PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “SPECIFIC GRAVITY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Decreases in urine specific gravity and urinary creatinine in elderly women.

OBJECTIVE: To examine the effects of aging on urinary levels of creatinine (CR) and urine specific gravity (SG) among women in a large-scale epidemiology survey. METHODS: Data on CR and SG in urine, together with smoking habits and menopausal status, were selected from previously established databases and combined with the results of supplemental sample collection. In total, CR and SG data were available for 11,090 never-smoking women (total group; 29-80 years of age); a subgroup of 1,851 women who lived in Kyoto was also selected from the total group. Data from the two groups were subjected to statistical analyses. In statistical evaluation, SG was converted to factor G, which was defined as (SG-1.000)x1,000. RESULTS: Classification by decade of years of age showed that both CR and SG decreased steadily as a function of advancement in age over 30 years, both in the total group and in the Kyoto subgroup, showing high reproducibility of the observation on a whole-country basis and on a local basis. When the levels at 80 years of age were compared with those at 30 years, there was an approximately 60% and 30% decrease in CR and factor G, respectively. Thus, the effects of aging were more marked on CR than on factor G (and therefore on SG). Menopause appeared to be an influential factor in the reduction of CR and SG, separately from aging itself. CONCLUSIONS: Urinary levels of creatinine and, to a lesser extent, urine specific gravity, steadily decreased as a function of ages of over 30 years in women.

Adult↗

Effects of different short-term dietary phosphorus levels on egg specific gravity and blood phosphorus of hens.

In the first 2 experiments, laying hens were fed a diet containing .30% phosphorus for a preliminary period of 3 days. At the beginning of the experimental period, hens were fed .30, .75, or 1.40% phosphorus with 3.50% calcium. Another group of hens was fed .75% phosphorus and 1.40% calcium. Specific gravity of the eggs and blood serum inorganic phosphorus were determined and compared with those from control hens continuously fed a diet containing .75% phosphorus and 3.50% calcium. Both high phosphorus and/or low calcium decreased the specific gravity of eggs and increased the serum phosphorus level. In experiment 2, hens were fed different levels of phosphorus at different times of the day. Birds receiving 1.40% phosphorus between 0700 and 0930 hr and .30% phosphorus between 0930 and 2000 hr (Treatment 2) laid eggs with higher specific gravity than hens fed .30% phosphorus between 0700 and 0930 hr and 1.40% phosphorus between 0930 and 2000 hr (Treatment 3). there was no further improvement in egg shell quality over that from hens fed .75% phosphorus for both time periods (0700 to 2000 hr). In both experiments it was apparent that the dietary phosphorus level affected egg shell quality.

Animals↗

Effects of storage time and temperature on pH, specific gravity, and crystal formation in urine samples from dogs and cats.

OBJECTIVE: To determine effects of storage temperature and time on pH and specific gravity of and number and size of crystals in urine samples from dogs and cats. DESIGN: Randomized complete block design. ANIMALS: 31 dogs and 8 cats. PROCEDURE: Aliquots of each urine sample were analyzed within 60 minutes of collection or after storage at room or refrigeration temperatures (20 vs 6 degrees C [68 vs 43 degrees F]) for 6 or 24 hours. RESULTS: Crystals formed in samples from 11 of 39 (28%) animals. Calcium oxalate (CaOx) crystals formed in vitro in samples from 1 cat and 8 dogs. Magnesium ammonium phosphate (MAP) crystals formed in vitro in samples from 2 dogs. Compared with aliquots stored at room temperature, refrigeration increased the number and size of crystals that formed in vitro; however, the increase in number and size of MAP crystals in stored urine samples was not significant. Increased storage time and decreased storage temperature were associated with a significant increase in number of CaOx crystals formed. Greater numbers of crystals formed in urine aliquots stored for 24 hours than in aliquots stored for 6 hours. Storage time and temperature did not have a significant effect on pH or specific gravity. CONCLUSIONS AND CLINICAL RELEVANCE: Urine samples should be analyzed within 60 minutes of collection to minimize temperature- and time-dependent effects on in vitro crystal formation. Presence of crystals observed in stored samples should be validated by reevaluation of fresh urine.

Animals↗

The clinical refractometer: a useful tool for the determination of specific gravity and osmolality in canine urine.

For the determination of specific gravity of canine urine the urinometer is often used. An alternative method is based on refractometry. Both methods were compared and a table for converting refractometer values to urinometer values is given. The refractometer was also compared with an osmometer. A linear relation was found between the readings of both instruments. The results clearly indicate that the refractometric method is very suitable for the small animal practitioner. The instrument appears to be a good alternative for both the urinometer and the osmometer.

