PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monitoring, Physiologic”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Invasive and non-invasive physiological monitoring of blunt trauma patients in the early period after emergency admission.

Pulmonary artery catheterization is usually not available to critically injured patients before admission to the intensive care unit, where action to correct values derived from such monitoring may be too late. Methods allowing hemodynamic monitoring during the early stages after trauma need to be explored. We used non-invasive monitoring systems (bioimpedance cardiac output monitoring, pulse oximetry and transcutaneous oximetry) to evaluate early temporal hemodynamic patterns after blunt trauma, and compared these to invasive PA monitoring. We included prospectively 134 patients monitored shortly after admission to the emergency department. The non-invasive impedance cardiac output estimations under extenuating emergency conditions approximated those of the thermodilution method: r = 0.83, r2 = 0.69, P<0.001; bias and precision were -0.02+/-0.78 l/min/m2. In the intensive care unit, these values improved further to: r = 0.91, r2 = 0.83, P<0.001; bias and precision = 0.36+/-0.59 l/min/m2. Monitoring revealed episodes of hypotension, low cardiac index, arterial hemoglobin desaturation, low transcutaneous oxygen and high transcutaneous carbon dioxide tensions, and low oxygen consumption during initial resuscitation. Low flow and poor tissue perfusion were more pronounced in non-survivors by both methods. Multicomponent non-invasive monitoring systems give continuous on-line, real-time displays of physiological data that allow early recognition of circulatory dysfunction. Such systems provide information similar to that provided by the invasive thermodilution method, and are easier and safer to use.

Adult↗

[Measurement and estimation system for monitoring physiologic parameters of man and biological feedback training].

A flexible instrumental programmed system realizing the biological feedback (BFB) method and permitting an easy tuning of the channels and parameters for treatment and reflection of physiological information is designed. A measurement and estimation real-time medical system for monitoring and BFB training is described, based on visual programming. An example of practical clinical application of the system to BFB training for the EEG rhythms is offered.

Alcoholism↗

Application of multichannel near-infrared spectroscopic topography to physiological monitoring of the cortex during cortical mapping: technical case report.

BACKGROUND: Cortical stimulation via a subdural grid electrode (SGE) is one of the most reliable methods for identifying eloquent areas before surgery. However, the physiological conditions of the cortex during stimulation cannot be monitored electrophysiologically because of electrical artifacts. In the present case, we tested whether or not multichannel near-infrared spectroscopy (NIRS) topography, a noninvasive optical imaging technique, is applicable for monitoring the physiological conditions of the stimulated cortex. CASE DESCRIPTION: The patient (a 27-year-old right-handed man) suffered from glioma in the left frontal lobe. For preoperative cortical mapping, SGEs were implanted over the left motor cortex before tumor resection. Employing NIRS topography, we undertook 2 dimensional imaging of the changes in oxyhemoglobin (Oxy-Hb) and deoxyhemoglobin (Deoxy-Hb) concentration during electrical stimulation. Five-hertz stimulation with 5 mA at the left-hand area produced a localized increase in Oxy-Hb and a decrease in Deoxy-Hb, associated with slight twitching of the right hand. In contrast, 50-Hz stimulation produced significant increases in both Oxy-Hb and Deoxy-Hb at the stimulation site, and the area with such cerebral blood oxygenation (CBO) changes propagated beyond the hand area associated with prominent muscle contractions of the right upper extremity, suggesting that 50-Hz stimulation caused epileptic discharge. CONCLUSION: Near-infrared spectroscopy topography may represent a useful tool for imaging the degree and extent of the physiological effects of electrical stimulation on the cortex, and permits safe and accurate cortical mapping.

Adult↗

Multicomponent noninvasive physiologic monitoring of circulatory function.

A multicomponent noninvasive monitoring system for high-risk critically ill patients was developed and tested in a series of 58 high-risk surgical patients. The system was comprised of a thoracic electric bioimpedance (TEB) method for cardiac output estimation, laser-Doppler velocimeter for small vessel flow, transcutaneous oxygen (PtcO2) sensor for tissue oxygenation, pulse oximeter for arterial hemoglobin saturation (SaO2) and finger pressor sensor for arterial pressure. In a series of critically ill patients, this noninvasive system was compared with the widely used invasive monitoring system with systemic and pulmonary artery catheters. Despite theoretical limitations of TEB as a measure of cardiac output, there was a satisfactory correlation (r = .83) of cardiac output measured by thermodilution (TD) and TEB throughout a wide range of severe illnesses. Moreover, changes in TEB cardiac output satisfactorily tracked changes in TD cardiac output (r = .91). There was poor correlation between TD cardiac output and BP or heart rate. The incidence of abruptly changing physiologic patterns was observed with simultaneously monitored invasive and noninvasive systems. Descriptions were made of the central circulation, peripheral perfusion, and pulmonary function; common interactive responses of these circulations were also evaluated. Monitored events defined as abrupt reductions in these variables often occurred from reduced cardiac output, PtcO2 or PtcO2/PaO2 index, and infrequently from unanticipated reductions in SaO2. Recovery from the nadir of the monitored event was associated usually with improvements in flow, PtcO2, or both. Hemodynamic and oxygen transport patterns of a few commonly encountered patterns are described.

