employed to determine the composition of membranes used in hollow-fiber flow field-flow fractionation (HF FlFFF). The results obtained revealed homogeneous composition along the HF FlFFF channel both before and after its use for fractionation of an intact protein such as ferritin.

Animals↗

A one-dimensional transient model of electrical field flow fractionation.

A well-developed classical theory is available for constant-voltage electrical field flow fractionation (EFFF). Recent experimental research, however, has demonstrated that pulsed fields may enhance retention in some cases. A generalized mathematical approach is presented for the prediction of retention ratios for any field type, pulsed or constant. The methodology is applied and demonstrated for a square wave protocol. Complex concentration profiles arise wherein particles are focused either towards the walls or into the channel center. The computational results indicate that pulsation can either increase retention time or decrease retention time by manipulating the effective electric field and suggest that separation resolution may also be improved.

Electricity↗

Micro-thermal focusing field-flow fractionation.

Focusing mechanism was effectively exploited to separate large (micrometer-size) particles by using new micro-thermal field-flow fractionation (micro-TFFF). It has been shown that the retention order of micrometer-size particles at high field strength can be explained by the mechanism of steric exclusion only at lowest flow rates of the carrier liquid. A simplistic, purely mechanical model of steric exclusion is not accurate to describe the retention at higher flow rates where the focusing phenomenon appears. Despite the fact that the thickness of the channel for micro-FFF cannot be reduced without taking into account a possible deterioration of the separation due to the contribution of "steric exclusion" mechanism, this paper demonstrates, in agreement with our previous results, that if the operational conditions were conveniently chosen, namely a low flow rate, a reasonable fit of the experimental retention data with the theory of steric exclusion mechanism in FFF was found and the separation of micron-size particles can be accomplished. However, high selectivity and resolution and high-speed separation were achieved if the focusing effect has clearly dominated the FFF mechanism. As a result, it seems that the micro-TFFF is the most universal technique which can be applied for the separation of the synthetic and natural macromolecules within an extended range of molar masses up to ultra-high molar masses and for the particles of various chemical nature and origin in a nano-size range as well as for large (micrometers) particles. Until nowadays, only sedimentation and flow field-flow fractionation techniques in so called "steric" modes were applied for the separations of large size particles. This application of micro-TFFF in focusing mode for the separation of large size particles is the first one described in the literature.

Algorithms↗

Field flow fractionation in biomedical analysis.

Samples of biomedical interest which have been analysed by field-flow fractionation techniques are surveyed. The list begins with whole cells and microorganisms, going through viruses, nucleic acids, cell fragments and organelles, down to proteins and their aggregates. The principles of separation in the normal and steric mode of retention are illustrated, and instrumentation and techniques are described. The review concentrates mainly on the two systems of choice for biomedical applications: sedimentation and flow field-flow fractionation.

Cell Fractionation↗

Gravitational field-flow fractionation for the characterisation of active dry wine yeast.

Gravitational field-flow fractionation (GrFFF) is applied to the fractionation of active dry wine yeast. An experimental approach to the analysis of the effects that field variation by changing mobile phase composition and flow-rate have on the fractionation process of standard particles (polystyrene) was first developed to further obtain effective fractionation of wine yeast by GrFFF. Scanning electron microscopy and Coulter counter particle size measurements were used to monitor the fractionation extent and capabilities of GrFFF to describe the distribution of yeast cells populations.

Chemical Fractionation↗

Accuracy estimation of multiangle light scattering detectors utilized for polydisperse particle characterization with field-flow fractionation techniques: a simulation study.

The coupling of field-flow fractionation (FFF) and multiangle light scattering (MAIS) detectors is complementary in that the MALS system allows particle characterization when a narrow dispersity particle population is present in the detector. The fractionation process provides this narrow dispersity. Utilizing discrete particle simulations of FFF and optical calculations based on both the Mie theory of particle scattering and Rayleigh-Gans-Debye (RGD) scattering theory, the extent of polydispersity that can be tolerated for accurate particle quantitation is explored. It is found that flow, electrical, and sedimentation FFF provide adequate separation for accurate particle quantitation by MALS. The Mie theory is more accurate than the RGD theory, which is known to deviate at higher particle size. Low error in the measurement of mean diameters is found when only the particle diameter is of interest. It is shown that the reconstruction of the particle size distribution from time slice data is distorted due to errors in concentration, which result from finite polydispersity and other effects. A number of procedures are evaluated in restoring the size distribution to higher accuracy. None of these procedures is deemed of general purpose and none of these is reliable. The best results are obtained when fractionation is conducted under the minimal possible outlet polydispersity and when steric effects are minimized. In addition, best results are had for inherently narrow dispersity colloidal materials.

