PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microelectrodes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Boron-doped diamond microelectrodes for use in capillary electrophoresis with electrochemical detection.

The fabrication and characterization of boron-doped diamond microelectrodes for use in electrochemical detection coupled with capillary electrophoresis (CE-EC) is discussed. The microelectrodes were prepared by coating thin films of polycrystalline diamond on electrochemically sharpened platinum wires (76-, 25-, and 10-microm diameter), using microwave-assisted chemical vapor deposition (CVD). The diamond-coated wires were attached to copper wires (current collectors), and several methods were explored to insulate the cylindrical portion of the electrode: nail polish, epoxy, polyimide, and polypropylene coatings. The microelectrodes were characterized by scanning electron microscopy, Raman spectroscopy, and cyclic voltammetry. They exhibited low and stable background currents and sigmoidally shaped voltammetric curves for Ru(NH3)6(3+/2+) and Fe(CN)6(3-/4-) at low scan rates. The microelectrodes formed with the large diameter Pt and sealed in polypropylene pipet tips were employed for end-column detection in CE. Evaluation of the CE-EC system and the electrode performance were accomplished using a 10 mM phosphate buffer, pH 6.0, run buffer, and a 30-cm-long fused-silica capillary (75-microm i.d.) with dopamine, catechol, and ascorbic acid serving as test analytes. The background current (approximately 100 pA) and noise (approximately 3 pA) were measured at different detection potentials and found to be very stable with time. Reproducible separation (elution time) and detection (peak current or area) of dopamine, catechol, and ascorbic acid were observed with response precisions of 4.1% or less. Calibration curves constructed from the peak area were linear over 4 orders of magnitude, up to a concentration between 0.1 and 1 mM. Mass limits of detection for dopamine and catechol were 1.7 and 2.6 fmol, respectively (S/N = 3). The separation efficiency was approximately 33,000, 56,000, and 98,000 plates/m for dopamine, catechol, and ascorbic acid, respectively. In addition, the separation and detection of 1- and 2-naphthol in 160 mM borate buffer, pH 9.2, was investigated. Separation of these two analytes was achieved with efficiencies of 118,000 and 126,000 plates/m, respectively.

Ascorbic Acid↗

Interdigitated Array microelectrode-based electrochemical impedance immunosensor for detection of Escherichia coli O157:H7.

A label-free electrochemical impedance immunosensor for rapid detection of Escherichia coli O157:H7 was developed by immobilizing anti-E. coli antibodies onto an indium-tin oxide interdigitated array (IDA) microelectrode. Based on the general electronic equivalent model of an electrochemical cell and the behavior of the IDA microelectrode, an equivalent circuit, consisting of an ohmic resistor of the electrolyte between two electrodes and a double layer capacitor, an electron-transfer resistor, and a Warburg impedance around each electrode, was introduced for interpretation of the impedance components of the IDA microelectrode system. The results showed that the immobilization of antibodies and the binding of E. coli cells to the IDA microelectrode surface increased the electron-transfer resistance, which was directly measured with electrochemical impedance spectroscopy in the presence of [Fe(CN)(6)](3-/4-) as a redox probe. The electron-transfer resistance was correlated with the concentration of E. coli cells in a range from 4.36 x 10(5) to 4.36 x 10(8) cfu/mL with the detection limit of 10(6) cfu/mL.

Antibodies, Bacterial↗

Scanning electrochemical microscopy with a band microelectrode: theory and application.

Scanning electrochemical microscopy (SECM) is described using a band microelectrode tip. Numerical calculations allow the determination of approach curves of an insulating or a conductive substrate, and the numerical analysis is compared to experimental curves. Natural convection provides a steady-state current at the band microelectrode at an infinite distance from the substrate, and the band tip may be used in the SECM configuration as easily as the tip of a disk. Owing to the millimetric dimension of the band microelectrode, the substrate has an influence on the current at much longer distances than with the disk. Finally, the advantage of SECM with a band microelectrode is observed with the fast electrochemical modification of a fluoropolymer surface.

