PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microscopy, Scanning Probe”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Imaging of DNA by scanning force microscopy.

The scanning probe microscopies applied to the sequencing of DNA is a challenging goal attempted by several groups. But one limitant parameter has been the sample preparation of DNA molecules. Here we report how to hold DNA molecules fixed on mica substrate and we show the three-dimensional configuration of double-stranded DNA obtained with our scanning force microscope. We can image DNA under negative supercoiling, a feature of general importance controlling the activities of DNA. We compared the electron micrographs of a carbon replica of the same DNA specimen with scanning force images which demonstrates well the feasibility and accuracy of our scanning probe measurements.

DNA↗

A tumor-targeted nanodelivery system to improve early MRI detection of cancer.

The development of improvements in magnetic resonance imaging (MRI) that would enhance sensitivity, leading to earlier detection of cancer and visualization of metastatic disease, is an area of intense exploration. We have devised a tumor-targeting, liposomal nanodelivery platform for use in gene medicine. This systemically administered nanocomplex has been shown to specifically and efficiently deliver both genes and oligonucleotides to primary and metastatic tumor cells, resulting in significant tumor growth inhibition and even tumor regression. Here we examine the effect on MRI of incorporating conventional MRI contrast agent Magnevist into our anti-transferrin receptor single-chain antibody (TfRscFv) liposomal complex. Both in vitro and in an in vivo orthotopic mouse model of pancreatic cancer, we show increased resolution and image intensity with the complexed Magnevist. Using advanced microscopy techniques (scanning electron microscopy and scanning probe microscopy), we also established that the Magnevist is in fact encapsulated by the liposome in the complex and that the complex still retains its nanodimensional size. These results demonstrate that this TfRscFv-liposome-Magnevist nanocomplex has the potential to become a useful tool in early cancer detection.

Animals↗

Near-field scanning optical microscopy in cell biology.

Near-field optics has produced the highest optical resolution that has ever been achieved. The methods involved lie at the interface of far-field optical microscopy and scanned probe microscopy. This article describes the principles behind near-field scanning optical microscopy (NSOM) and highlights its potential in cell biology.

Humans↗

Pharmaceutical applications of micro-thermal analysis.

Micro-thermal analysis is a recently introduced thermoanalytical technique that combines the principles of scanning probe microscopy with thermal analysis via replacement of the probe tip with a thermistor. This allows samples to be spatially scanned in terms of both topography and thermal conductivity, whereby placing the probe on a specific region of a sample and heating, it is possible to perform localized thermal analysis experiments on those regions. In this minireview, the principles of the technique are outlined and the current uses within the polymer sciences described. Current pharmaceutical applications are then discussed; these include the identification of components in compressed tablets, the characterization of drug-loaded polylactic acid microspheres, the analysis of tablet coats, and the identification of amorphous and crystalline regions in semicrystalline samples. The current strengths and weaknesses of the technique are outlined, along with a discussion of the future directions in which the approach may be taken.

Crystallization↗

Biological thermal detection in infrared imaging snakes. 1. Ultramicrostructure of pit receptor organs.

The receptor organs of snakes with "thermal vision" were studied with ultra-high-resolution scanning probe microscopy (SPM) at close to in vivo conditions to elucidate their surface morphology and materials properties critical for prospective biomimetic design of "soft matter"-based infrared (IR) sensors. The surfaces of living tissues were scanned under wet ambient conditions in physiological solution, and the resulting parameters were compared with SPM data obtained for chemically treated (formaldehyde-fixed) tissue in ambient air and TEM studies in high vacuum. We found that the microstructural parameters for the living tissue are similar to ones observed for the formaldehyde-fixed snake tissues. However, previous data obtained from TEM analysis in high vacuum underestimated actual dimensions of surface microstructures. The average spacing of the nanopit array observed within receptor surface areas, which was suggested to play a critical role in selective IR adsorption, was determined to be 520 nm. This value is close to the grating spacing required for efficient reflection of electromagnetic radiation characteristic for sunlight without affecting IR adsorbance.

Animals↗

Gradient chemical micro patterns: a reference substrate for surface nanometrology.

We present fabrication routes for a new type of surface specimen that exhibits a micro pattern with a gradient in chemical contrast between the pattern domains. Design elements in the specimen allow chemical contrast in the micro pattern to be related to well-established surface characterization data, such as contact angle measurements. These gradient specimens represent a reference tool for calibrating image contrast in chemically sensitive scanning probe microscopy techniques and a platform for the high-throughput analysis of polymer thin film behavior.

Materials Testing↗

Scanning probe microscopic studies of the oriented attachment and membrane reconstitution of cytochrome C oxidase to a gold electrode.