Animals↗

Comparison of specific gravity and creatinine for normalizing urinary reproductive hormone concentrations.

BACKGROUND: Specific gravity (SG) may perform as well as creatinine (CR) correction for adjusting urinary hormone concentrations, as well as offer some advantages. We compared the two methods and applied them to US and Bangladeshi specimens to evaluate their use in different populations. METHODS: Pearson correlations between serum concentrations and SG, CR, and uncorrected urinary concentrations were compared using paired daily urine and serum specimens from one menstrual cycle from 30 US women. Corrected urinary estrone conjugate and pregnanediol glucuronide concentrations were compared with serum estradiol and progesterone. Urine specimens across one menstrual cycle from 13 Bangladeshi women were used to evaluate the applicability of both methods to a nonindustrialized population. Linear mixed-effects models were used to compare CR and SG values in the Bangladeshi vs US specimens. RESULTS: There was no significant difference between SG-corrected vs serum and CR-corrected vs serum correlations for either assay. Usable CR results were obtained for all US specimens, but 37% of the Bangladeshi specimens were below the CR assay limit of detection. The Bangladeshi sample had significantly lower CR and higher inter- and intrasubject CR variability than the US sample. CONCLUSIONS: SG is a potentially useful alternative to CR correction for normalizing urinary steroid hormone concentrations, particularly in settings where CR values are highly variable or unusually low.

Adult↗

Reactivity differences among human T cells from blood and lymphoid organs, analysed by limiting dilution: correlation with specific gravity and binding of peanut lectin.

Human T cells from peripheral blood, cord blood, thymus, spleen and lymph node were analysed for their proliferative response capacity to mitogens, for their specific gravity and size, and for their binding capacity of peanut agglutinin. A close correlation was found between these parameters: thymocytes and T cells from spleen were consistently heavier and smaller, and showed a lower proliferative response capacity, than T cells from blood or lymph node. Similarly, within each cell population, the small, heavy cells were least reactive. The limiting-dilution analysis revealed that heavy T cells from peripheral blood contain a lower number of reactive cells than the light peripheral T lymphocytes. Because heavy T cells from the thymus bound more peanut lectin than did light cells, it is speculated that the differences between T cells of high and low specific gravity might reflect differences in maturation level.

Adult↗

Identification of quantitative trait loci influencing wood specific gravity in an outbred pedigree of loblolly pine.

We report the identification of quantitative trait loci (QTL) influencing wood specific gravity (WSG) in an outbred pedigree of loblolly pine (Pinus taeda L.). QTL mapping in an outcrossing species is complicated by the presence of multiple alleles (> 2) at QTL and marker loci. Multiple alleles at QTL allow the examination of interaction among alleles at QTL (deviation from additive gene action). Restriction fragment length polymorphism (RFLP) marker genotypes and wood specific gravity phenotypes were determined for 177 progeny. Two RFLP linkage maps were constructed, representing maternal and paternal parent gamete segregations as inferred from diploid progeny RFLP genotypes. RFLP loci segregating for multiple alleles were vital for aligning the two maps. Each RFLP locus was assayed for cosegregation with WSG QTL using analysis of variance (ANOVA). Five regions of the genome contained one or more RFLP loci showing differences in mean WSG at or below the P = 0.05 level for progeny as grouped by RFLP genotype. One region contained a marker locus (S6a) whose QTL-associated effects were highly significant (P > 0.0002). Marker S6a segregated for multiple alleles, a prerequisite for determining the number of alleles segregating at the linked QTL and analyzing the interactions among QTL alleles. The QTL associated with marker S6a appeared to be segregating for multiple alleles which interacted with each other and with environments. No evidence for digenic epistasis was found among the five QTL.

Alleles↗

Specific gravity and osmolality as measures of urine concentration in the calf.

Specific gravity and osmolality were determined for daily urine output from 8 male calves that developed diarrhoea. Both factors increased significantly during diarrhoea. From the correlation (r = 0.724) between them and the range of predicted osmolality values for any particular SG the use of osmolality was confirmed as a precise measure of urine concentration in the calf.

Animals↗

Problems concerning the usefulness of adjustment of urinary cadmium for creatinine and specific gravity.