Electrochemistry↗

In vitro continuous amperometry with a diamond microelectrode coupled with video microscopy for simultaneously monitoring endogenous norepinephrine and its effect on the contractile response of a rat mesenteric artery.

Continuous amperometry with a diamond microelectrode and video microscopy were used to record (in vitro) endogenous norepinephrine release simultaneously with the evoked contractile response of a mesenteric artery from a healthy Sprague Dawley rat. Norepinephrine (NE) is a vasoconstricting neurotransmitter released from sympathetic nerves that innervate the smooth muscle cell layers surrounding arteries and veins. Using these two techniques along with several drugs, the NE released at sympathetic neuroeffector junctions nearby the microelectrode was measured as an oxidation current. Key to the amperometric measurement was the use of a diamond microelectrode because of the response sensitivity, reproducibility, and stability it provided. NE release was elicited by electrical stimulation at frequencies between 1 and 60 Hz, with a maximum response seen at 20 Hz. Confirmation that the oxidation current was, in fact, associated with endogenous NE came from the results of several drugs. Tetrodotoxin (TTX, 0.3 microM), a voltage-dependent sodium channel antagonist that blocks nerve conduction, abolished both the oxidation current and the arterial constriction. The alpha(2)-adrenergic autoreceptor antagonist, yohimbine (1.0 microM), caused an increase in the oxidation current and the corresponding constriction. The addition of cocaine (10 microM), an antagonist that inhibits neuronal NE reuptake, caused both the oxidation current and the contractile response to increase. These results, combined with the fact that the hydrodynamic voltammetric E(1/2) for endogenous NE was identical to that for a standard solution, confirmed that the oxidation current was due to NE and that this compound caused, at least in part, the contractile response. The results demonstrate that continuous amperometric monitoring of NE with a diamond microelectrode and video imaging of vascular tone allow real time local measurement of the temporal relationship between nerve-stimulated NE release and arterial constriction.

Animals↗

Ceramic-based multisite microelectrodes for electrochemical recordings.

This paper describes the development and characterization of ceramic-based multisite arrays for electrochemical recordings in biological systems. These electrodes represent a parallel technology to the design of microelectrodes using silicon substrates. The ceramic substrates are stronger than silicon and are nonconducting, which makes them better suited for in vivo electrochemical measurements. The current designs are based on formation of four-site (50 x 50 microns with 200 microns spacing) electrodes on ceramic wafers using photolithography. The recording sites and connecting lines are made of Pt with a polyimide coating to insulate the connecting lines. The resulting electrodes are cut from the wafers producing a 1 cm length microelectrode that tapers to a approximately 2-5 microns tip. Electrochemical measures of dopamine and hydrogen peroxide support that the sensitivity, selectivity, and response characteristics of the electrodes exceed those of previously published silicon substrate-based microelectrodes. This is the first demonstration of microarrays formed from ceramic substrates, and the data presented support the hypothesis that these microelectrodes may be useful for a variety of neurochemical and electrophysiological applications. Preliminary in vivo electrochemical recordings are presented.

Animals↗

Enhancing electron transfer at a cytochrome c-immobilized microelectrode and macroelectrode.

The redox reaction of cytochrome c immobilized on the bare surfaces of microelectrodes and macroscopic electrodes (macroelectrodes) composed of different planes of highly oriented pyrolytic graphite has been investigated using cyclic voltammetry. The protein-immobilized microelectrodes were fabricated using a simple masking method. For both macroelectrodes and microelectrodes, the redox reaction of immobilized cytochrome c needs to be activated by increasing the electrochemical potential maximum of cyclic voltammetry to a high positive value. The redox currents of this protein-electrode system can be enhanced using two approaches. The oxidation and reduction currents of cytochrome c adsorbed on microelectrodes that are composed of the edge plane show an anomalous enhancement compared to those for macroelectrodes composed of the basal plane. The difference in the surface chemical properties of the two kinds of electrodes results in the current anomaly. The oxidation current of the macroelectrode can be selectively enhanced by decreasing the potential minimum.

