PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Respiratory Protective Devices”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Inhalation exposure of lead in brass foundry workers: the evaluation of the effectiveness of a powered air-purifying respirator and engineering controls.

The protection that a powered air-purifying respirator afforded to ladle and furnace attendants who were exposed to lead, copper and zinc fumes in a brass foundry was found by measuring metal levels at the lapel and at nose level inside the respirator. Respirator fit was evaluated by use of a hot-wire anemometer at the face/Tyvek seal interfaces, and at the exit of the respirator. Effective protection factors for lead ranged from 1.05 to 67. Ergonomic factors and engineering controls are also discussed.

Air Pollutants, Occupational↗

Effect of facial hair on the face seal of negative-pressure respirators.

The effect of facial hair on the face seal of negative-pressure respirators, both half-masks and full facepieces, has been investigated. Three hundred and seventy (370) male employees were fit tested both qualitatively and quantitatively. Of these, sixty-seven (67) had fully established beards varying in length, shape, density and texture. Bearded subjects consistently failed the qualitative fit test protocol. Quantitative fit testing with half-mask respirators indicated that bearded employees had a median fit factor of 12 (8% leakage). A median fit factor of 2950 (0.03% leakage) was obtained on clean-shaven employees. An average two hundred and forty-six (246) fold drop in protection was experienced by bearded employees. With full facepiece respirators, the bearded employees had a median fit factor of 30 (3% leakage). A median fit factor of greater than 10 000 (less than 0.01% leakage) was obtained on clean-shaven employees. At least a three hundred and thirty (330) fold drop in protection was experienced by bearded employees. Results indicate that the presence of a beard greatly increases the leakage through the respirator face seal, and this leakage should not be permitted when employees are required to wear respirators.

Face↗

Some observations on frequency of respirator fit tests.

Quantitative respirator fit tests were repeated with workers who had demonstrated adequate fit initially. As the interval between first and second tests increased, it was expected that the rate of failure (penetration of test aerosol greater than 1%) on the second test also would increase. No significant time relationship was demonstrated, but the results suggest that the opposite of our expectation occurred: failure rates decreased with longer time intervals. If confirmed, the results suggest a simple strategy for repeat fit testing.

Humans↗

Application of gas adsorption kinetics. I. A theoretical model for respirator cartridge service life.

Using the principles of gas adsorption kinetics, we have developed a new theoretical model addressing the adsorption and breakthrough of contaminant vapors or gases with respect to solid sorbents. Specifically, we have applied the theory to predict respirator cartridge service life in connection with individual contaminant exposure to toluene, vinyl chloride, ethyl acetate, and each of several different trichlorinated hydrocarbons at several levels of concentration. Theoretical expressions and contaminant breakthrough curves derived from our new approach are compared with those published previously by Mecklenburg and by Wheeler. The breakthrough curves derived by Mecklenburg and by Wheeler have approximately the same shape as the corresponding experimental curves for 0% to 40% breakthrough. However, these curves deviate in varying degrees from the experimental data at breakthrough values exceeding 40%. By contrast, our new theory agrees with published experimental results over the entire range of 0% to 100% breakthrough. The new model not only agrees with experimental observation, it is also less complicated and easier to apply to practical industrial hygiene problems than theories developed previously.

Adsorption↗

Application of gas adsorption kinetics--II. A theoretical model for respirator cartridge service life and its practical applications.

A previously introduced theoretical model addressing respirator cartridge contaminant breakthrough was further developed in this study. This development involved the introduction of a new theoretical parameter, a, to complement the parameters k' and tau employed in the initial theoretical approach. The extension of the theory permits the theoretical investigation of the following: (1) the effect of contaminant concentration on breakthrough time; (2) the effect of flow rate on breakthrough time; (3) the influence of contaminant concentration on percentage of breakthrough; and (4) the effect of contaminant concentration on the weight of adsorbed contaminant at a given time. We also compared new theoretical expressions with previously published empirical equations. Utilizing the parameter a, we derived a set of equations of significant practical value. These equations relate the ratio of two contaminant concentrations (one experimental reference concentration and any other concentration of interest) to either the ratio of the corresponding breakthrough times or the corresponding weights of adsorbed contaminant. Three practical examples are provided demonstrating that the new theoretical model reduces experimental work required to predict respirator cartridge service life.

