PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

An effervescent reaction micropump for portable microfluidic systems.

A water-activated, effervescent reaction was used to transport fluid in a controllable manner on a portable microfluidic device. The reaction between sodium bicarbonate and an organic acid, tartaric acid and/or benzoic acid, was modeled to analyze methods of controlling the generation of carbon-dioxide gas for the purposes of pumping fluids. Integration and testing of the effervescent reaction pump in a microfluidic device was made possible by using elastomeric polymers as both photopolymerizable septa and removable lids. These materials combined to enable facile access to otherwise gas-tight devices. Based on theoretical predictions for 0.33 mg of sodium bicarbonate and a stoichiometric amount of organic acid, the pumping flow rate could be varied from 0.01 microL s(-1) to 70 microL s(-1). The flow rate is controlled by adjusting any or all of the particle size of the least soluble reactant, the amount of reactants used, and the type of organic acid selected. The tartaric acid systems rapidly produce carbon dioxide; however, the gas generation rates dramatically decrease over the course of the reaction. In contrast, carbon dioxide production rate in the benzoic acid systems is lower and nearly constant for several minutes. Water activation and direct placement on a microfluidic device are key features of this micropump, which is therefore useful for portable microfluidic applications.

Microfluidics↗

Microfluidic technologies as platforms for performing quantitative cellular analyses in an in vitro environment.

Quite often, important cellular events occur in environments that are either not amenable to implanted sensors or other types of molecular probes. In such cases, a viable alternative to taking the sensor or probe to the biological sample of interest is to bring the sample of interest out of its natural environment to one that is more conducive to the measurement scheme. The disadvantage of the latter approach is that the sample may not behave in the same manner in vitro as it does in vivo, or that the agonists and other stimuli to which the sample is subjected to in vivo are no longer present. In this Tutorial Review, the authors attempt to provide some guidance, based on their own experiences and those of other scientists, to performing cellular measurements in a quantitative manner under in vitro conditions. Due to the expansive literature on analyses involving cells, the authors have limited this Tutorial Review to those methods involving microfluidic technologies, both in microbore tubing and in microfabricated channels. Initial reports of analyses involving cells in microbore tubing were first reported nearly two decades ago, while those in microfabricated fluidic devices appeared over a decade ago. However, more recently, the complexity of cell analyses using fabricated microfluidic devices (as opposed to microbore tubing) has increased due in part to the improvements in fabrication technologies, fluid handling and delivery capabilities, advances in coatings of the channels within the microfluidic device, and integrated detection schemes. Examples of cellular analyses in microbore tubing and in fabricated microfluidic devices will be given, as well as associated advantages and challenges. Finally, the authors' thoughts on cellular analyses are presented here using the classical steps in an analysis as a guide.

Animals↗

Absorption detection of enzymatic reaction using optical microfluidics based intermittent flow microreactor system.

The advantages of integrating microfluidics into photonics-based biosensing for fabricating microreactor type lab-on-a-chip devices carries a lot of advantages, such as smaller sample volume handling, controlled drug delivery and high throughput diagnosis, which is useful for in situ medical diagnosis and point-of-care (POC) testing. A hybrid integrated optical microfluidic system has been developed for the study of single molecules and enzymatic reactions. The method of optical absorption has been employed for biosensing and the feasibility of absorption-based detection on the microfluidic platform has been demonstrated using horseradish peroxidase and hydrogen peroxide, as an example. The results show that the device is useful for the analysis of both the individual chemical specimen and also the study of chemical and biological reaction between two reacting species. The hybrid integration of microfluidics and optical ensembles thus forms the basis for developing the microreactor type lab-on-a-chip device, which would have several important applications in the area of nanobiotechnology.

Absorption↗

Structural and functional imaging of 3D microfluidic mixers using optical coherence tomography.