Cytochromes c↗

Development of a phosphate ion-selective microelectrode and its use in studies of the enhanced biological phosphorus removal (EBPR) process.

In an enhanced biological phosphorus reactor (EBPR), most poly-phosphate accumulating microorganisms (PAOs) exist as microbial aggregates, or flocs. Information contributing to a better understanding of the internal structure and function of flocs can lead to improvements in the modeling, design and operation of EBPR systems in wastewater treatment. A phosphate ion-selective microelectrode has been developed and was used to measure the phosphate profiles in flocs. The microelectrode uses cobalt as the sensing material and shows very good selectivity towards orthophosphate ions (H2PO4(-), HPO4(2-) and PO4(3-)). The potentiometric response showed a linear relationship with the logarithm of phosphate concentrations, with a slope of 31.5 mV per decade change of concentration. The solution pH did not show a significant effect on the microelectrode performance within the pH range of 7.5 to approximately 8.0. The effect of ionic strength was also investigated. Measurements using this microelectrode were made on activated sludge floc samples taken from a municipal wastewater treatment plant.

Bioreactors↗

Cytosolic free calcium-ion concentration in cleaving embryonic cells of Oryzias latipes measured with calcium-selective microelectrodes.

Calcium-selective microelectrodes were used to measure the free calcium-ion concentration ([Ca2+]i) in early-cleaving embryonic cells of the golden medaka, Oryzias latipes, a fresh water teleost fish. Embryos could be dechorionated as early as the four-cell stage using a three-step technique consisting of removal of some yolk to enlarge the perivitelline space, partial digestion of the chorion with pancreatin, and removal of the weakened chorion with forceps. Dechorionated embryos underwent cleavage at a normal rate. Intracellular cytosolic [Ca2+]i was monitored by impaling blastomeres first with a microelectrode filled with 5 M potassium acetate to measure membrane potential, and a few minutes later with a calcium-selective microelectrode. During nine rounds of cytokinesis from a total of six different embryos, cytosolic [Ca2+]i remained constant (with apparently random fluctuations of less than +/- 0.1 microM). During two successive cleavages in one embryo, however, [Ca2+]i rose transiently fourfold above the original resting level to 1.32 and 1.20 microM in synchrony with each period of cytokinesis and returned after each rise to submicromolar levels. Because a calcium-selective microelectrode can detect [Ca2+]i changes only in the immediate vicinity of its 2-microns tip, we interpreted these data to suggest that, although [Ca2+]i in most areas of the cytosol remains between 0.01 and 0.40 microM (mean of 0.14 microM), there may be small regions of the cell in which [Ca2+]i undergoes a substantial increase at the time of cleavage. Evidence also is presented to suggest that the membrane potential in these blastomeres undergoes a slow net hyperpolarization during early cleavage stages.

Animals↗

Estimation of the membrane potential of cultured macrophages from the fast potential transient upon microelectrode entry.