Adsorption↗

Respirator evaluation for carbon setters with beards.

Studies of several types of disposable respirators were carried out in a prebake aluminum reduction plant to determine the protection factors associated with airborne particulates in the potroom environment. Seventy-five (75) individual tests of respirator performance were carried out on 60 different carbon setters during the actual carbon setting task. Acceptable performance was achieved with all types of respirators tested. There was no significant difference in respirator performance for employees with or without beards.

Aluminum↗

Workplace protection factor measurements on powered air-purifying respirators at a secondary lead smelter: results and discussion.

A study was conducted at a secondary lead smelter to evaluate the workplace performance of the 3M W-344 and Racal AH3 powered air-purifying respirators equipped with helmets and high efficiency filters. The research protocol developed for the study has been described in a companion paper. The results of the study indicate that the mean lead concentrations, measured inside the facepiece of both PAPRs, were significantly less than the OSHA lead exposure limit of 50 micrograms/m3. The means of the workplace protection factor measurements on both PAPRs were significantly less than the PAPR selection guide protection factor classification of 1000. Correlation analysis of preshift quantitative fit factors and corresponding workplace protection factors indicated no linear association between these two measures of performance. This finding suggests that for PAPRs equipped with helmets and high efficiency filters quantitative fit factors as presently determined are not indicative of the workplace protection which the respirators provide. Since the PAPR protection factor classification of 1000 was originally based on quantitative fit factors, the lack of a demonstrated association between quantitative fit factors and workplace protection as found in this study may explain why their performance was significantly less than expected.

Air Pollutants, Occupational↗

Effects of air temperatures and humidities on efficiencies and lifetimes of air-purifying chemical respirator cartridges tested against methyl iodide.

Methyl iodide penetration curves through three types of respirator cartridges and canisters were determined at several temperatures to identify the significance of temperatures of testing and use. Three charcoal types showed similar results: triethylenediamine (5% TEDA-impregnated, (2% TEDA + 5% KI3)-impregnated, and unimpregnated. Penetration curves were shifted at higher temperatures in the range 25-38 degrees C, keeping relative humidity constant in the range 50-70%, but allowing absolute humidities to increase correspondingly. These shifts were such that penetrations were increased and service lives were decreased significantly (4-15% per degrees C). At constant water vapor concentration, service life of the (2% TEDA + 5% KI3)-impregnated charcoal increased with temperature, illustrating the complexity of temperature effects. For one case (5% TEDA) using cartridges at humidity equilibrium, temperature and humidity effects were sorted out. Until these effects are better understood, air-purifying respirator cartridge and canister testing should be done at conditions more representative of possible use and at more closely controlled temperatures.

Humidity↗

Residence time model for respirator sorbent beds.

An experimental bed residence time model has been developed to characterize the performance of sorbent beds in removing gaseous contaminants. This model is applicable to both adsorption and chemisorption processes. The fundamental characteristics produced can be used to predict the performance of respirator cartridges and canisters over a wide range of operating conditions. A family of performance curves can be constructed for a specific product type for application in determining minimum service life and renewal frequency. This model is described in terms of a dynamic sorption concept, and is demonstrated using ASC I carbon and sulfur dioxide in air at concentrations of 500 ppm, 1000 ppm and 5000 ppm. Adsorption data is also provided for carbon tetrachloride. The effects of bed depth and superficial velocity reduce to a unique relationship between breakthrough time and bed residence time. The influences of moisture, concentration and heat transfer at the walls of the sorbent containment have all been investigated in this study. The dynamic sulfur dioxide capacity of ASC I carbon was found to increase significantly at increasing levels of adsorbed moisture for decreasing sulfur dioxide concentrations. The interrelation of moisture and concentration of sulfur dioxide produces a secondary removal mechanism for which the chemistry is briefly described.

Adsorption↗

Determination of organic vapor respirator cartridge variability in terms of degree of activation of the carbon and cartridge packing density.

