PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “LARYNGOSCOPY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Predicting difficult laryngoscopy for tracheal intubation: an approach to airway assessment.

Tracheal intubation by direct laryngoscopy is an essential skill for physicians working in the operating room, emergency room or intensive care unit settings. While tracheal intubation can usually be accomplished with ease by direct laryngoscopy, it is sometimes difficult or impossible because of coexisting disease or abnormal physical features. When recognized before attempts at tracheal intubation, virtually all difficult airways can be secured by the selected use of specialized tracheal intubation techniques, although many of these methods require special training, experience, assistance and equipment. When a difficult airway is unrecognized before attempts at intubation the results can be catastrophic because the personnel and equipment necessary for utilizing the specialized tracheal intubation techniques may not be immediately available and the patient's spontaneous respiratory efforts may have been eliminated by anesthetics or muscle relaxants. Thus, identifying patients who are likely to harbor an airway that cannot reliably be secured by simple direct laryngoscopy is an important skill for all acute or critical care physicians. There is an extensive research data base describing historical information, physical examination findings and radiographic features that are associated with the difficult airway. Reviewed collectively, one of the most important underlying concepts suggested by this body of research literature is that the difficult airway is a product of many anatomic and pathologic variables. A surprisingly wide variety of historical, physical examination and radiographic features associated with difficult direct laryngoscopy have been described. A rational approach to airway assessment, therefore, naturally includes a detailed history, a careful physical examination and inspection of relevant x-rays whenever time permits. As outlined in Table 5, there are specific questions to address that may warn the physician about possible airway difficulty. A number of airway assessment schemes based on physical examination findings have been proposed and tested. These schemes vary in their complexity and their clinical convenience. The simpler schemes fail to address the multifactorial nature of the problem, while the more complex systems are clinically impractical. Schemes combining the distance of the thyromental space and the visibility of the oropharyngeal structures, such as that proposed by Frerk, are perhaps the most practical and reliable of the methods proposed to date. Clearly, no one scheme is ideal. At present, preintubation airway evaluation remains a poorly quantified gestalt estimate of the chances for difficulty based on a complex juxtaposition of historical information and physical findings.(ABSTRACT TRUNCATED AT 400 WORDS)

Humans↗

[Blunt trauma of the larynx: comparative assessment of computerized tomography, conventional radiology, and laryngoscopy].

We report on the retrospective analysis of a series of 11 patients with blunt laryngeal injuries examined with Computed Tomography (CT), conventional radiology and laryngoscopy, to compare the diagnostic yield of each technique. Conventional frontal and lateral radiographs showed subcutaneous emphysema in 5 patients, with soft tissue swelling in 4, and thus failed to assess the degree of damage adequately. Cross-section CT showed cartilaginous injuries in 5 patients and adjacent soft tissue changes in 9, thus allowing rapid and accurate assessment of airway damage even in emergency. Laryngoscopy showed laryngeal mucosal tears in 3 patients, with decreased motion of the left true vocal cord in one patient and of both true vocal cords in another, associated with the upward dislocation of arytenoid cartilage. Moreover, laryngoscopy showed a mucosal tear in the hypopharynx in one patient. Comparative CT and laryngoscopy assessment showed, in two cases, that CT can demonstrate even minimal peripharyngeal and perilaryngeal air images which are suggestive of posttraumatic mucosal tears. Thus, CT appears the most valuable diagnostic tool to study the injured larynx.

Adolescent↗

A new device for measuring and recording the forces applied during laryngoscopy.

In characterising the forces exerted during laryngoscopy it is accepted that the significant force component is that which is parallel to the axis of the laryngoscope handle. This paper describes a new method of evaluating the forces exerted at laryngoscopy. A laryngoscope handle has been redesigned, incorporating a force-displacement transducer on the handle at the end opposite to where the blade is attached. The device is designed specifically to sense the axial component of force. The blade attachment block has been detached from the sleeve and connected to a steel shaft which forms the new battery compartment. This allows the axial force exerted at the blade during laryngoscopy to be transmitted along this shaft to the sensing transducer. Linear ball bearings have been introduced between the new shaft and the handle sleeve (outer casing). The rolling friction has been reduced to less than 0.1% by diamond-lapping the precision ground surface-hardened rod to produce a mirror finish. Thus, the force transmitted to the transducer is essentially constant regardless of where the load is applied along the blade. The output from the system is directly downloaded to a laptop computer and the data analysed almost instantaneously to determine the duration of laryngoscopy, the peak forces applied, the mean force with its standard deviation and graphic display of the data. Provision has been made for data entry checks, recording patient details and study data, and creating a data base for the storage and retrieval of the study details.

