A microbial biosensor for trimethylamine using Pseudomonas aminovorans cells.

A biosensor system based on the difference in the oxygen uptake response of two microbial electrodes was developed to monitor trimethylamine (TMA). The first electrode, constructed using Pseudomonas aminovorans grown on TMA, was sensitive to TMA, trimethylamine N-oxide (TMAO), dimethylamine (DMA) and monomethylamine (MMA). The second electrode responding to TMAO, DMA and MMA was prepared using Ps. aminovorans grown on TMAO. The difference in oxygen uptake was linearly related to the TMA concentration in the range of 5-26 microM. The minimum detectable level was 2.6 microM and the relative standard deviation was determined to be 14% for 16 repeated analyses. When operated and stored at 30 degrees C, the response of the system was stable for only 2 days. However, when the biosensor system was operated at 30 degrees C but stored overnight at 4 degrees C, the system was stable up to 20 days. The biosensor system was applicable for the determination of TMA in fish tissue extracts and the results compared well with those determined by HPLC.

Animals

Monitoring glutamine in mammalian cell cultures using an amperometric biosensor.

An amperometric biosensor has been developed for monitoring glutamine in the pulsed-batch cultivation of murine hybridoma cells. Glutamine oxidase was cross-linked with bovine serum albumin (BSA) via glutaraldehyde activation and deposited on a preactivated nylon membrane. Glutaminase was then immobilized on the protein layer and the resulting membrane was attached to the sensing area of a hydrogen peroxide probe (platinum vs silver/silver chloride polarized at +0.7 V). An orthogonal test was performed to optimize the activity of the membrane for glutamine with respect to the concentrations of glutamate oxidase, BSA, glutaminase and glutaraldehyde. There was an excellent linear relationship between the biosensor's response and glutamine in the range 0.1-3 mM. The determination of glutamine could be performed in 2 min and each membrane was reused for at least 300 consecutive analyses. The data obtained also agreed well with those high-performance liquid chromatography, thus validating the applicability of the biosensor.

Amino Acid Oxidoreductases

Improvement of the selectivity of an FIA amperometric biosensor system for glucose.

A flow injection analysis (FIA) biosensor system has been developed for the determination of glucose from urine, blood plasma and foodstuffs. Glucose oxidase was immobilized onto porous aminopropyl glass beads via glutaraldehyde activation to form an enzyme column. The hydrogen peroxide released from the conversion of glucose to gluconic acid was monitored by a platinum electrode vs. silver/silver chloride poised at +700 mV. As a novel aspect to the improvement of the selectivity of the biosensor system, an anion exchange column was placed upstream to remove uric acid, ascorbic acid or acetaminophen, three major electroactive interfering substances which usually occur in urine and blood plasma. Among several resins tested, the effective adsorption of uric and ascorbic acids could be accomplished using an acetate anion exchanger, and the selectivity coefficient was pH dependent. The binding of acetaminophen to the resin was much less efficient and, in all cases, the selectivity coefficient was independent of the operating temperature up to 37 degrees C. When applied to real samples, the data obtained by the biosensor system compared well with those of the standard hexokinase assay. The immobilized glucose oxidase could be reused for at least 2000 repeated analyses without loss of its original activity.

Acetaminophen

Dynamic concentration challenges for biosensor characterization.

A method and apparatus are described for characterization of the steady state and dynamic response of biosensors. The apparatus produces a steady stream of homogeneously mixed analyte whose concentration can be fixed at discrete values or varied continuously. The device is ideally suited for continuously operated biosensors, but is also effective for biosensors that operate in discrete sampling modes. The system permits simultaneous testing of several sensors and determination of the accuracy, precision and repeatability of sensor response. The characteristics of this testing apparatus were validated with ferrocyanide and glucose as indicators. As an example of use of the apparatus, concentration ramps were created and used to complement conventional step changes for characterizing an implantable glucose sensor. The ramp rate can be adjusted easily by scaling the apparatus to simulate the rate of concentration change anticipated during actual monitoring situations.

Animals

Thin-film conductometric biosensors for glucose and urea determination.