To achieve high mixing efficiency in microfluidic devices, complex designs are often required. Microfluidic devices have been evaluated with light and confocal microscopy, but fluid-flow characteristics at different depths are difficult to separate from the en face images produced. By using optical coherence tomography (OCT), an imaging modality capable of imaging 3D microstructures at micrometer-scale resolutions over millimeter-size scales, we obtained 3D dynamic functional and structural data for three representative microfluidic mixers: a Y channel mixer, a 3D serpentine mixer, and a vortex mixer. In the serpentine mixer, OCT image analysis revealed that the mixing efficiency was linearly dependent on the Reynolds number, whereas it appeared to have exponential dependence when imaged with light microscopy. The visual overlap of fluid flows in light-microscopy images leads to an overestimation of the mixing efficiency, an effect that was eliminated with OCT imaging. Doppler OCT measurements determined velocity profiles at various points in the serpentine mixer. Mixing patterns in the vortex mixer were compared with light-microscopy and OCT image analysis. These results demonstrate that OCT can significantly improve the characterization of 3D microfluidic device structure and function.

Microfluidics↗

Microfluidics for flow cytometric analysis of cells and particles.

This review describes recent developments in microfabricated flow cytometers and related microfluidic devices that can detect, analyze, and sort cells or particles. The high-speed analytical capabilities of flow cytometry depend on the cooperative use of microfluidics, optics and electronics. Along with the improvement of other components, replacement of conventional glass capillary-based fluidics with microfluidic sample handling systems operating in microfabricated structures enables volume- and power-efficient, inexpensive and flexible analysis of particulate samples. In this review, we present various efforts that take advantage of novel microscale flow phenomena and microfabrication techniques to build microfluidic cell analysis systems.

Animals↗

Rethinking gamete/embryo isolation and culture with microfluidics.

IVF remains one of the most exciting modern scientific developments and continues to have a tremendous impact on people's lives. Since its beginnings, scientists have studied and critically analysed the techniques in order to find ways to improve outcomes; however, little has changed with the actual technology and equipment of IVF. Semen is still processed in test tubes and fertilization and culture still occurs in culture dishes. New technological possibilities exist with the burgeoning advancement of microfluidic technology. Microfluidics is based on the behaviour of liquids in a microenvironment. Although a young field, many developments have occurred which demonstrate the potential of this technology for IVF. In this review, we briefly discuss the physical principles of microfluidics and highlight some previous utilizations of this technology, ranging from chemical analysis to cell sorting. We then present the designs and outcomes for microfluidic devices utilized thus far for each step in IVF: gamete isolation and processing, fertilization, and embryo culture. Finally, we discuss and speculate on the ultimate goal of this technology--development of a single, integrated unit for in-vitro assisted reproduction techniques.

Cell Culture Techniques↗

A microfluidic-FCS platform for investigation on the dissociation of Sp1-DNA complex by doxorubicin.

The transcription factor (TF) Sp1 is a well-known RNA polymerase II transcription activator that binds to GC-rich recognition sites in a number of essential cellular and viral promoters. In addition, direct interference of Sp1 binding to DNA cognate sites using DNA-interacting compounds may provide promising therapies for suppression of cancer progression and viral replication. In this study, we present a rapid, sensitive and cost-effective evaluation of a GC intercalative drug, doxorubicin (DOX), in dissociating the Sp1-DNA complex using fluorescence correlation spectroscopy (FCS) in a microfluidic system. FCS allows assay miniaturization without compromising sensitivity, making it an ideal analytical method for integration of binding assays into high-throughput, microfluidic platforms. A polydimethylsiloxane (PDMS)-based microfluidic chip with a mixing network is used to achieve specific drug concentrations for drug titration experiments. Using FCS measurements, the IC50 of DOX on the dissociation of Sp1-DNA complex is estimated to be 0.55 microM, which is comparable to that measured by the electrophoretic mobility shift assay (EMSA). However, completion of one drug titration experiment on the proposed microfluidic-FCS platform is accomplished using only picograms of protein and DNA samples and less than 1 h total assay time, demonstrating vast improvements over traditional ensemble techniques.

DNA↗

Using a microfluidic device for 1 microl DNA microarray hybridization in 500 s.