Scanning probe microscopy was used to monitor the resulting surface of the oriented incorporation of cytochrome c oxidase into electrode supported lipid bilayer at four crucial stages with molecular resolution. We were able to reveal the formation of a densely packed monolayer of the active ester dithio(succiniimidylepropionate) (DTSP) and the covalent linkage of the nitrilotriacetic acid (NTA) to the thiol anchored DTSP by scanning tunneling microscopy. Atomic force microscopy investigations showed that the detergent solubilized oxidase is immobilized as monomers and small aggregates via histidine residues. Finally, the reconstitution of the proteins within the supported membrane was verified. The amount of oxidase immobilized within the solid supported membrane was estimated.

Electrodes↗

Nanoscale imaging of buried structures via scanning near-field ultrasound holography.

A nondestructive imaging method, scanning near-field ultrasound holography (SNFUH), has been developed that provides depth information as well as spatial resolution at the 10- to 100-nanometer scale. In SNFUH, the phase and amplitude of the scattered specimen ultrasound wave, reflected in perturbation to the surface acoustic standing wave, are mapped with a scanning probe microscopy platform to provide nanoscale-resolution images of the internal substructure of diverse materials. We have used SNFUH to image buried nanostructures, to perform subsurface metrology in microelectronic structures, and to image malaria parasites in red blood cells.

Animals↗

Modeling electric-field-sensitive scanning probe measurements for a tip of arbitrary shape.

We present a numerical method to model electric-field-sensitive scanning probe microscopy measurements which allows for a tip of arbitrary shape and invokes image charges to exactly account for a sample dielectric overlayer. The method is applied to calculate the spatial resolution of a subsurface charge accumulation imaging system, achieving reasonable agreement with experiment.

Algorithms↗

Noncontact dielectric friction.

Dielectric fluctuations are shown to be the dominant source of noncontact friction in high-sensitivity scanning probe microscopy of dielectric materials. Recent measurements have directly determined the friction acting on custom-fabricated single-crystal silicon cantilevers whose capacitively charged tips are located 3-200 nm above thin films of poly(methyl methacrylate), poly(vinyl acetate), and polystyrene. Differences in measured friction among these polymers are explained here by relating electric field fluctuations at the cantilever tip to dielectric relaxation of the polymer.

Electric Impedance↗

Drastic change of local stiffness distribution correlating to cell migration in living fibroblasts.

Sequential images of the local stiffness distribution of living fibroblasts (NIH3T3) were captured under a culture condition using scanning probe microscopy in a force modulation mode. We found a clear relation between cell migration and local stiffness distribution on the cell: When cells were stationary at one position, the stiffness distribution of their cellular surface was quite stable. On the other hand, once the cells started to move, the stiffness in their nuclear regions drastically decreased. Possible explanations for the correlation between the cell migration and the cell stiffness are proposed.

3T3 Cells↗

Ferroelectric molecular films for nanoscopic ultrahigh-density memories.

The formation and visualization of nanometer-scale polarized domains in ultrathin ferroelectric molecular films by scanning-probe microscopy are described. These operations to the ferroelectric domains correspond to the "writing" and the "reading" process, respectively, for the data-storage application. In addition, nanometer-scale structures and the local electrical properties of the local domains, including the interface effect, are discussed. The achieved minimum diameter of the written ferroelectric domains was 30 nm. The size of the "recording" dot corresponds to the recording density of about 230 Gbit/in.(2). The "erasing" process by switching domains was also demonstrated. Furthermore, nanometer-scale ferroelectric domains using VDF oligomer molecular films were successfully formed, which has opened the way to the control of single molecular dipoles.

Iron↗

Self-assembly, DNA complexation, and pH response of amphiphilic dendrimers for gene transfection.

Cationic lipids and polymers are routinely used for cell transfection, and a variety of structure-activity relation data have been collected. Few studies, however, focus on the structural aspects of self-assembly as a crucial control parameter for gene delivery. We present here the observations collected for a set of cationic dendritic amphiphiles based on a stiff tolane core (1-4) that are built from identical subunits but differ in the number and balance of their hydrophobic and cationic hydrophilic moieties. We established elsewhere that vectors 3 and 4 have promising transfection properties. Scanning probe microscopy (AFM, STM), cryo-transmission electron microscopy (cryo-TEM), and Langmuir techniques provide insight into the self-assembly properties of the molecules under physiological conditions. Furthermore, we present DNA and pH "jump" experiments where we study the response of Langmuir films to a sudden increase in DNA concentration or a drop in pH. We find that the primary self-assembly of the amphiphile is of paramount importance and influences DNA binding, serum sensitivity, and pH response of the vector system.

Cations↗

Ultramicrostructure and microthermomechanics of biological IR detectors: materials properties from a biomimetic perspective.

Microstructural organization of the biological infrared (IR) receptors was studied to elucidate their materials properties useful for prospective biomimetic design of artificial IR sensors from organic/polymeric materials. The IR receptors in Melanophila acuminata beetles were studied with ultrahigh-resolution scanning probe microscopy (SPM) in a range of temperatures. By application of micromechanical mapping and thermal stage, we made attempts to reveal the micromechanical and thermomechanical properties of the cuticular apparatus of the IR sensillum. The main component of the cuticular apparatus is an internal endocuticular sphere with a diameter of about 15-20 microm. Highly ordered multilayered organization of the lamellated peripheral mantle of the sphere was confirmed and characterized. We observed that the interlayer spacing of this microstructure varied along the circumference and decreased to 300 nm in the vertex of the sphere. We demonstrated that the microlayered structure is composed of nanolayers with very different micromechanical properties and thermal behaviors. Thermal expansion of the outer mantle was observed, and the local thermal expansion coefficient under given preparation conditions was estimated to be below 1.5 x 10(-4) grad(-1).