Adult↗

Laryngoscopy using the McCoy laryngoscope after application of a cervical collar.

A rigid cervical collar was applied to 102 patients under general anaesthesia. Laryngoscopy was performed using a McCoy laryngoscope blade (size 3) initially in the standard Macintosh configuration followed by activation of the distal hinged tip. The two views obtained at laryngoscopy were graded according to standard guidelines. In 46/102 (45.1%) patients the laryngoscopic view was improved by one or more grades. In 10/102 (9.8%) the view was improved by two grades. Difficult laryngoscopy (grade 3 or 4) was encountered in 26/102 patients using the McCoy laryngoscope in the unactivated position (Macintosh configuration). Of these 26 patients, 24 (92.3%) had glottic structures identified (grade 1 or 2) when the distal tip of the laryngoscope blade was activated (p < 0.001). The McCoy laryngoscope significantly improves the view at laryngoscopy in the patient whose neck is immobilised in a rigid cervical collar.

Adolescent↗

A comparison of the forces exerted during laryngoscopy. The Macintosh versus the McCoy blade.

The forces exerted at laryngoscopy with the McCoy and Macintosh blades have been compared in 40 patients. The variables measured were the duration of laryngoscopy, the three maximally-applied forces and the mean force. The mean (SD) forces recorded were 18.9 (7.82) and 10.1 (5.33) N, respectively, with the Macintosh and the McCoy blades (p < 0.001) with a similar duration of laryngoscopy. There was a significant positive correlation between the mean force and patients' weight, height and body mass index for the Macintosh blade but only for weight and height for the McCoy blade. It is concluded that the use of the McCoy blade results in significantly less force being applied during laryngoscopy. This may be the reason for the reduction in the stress response reported previously with the use of the McCoy blade.

Adolescent↗

Efficacy of fentanyl and esmolol in the prevention of haemodynamic response to laryngoscopy and endotracheal intubation.

OBJECTIVE: To compare the effectiveness of single bolus dose of esmolol or fentanyl in attenuating the haemodynamic responses during laryngoscopy and endotracheal intubation. DESIGN: Randomized, placebo controlled, double blind study. PLACE AND DURATION OF STUDY: Department of Anaesthesia and Surgical Intensive Care Unit, Civil Hospital, Karachi, from December 1998 to November 1999. PATIENTS AND METHODS: Sixty adult ASA-I and ASA-II patients undergoing elective surgery were included in the study. The patients were randomly divided into three groups i.e., A, B and C. Heart rate, systolic, diastolic and mean blood pressures were recorded as 0= baseline and after administration of study drug, laryngoscopy and endotracheal intubation and 10 minutes thereafter. Study agent was injected 30 seconds before the induction of anaesthesia. Group 'A' (control) received 10 ml saline, group 'B' and group 'C' received fentanyl 2 mg/kg and esmolol 2 mg/kg respectively diluted to make a total volume of 10 ml in normal saline. RESULTS: Readings of heart rate, systolic, diastolic and mean arterial pressures were compared with baseline and among each group. The rise in heart rate was minimal in esmolol group and was statistically significant. Following intubation, blood pressure was increased in all groups but was least in group C. CONCLUSION: Bolus injection of fentanyl 2 mg/kg 2 minutes prior to laryngoscopy and intubation failed to protect against elevation of both the heart rate and systolic blood pressure, whereas esmolol at 2 mg/kg provided consistent and reliable protection against the increase of heart rate but not arterial blood pressure.

Adrenergic beta-Antagonists↗

Bronchoscopy and laryngoscopy findings as indications for tracheotomy in the burned child.

