Diagnostic value of computer analysis of multipeaked EMG spikes.

Computer analysis of absolute number of peaks per second and the number of peaks in the multipeaked spikes/sec was carried out in the EMG interference recordings of 5 healthy, 6 myopathic and 8 neuropathic subjects. The purpose of the study was to detect diagnostically different patterns. A spike was considered multipeaked if it had 6 or more peaks. The amplitude of elimination (baseline) was examined at 1: 5, 1: 10 and 1: 15 of the average amplitude per second. Both the number of peaks and the number of peaks in multipeaked spikes in the neuropathic and myopathic muscles showed statistically significant differences when compared to healthy muscles. This technique could give an indication for the differential diagnosis of myopathic, neuropathic or healthy state of the muscle.

Arm

[Visual and computer evaluation of diazepam-induced EEG changes in epilepsy for localization of epileptogenic lesion].

Diazepam-induced EEG changes were analyzed both visually and by computer in epilepsy for localization of epileptogenic lesion. The results demonstrated that changes in beta spectral were diminished in 11/24 or 15/25 cases, but regionally increased in 3/24 or 3/25 patients overlying the epileptogenic lesion or area of EEG abnormalities. Diazepam-induced delta spectral power was usually increased (9/24), but occasionally focally reduced (3/24) over the lesion. The percentage of positive findings for localization was 38% with visual analysis and 46% with spectral analysis in beta spectral power, 38% in delta spectral power, and 67% with the analysis in combined beta with delta, and 83% with four independent tests. Spectral analysis was more sensitive than visual analysis, and it was a useful supplement to visual analysis, to general EEG evaluation, and to CT. Finally, the study emphasized that a localizing diagnosis to define the epileptogenic lesion should be based on the combination of a multitude of independent tests.

Adolescent

The effects of ethanol on human sleep EEG power spectra differ from those of benzodiazepine receptor agonists.

A single dose of ethanol (0.60 g/kg of body weight) was administered to eight young healthy male subjects 35 minutes before bedtime. Compared to the average value of two baseline nights, subjective sleep and polysomnographically determined sleep parameters were not significantly affected. In the first 2 hours of sleep after ethanol intake, the combined value of wakefulness, stage 1, and movement time was reduced. In this interval, visually scored stage 4 sleep was increased, and electroencephalographic (EEG) power density in nonrapid-eye-movement (nonREM) sleep was enhanced in the lowest delta frequencies and reduced in the beta range. Computed for the entire sleep episode, power density in REM sleep was enhanced in some theta frequencies. In the sleep episode initiated 24 hours after ethanol intake, power density in nonREM and REM sleep was enhanced in delta and theta frequencies, and the subjectively perceived number of awakenings was reduced. The effects of ethanol on EEG power spectra during sleep differ from those published for benzodiazepine and nonbenzodiazepine hypnotics. This indicates that the effects of ethanol on the human sleep EEG are not mediated by the benzodiazepine receptor.

Adult

[An electrophysiological analysis of brain maturation in chicken embryogenesis].

Studies have been made on the development of the spontaneous bioelectrical activity in the brain of 13-21-day chick embryos and on the reactions of the brain to sonic and photic stimulation (single and rhythmic). It was shown that the onset of the evoked responses to afferent stimulation coincides with predominance of a periodic process in the bioelectrical activity (17-18th days of embryogenesis). The presence of ordered rhythmicity in the bioelectrical activity of the brain which coincides with a possibility of its transformation and synchronization with afferent stimuli is suggested to be an important index of the development of the brain.

Acoustic Stimulation

Object-orientated DBMS techniques for time-oriented medical record.

In implementing time-orientated medical record (TOMR) management systems, use of a relational model played a big role. Many applications have been developed to extend query and data manipulation languages to temporal aspects of information. Our experience in developing TOMR revealed some deficiencies inside the relational model, such as: (a) abstract data type definition; (b) unified view of data, at a programming level; (c) management of temporal data; (d) management of signals and images. We identified some first topics to face by an object-orientated approach to database design. This paper describes the first steps in designing and implementing a TOMR by an object-orientated DBMS.

Algorithms

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Localization of a sequence motif complementary to the nuclear localization signal in proteasomes from Thermoplasma acidophilum by immunoelectron microscopy.

A sequence motif complementary to the nuclear localization signal (NLS) has been localized in proteasomes from Thermoplasma acidophilum by immunoelectron microscopy using sequence-specific antibodies. The antibodies were generated in two different ways: by immunization with a carrier-coupled peptide and by isolation of the sequence-specific antibody from an immune serum against native proteasomes using a peptide-affinity column. The sequence specificity of the isolated antibody was confirmed by a PEPSCAN-ELISA performed on overlapping nonapeptides deduced from the sequence of the alpha-subunit of the Thermoplasma proteasome. Compared to the antibody induced by the carrier-coupled peptide this antibody fraction showed a much higher affinity for native proteasomes. The attachment site of the Fab portion of the antibody to the proteasome was mapped by electron microscopy in conjunction with image processing. The antibody was found to bind to the periphery of the two outer "disks" of the proteasome complex formed by the alpha-subunits.