Analysis of membrane potential recordings upon microelectrode impalement of four types of macrophages (cell lines P388D1 and PU5-1.8, cultured mouse peritoneal macrophages, and cultured human monocytes) reveals that these cells have membrane potentials at least two times more negative than sustained potential values (E(s)) frequently reported. Upon microelectrode entry into the cell (P388D1), the recorded potential drops to a peak value (E(p)) (mean -37 mV for 50 cells, range -15 to -70 mV) within 2 ms, after which it decays to a depolarized potential (E(n)) (mean -12 mV) in about 20 ms. Thereafter, the membrane develops one or a series of slow hyperpolarizations before a final sustained membrane potential (E(s)) (mean -14 mV, range -5 to -40) is established. The mean value of the peak of the first hyperpolarization (E(h)) is -30 mV (range -10 to -55 mV). The initial fast peak transient, measured upon microelectrode entry, was first described and analyzed by Lassen et al. (Lassen, U.V., A.M. T. Nielson, L. Pape, and L. O. Simonsen, 1971, J. Membr. Biol. 6:269-288 for other change in the membrane potential from its real value before impalement to a sustained depolarized value. This was shown to be true for macrophages by two-electrode impalements of single cells. Values of E(p), E(n), E(h), E(s), and membrane resistance (R(m)) measured for the other macrophages were similar to those of P388D1. From these results we conclude that E(p) is a better estimate of the true membrane potential of macrophages than E(s), and that the slow hyperpolarizations upon impalement should be regarded as transient repolarizations back to the original membrane potentials. Thus, analysis of the initial fast impalement transient can be a valuable aid in the estimation of the membrane potential of various sorts of small isolated cells by microelectrodes.

Animals↗

Histopathologic and physiologic effects of chronic implantation of microelectrodes in sacral spinal cord of the cat.

Active microelectrodes were implanted for a period of 2 weeks to 3 months into the sacral spinal cord of 10 male cats in order to test the feasibility and the safety of discrete stimulation of the parasympathetic preganglionic nucleus for future clinical applications of microelectrode technology in micturition control. An array of four 50 microns-diameter iridium microelectrodes was inserted beneath the dura in each cat. At weekly intervals, bladder pressure was measured as hydrostatic pressure on an intraluminal catheter. At the end of the period, histopathology was evaluated with serial transverse epoxy sections. Observations included diffuse and focal axonal degeneration in white matter and possible neuronal loss around the electrode in the gray matter, meningeal ensheathment of the shafts, and occasional aseptic inflammation of tissue and apparent movement of the electrodes after implantation. Increased bladder pressure responses to individually pulsed electrodes located within the sacral parasympathetic nucleus were not consistent, and, surprisingly, at least 2 different sites were also effective. As long as 3 months after implantation, in 2 out of 5 animals, pulsing of electrodes consistently produced micturition. We conclude that while microelectrode implants are feasible, further modifications in electrode design are needed to eliminate movement and inflammation.

Animals↗

Regeneration microelectrode array for peripheral nerve recording and stimulation.

A microelectrode array capable of recording from and stimulating peripheral nerves at prolonged intervals after surgical implantation has been demonstrated. The microelectrode array, fabricated on a silicon substrate perforated by multiple holes (referred to as via holes), is implanted between the ends of a surgically severed nerve. Regenerating tissue fixes the device in place to provide a stable mapping between the microelectrodes and the axons in the nerve. Processes were developed for the fabrication of thin-film iridium microelectrodes, micromachined via holes, and silicon nitride passivation layers. All fabrication methods were designed to be compatible with standard CMOS/BiCMOS processes to allow for on-chip signal processing circuits in future designs. Such arrays, implanted in the peroneal nerves of rats, were used to record from and stimulate the nerves at up to 13 months postoperatively.

Animals↗

A characterization of the effects on neuronal excitability due to prolonged microstimulation with chronically implanted microelectrodes.