The characteristics of the developed conductometric biosensors for urea and glucose determination are described. Conductometric transducers based on thin-film interdigitated metal (Au, Cr, Cu, Ni) electrodes were studied, and enzymes urease and glucose oxidase were used for the selective membranes formation on the chips having gold electrodes. The influence of ionic strength and buffer capacity of the samples on the biosensors response in kinetic and steady-state modes of measurements was thoroughly tested. It was shown that the kinetic response of the sensors does not depend on the buffer capacity of the analyzed sample. In basic features the performance of the developed biosensors is rather close to that of respective enzyme field effect transistor, though the former are much superior when the technological complexity of the transducer itself is considered and taking into account that conductometric sensors require no reference electrode.

Biosensing Techniques

Enzyme biosensor for urea based on a novel pH bulk optode membrane.

A new, absorbance-based enzymatic biosensor membrane for determination of urea is described. A lipophilic, fully LED- and diode laser-compatible pH sensitive dye was incorporated into a plasticized, carboxylated poly(vinyl chloride) membrane and served as the optical transducer of the sensor. Urease was covalently linked to the surface of the pH bulk optode membrane to form a very thin cover. The resulting biosensor membrane allows rapid determination of urea over the 0.3 to 100 mM range. The reproducibility, stability, and effects of pH and buffer concentration on the response of sensor are reported. The preparation of the pH transducer and the immobilization of the enzyme are simple and may easily be adopted to other biosensor types.

Animals

Enzyme support systems for biosensor applications based on gold-coated nylon meshes.

A novel experimental protocol for enzyme immobilization based on the use of a very permeable support is described and applied to the development of an acetylcholinesterase (AChE) based biosensor. In this system, the enzyme was immobilized onto a gold-coated nylon mesh via a self-assembled monolayer of a bifunctional reagent, cystamine, preadsorbed onto the gold surface. This support has been characterized by optical microscopy and electrochemical measurements of permeability. In the assembled biosensor, the AChE modified mesh was placed over a glassy carbon electrode and the response to 4-aminophenylacetate, used as substrate, was monitored via the enzymatic reaction product, 4-aminophenol, by oxidation at +0.25 V vs. SSCE. This approach to biosensor design has been extended to the determination of organophosphorus and carbamate pesticides by their inhibition of AChE enzymatic activity.

Acetylcholinesterase

Lactate solid-state biosensor with multilayer of electrodeposited polymers for flow-injection clinical analysis.

In the lactate biosensor, electrodeposited poly(o-phenylenediamine) serves as a convenient matrix for the immobilization of lactate oxidase, but does not provide sufficient discrimination from several interfering species present in physiological fluids. Their effect, however, can be eliminated by additional modification of the working Pt electrode with a bilayer of electrodeposited polypyrrole/polyphenol. Despite continued decrease in biosensor sensitivity, the newly developed three-layer solid-state biosensor was successfully applied in flow-injection determination of lactate in both undiluted and diluted human blood serum samples over a 10 day period. For the lactate concentration range 0.2-5.0 mM in several series of measurements the correlation coefficient values for comparison with photometric determination using a DuPont dimension clinical analyzer were between 0.96 and 0.99. The reproducibility measured for 1:10 diluted serum was 0.6%. The detection limit was estimated as 2 microM.

Acetaminophen

A fractal analysis of the influence of non-specific binding on antigen-antibody binding kinetics for biosensor applications.

A fractal analysis of the influence of non-specific binding on the specific binding of antigen in solution to antibody immobilized on a biosensor surface is presented for first-, one and a half-, second, and other-order reactions occurring under external diffusion-limited conditions. Both single-step and dual-step binding of antigen in solution to antibody immobilized on the surface is considered. For a first-order reaction, an increase in the fractal parameters, b, leads to a decrease in the amount of antigen in solution bound specifically to the antibody on the surface when non-specific binding is either absent or present. The presence of non-specific binding leads to a decrease in the amount of antigen bound to the antibody on the surface. For a one and a half- and for second-order reactions and when non-specific binding is either absent or present to a small degree (alpha = 0.01), an increase in the fractal parameter, b, leads to a decrease in the amount of antigen bound specifically to the antibody immobilized on the biosensor surface. However, for an alpha value of 0.1, the maximum rate and the amount of antigen bound specifically to the antibody immobilized on the biosensor surface is obtained for fractal parameter values of 0.2 and 0.4, and 0.4 for the one and a half- and for second-order reactions, respectively. Apparently, some amount of heterogeneity is helpful in obtaining the optimum amount and rate of antigen in solution bound specifically to the antibody on the surface for reaction orders higher than one. The applicability of the approach to real antibody surfaces is demonstrated.