This work describes a novel and simple modification of the current microarray format. It reduces the sample/reagent volume to 1 microl and the hybridization time to 500 s. Both 20mer and 80mer oligonucleotide probes and singly labeled 20mer and 80mer targets, representative of the T-cell acute lymphocytic leukemia 1 (TAL1) gene, have been used to elucidate the performance of this hybridization approach. In this format, called shuttle hybridization, a conventional flat glass DNA microarray is integrated with a PMMA microfluidic chip to reduce the sample and reagent consumption to 1/100 of that associated with the conventional format. A serpentine microtrench is designed and fabricated on a PMMA chip using a widely available CO2 laser scriber. The trench spacing is compatible with the inter-spot distance in standard microarrays. The microtrench chip and microarray chip are easily aligned and assembled manually so that the microarray is integrated with a microfluidic channel. Discrete sample plugs are employed in the microchannel for hybridization. Flowing through the microchannel with alternating depths and widths scrambles continuous sample plug into discrete short plugs. These plugs are shuttled back and forth along the channel, sweeping over microarray probes while re-circulation mixing occurs inside the plugs. Integrating the microarrays into the microfluidic channel reduces the DNA-DNA hybridization time from 18 h to 500 s. Additionally, the enhancement of DNA hybridization reaction by the microfluidic device is investigated by determining the coefficient of variation (CV), the growth rate of the hybridization signal and the ability to discriminate single-base mismatch. Detection limit of 19 amol was obtained for shuttle hybridization. A 1 mul target was used to hybridize with an array that can hold 5000 probes.

Basic Helix-Loop-Helix Proteins↗

Microfluidic techniques for single-cell protein expression analysis.

BACKGROUND: The analysis of single cells obtained from needle aspirates of tumors is constrained by the need for processing. To this end, we investigated two microfluidic approaches to measure the expression of surface proteins in single cancer cells or in small populations (<50 cells). METHODS: One approach involved indirect fluorescence labeling of cell-surface proteins and channeling of cells in a microfluidic device past a fluorescence detector for signal quantification and analysis. A second approach channeled cells in a microfluidic device over detection zones coated with ligands to surface proteins and measured rates of passage and of retardation based on transient interactions between surface proteins and ligands. RESULTS: The fluorescence device detected expression of integrin alpha5 induced by basic fibroblast growth factor (FGF-2) treatment in MCF-7 cells and that of Her-2/neu in SK-BR-3 cells compared with controls. Experiments measuring passage retardation showed significant differences in passage rates between FGF-2-treated and untreated MCF-7 cells over reaction regions coated with fibronectin and antibody to integrin alpha5beta1 compared with control regions. Blocking peptides reversed the retardation, demonstrating specificity. CONCLUSIONS: Immunofluorescence detection in a microfluidic channel demonstrates the potential for assaying surface protein expression in a few individual cells and will permit the development of future iterations not requiring cell handling. The flow retardation device represents the first application of this technology for assessing cell-surface protein expression in cancer cells and may provide a way for analyzing expression profiles of single cells without preanalytical manipulation.

Antibodies↗

Microfluidic chambers for cell migration and neuroscience research.

This chapter describes the fabrication and use microfluidic chambers for cell migration and neuroscience research. Both microfluidic chambers are made using soft lithography and replica molding. The main advantages of using soft lithography to create microfluidic chambers are reproducibility, ease of use, and straightforward fabrication procedures. The devices can be fabricated in biology and chemistry laboratories with minimal access to clean-room facilities. First, a microfluidic chemotaxis chamber, which has been used in investigating chemotaxis of neutrophils, human breast cancer cells, and other cell types, is described. Precise and stable gradients of chemoattractants with arbitrary shapes can be generated for different applications. Second, a multicompartment culture chamber that can fluidically isolate neuronal processes from cell bodies is described. The design of this chamber is such that only neurites grow through a series of microgrooves embedded in a physical barrier. Both devices are compatible with phase, differential interference contrast, and fluorescence microscopy.

Animals↗

Fabrication of micromachined magnetic particle separators for bioseparation in microfluidic systems.