Localized, long-lasting stimulation-induced depression of neuronal excitability (SIDNE) is a consequence of prolonged, high-frequency microstimulation in the central nervous system (CNS). It represents a persisting refractory state in the neurons and axons near the stimulating microelectrode, that occurs in the absence of histologically detectable tissue injury. It does not involve a change in synaptic efficacy and, in this respect, it differs from the more familiar phenomenon of long-term depression (LTD). Although SIDNE is ultimately reversible (after several days), it must be taken into account in the design of neural prostheses based on microstimulation in the central nervous system and in animal studies that require prolonged microstimulation in the CNS. In this study, we have characterized the phenomenon, using as the paradigm, iridium microelectrodes implanted chronically in the cat's posteroventral cochlear nucleus. Although the SIDNE may persist for several days after the end of the stimulation protocol, it does not become more severe from day to day when the stimulation protocol is repeated on successive days. The severity of the SIDNE is strongly dependent upon both the instantaneous frequency and the duty cycle of the electrical stimulation. The character of the SIDNE, including its localization to the immediate vicinity of the stimulating microelectrodes, suggests that the phenomenon is a direct consequence of the prolonged electrical excitation of the neurons close to the microelectrode. The problem of designing microstimulation systems that allow high-frequency stimulation of a neural substrate, while minimizing SIDNE are discussed.

Animals↗

Cultured neurons coupled to microelectrode arrays: circuit models, simulations and experimental data.

The purpose of this paper is to characterize the neuron-microelectrode junction, based on the equivalent electric-circuit approach. As a result, recording of action potentials can be simulated with a general-purpose circuit simulation program such as HSPICE. The response of the microelectrode was analyzed as a function of parameters such as sealing resistance and adhesion conditions. The models of the neuron and microelectrode implemented in HSPICE were first described. These models were used to simulate the behavior of the junction between a patch of neuronal membrane (described by the compartmental model) and a microelectrode.

Action Potentials↗

Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes.

Current neuroprosthetic systems based on electro-physiological recording have an extended, yet finite working lifetime. Some posited lifetime-extension solutions involve improving device biocompatibility or suppressing host immune responses. Our objective was to test an alternative solution comprised of applying a voltage pulse to a microelectrode site, herein termed "rejuvenation." Previously, investigators have reported preliminary electrophysiological results by utilizing a similar voltage pulse. In this study we sought to further explore this phenomenon via two methods: 1) electrophysiology; 2) an equivalent circuit model applied to impedance spectroscopy data. The experiments were conducted via chronically implanted silicon-substrate iridium microelectrode arrays in the rat cortex. Rejuvenation voltages resulted in increased unit recording signal-to-noise ratios (10% +/- 2%), with a maximal increase of 195% from 3.74 to 11.02. Rejuvenation also reduced the electrode site impedances at 1 kHz (67% +/- 2%). Neither the impedance nor recording properties of the electrodes changed on neighboring microelectrode sites that were not rejuvenated. In the equivalent circuit model, we found a transient increase in conductivity, the majority of which corresponded to a decrease in the tissue resistance component (44% +/- 7%). These findings suggest that rejuvenation may be an intervention strategy to prolong the functional lifetime of chronically implanted microelectrodes.

Action Potentials↗

Microelectrode array for chronic deep-brain microstimulation and recording.

We have developed an array of microelectrodes that is suitable for long-term implantation into the subthalamic nucleus (STN) or the globus pallidus and is able to record from single neurons, as well as deliver localized microstimulation. This device can be used to investigate the mechanisms by which deep brain stimulation can ameliorate the symptoms of Parkinson's disease and other movement disorders, and also may be the basis for a new clinical tool for the treatment of Parkinson's disease, by capitalizing on the high spatial specificity of intranuclear microstimulation. The array includes 16 activated iridium microelectrodes, 5-6 mm in length, within a cluster approximately 1.8 mm in diameter. We have fabricated the array using materials carrying the USP Category VI classification, and we have developed an apparatus and a procedure for implanting the microelectrode arrays into the deep brain. Ten arrays have been implanted into the STN of domestic cats, and one into the internal segment of the globus pallidus, for 140-415 days. During that time, we were able to record action potentials from individual neurons, on 4 to 8 of the 16 channels. The microelectrode' active surface areas ranged from 500 to 2000 microm2. Controlled-current pulses, 26.5 microA in amplitude and 150 micros/phase in duration (4 nC/phase) were used to excite neurons in the cat's STN. In addition to direct activation, the stimulus modulated the neuronal activity over a distance of at least 1.2 mm from the site of stimulation. These parameters did not induce histologically detectable changes around the tip sites after 35 hours of stimulation at 100 Hz (7 hours of stimulation per day, on 5 successive days), if the electrode' active surface area was 1000 microm2 or greater.