Antigen-Antibody Reactions

Application of biosensor for monitoring galactose content.

The quality and quantity of different sugars play a very important role in studying the carbohydrate metabolism of yeast. During the bioprocesses there is a need to follow the concentrations of these sugars. Authors have reported on the development of biosensors for determination of glucose and maltose previously. The aim of this research was to construct a sensor for determining galactose in fermentation broths to prepare the basis for an online monitoring system. Using a modified thin-layer enzyme cell connected to an electrochemical detector cell, a biosensor has been developed for this purpose. Galactose was oxidized with immobilized galactose oxidase enzyme (EC 1.1.3.9) and the hydrogen peroxide generated during the enzyme reaction was determined with an amperometric detector. The parameters for the biochemical and electrochemical reactions were optimized. The pH optimum of 6.6 was found when using phosphate buffer. The buffer solution completed by micro elements (Mg2+, Se2+) gave more stable signs. The activities for raffinose, lactose, glycerol and dihydroxyacetone were 68, 16, 6 and 430%, respectively. With the thin-layer cell more than 900 samples were measured in 6 weeks. Samples obtained from different fermentations were measured with the newly developed galactose sensor and the results were compared with the standard UV method. The correlation coefficient was 0.991. The results showed that the application of the new biosensor was successful.

Biosensing Techniques

Electrochemical biosensors for medicine and ecology.

Research results obtained in the last 3 years in the area of electrochemical amperometric biosensors are presented. Selective electrochemical biosensors are proposed on the basis of investigations of electrode materials, electrolyte content, selective properties of polymer materials and mediators influence. Biosensor parameters for determination of glucose, phenol and biological oxygen demand are described.

Biosensing Techniques

Metrological opportunities of the dynamic mode of operating an enzyme amperometric biosensor.

An algorithm for generating calibration curves that reflects the peculiarities of the dynamic mode of operating of the amperometric biosensor, created on the base of numerical simulations of the sensor behaviour, is proposed. The most important steps are: selection of the informative quantity about the sensor current versus time relationship and the calibration curve processing. Five different informative quantities are tested as well as two ways of representation of calibration curves. The object of study is enzyme catalyzed selective reaction. The values of the kinetic constants used reflect the conversion of glucose to gluconolacton catalyzed by glucose oxidase (GOD) and catalase (CAT). The results show that sensors with different metrological characteristics can be created by means of a selection of informative quantity of the signal of one biosensor transducer. In addition there appears to be a possibility of facilitating the calibration procedure and prolonging the life of the biosensor.

Algorithms

Evaluation of a miniaturized thermal biosensor for the determination of glucose in whole blood.

A miniaturized thermal biosensor has been evaluated as part of a flow-injection analysis system for the determination of glucose in whole blood. Glucose was determined by measuring the heat evolved when samples containing glucose passed through a small column with immobilized glucose oxidase and catalase. Samples of whole blood (1 microliter) can be measured directly, without any pretreatment. The correlation in the response between the thermal biosensor, the Reflolux S meter (Boehringer Mannheim), the Granutest 100 glucose test kit (Merck Diagnostica) and the Ektachem (Kodak) instrument was evaluated. The influence of the hematocrit value and of possible interferences is reported. The correlation measurements show that the thermal biosensor calibrated with aqueous glucose standards generally gives lower values on blood glucose than the reference methods calibrated for serum or blood measurements. Mean negative biases range from 0.53 to 1.16 mmol/l. Differences in sample treatment clearly complicate comparisons and the proper choice of reference method. There was no influence from substances such as ascorbic acid (0.11 mmol/l), uric acid (0.48 mmol/l), urea (4.3 mmol/l) and acetaminophen (0.17 mmol/l) on the response to 5 mmol/l glucose. The hematocrit value does not influence the glucose determination, for hematocrit values of between 13 and 53%.

Biosensing Techniques

Reassessment of the calibration constant for the IAsys biosensor.