Amino Acid Sequence

Suggested minimum performance characteristics of data acquisition instrumentation in computer-assisted ECG processing systems.

The increasing importance of electrocardiogram (ECG) interpretation by computers warrants consideration of the specific technical requirements for ECG recorders used in computer-assisted ECG interpretation systems. An almost uniform characteristic of these devices is their capability to transmit the ECG signal over common carrier lines. This paper suggests minimum performance characteristics for the different components of a teletransmitting ECG recorder to facilitate the use and evaluation of computer-assisted interpretation systems. Considered are the need for signal fidelity, features for automatic quality control, and features for patient and technician safety. The performance characteristics for the ECG amplifier are only stated where they exceed the most recent recommendations of the Committee on Electrocardiography, American Heart Association. The features of the teletransmission section are based on a widely used mode and format of transmission.

Amplifiers, Electronic

Atrial electrogram monitoring in a cardiac care unit.

Routine monitoring of a bipolar atrial electrogram (AEG) simultaneously with the electrocardiogram is a useful and safe clinical technique for the diagnosis of complex cardiac dysrhythmias. The large-amplitude A waves of the AEG can be more reliably identified than the corresponding low-amplitude p waves of the electrocardiogram. Epicardial wires placed during cardiac surgery, catheter-mounted endocardial electrodes, and esophageal electrodes can all be used for routine AEG monitoring. A multipurpose pulmonary arterial catheter with a pair of electrodes, and esophageal electrodes can all be used for routine AEG monitoring. A multipurpose pulmonary arterial catheter with a pair of electrodes mounted on the proximal shaft can be used for combined AEG and hemodynamic monitoring. The equipment needed for AEG monitoring and recording consists of an additional bedside amplifier with 12- to 100-Hz band-pass filter, a dual-channel display scope, and a dual-channel strip chart recorder. Care must be used to keep the atrial electrodes electrically isolated for patient safety. In addition to enhancing the diagnosis and management of dysrhythmias, recording an AEG provides a signal that is suitable for automatic processing.

Arrhythmias, Cardiac

Epigenetically regulated digital signaling defines epithelial innate immunity at the tissue level.

To prevent damage to the host or its commensal microbiota, epithelial tissues must match the intensity of the immune response to the severity of a biological threat. Toll-like receptors allow epithelial cells to identify microbe associated molecular patterns. However, the mechanisms that mitigate biological noise in single cells to ensure quantitatively appropriate responses remain unclear. Here we address this question using single cell and single molecule approaches in mammary epithelial cells and primary organoids. We find that epithelial tissues respond to bacterial microbe associated molecular patterns by activating a subset of cells in an all-or-nothing (i.e. digital) manner. The maximum fraction of responsive cells is regulated by a bimodal epigenetic switch that licenses the TLR2 promoter for transcription across multiple generations. This mechanism confers a flexible memory of inflammatory events as well as unique spatio-temporal control of epithelial tissue-level immune responses. We propose that epigenetic licensing in individual cells allows for long-term, quantitative fine-tuning of population-level responses.

Animals

International standard (C.C.I.T.T.) for transmitting biomedical analogue and digital data on the public telephone network.

Analogue transmission of biomedical signals over the public telephone network has advantages from the economic point of view over digitalized transmission. This paper deals with the special problems encountered with the transmission of biomedical signals. Furthermore, the new international transmission standard C.C.I.T.T. recommendation V. 16 is introduced. This standard has recently been adopted by the relevant study group and has been presented to the Plenary Assembly of the C.C.I.T.T. for final approval. This standard is compatible with the existing public telephone networks. The technical specifications of this standard allow the transmission of the three-channel ECG for diagnostic purposes, e.g., remote processing and computer-assisted evaluation, as well as the transmission of the one-channel ECG with acoustic coupling, e.g., in emergency cases and for pace maker monitoring.

Analog-Digital Conversion

Intercellular calcium signaling via gap junctions in glioma cells.

Calcium signaling in C6 glioma cells in culture was examined with digital fluorescence video microscopy. C6 cells express low levels of the gap junction protein connexin43 and have correspondingly weak gap junctional communication as evidenced by dye coupling (Naus, C. C. G., J. F. Bechberger, S. Caveney, and J. X. Wilson. 1991. Neurosci. Lett. 126:33-36). Transfection of C6 cells with the cDNA encoding connexin43 resulted in clones with increased expression of connexin43 mRNA and protein and increased dye coupling, as well as markedly reduced rates of proliferation (Zhu, D., S. Caveney, G. M. Kidder, and C. C. Naus. 1991. Proc. Natl. Acad. Sci. USA. 88:1883-1887; Naus, C. C. G., D. Zhu, S. Todd, and G. M. Kidder. 1992. Cell Mol. Neurobiol. 12:163-175). Mechanical stimulation of a single cell in a culture of non-transfected C6 cells induced a wave of increased intracellular calcium concentration ([Ca2+]i) that showed little or no communication to adjacent cells. By contrast, mechanical stimulation of a single cell in cultures of C6 clones expressing transfected connexin43 cDNA induced a Ca2+ wave that was communicated to multiple surrounding cells, and the extent of communication was proportional to the level of expression of the connexin43 cDNA. These results provide direct evidence that intercellular Ca2+ signaling occurs via gap junctions. Ca2+ signaling through gap junctions may provide a means for the coordinated regulation of cellular function, including cell growth and differentiation.