A previous study concluded that there are some doubts as to the validity of creatinine as a parameter for adjusting the values of biological indicators determined on spot samples of urine, since it is subject to marked inter- and intraindividual variations. Furthermore, since there was only a moderate correlation between creatinine levels and specific density, it can be assumed that these two parameters cannot be used indifferently for adjustment. Nevertheless, it seemed advisable to verify whether correction of cadmium values determined from spot samples offers any practical advantages. For this purpose, 105 subjects with occupational exposure to cadmium were examined. They collected their 24-h urine and spot samples separately at 8.00 h. There was a close correlation between CdU/spot samples and CdU/24 h. The correlation index was very similar both for CdU/spot values expressed in microgram/l and for values adjusted according to creatinine or 1024 specific gravity. These results show that no particular advantages are offered by adjusting CdU according to creatinine or specific gravity.

Adult↗

A relationship between urine specific gravity and hyponatremia in hospitalized schizophrenic patients.

The relationship between urine specific gravity (USG) and the incidence of polydipsia/hyponatremia in hospitalized schizophrenic patients was examined. On the basis of five independent USG values, we identified 49% (35 out of 72) of male and 22% (8 out of 37) of female patients with hyposthenuria (mean USG < or = 1.008). Review of 2 years of records of routine laboratory examinations identified 12 males with hyponatremia, 11 males with borderline hyponatremia, and 49 males with normal values; among female patients, only one patient with hyponatremia and three patients with borderline values were identified. A significantly lower mean USG (1.003 +/- 0.001) for the male patients with hyponatremia compared with the male patients with normal serum sodium data (1.011 +/- 0.005) was observed. All of the male patients with hyponatremia, as well as 18 of the 49 male patients with normal serum sodium values, exhibited hyposthenuria. The USG values of all the patients with hyponatremia were consistently quite low (< or = 1.005), whereas 14 of the 18 normonatremia/hyposthenuria patients had normal USG values (i.e. > or = 1.009) in at least one of five determinations; the mean USG values for most (16 of 18) of the normonatremia/hyposthenuria patients ranged from 1.006 to 1.008. Thus, many hospitalized schizophrenic patients exhibit hyposthenuria of varying degrees, but consistently low USG values are most suggestive of the risk of polydipsia/hyponatremia.

Adult↗

A preliminary evaluation of the interaction between urine specific gravity and leukocyte esterase results using Bayer Multistix and the Clinitek 500.

OBJECTIVES: To determine the sensitivity of the leukocyte esterase (LE) pad to predict microscopically quantified white blood cells in urine sediment and to assess the interaction of urine specific gravity (SG) on leukocyte esterase sensitivity. METHODS: Microscopic quantification of white blood cells in urine sediment was performed manually and automated chemical urinalysis was performed using the Bayer Clinitek 500 and Multistix 8 SG strips on 422 random urine specimens. RESULTS: The sensitivity of the leukocyte esterase pad to predict white blood cells in centrifuged urine was 58% (61/106). There was a weak but statistically significant negative correlation between SG and LE pad performance, r = -0.12, p < 0.05. CONCLUSIONS: The 58% sensitivity of the Multistix leukocyte esterase detection of white blood cells in urine sediment was consistent with previous reports. The negative correlation of specific gravity and leukocyte esterase provides partial explanation for the lack of sensitivity of the leukocyte esterase test.

Adolescent↗

Serial measurements of CT attenuation and specific gravity in experimental cerebral edema.

Vasogenic cerebral edema was induced cryogenically in rhesus monkeys. Serial scans in both axial and coronal planes were used to study the onset, peak, and regression of edema. Progression of edema, predominantly involving the white matter, was analyzed from the postmortem distribution of a blood/brain barrier indicator (Evans blue) injected at surgery. Specific gravity was measured in fresh, unfixed specimens from both the edematous and normal hemispheres and correlated with corresponding CT attenuation values obtained before death. The drop in specific gravity closely corresponded to the decrease in CT attenuation.

Animals↗

The role of cerebral blood volume changes in brain specific-gravity measurements.

Cerebral blood volume (CBV) was calculated in gerbils from specific-gravity (SG) changes between normal and saline-perfused brains. Furthermore, changes in CBV were investigated during ischemia using carbon-14-labeled dextran (MW 70,000) as an intravascular marker. Both data were used to evaluate the possible error due to a change in CBV on the measurement of ischemic brain edema by the SG method. The methodological error found was 0.0004 for a 100% CBV change. This error is insignificant, being less than the standard deviation in the SG measured for the gerbil cortex (SG 1.0494 +/- 0.0006). Thus, CBV changes are not responsible for the SG variations observed during the first phase of ischemia. These variations are better explained as an increase of brain water content during ischemia.

Animals↗

Passage of indigestible particles of various specific gravities in sheep and goats.