Action Potentials↗

A new design of double-barrelled microelectrodes for intracellular pH-measurement in vivo.

Intracellular pH (pHi) is one important regulator of cellular function. Most determinations of pHi in vivo have been performed by using indirect methods, e.g. CO2/HCO3 or DMO techniques, since no suitable direct method for reliable in vivo measurements have been available. In the present study a new type of double-barrelled microelectrode for simultaneous in vivo measurements of pHi and membrane potential (Em) is presented. The electrode was constructed on the basis of a combined recessed- and pencil-tip design. The tip diameter of the double-barrelled microelectrode was about 1.5 microns. The response of the pH channel was 55-60 mV/pH unit and the response time was between 30 s and 1 min. In vivo measurements of pHi and Em of rabbit skeletal muscle fibers are presented. A mean pHi of 7.00 (in 8 animals) at a membrane potential of -90.3 mV (arterial pH: 7.30, arterial PCO2: 6.39 kPa) was obtained. The new design of pH microelectrode offers some advantages over previously described microelectrodes and is well suited for in vivo measurements.

Animals↗

Cell contamination due to the use of carrier-based microelectrodes.

When using microelectrodes for intracellular ion activity studies, some uncertainties such as interference from cytosolic components at the microelectrode, cell damage, and cell contamination may arise. A model, which treats kinetic processes of the loss of carriers from the membrane phase of microelectrodes into the cytosol and cell membrane, is used for an estimation of the extent and time course of contamination by impaled ion-selective microelectrodes. An isolated model cell consisting of a plasma membrane surrounding a cytosolic milieu is assumed. The results of its considerations represent a worst case situation, in which significant contamination of the cell membrane of such a small isolated single cell might occur during time periods of electrophysiological experiments. In more complex situations, such as in intact tissues, the equilibrium membrane concentrations may be substantially less.

Animals↗

Measurements of intracellular pH in Necturus antral mucosa by microelectrode technique.

Intracellular pH (pHi) was measured in the surface epithelial cells of Necturus antrum using pH-sensitive intracellular microelectrodes. Electrodes were prepared by filling 10- to 20-M omega resistance glass microelectrodes with a H+ ion-selective exchange resin and calibrated before use in solutions of known pH 4.0-8.0. The electrode response (n = 15) was linear (r = 0.93; P less than 0.001) with a slope of 52.1 +/- 2.3 mV/pH unit. Antral mucosa was mounted in a modified Ussing chamber and pHi was determined from the difference between the potentials recorded by intracellular H+-selective and conventional microelectrodes. These measurements of pHi were validated by examining the response of the intracellular microelectrodes to 1) depolarization of the cell membrane produced by K+ substitution for Na+, and 2) alkalinization and acidification of pHi produced by NH+4 substitution for Na+ in the bathing solutions. In tissues bathed with HCO-3-Ringer solution (pH 7.0), the mean pHi was 7.34 +/- 0.02 with a range from 7.24 to 7.43. In N-2-hydroxymethylpiperazine-N' -ethanesulfonic acid (HEPES)-Ringer solution (pH 7.0), pHi was reduced to 7.02 +/- 0.05 (P less than 0.01). Acidification of the luminal solution to pH 6.8 with CO2 produced a 0.22 +/- 0.04-pH unit fall in pHi (P less than 0.001). In contrast, acidification to pH 4.0 with HCl had no significant effects on pHi. These findings indicate that HCO-3 may play an important role in pHi regulation in this tissue. In addition, they suggest that, in contrast to CO2, the surface epithelial cells of Necturus antrum are relatively resistant to acidification by luminal HCl.

Animals↗