Fabrication of micromachined magnetic particle separators is introduced with an emphasis on magnetic particle-based bioseparation in microfluidic systems. The most attractive aspect of the magnetic separation technique in biochemistry and biotechnology is ease of manipulation of biomolecules, which are immobilized on magnetic particles. Embedded electromagnets in the microfluidic channel are described for on-chip magnetic particle separation for lab-on-a-chip applications. An example of microfluidic systems with a magnetic particle separator and integrated microfluidic components is also presented for rapid magnetic particle-based bioseparation and immunoassay.

Electromagnetic Phenomena↗

Hydrogel-immobilized antibodies for microfluidic immunoassays: hydrogel immunoassay.

The integration of immunoassays in microfluidic devices is a rapidly developing research area combining the power of immunoassays with the inherent benefits of microfluidics. Here, a general overview of microfluidic-based immunoassays is presented along with a method for immobilizing antibodies in polyacrylamide gel plugs set in microfluidic channels. These antigen-specific hydrogels can be rapidly formed by photopolymerizing monomer solutions mixed with antibodies or other large proteins. The resulting antigen-specific hydrogels contain pore sizes appropriate for physical entrapment of large antibodies while remaining permeable to smaller proteins. The open structure of these hydrogels enables the capture and concentration of target antigens present at low concentrations. Such physical entrapment provides a conceptually simple method of immobilization compared with immobilization of proteins on surfaces and offers advantages such as resistance to chemical and thermal denaturation.

Acrylic Resins↗

Fabrication of polymer microfluidic systems by hot embossing and laser ablation.

Fabrication of microfluidic channels in common commercially available thermoplastic materials can be easily accomplished using hot embossing or ultraviolet (UV) laser ablation. Hot embossing involves replication of a microfluidic network in a polymer substrate from a stamp (or template) fabricated in silicon or metal. UV laser ablation is performed by either exposing the polymer substrate through a mask or by using a laser direct-write process. The resulting polymer microfluidic channels are most often sealed with another polymer piece using thermal bonding or solvent bonding to complete the fabrication procedure. Unlike their silicon and glass counterparts, polymer microfluidic systems can be fabricated by these methods in less than 1 h, making the materials attractive for both research prototyping and commercialization.

Equipment Design↗

Integrated microfluidic biochips for DNA microarray analysis.

A fully integrated and self-contained microfluidic biochip device has been developed to automate the fluidic handling steps required to perform a gene expression study of the human leukemia cell line (K-562). The device consists of a DNA microarray semiconductor chip with 12,000 features and a microfluidic cartridge that consists of microfluidic pumps, mixers, valves, fluid channels and reagent storage chambers. Microarray hybridization and subsequent fluidic handling and reactions (including a number of washing and labeling steps) were performed in this fully automated and miniature device before fluorescent image scanning of the microarray chip. Electrochemical micropumps were integrated in the cartridge to provide pumping of liquid solutions. A micromixing technique based on gas bubbling generated by electrochemical micropumps was developed. Low-cost check valves were implemented in the cartridge to prevent cross-talk of the stored reagents. A single-color transcriptional analysis of K-562 cells with a series of calibration controls (spiked-in controls) was performed to characterize this new platform with regard to sensitivity, specificity and dynamic range. The device detected sample RNAs with a concentration as low as 0.375 pM. Detection was quantitative over more than 3 orders of magnitude. Experiments also demonstrated that chip-to-chip variability was low, indicating that the integrated microfluidic devices eliminate manual fluidic handling steps that can be a significant source of variability in genomic analysis.

Biomarkers↗

Disposable microfluidic devices: fabrication, function, and application.

This review article describes recent developments in microfluidics, with special emphasis on disposable plastic devices. Included is an overview of the common methods used in the fabrication of polymer microfluidic systems, including replica and injection molding, embossing, and laser ablation. Also described are the different methods by which on-chip operations--such as the pumping and valving of fluid flow, the mixing of different reagents, and the separation and detection of different chemical species--have been implemented in a microfluidic format. Finally, a few select biotechnological applications of microfluidics are presented to illustrate both the utility of this technology and its potential for development in the future.

Biosensing Techniques↗

Integration of polymeric membranes with microfluidic networks for bioanalytical applications.