The protection provided by carbon-containing organic vapor respirator cartridges depends in part on the packing density of the carbon in the cartridges and its degree of activation. Large variations in these parameters could have significant effects on the service-life of respirator cartridges. Variability among commercially available organic vapor respirator cartridges was examined with regard to the following characteristics: the particle size distribution, amount of carbon and packing density of the carbon in the cartridges and the degree of activation of the carbon. The degree of activation was determined by measuring the maximum adsorption space and the structural constant of the carbon. These two parameters--Wo (cm3/g) and k (cal/M)-2--are constants in the Dubinin/Radushkevich (D/R) model from which physical absorption onto microporous adsorbents, such as activated carbon, are described. Respirator cartridges from three different suppliers were examined. Significant variability (11-40%) in the amount and the degree of activation of the carbon occurred between cartridges of different manufacturers, as well as among cartridges of an individual manufacturer.

Carbon↗

The effect of temperature and humidity levels in a protective mask on user acceptability during exercise.

Subjective and physiological responses were obtained from six subjects wearing a ventilated face mask while exercising (3.8 met) for 15 min on a bicycle ergometer. Different combinations of ambient air temperatures (7 degrees, 16 degrees, 25 degrees C) and mask air temperatures (22 degrees, 27 degrees, 33 degrees C) were studied together with two different air humidities inside the mask (61% and 86% RH). Control experiments were performed without the mask at the same ambient temperatures. Skin temperatures, heart rates and skin wettedness were monitored during exercise. The subject's acceptance of the mask and thermal environment, thermal sensation, sensations of discomfort, sweating and skin wettedness, and their judgment of the work of breathing were assessed at the end of the 15 min exercise period. The acceptance of both the ambient thermal environment and of the thermal microclimate in the mask primarily was determined by the ambient air temperature, but it was influenced by the air temperature and humidity inside the mask. At ambient temperatures of 7 degrees C and 25 degrees C, the acceptance of the thermal work conditions decreased. In the warm environment a mask air temperature less than or equal to 27 degrees C was 100% acceptable and increased the acceptance of thermal environment. In the cool environment, a mask air temperature greater than or equal to 27 degrees C was 100% acceptable. The humidity content of the mask air was only important when the mask air was warm. Warm humid air significantly decreased acceptance of the mask conditions.

Adult↗

Performance of dust respirators with facial seal leaks: I. Experimental.

The ability of representative half-mask and single-use respirators with facial seal leaks to provide protection against aerosols was evaluated by experimental measurement. Respirators were mounted on a manikin in a test chamber and operated at seven steady flow rates over the range of 2 to 150 L/min. Samples of polydisperse and monodisperse aerosols were taken from inside and outside the respirator and analyzed by a calibrated optical particle counter over the particle-size range 0.1 to 11.3 microns. Measurements were made separately for filter performance as a function of particle size and flow rate, and simulated leak performance (penetration) as a function of particle size, pressure drop, and leak size. Flow rate vs. pressure drop measurements were made for all filters and leaks tested. For a given leak condition the percentage of the total flow traversing the leak varied several fold over the usual range of airflow rates through a respirator. Aerosol penetration was found to depend strongly on particle size and flow rate for filters, and to depend strongly on particle size and less strongly on pressure drop for leaks. One can conclude from these measurements that the aerosol-size distribution inside a respirator will nearly always be significantly different from that outside the respirator.

Aerosols↗

Performance of dust respirators with facial seal leaks: II. Predictive model.

A performance model for half-mask and single-use respirators is presented. It represents a possible alternative to field measurements of respirator performance. Experimental data on filter and leak performance given in Part I were used to develop a model that allows one to predict 1) the overall respirator penetration as a function of particle size for any work rate and 2) overall total mass penetration for any work rate and exposure aerosol-size distribution for a known respirator filter and facial seal leak condition. A simplified method based on general regression equations is presented that allows one to estimate these quantities based on QNFT (quantitative fit testing) measurements and a knowledge of the exposure aerosol-size distribution. Example calculations are given for a situation in which QNFT gives a fit factor of 50 for a half-mask with dust, fume and mist filter cartridges, but predicted protection factors for various use conditions range from 20 to 81 depending on exposure particle-size distribution and work rate of the wearer.

Aerosols↗

Particle size-dependent leakage and losses of aerosols in respirators.