OBJECTIVE: To determine possible indications for tracheotomy in the burned child based on bronchoscopic and laryngoscopic findings. DESIGN AND SETTING: A retrospective case study of all patients admitted to a tertiary children's burn center. PARTICIPANTS: All children admitted with burn inhalation injury between 1990 and 1995 (n = 211). INTERVENTION: All patients underwent laryngoscopy and bronchoscopy and 19 underwent tracheotomy, with 5 tracheotomy tubes placed emergently. MAIN OUTCOME MEASURES: Observations during laryngoscopy and bronchoscopy included erythema, edema, carbonaceous material, ulcerations, and bronchial mucous casts. The supraglottis, glottis, and subglottis were analyzed separately, when possible. Any sepsis resulting from tracheotomy was determined. Complications, such as glottic webs, subglottic stenosis, and tracheomalacia, were noted. RESULTS: Indications for tracheotomy included 6 for airway obstruction, 6 for prolonged intubation, 6 for pulmonary cleansing, and 1 for endotracheal tube complications (subglottic stenosis). When examined by bronchoscopy and laryngoscopy, 17 of 19 children had significant airway edema, 10 had carbonaceous material in the airway, and 3 had ulcerations in the airway. CONCLUSIONS: Tracheotomy is indicated in the burned child when significant airway edema is present. Failure to place a tracheotomy tube in these cases leads to a high incidence of immediate tracheotomies (26%). There was no evidence of clinically significant infection attributable to tracheotomy. The number of airway complications due to tracheotomy was no higher than from endotracheal intubation.

Airway Obstruction↗

Efficacy of fiberoptic laryngoscopy in the diagnosis of inhalation injuries.

BACKGROUND: A significant proportion of burn patients with inhalation injuries incur difficulties with airway protection, dysphagia, and aspiration. In assessing the need for intubation in burn patients, the efficacy of fiberoptic laryngoscopy was compared with clinical findings and the findings of diagnostic tests, such as arterial blood gas analysis, measurement of carboxyhemoglobin levels, pulmonary function tests, and radiography of the lateral aspect of the neck. OBJECTIVE: To determine if these patients were at risk for aspiration or dysphagia, barium-enhanced fluoroscopic swallowing studies were performed. DESIGN: Prospective study. SETTINGS: Burn intensive care unit in an academic tertiary referral center. MAIN OUTCOME MEASURES: Need for endotracheal intubation and potential for aspiration. RESULTS: Six (55%) of 11 patients had clinical findings and symptoms that indicated, under traditional criteria, endotracheal intubation for airway protection. Visualization of the upper airway with fiberoptic laryngoscopy obviated the need for endotracheal intubation in all 11 patients. These patients also failed to evidence an increased risk of aspiration or other swallowing dysfunction. CONCLUSIONS: In comparison with other diagnostic criteria, fiberoptic laryngoscopy allows differentiation of those patients with inhalation injuries who, while at risk for upper airway obstruction, do not require intubation. These patients may be safely observed in a monitored setting with serial fiberoptic examinations, thus avoiding the possible complications associated with intubation of an airway with a compromised mucosalized surface. In these patients, swallowing abnormalities do not manifest.

Adult↗

Circulatory responses to laryngoscopy: the comparative effects of placebo, fentanyl and esmolol.

The circulatory response to a 30-second laryngoscopy followed by orotracheal intubation was recorded in 60 patients of ASA physical status III or IV undergoing a variety of non-cardiac surgical procedures. Patients were randomly allocated to either the placebo, esmolol (500 micrograms.kg-1.min-1 X 6 minutes, followed by 300 micrograms.kg-1.min-1 X 9 minutes), or fentanyl (0.8 microgram.kg-1.min-1 X 10 minutes) group, and the observer was blinded to the infusion administered. Esmolol blunted the heart rate (HR) response, while fentanyl decreased it below the baseline and maintained it there, in spite of laryngoscopy. Similarly, fentanyl decreased the systolic (SBP), mean (MBP) and diastolic blood pressures (DBP) significantly below the baseline, while these pressures were either retained at or elevated slightly above control in the esmolol group. In these doses, the HR response to laryngoscopy was more effectively blocked by fentanyl, while esmolol better retained perfusion pressure. There were no complications or ischaemic electrocardiographic changes in any patient.

Adrenergic beta-Antagonists↗

Nicardipine and verapamil attenuate the pressor response to laryngoscopy and intubation.