Journal Article↗

Modeling of sample dynamics in rectangular asymmetrical flow field-flow fractionation channels

We model the evolution of the concentration field of macromolecules in a rectangular asymmetrical flow field-flow fractionation channel using center manifold techniques. The deviation of the primary flow from a parabolic profile influences the concentration field and this is investigated to complement previously known results. The long-term evolution of the components of the sample is shown to be well described by a one-dimensional advection-diffusion equation. The coefficients of this equation are determined by the rigorous analysis of the complete set of equations governing the two-dimensional fluid flow. This model gives quantitative predictions of the elution time of the samples, the width of the concentration pulse, and the resolution of the apparatus. The influence of initial sample width and effects of the secondary relaxation from focusing to elution conditions are discussed. Reported theoretical predictions are in agreement with experimental results published previously.

Journal Article↗

Field-flow fractionation: analysis of macromolecular, colloidal, and particulate materials.

Field-flow fractionation (FFF) is a family of flexible elution techniques capable of simultaneous separation and measurement. Its sample domain extends across a broad macromolecular-colloidal-particulate continuum from about 1 nanometer to more than 100 micrometers and incorporates both simple and complex macromaterials of biological, biomedical, industrial, and environmental relevance. Complex materials are separated into components to simplify measurement. Component properties measurable by FFF include mass, size, density, charge, diffusivity, and thickness of adsorbed layers. When characterization by these properties is inadequate, other measurement tools can be readily coupled to FFF, either off-line or on-line, by virtue of its flow-elution operation. This article describes the principles and major subtechniques of the FFF family along with application of its measurement and separative capabilities.

Chemical Fractionation↗

Determination of thermal diffusion coefficients using thermal field-flow fractionation and Mark-Houwink constants.

In this paper, a new approach for determination of thermal diffusion coefficient D(T) values using thermal field-flow fractionation retention data and Mark-Houwink constants is reported. The method utilizes the availability of Mark-Houwink constants from the literature together with thermal field-flow fractionation retention data to calculate D(T) values for both narrowly and broadly dispersed polymeric samples. The proposed method was tested with thermal field-flow fractionation data from a number of published papers. In general, D(T) results obtained from the new approach agree well with those reported from the literature. Since Mark-Houwink constants have been extensively tabulated, the new method can be used to generate a broad database of D(T) values for use in the characterization of polymers and in studies of the thermal diffusion phenomenon.

Journal Article↗

Separation of human and animal cells by steric field-flow fractionation.

In this work, the feasibility of separating and characterizing cell populations by steric field-flow fractionation (steric FFF) is demonstrated by application to fixed human and avian red cells, fresh blood from several species, and viable HeLa cells. The basis for this work is established by means of a discussion of the role of steric FFF in the broad family of field-flow fractionation techniques. The behavior of steric FFF is then characterized by application to standard polystyrene latex beads and to fixed red blood cells. Studies of these standards and of the other cells noted under various conditions of field strength and flow velocity are used to improve the separation conditions and approach optimization. It is shown that the fixed human and avian red cells can be separated in a time of less than 15 min. In addition, it is shown that HeLa cells maintain their viability after passage through the separation channel.

Animals↗

Hydrodynamic relaxation using stopless flow injection in split inlet sedimentation field-flow fractionation.

In this paper relaxation effects in both the normal and steric operating modes of sedimentation field-flow fractionation are examined by using three different injection procedures: stop flow, stopless flow, and a new stopless flow procedure employing an inlet splitter. In the usual operation of field-flow fractionation (FFF), a stop procedure is used in which the channel flow is halted for an adequate period of time after injection for sample relaxation (in which the sample particles approach equillibrium near one wall) before the resumption of channel flow. If the channel flow is not stopped (stopless flow procedure), the elution profile is shifted and distorted due to the downstream migration of the particles during the relaxation process. To avoid peak distortion while retaining the advantages of the stopless flow procedure, a physical splitter at the channel inlet divides the entering flow stream into two substreams; sample is injected into only one of these. In this way a rapid (although not complete) hydrodynamic relaxation is realized. This stopless split flow injection procedure is compared to ordinary stop and stopless flow procedures using both submicrometer (normal FFF) and supramicrometer (steric FFF) polystyrene latex particles. It is found that much of the distortion normally accompanying stopless flow injection is eliminated by this new procedure. However, further optimization is needed to match the high resolution of the stop flow method.

Chemical Fractionation↗