Adolescent↗

Continuous physiological monitoring: an integrated system for use in neonatal intensive care.

A general purpose, multi-channel digital data acquisition and analysis system (Amlab, Associative Measurements, Sydney) configured to collect and process physiological signals including electroencephalograph and blood pressure is described. Its advantages over analog and single-purpose instrumentation are discussed as is its potential, by the addition of transducers, to replace single-purpose instruments.

Electroencephalography↗

Intraoperative physiologic monitoring and management during hepatic lobectomy using the liver isolation-perfusion technic.

The high operative mortality of major hepatic resection for tumor can be improved by a technic of resection using complete vascular isolation and hypothermic perfusion of the liver. Complete clamping of the portal vein, vena cava, and hepatic artery was necessary and well tolerated. Major physiologic, biochemical, and coagulation changes, however, can occur with this technic that requires close monitoring by the anesthesiologist. With astute observation and prompt corrective measures when indicated, these changes can be minimized to enable a safe and smooth resection to be carried out.

Acid-Base Equilibrium↗

Metabonomics technologies and their applications in physiological monitoring, drug safety assessment and disease diagnosis.

In this review, metabonomics, a combination of data-rich analytical chemical measurements and chemometrics for profiling metabolism in complex systems, is described and its applications are reviewed. Metabonomics is typically carried out using biofluids or tissue samples. The relevance of the technique is reviewed in relation to other '-omics', and it is shown how the methods can be applied to physiological evaluation, drug safety assessment, characterization of genetically modified animal models of disease, diagnosis of human disease, and drug therapy monitoring. The different types of analytical data, mainly from nuclear magnetic resonance spectroscopy and mass spectrometry, are summarized. The outputs from a metabonomics study allow sample classification, for example according to phenotype, drug safety or disease diagnosis, and interpretation of the reasons for classification yields information on combination biomarkers of effect. Transcriptomic and metabonomic data is currently being further integrated into a holistic understanding of systems biology. An assessment of the possible future role and impact of metabonomics is presented.

Age Factors↗

Perspectives in physiological monitoring.

Clinical monitoring systems that have been developed in response to the need to acquire patient physiological data have only recently been accepted as standard equipment in the operating room, and burgeoned into the variety of sophisticated patient-monitoring equipment available today. This article traces the history of the recognition of the importance of physiological data in diagnosing and treating disease, the inclusion of the four vital signs on patient charts, and the first instrumental recording of these signs, all of which occurred before 1900. The earliest operating room monitoring system, which was not developed until the mid 1940s, is described.

Animals↗

Continuous glucose monitoring: physiologic and pathophysiologic significance.

Diabetes mellitus is a complex disorder of the energy metabolism. In the present paper, we have tried to illustrate the changes in the regulation of blood glucose levels encountered in the two main types of diabetes: Type 2 (T2DM) and Type 1 (T1DM) diabetes mellitus, compared with healthy, non-diabetic subjects. For this we used the MiniMed CGMS (Continuous Glucose Monitoring System) which allows the continuous in vivo blood glucose measurement over a 3-day period. The study group comprised 19 diabetic patients (14 T1DM and 5 T2DM cases) and 4 non-diabetic controls. The recording in normal subjects showed a glycemic variation between 46 and 118 mg/dl, suggesting the existence of a strong and efficient glycemic control mechanism. In T2DM patients, both on diet only or on oral antidiabetic treatment, the oscillation of blood glucose levels was significantly higher compared to that recorded in non-diabetic subjects. In T1DM patients with stable metabolic control blood glucose fluctuations were comparable with those recorded in long-term type 2 diabetic patients but the "mean" values of blood glucose over 72 hours were lower. The CGMS is a valuable tool in the detection of unrecognized hypoglycemic episodes and hyperglycemic postprandial peaks and allows the patient and the health care team to adjust the treatment regimen in order to improve glycemic control. From our point of view, the CGMS could offer valuable information for the knowledge of glycemic regulation in normal people and for the diabetogenic mechanisms in prediabetic IGT and IFG patients.

Adolescent↗

Monitoring physiological variables with membrane probes.

Membrane probes are implantable devices, which can be used to sample from the interstitial fluid of the tissues in which they are implanted. Two types of membrane probes, one based on microdialysis and the other on ultrafiltration, were developed and tested in vitro for the following analytes: sodium, potassium, chloride, glucose and lactate. These membrane probes were then implanted subcutaneously in rats and used to monitor changes in interstitial analytes during the head-down tilt model of microgravity.

Animals↗

Use of physiologic monitoring to predict outcome and to assist in clinical decisions in critically ill postoperative patients.