In a prospective, double-blind study, we compared the efficacy of iv nicardipine hydrochloride and verapamil hydrochloride in attenuating the cardiovascular responses to laryngoscopy and tracheal intubation, in 45 patients undergoing elective surgery with general anaesthesia. Patients were allocated randomly to one of three groups of 15 patients. Patients in Group I received saline while those in Groups II and III received nicardipine hydrochloride, 0.03 mg.kg-1 or verapamil hydrochloride, 0.1 mg.kg-1 iv three minutes before laryngoscopy and intubation. Patients in Group I showed the greatest increase in SBP 25.4 +/- 2.2 2.2 mmHg and HR 35.7 +/- 3.8 beats.min-1 at one minute after intubation (P < 0.001), and these changes persisted throughout the study period albeit with decreasing magnitude. After drug administration, patients in Groups II and III demonstrated increases in HR of 26 +/- 2.4 and 15.1 +/- 2.2 beats.min-1 and decreases in SBP of 24.8 +/- 2.0 and 18.8 +/- 2.4 mmHg respectively (P < 0.001). It is concluded that nicardipine and verapamil are effective in attenuating pressor responses to laryngoscopy and intubation but did not control the tachycardia.

Adult↗

Indirect autofluorescence laryngoscopy in the diagnosis of laryngeal cancer and its precursor lesions.

Direct autofluorescence endoscopy of the larynx has proven to facilitate the detection and delineation of precancerous lesions, carcinoma in situ and cancer. The aim of the present study was to evaluate the diagnostic potential and limitations of this imaging technique applied during indirect laryngoscopy. In a prospective study, 116 patients with suspected precancerous or cancerous lesions were investigated preoperatively by indirect autofluorescence laryngoscopy. Autofluorescence was induced by filtered blue light (375-440 nm) of a xenon short-arc lamp and processed by a CCD camera system (D-light-AF System, Storz, Tuttlingen, Germany). Autofluorescence images were immediately assessed for diagnosis, compared to the direct autofluorescence picture obtained during microlaryngoscopy and compared to pathohistological findings. Comparable to direct autofluorescence images, normal laryngeal mucosa showed a typical green fluorescence signal. Moderate and high epithelial dysplasia, carcinoma in situ and cancer displayed a diminished green fluorescence. False negative results were related to extreme hyperkeratosis. False positive cases showed mild dysplasia with inflammatory reactions or scarring. In 103 cases (89%), we found concordant results. According to our results, the presented technique seems to be a promising diagnostic tool for the early detection of laryngeal cancer and its precursor lesions during indirect laryngoscopy. Scarring, marked hyperkeratosis and inflammation can limit the predictive value of the method.

Carcinoma in Situ↗

Clinical competence in the performance of fiberoptic laryngoscopy and endotracheal intubation: a study of resident instruction.

Anesthesiologists must be competent in the technique of fiberoptic laryngoscopy and intubation in airway management. The goal of this study was to test the hypothesis that an acceptable level of technical expertise in fiberoptic laryngoscopy and intubation may be acquired within 10 intubations while maintaining patient safety. The learning objectives were an intubation time of 2 minutes or less and greater than 90% success on the first intubation attempt. Ninety-one ASA physical status I-II patients with normal laryngeal anatomy had general anesthesia and were intubated orally with an Olympus LF-1 fiberoptic scope; the mean (+/- SD) time for intubation was 1.92 +/- 1.45 minutes. Four residents with no prior experience with fiberoptic laryngoscopy intubated at least 15 patients each. A learning curve was generated using logarithmic analysis of the mean (+/- SD) time for intubation of patients 1 to 15 for all residents combined. The curve showed that the mean (+/- SD) intubation time decreased from 4.00 +/- 2.91 to 1.53 +/- 0.76 minutes within the first 10 intubations. After the tenth intubation, the mean time was 1.53 minutes and the percent success on the first attempt at intubation was greater than 95%. There were no clinically important changes in O2 saturation, mean arterial pressure (MAP), or heart rate (HR) as a consequence of fiberoptic intubation. The results suggest that an acceptable level of technical expertise in fiberoptic intubation can be obtained (as defined by the learning objectives) by the tenth intubation, and patient safety is maintained.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

The effectiveness of oral clonidine as a sedative/anxiolytic and as a drug to blunt the hemodynamic responses to laryngoscopy.