1. Eight kinds of indigestible particles with specific gravities (SG) ranging from 0.92 to 1.87 (2 mm diameter and 4 mm length) were injected into the reticulo-rumen of sheep and goats in order to investigate the relation between SG and passage through the gastrointestinal tract, and the difference in passage time in the two species of animals. 2. The percentage of excreted particles significantly increased, while the percentage of ruminated particles in the excreted particles significantly decreased, as the SG increased. 3. The daily and cumulative recovery rates of particles of SG 1.38 were slower in sheep than in goats, while those with SG 0.92 were not different between species. 4. It is concluded that particles with SG higher than 1.27 would pass through the gastrointestinal tract of sheep and goats more quickly than those with SG lower than 1.21.

Animals↗

A reagent strip for measuring the specific gravity of urine.

A solid-phase reagent for determination of urinary specific gravity (relative density) is described. This reagent strip, similar to others in the "N-Multistix" series (Ames), contains a polyacid whose acidity is sensitive to the ionic concentration in the urine in which it is immersed. As the acidity of the polyacid changes, pH changes are detected by a pH indicator within the reagent strip. In comparison studies, 84.4% of relative densities as measured with these reagent strips were within 0.005 of the corresponding results with a total-solids meter, and 89.9% were within 0.005 of the corresponding urinometer results. Adding a correction of +0.005 to the reagent-strip results for urines with high pH increased the percentage of results within 0.005 of the comparison method to 90.7% (TS meter) and 92.9% (urinometer). Lot-to-lot variability and reader-to-reader variability were both low. Reagent strip results are not affected by glucose, may be increased by albumin, and correlate with urea concentrations.

Equipment and Supplies↗

Experimental evaluation of perfluorophenanthrene as a high specific gravity vitreous substitute: a preliminary report.

Perfluorophenanthrene, a liquid fluorocarbon with a specific gravity approximately twice that of water, potentially offers certain advantages as a vitreous substitute in vitreoretinal surgery. To determine its efficacy and safety we first purified it by chemical methods used in the preparation of experimental blood substitutes to a level at which it was not at all or only minimally toxic to culture-grown retinoblastoma cells. Nineteen of 22 vitrectomized eyes of white New Zealand rabbits injected with this purified perfluorophenanthrene showed satisfactory clinical tolerance. Light and electron microscopy showed minimal or no toxic effects in the 19 eyes, although uptake of perfluorophenanthrene by some preretinal cells was observed 28 days after implantation. Postoperative light-adapted electroretinography recordings of eight of the injected eyes showed no significant change. Perfluorophenanthrene injected into the anterior chamber of the rabbit eyes had toxic effects on the cornea. If further experimentations confirm our findings, perfluorophenanthrene may be a suitable transparent high-density liquid for temporary use in surgery to repair retinal detachments.

Animals↗

Nondestructive discrimination of ivories and prediction of their specific gravity by Fourier-transform Raman spectroscopy and chemometrics.

Fourier-transform (FF) Raman spectroscopy and chemometrics were used for nondestructive analysis of ivories. The discrimination of five kinds of ivories, two subspecies of African elephant, mammoth, hippopotamus, and sperm whale, was investigated, and a calibration model for predicting their specific gravity was developed. FT-Raman spectra were measured in situ for them and chemometrics analyses were carried out for the 3050-350 cm(-1) region. The five kinds of ivories were clearly discriminated from each other on the scores plots of two or three principal components (PCs) obtained by principal component analysis (PCA). The loadings plot for PC 1 shows that the discrimination relies on the content ratio of organic collagenous protein and inorganic hydroxyapatite of ivories. The loadings plot for PC 2 shows that bands due to the CH3 and CH2 stretching modes of the protein also play a role in the discrimination. Using partial least squares regression (PLSR), we developed a calibration model that predicts the specific gravity of the ivories from the FT-Raman spectra. The correlation coefficient and root mean square error of cross validation (RMSECV) of this model were 0.980 and 0.024, respectively.

Animals↗

Relationships of total protein, specific gravity, viscosity, refractive index and latex agglutination to immunoglobulin G concentration in mare colostrum.

A colostrum sample was collected within 24 h after foaling from 27 mares and from 10 other mares a milk sample was collected several weeks post partum. Immunoglobulin G concentrations were determined quantitatively by radial immunodiffusion and semi-quantitatively using a commercial latex agglutination test. Total protein, specific gravity, viscosity and refractive index were determined and their relationships to the immunoglobulin G concentration analysed. All parameters correlated with the immunoglobulin G concentration. The latex agglutination test divided the colostrum samples into three groups with different means for immunoglobulin G and total protein concentrations. Specific gravity and the latex agglutination test were found to be the methods best suited for on-farm evaluation of colostrum quality.

Animals↗