A magnitude of 50 are s ng-1 mm2 has been determined for the calibration constant relating biosensor response to the amount of protein bound to the sensor surface of an IAsys cuvette. These studies entailed enzymatic assessment of the extent of lactate dehydrogenase depletion in the liquid phase arising from enzyme binding to a carboxymethyldextran-coated sensor surface, and also estimation of a maximum biosensor response for the electrostatic interaction of ovalbumin with an aminosilane-coated sensor surface. The latter results required correction for contributions to biosensor response resulting from changes in the refractive index of the liquid phase effected by high protein concentrations.

Biosensing Techniques

Bacterial biosensors for monitoring toxic metals.

Biosensors utilize biological components to provide selectivity for monitoring compounds of environmental, clinical and industrial importance. A number of biosensors based on bacteria have recently been developed for monitoring toxic metals in the environment. The advantages and disadvantages of these types of biosensors are discussed.

Bacterial Proteins

Fluorescent-protein biosensors: new tools for drug discovery.

Recent improvements in target discovery and high-throughput screening have increased the pressure at key points along the drug-discovery pipeline. High-content screening was developed to ease the bottlenecks formed at the target-validation and lead-optimization points, and a new generation of reagents that report on specific molecular processes in living cells (fluorescent-protein biosensors) have been important in its development. Creative designs of fluorescent-protein biosensors have emerged and been used to measure the molecular dynamics of macromolecules, metabolites and ions. Recent applications of fluorescent-protein biosensors to biological problems have provided a foundation for their use in biotechnology.

Biosensing Techniques

Effects of microcystins on phosphorylase-a binding to phosphatase-2A: kinetic analysis by surface plasmon resonance biosensor.

Cyclic heptapeptide microcystins are a group of hepatoxicants which exert the cytotoxic effects by inhibiting the catalytic activities of phosphatase-2A (PP-2A) and phosphatase-1 (PP-1) and thus disrupt the normal signal transduction pathways. Microcystins interact with PP-2A and PP-1 by a two-step mechanism involving rapid binding and inactivation of protein phosphatase catalytic subunit, followed by a slower covalent interaction. It was proposed that inactivation of PP-2A/PP-1 catalytic activity by microcystins precedes covalent adduct formation. In this study, we used a biosensor based on surface plasmon resonance (SPR) to examine the effects of three microcystins, MCLR, MCRR and MCYR, on the binding between PP-2A and its substrate, phosphorylase-a (PL-a), during the first step of the interaction. The SPR biosensor provides real-time information on the association and dissociation kinetics of PL-a with immobilized PP-2A in the absence and presence of microcystins. It was found that the affinity of PL-a to microcystin-bound PP-2A was four times smaller compared to unbound PP-2A, due to 50% decreases in the association rates and two-fold increases in dissociation rates of PL-a binding to PP-2A. The results suggest that the rapid binding of microcystins to the PP-2A catalytic site leads to the formation of a noncovalent microcystin/PP-2A adduct. While the adduct formation fully inhibits the catalytic activity of PP-2A, it only results in partial inhibition of the substrate binding. The similar effects of the three microcystins on PP-2A suggest that the toxins bind to PP-2A at the same site and cause similar conformational changes. The present work also demonstrates the potential application of biosensor technology in environmental toxicological research.

Binding Sites

On-line supported liquid membrane-liquid chromatography with a phenol oxidase-based biosensor as a selective detection unit for the determination of phenols in blood plasma.

The potential of on-line combination of supported liquid membrane extraction and column liquid chromatography with a phenol oxidase-based biosensor as a selective detection unit has been investigated for the determination of phenols in human plasma. The phenols are selectively extracted into a porous PTFE (polytetraflouroethene) membrane impregnated with a water-immiscible organic solvent and further into an alkaline acceptor phase. Via an ion-exchange interface, the analytes are transferred to a reversed-phase column where they are separated and detected using the biosensor. No sample pretreatment before the extraction, except centrifugation, is made. Due to the high selectivity both in the extraction and in the detection steps and to the fact that the demands on the chromatographic separation are low, a quick separation using an eluent with a low concentration of organic modifier can be made, without affecting the biosensor response. Detection limits below the 50 microg/l level in blood plasma were obtained for the three model compounds, phenol, p-cresol and 4-chlorophenol.

Biosensing Techniques