The concept of microfluidics has significantly influenced the design and the implementation of modern bioanalytical systems due to the fact that these miniaturized devices can handle and manipulate samples in a much more efficient way than conventional instruments. In an analogy to the development of microelectronics, increasingly sophisticated devices with greater functionalities have become one of the major goals being pursued in the area of micrototal analysis systems. The incorporation of polymeric membranes into microfluidic networks has therefore been employed in an effort to enhance the functionalities of these microfabricated devices. These commercially available membranes are porous, flexible, mechanically robust and compatible with plastic microfluidic networks. The large surface area-to-volume ratio of porous membrane media is particularly important for achieving rapid buffer exchange during microdialysis and obtaining ultrahigh concentration of adsorbed enzymes for various biochemical reactions. Furthermore, the membrane pore diameter in the sub-microm range eliminates the constraints of diffusional mass-transfer resistance for performing chiral separation using adsorbed protein as the chiral stationary phase. A review on the recent advancement in the integration of polymeric membranes with microfluidic networks is presented for their widespread applications in bioanalytical chemistry.

Adsorption↗

Sample purification on a microfluidic device.

Sample preparation has long been recognized as a significant barrier to the implementation of macroscopic protocols on microfabricated devices. Macroscopically, such tasks as removing salts, primers and other contaminants are performed by methods involving precipitation, specialized membranes and centrifuges, none of which are readily performed in microfluidic structures. Although some microfluidic systems have been developed for performing sample purification, their complexity may hinder the degree to which they can be implemented. We present a method of microchip-based sample purification that can be performed with even the simplest microfluidic designs. The technique is demonstrated by removing primers from a sample of amplified DNA, leaving only the product DNA. This provides a new sample preparation capability for microfluidic systems.

DNA↗

Single molecule detection of double-stranded DNA in poly(methylmethacrylate) and polycarbonate microfluidic devices.

Single photon burst techniques were used to detect double-stranded DNA molecules in poly(methylmethacrylate) (PM MA) and polycarbonate (PC) microfluidic devices. A confocal epi-illumination detection system was constructed to monitor the fluorescence signature from single DNA molecules that were multiply labeled with the mono-intercalating dye, TOPRO-5, which possessed an absorption maximum at 765 nm allowing excitation with a solid-state diode laser and fluorescence monitoring in the near-infrared (IR). Near-IR excitation minimized autofluorescence produced from the polymer substrate, which was found to be significantly greater when excitation was provided in the visible range (488 nm). A solution containing lambda-DNA (48.5 kbp) was electrokinetically transported through the microfluidic devices at different applied voltages and solution pH values to investigate the effects of polymer substrate on the transport rate and detection efficiency of single molecular events. By applying an autocorrelation analysis to the data, we were able to obtain the molecular transit time of the individual molecules as they passed through the 7 microm laser beam. It was observed that the applied voltage for both devices affected the transport rate. However, solution pH did not alter the transit time for PM MA-based devices since the electroosmotic flow of PMMA was independent of solution pH. In addition, efforts were directed toward optimizing the sampling efficiency (number of molecules passing through the probe volume) by using either hydrodynamically focused flows from a sheath generated by electrokinetic pumping from side channels or reducing the channel width of the microfluidic device. Due to the low electroosmotic flows generated by both PMMA and PC, tight focusing of the sample stream was not possible. However, in PMMA devices, flow gating was observed by applying field strengths > -120 V/cm to the sheath flow channels. By narrowing the microchannel width, the number of molecular events detected per unit time was found to be four times higher in channels with 10 microm widths compared to those of 50 microm, indicating improved sampling efficiency for the narrower channels without significantly deteriorating detection efficiency. Attempts were made to do single molecule sizing of lambda-DNA, M13 (7.2 kbp) and pUC19 (2.7 kbp) using photon burst detection. While the average number of photons for each DNA type were different, the standard deviations were large due to the Gaussian intensity profile of the excitation beam. To demonstrate the sensitivity of single molecule analysis in the near-IR using polymer microfluidic devices, the near-IR chromophore, NN382, wasanalyzed using ourconfocal imager. A detection efficiency of 94% for single NN382 molecules was observed in the PC devices.

Bacteriophage lambda↗