Measuring particle size-dependent leakage into and losses inside a respirator reveals the deposition mechanisms occurring at the leak site and the flow dynamics inside the respirator. This study investigated particle size-dependent leakage and deposition within the mask by examining the leakage into the mask for different hole locations, probe locations, hole shapes, hole lengths and hole sizes. The shape of the leak has an effect on particle size-dependent leakage. Probe and leak location tests indicated that not only does the total measured leakage change but also the size-dependence of the leakage changes depending on the leak and probe locations. When the leak site is in the chin area, the clean air entering through the filters at the chin helps to carry the inward leakage into the breathing zone. Particle size-dependent leakage does occur and is due to both inertial entry losses at the leak site and within the mask, and diffusional losses within the mask and leak site. Particle size-dependent curves change shape as the hole size changes with relatively more larger particles entering through the small hole size.

Aerosols↗

The effect of aerosol size distribution and measurement method on respirator fit.

The particle size-dependent leakage into a respirator was examined by measuring the leakage of particle sizes between 0.07 to 4.4 microns through three hole sizes in a negative-pressure half-mask respirator worn by a human subject. This investigation showed that the size distribution of an aerosol test agent and the measurement method have an effect on the leakage measured in a quantitative fit test. For instance, the ratio of percent leakage measured by light scattering between test aerosols with count median diameters of 2.2 and 0.28 microns can be as large at 5:1. Likewise, the ratio of the percent leakage measured by a particle count method vs. a mass method of detection of the same polydisperse aerosol with a count median diameter equal to 2.2 microns can be as high as 4:1. The mass leakage into a mask with a leak is also greater for an exposure aerosol with a count median diameter between 0.15 to 0.30 micron compared to exposure aerosols with larger count median diameters for aerosols with the same mass concentration.

Aerosols↗

Facial hair and respirator fit: a review of the literature.

The effect of facial hair on the quality of fit obtained while wearing a tight-fitting respirator has been and continues to be a controversial subject. Many people hold strong opinions on both sides of the issue, but it is not opinion that is needed. Rather what is needed is quantitative study of the situation to determine precisely what effect facial hair has on respirator fit. The results of fourteen studies of the facial hair leakage question have been summarized. All but two of the fourteen studies found that in the presence of facial hair, face seal leakage increases from 20 times to 1000 times. In addition both intersubject and interrespirator face seal leakage variability increased when facial hair was present. In the other two studies, one completed with positive pressure SCBAs and the other completed in the workplace, no statistically significant leakage differences were found.

Equipment Failure↗

Penetration of respirator filters by an asbestos aerosol.

Five models of respirator filters were challenged with a chrysotile aerosol, and the asbestos fiber penetration of the media was measured in five experimental series simulating different environmental conditions. Penetration of the facial seal was not evaluated. The penetration of each filter was determined from the ratio of the downstream to upstream concentrations of airborne asbestos fibers as measured by the standard National Institute for Occupational Safety and Health (NIOSH) asbestos fiber counting method P&CAM 239. Penetrations measured in this project and presented are indicative of penetrations of filters used a) fresh from the package, b) after exposure to an organic oil mist, c) after storage at high humidity at room and elevated temperatures, and d) after preexposure to water mist. Penetrations varied between less than 0.1% and 2.7% for filters tested fresh from the package and up to 18% after exposure to simulated field/environmental conditions. The data indicate that each of the filter models tested, except for the high efficiency filter, was affected adversely to some degree by one or more of the simulated field/environmental conditions.

Aerosols↗

Physical performance during combinations of hypercapnic, resistive, and hot air breathing.

Performance time for a 3.2-km (2-mi) run at maximal voluntary speed was determined for 12 subjects under seven experimental conditions: resistance breathing (R), hypercapnia (C), hot air breathing (H), and combinations R + C, R + H, H + C, and R + H + C. The tests were performed on a treadmill at 5% grade. Performance time was increased significantly when the subjects were exposed to resistance breathing alone (9%) or to any combination condition containing resistance (16%-31%). The effect of breathing resistance was not specific to the presence or absence of C, H, or their combination. Nevertheless, the physiological effects were not additive and could not be predicted by knowing the effects of the individual stresses. Performance time also was increased in Condition H + C (9%). Pulmonary ventilation was the most affected physiological variable, significantly reduced in Conditions R, H, C + R, H + R, and H + C + R. In conclusion, a multistress approach should be used when determining physiological responses or performance limitations brought about by real or simulated industrial respirator-wear conditions.

Adult↗