A predictive index based on cardiorespiratory-monitored values of an earlier series of postoperative critically ill patients was tested in prospective clinical trials and found to be reasonably accurate, sensitive, and specific. The hypothesis was tested that the median values of patients who survived life-threatening postoperative conditions, rather than the norms of unstressed, healthy volunteer subjects, constitute a first approximation to the optimal therapeutic goals for critically ill postoperative patients. In a prospective series of 223 consecutive, critically ill postoperative patients, normal values were used as the therapeutic goals of the control patients, whereas the median values of surviving patients were used as the goals of therapy for the protocol group. The clinical conditions of the protocol group were at least as severe as those of the control group, but the mortality was significantly less in the protocol group (12.5 percent) than in the control group (35 percent); the number of life-threatening complications were also greater in the control group. These data suggest that at least half and possibly as much as two thirds of postoperative deaths may be due to physiologic problems that can be identified, described, predicted, and prevented. Therapy for the critically ill patient should be defined by physiologic criteria, and administration of therapy should be monitored to attain prophylactically optimal physiologic goals rather than giving therapy after a deficiency has occurred to attain normal values.

Clinical Trials as Topic↗

Physiological monitoring of optically trapped cells: assessing the effects of confinement by 1064-nm laser tweezers using microfluorometry.

We report the results of microfluorometric measurements of physiological changes in optically trapped immotile Chinese hamster ovary cells (CHOs) and motile human sperm cells under continuous-wave (CW) and pulsed-mode trapping conditions at 1064 nm. The fluorescence spectra derived from the exogenous fluorescent probes laurdan, acridine orange, propidium iodide, and Snarf are used to assess the effects of optical confinement with respect to temperature, DNA structure, cell viability, and intracellular pH, respectively. In the latter three cases, fluorescence is excited via a two-photon process, using a CW laser trap as the fluorescence excitation source. An average temperature increase of < 0.1 +/- 0.30 degrees C/100 mW is measured for cells when held stationary with CW optical tweezers at powers of up to 400 mW. The same trapping conditions do not appear to alter DNA structure or cellular pH. In contrast, a pulsed 1064-nm laser trap (100-ns pulses at 40 microJ/pulse and average power of 40 mW) produced significant fluorescence spectral alterations in acridine orange, perhaps because of thermally induced DNA structural changes or laser-induced multiphoton processes. The techniques and results presented herein demonstrate the ability to perform in situ monitoring of cellular physiology during CW and pulsed laser trapping, and should prove useful in studying mechanisms by which optical tweezers and microbeams perturb metabolic function and cellular viability.

2-Naphthylamine↗

Noninvasive physiologic monitoring of high-risk surgical patients.

OBJECTIVES: To study the feasibility of multicomponent noninvasive monitoring, consisting of a new bioimpedance method for estimating cardiac output together with routine pulse oximetry and transcutaneous oximetry, and to compare physiologic data obtained noninvasively with hemodynamic and oxygen transport data obtained by standard invasive pulmonary artery thermodilution catheter to evaluate circulatory function in high-risk surgical patients. DESIGN: Prospective descriptive analysis of the time course of physiologic patterns in surgical patients. SETTING: University-run county hospital. PATIENTS: Seventy-one consecutively monitored, high-risk critically ill surgical patients in their perioperative period. OUTCOME MEASURES: Simultaneous measurements by invasive and noninvasive methods to describe and compare the temporal physiologic patterns of survivors and nonsurvivors. RESULTS: The new impedance cardiac output estimations closely approximated those of the thermodilution method (r = 0.82, P < .001). Episodes of hypotension, tachycardia, low cardiac index, arterial hemoglobin desaturation, low transcutaneous oximetry, reduced oxygen delivery, and low oxygen consumption occurred with both groups but were more pronounced in the nonsurvivors than in the survivors. Noninvasive monitoring provided information similar to that of the thermodilution method. Both approaches indicated low flow and poor tissue perfusion (oxygenation) that was worse in the nonsurvivors. CONCLUSIONS: The multicomponent noninvasive monitoring provides continuous online, real-time displays of physiologic data that allow immediate recognition of circulatory dysfunction as well as the means to titrate therapy to appropriate predetermined therapeutic goals. The noninvasive systems are easy to apply, safe, inexpensive, reasonably accurate, and cost-effective.

Adult↗

A portable system for monitoring physiological responses to hypoglycaemia.

Hypoglycaemia is the most common complication affecting people with Type 1 insulin dependent diabetes mellitus. Its onset is characterized by symptoms which include sweating, tremor, palpitations, loss of concentration and tiredness. As part of a research project to investigate the mechanisms of hypoglycaemia we have developed an ambulatory system to monitor and record pulsatile changes in blood flow, pulse interval, body temperature and skin impedance. The system uses a pocket computer (Atari Portfolio) to collect and store the data on a memory card. The analogue system consists of two thermocouples, an infrared photoplethysmograph and skin impedance monitoring circuit. To conserve power the system is programmed to make measurements for 2 min every 10 min: using this regimen over 16 h of data can be stored. Data collected during a spontaneous overnight hypoglycaemic episode are presented and also a comparison between continuous and intermittent data collection during a period of induced hypoglycaemia. The system is being used to investigate the physiological responses to hypoglycaemia but could easily be adapted for monitoring other physiological signals.

Arrhythmias, Cardiac↗