Calcium

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts

[Universal measurement site for the processing-oriented recording of cardiovascular data].

A measuring place is described for the registration of standardized, evaluable by means of the computer deviations of bioelectric signals (parameters of heart and circulation, peripheral pulse curves and rheogramms). The high demands which concern the adequate establishment measuring places with regard to quality and comfort of attendance and condition corresponding technical solutions are explained. At the instance of the rheogram the mode of function is described. A short prognosis on the trend of development in the recognition of biological measuring values is given.

Cardiovascular Diseases

Quantitation and mapping of integrated human papillomavirus on human metaphase chromosomes using a fluorescence microscope imaging system.

Integrated human papillomavirus type 16 (HPV-16) DNA was directly visualized on metaphase chromosomes in the two human cervical carcinoma cell lines SiHa and CaSki by fluorescence in situ hybridization with a biotinylated DNA probe (7.9 kb). The fluorescence intensities of hybridization signals from single copies and dispersed clusters of integrated HPV-16 DNA were quantified using a microscope equipped with a cooled-CCD camera that was interfaced to an image processor and host computer. Hybridization signals were localized on chromosomes using separate, registered images of 4',6-diamidino-2-phenylindole (DAPI) or propidium iodide stained metaphase chromosome spreads. In both SiHa and CaSki spreads, a single fluorescein signal was observed on one or both chromatids of chromosome 13, which was identified by simultaneous hybridization with a biotinylated centromere probe specific for chromosomes 13 and 21. Ratios of the distance from 13pter to the HPV-16 signals to the entire chromosome length were approximately 0.63 +/- 0.05 in both SiHa and CaSki cells, indicating the possibility of a common integration domain on chromosome 13. In SiHa cells, no additional signals were observed on other chromosomes. This observation, taken together with literature reports that SiHa cells contain 1 to 2 copies of the HPV-16 genome in this region of chromosome 13, suggests that each fluorescein signal on chromosome 13 represents one equivalent of the HPV-16 genome. The total integrated fluorescence intensity in isolated CaSki metaphase chromosome spreads was approximately two orders of magnitude greater than that of a single copy of HPV-16 DNA in SiHa cells, indicating an increase in HPV-16 copy number.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Noninvasive external recording of cardiac conduction system (His bundle) activity.

Successful and adequate external recording of the cardiac conduction system from the body's surface can be accomplished in 80 to 90 percent of subjects studied. High-gain amplification, signal averaging, and triggering with a conditioned QRS signal results in good recording reproducibility. Averaging of 128 consecutive cycles is adequate, but on occasion averaging of 256 cycles may yield better results. The patients's QRS signal triggers the transfer of signals, which are digitized and stored during the preceding P-R interval. Comparison of external recordings with direct invasive recordings in animals and patients shows good correlation between the major His bundle deflections. The advantages of the system developed include its mobility, triggering the QRS with pretrigger data processing, and instantaneous display on Polaroid photograph. Future research should concentrate on further miniaturization and simplification of the instrumentation, detailed experimental comparison between direct and external recordings for identification of deflections and their origin, further study of the recording lead system, and the most appropriate method of information display.

Animals

Focal liver lesions: MR imaging with Mn-DPDP--initial clinical results in 40 patients.

Manganese (II) N,N'-dipyridoxylethylenediamine-N,N'-diacetate-5,5'-bis(phosphate) (DPDP) was evaluated as a contrast agent for magnetic resonance (MR) imaging (1.5 T) of focal liver lesions in 40 patients. Doses of 5 and 10 mumol/kg were administered intravenously. Mn-DPDP-enhanced T1-weighted images were compared quantitatively and subjectively with standard T1- and T2-weighted nonenhanced images. Use of Mn-DPDP resulted in a statistically significant increase in signal intensity of liver parenchyma in T1-weighted images at both doses. No enhancement was seen in metastases, cholangiocarcinomas, or lymphomas, while all hepatocellular carcinomas were enhanced. Enhancement was seen in focal nodular hyperplasia and in regenerative nodules. The lesion-to-liver contrast in Mn-DPDP-enhanced gradient-recalled-echo images was superior to that of all precontrast images (P less than .01). The number of nonenhancing malignant liver lesions detected in spin-echo (SE) images was increased (272 in T2-weighted SE images vs 390 in T1-weighted Mn-DPDP-enhanced SE images). Image interpretation (eg, visualization and demarcation of the lesions) was markedly better in Mn-DPDP-enhanced images than in all precontrast images (P less than .001).

Adult