STUDY OBJECTIVE: To determine the effects of oral clonidine premedication on sedative, anxiolytic, and hemodynamic responses during the immediate preoperative period, laryngoscopy/intubation, and postanesthetic recovery. DESIGN: Randomized double-blind assignment to one of four treatment groups (clonidine 0.1 mg, clonidine 0.2 mg, triazolam 0.25 mg, or placebo); n = 10 per group. SETTING: Inpatient surgery in a university-staffed tertiary center. PATIENTS: Forty ASA physical status I and II adults of both sexes scheduled for a variety of procedures requiring general anesthesia. INTERVENTIONS: Anxiety and sedation scored on ordinal scale at time of treatment and 90 minutes later, just prior to anesthetic induction. Standardized induction protocol with automated hemodynamic monitoring at 1-minute intervals and a 45-second laryngoscopy to ensure a vigorous stress response. MEASUREMENTS AND MAIN RESULTS: Triazolam and both doses of clonidine increased sedation at 90 minutes both absolutely and compared with a placebo. Clonidine 0.2 mg decreased anxiety absolutely at 90 minutes but no more than a placebo. Clonidine 0.2 mg decreased systolic, mean, and diastolic blood pressures (BPs) but not heart rate (HR) at 90 minutes. Clonidine 0.2 mg also blunted the increase in systolic blood pressure (SP) [but not in diastolic blood pressure (DP) or HR] that accompanied laryngoscopy. There were no treatment differences in postanesthetic hemodynamics or duration of recovery. CONCLUSIONS: Oral clonidine 0.2 mg was effective in reducing the level of behavioral and hemodynamic responses preoperatively and in blunting systolic hypertension produced by prolonged laryngoscopy.

Adult↗

Using the laryngeal indices caliper to predict difficulty of laryngoscopy with a Macintosh #3 laryngoscope.

STUDY OBJECTIVE: (1) To evaluate a device of the authors' design, the laryngeal indices caliper, which quantitates the position of the anterior edges of the larynx relative to the upper teeth and the external auditory canals; (2) to determine how relative laryngeal position affects ease of direct laryngoscopy with a Macintosh #3 laryngoscope. DESIGN: Randomized, double-blind study. SETTING: Inpatient surgery center at a university medical center. PATIENTS: 101 renal lithotripter patients. INTERVENTIONS: Patients were measured with the laryngeal indices caliper prior to induction of general endotracheal anesthesia. They were then given a sleep dose of thiopental sodium (4 mg/kg) and paralyzed with a bolus dose of succinylcholine (1 mg/kg). MEASUREMENTS AND MAIN RESULTS: Of the measurements taken or calculated, only laryngeal tilt (LT) showed a significant correlation with grade of difficulty of laryngoscopy. When the anterior surface of the thyroid cartilage was tilted more than 20 degrees anteriorly to a line perpendicular to the laryngeal indices line, the vocal cords could not be seen in 83% of the patients. CONCLUSIONS: (1) Laryngeal tilt is a good predictor of difficulty of laryngoscopy with a Macintosh #3 laryngoscope; (2) the laryngeal indices caliper is a simple pocket device to measure LT indirectly.

Double-Blind Method↗

Using the bubble inclinometer to measure laryngeal tilt and predict difficulty of laryngoscopy.

STUDY OBJECTIVE: To evaluate a simple device, the bubble inclinometer, to measure degrees of laryngeal tilt (LT) for predicting difficulty of direct laryngoscopy using a Macintosh #3 laryngoscope. DESIGN: Randomized, double-blind study. SETTING: Inpatient surgery center at a university medical center. PATIENTS: 50 renal lithotripter patients. INTERVENTIONS: Patients were measured with the bubble inclinometer and the laryngeal indices caliper. A sleep dose of thiopental sodium (4 mg/kg) and a muscle-relaxing dose of succinylcholine (1 mg/kg) were then given to each patient. MEASUREMENTS AND MAIN RESULTS: LT was measured by both methods (directly and indirectly). Difficulty of laryngoscopy was graded as follows: Grade 1 = all of vocal cords seen; Grade 2 = part of vocal cords seen; Grade 3 = no part of vocal cords seen. CONCLUSIONS: The bubble inclinometer accurately and reproducibly measures relative LT, and the anterior tilt of the larynx directly correlates with the ability to see the laryngeal opening during direct laryngoscopy with a Macintosh #3 laryngoscope.

Adult↗

Effects of intravenous lidocaine and/or esmolol on hemodynamic responses to laryngoscopy and intubation: a double-blind, controlled clinical trial.