Animals↗

Cellular stiffness response to external deformation: tensional homeostasis in a single fibroblast.

Stiffness responses of fibroblasts were measured by scanning probe microscopy, following elongation or compression by deformation of an elastic substrate by 8%. The cellular stiffness, reflecting intracellular tension acting along stress fibers, decreased or increased instantly in response to the elongating or compressing stimuli, respectively. After this rapid change, the fibroblasts gradually recovered to their initial stiffness during the following 2 h, and then stabilized. The cells did not show conspicuous changes in shape after the 8% deformation during the SPM measurements. Fluorescence examination for GFP-actin demonstrated that the structure of the stress fibers was not altered noticeably by this small degree of deformation. Treatment with Y-27632, to inhibit myosin phosphorylation and abrogate cellular contractility, eliminated the change in stiffness after the mechanical elongation. These results indicate that fibroblasts possess a mechanism that regulates intracellular tension along stress fibers to maintain the cellular stiffness in a constant equilibrium state.

Actins↗

Diatom bionanotribology--biological surfaces in relative motion: their design, friction, adhesion, lubrication and wear.

Tribology is the branch of engineering that deals with the interaction of surfaces in relative motion (as in bearings or gears): their design, friction, adhesion, lubrication and wear. Continuous miniaturization of technological devices like hard disc drives and biosensors increases the necessity for the fundamental understanding of tribological phenomena at the micro- and nanoscale. Biological systems show optimized performance also at this scale. Examples for biological friction systems at different length scales include bacterial flagella, joints, articular cartilage and muscle connective tissues. Scanning probe microscopy opened the nanocosmos to engineers: not only is microscopy now possible on the atomic scale, but even manipulation of single atoms and molecules can be performed with unprecedented precision. As opposed to this top-down approach, biological systems excel in bottom-up nanotechnology. Our model system for bionanotribological investigations are diatoms, for they are small, highly reproductive, and since they are transparent, they are accessible with different kinds of optical microscopy methods. Furthermore, certain diatoms have proved to be rewarding samples for mechanical and topological in vivo investigations on the nanoscale. There are several diatom species that actively move (e.g. Bacillaria paxillifer forms colonies in which the single cells slide against each other) or which can, as cell colonies, be elongated by as much as a major fraction of their original length (e.g. Ellerbeckia arenaria colonies can be reversibly elongated by one third of their original length). Therefore, we assume that some sort of lubrication of interactive surfaces is present in these species. Current studies in diatom bionanotribology comprise techniques like atomic force microscopy, histochemical analysis, infrared spectrometry, molecular spectroscopy and confocal infrared microscopy.

Cell Adhesion↗

Contribution of cellular contractility to spatial and temporal variations in cellular stiffness.

Scanning probe microscopy and immunofluorescence observations indicated that cellular stiffness was attributed to a contractile network structure consisting of stress fibers. We measured temporal variations in cellular stiffness when cellular contractility was regulated by dosing with lysophosphatidic acid or Y-27632. This experiment revealed a clear relation between cellular stiffness and contractility: Increases in contractility caused cells to stiffen. On the other hand, decreases in contractility reduced cellular stiffness. In both cases, not only the stiffness of the stress fibers but also that of the whole of the cell varied. Immunofluorescence observations of myosin II and vinculin indicated that the stiffness variations induced by the regulation of cellular contractility were mainly due to rearrangements of the contractile actin network on the dorsal surface. Taken together, our findings provide evidence that the actin cytoskeletal network and its contractility features provide and modulate the mechanical stability of adherent cells.

Actins↗

Quantification of the surface morphologies of lactose carriers and their effect on the in vitro deposition of salbutamol sulphate.

Application of the scanning probe microscopy technique for quantitative measurement of the surface roughness of lactose carriers was evaluated. The roughness values of four different lactose carriers were related to the in vitro deposition results of the drug, salbutamol sulphate. The rugosity values of the lactose carriers were represented by Ra values which were in the order of DCL-40>DCL-11>lactose 325M>lactose 200 M. In vitro deposition results using a twin impinger showed that rougher carrier surfaces generally allowed more drug particles to be emitted from the capsules and inhaler but the availability of the drug to stage 2 was reduced, as detachment of drug particles from the carrier surfaces was more hindered. There was an optimum Ra value for greater delivery of the drug particles to stage 2 of the twin impinger. A balance between adherence and detachment of the drug from the carrier surface was needed in order to optimize the delivery of a drug to the desired target sites using a dry powder inhaler.

Adrenergic beta-Agonists↗