STUDY OBJECTIVES: To evaluate the efficacy of intravenous lidocaine and two doses of esmolol for attenuating the cardiovascular responses to laryngoscopy and intubation, and to assess whether a combination of both drugs is more effective than either drug alone. DESIGN: Randomized, prospective, double-blind, placebo-controlled study. SETTING: University hospital. PATIENTS: 90 ASA status I and II normotensive women scheduled for elective gynecologic procedures with general anesthesia. INTERVENTIONS: Induction of anesthesia was standardized for all patients. The first group received lidocaine 1.5 mg/kg (Group LID); the second and third groups received esmolol 1 mg/kg and 2 mg/kg, respectively (Groups E1 and E2, respectively); the fourth group received lidocaine 1.5 mg/kg and esmolol 1 mg/kg (Group LID-E1); the fifth group received lidocaine 1.5 mg/kg and esmolol 2 mg/kg (Group LID-E2); the sixth group received saline as a placebo (Group PLAC). MEASUREMENTS AND MAIN RESULTS: Systolic blood pressure and heart rate (HR) were recorded before induction, before injection of the first test drug, immediately before laryngoscopy, and 1, 2, and 5 minutes following intubation. Duration of laryngoscopy was recorded. Only patients receiving placebo had increased HR values after intubation compared with baseline values (p < 0.05). The proportion of patients with a maximum HR exceeding 90 beats/min was significantly higher in the placebo group (8 of 15 patients) than in both esmolol groups (E1 2 of 15; E2 2 of 15) (p < 0.05). Systolic blood pressure values after tracheal intubation did not differ among groups except for those receiving the combinations of lidocaine and esmolol, and they had significantly lower blood pressure (BP) values compared with placebo (p < 0.05). CONCLUSIONS: Esmolol 1 to 2 mg/kg is reliably effective in attenuating HR response to tracheal intubation. Neither of the two doses of esmolol tested nor that of lidocaine affected the BP response. Only the combination of lidocaine and esmolol attenuated both HR and BP responses to tracheal intubation.

Adolescent↗

Assessment of the infant airway with videorecorded flexible laryngoscopy and the objective analysis of vocal fold abduction.

Accurate diagnosis of upper airway abnormalities by flexible laryngoscopy in infants is hampered by rapid laryngeal motion and lack of patient cooperation. This study evaluates the added role of videorecorded flexible laryngoscopy and the objective measurement of vocal fold abduction in improving the diagnosis of upper airway abnormalities in infants. Seventy-eight infants had videorecorded flexible laryngoscopy performed as part of their evaluation of a suspected airway disorder. These recordings were reviewed by three otolaryngologists for confirmation of the clinical diagnosis. From the video image, the maximum angle of vocal fold abduction was measured with image analysis software. Of 78 patients 40 had supraglottic or glottic abnormalities, 9 had nasal or nasopharyngeal obstruction, 9 had subglottic abnormalities (diagnosed subsequent to videolaryngoscopy), and 15 patients had normal findings on examination. Of those with laryngeal abnormalities, laryngomalacia was the most common diagnosis (23 of 78). Vocal fold paralysis was present in 4 patients. A separate group (9 of 78) of patients was identified as having symmetric bilateral limitation of vocal fold abduction. Laryngeal dyskinesia was diagnosed in these 9 patients. The mean values of maximal vocal fold abduction were as follows: (1) normals, 59.5 degrees; (2) laryngomalacia, 57.0 degrees; (3) paralysis, 26.6 degrees; and (4) incomplete abduction with laryngeal dyskinesia, 27.6 degrees. Videolaryngoscopy is a valuable tool for documentation, parent education, and analysis of infant laryngeal abnormalities. Repeat viewing of the video examination and frame-by-frame analysis improve the diagnostic accuracy. Using this approach, we have calculated the anterior glottic abduction angle in the normal and abnormal infant larynx. In addition, we have identified a group of infants with incomplete abduction of the vocal folds that appears to be different from that found in vocal cord paralysis.

Airway Obstruction↗

Airway management and direct laryngoscopy. A review and update.

Direct laryngoscopy is the direct visualization of the larynx while using a rigid laryngoscope to distract the structures of the upper airway. This article reviews the anatomy relevant to laryngoscopy and then presents a stepwise approach to the procedure. Alternative intubation techniques, positioning, laryngoscopy blades, and stylets are then covered. Pharmacologic adjuncts are discussed briefly as they relate to the difficult airway and incorporation into overall airway management.

Airway Obstruction↗