PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “false-positive reduction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Efficacy of the self-inflating bulb in confirming tracheal intubation in the morbidly obese.

BACKGROUND: This study was designed to determine the incidence of false-negative and false-positive results when the self-inflating bulb (SIB) is used to differentiate tracheal from esophageal intubation in morbidly obese patients using two techniques. In technique 1, the SIB is compressed before it is connected to the tube; in technique 2, the SIB is compressed after connection to the tube. METHODS: With institutional review board approval, 54 consenting adult morbidly obese patients (body mass index > 35) undergoing elective surgical procedures were included in the study. After anesthetic induction and muscle relaxation, both the trachea and esophagus were intubated under direct vision with identical cuffed tubes. The efficacy of the SIB in verifying the position of both tubes was tested by a second anesthesiologist. The speed of reinflation was graded as rapid ( < 4 s) or none ( > 4 s), using both techniques. In the case of tracheal intubation, the absence of reinflation was recorded as a false-negative, whereas in cases of esophageal intubation, rapid reinflation was recorded as a false-positive. Identification of tube location by the second anesthesiologist was based on SIB reinflation results from techniques 1 and 2, as well as the presence of a flatuslike sound elicited by technique 2 in esophageally placed tubes. All patients were retested by the SIB after receiving three breaths of 400-500 ml each. In all patients exhibiting false-negative results, six obese patients exhibiting true-positive results, and four nonobese patients exhibiting true-positive results, tracheal responses to the SIB maneuvers were observed directly by a flexible fiberoptic bronchoscope incorporating an airtight system, 15-20 min after mechanical ventilation was instituted. RESULTS: The incidence of false-negative results was initially 30% with technique 1 and 11% with technique 2, but decreased to 4% when technique 2 was used after the delivery of three breaths. The second anesthesiologist initially identified tube location in 92.5% of patients correctly. After the delivery of three breaths, tube location was correctly identified in 96.3% of patients. Fiberoptic bronchoscopic examination of the patients exhibiting false-negative results revealed exaggerated inward bulging of the posterior tracheal membrane during reinflation of the SIB when technique 1 was used. CONCLUSIONS: Contrary to previous investigations in healthy patients, the current study demonstrates a high incidence of false-negative results when the SIB is used to confirm tracheal intubation in morbidly obese patients. If the SIB is used, the technique should include compression of the SIB after connection to the tube and should be used in conjunction with other clinical signs and technical aids. The mechanism of false-negative results in these patients seems to be related to reduction of caliber of airways secondary to a marked decrease in functional residual capacity, and collapse of large airways due to invagination of the posterior tracheal wall when sub-atmospheric pressure is generated by the SIB.

Adolescent↗

Successful use of pooled sera to determine HIV-1 seroprevalence in Zaire with development of cost-efficiency models.

To determine the accuracy and cost efficiency of pooling sera prior to HIV-1 testing, sera from 8,000 Kinshasa factory workers and their spouses were screened individually (2.44% seropositive) and in 800 pools of 10 sera each. There were no false-negative or false-positive pools, resulting in a calculated seroprevalence estimate of 2.42%. Further testing of all sera in positive pools can identify HIV-positive individuals. These applications were modeled to compare the cost-efficiency of pooling with individual testing under different conditions. The results suggest that pooling provides an alternative test format for use in both developing and industrialized countries when the seroprevalence and/or the marginal cost of obtaining a sample are sufficiently low. For our cohort, testing only the pools for seroprevalence estimation resulted in a 78% cost saving compared with individual testing; pooling with subsequent identification of individual seropositives represented a 56% cost reduction.

Acquired Immunodeficiency Syndrome↗

A clinic-based system for monitoring the quality of techniques for the diagnosis of gonorrhea.

The author describes a clinic-based system that monitors the quality of techniques for diagnosis of gonorrhea by continuous comparison of the results of gram-strained smears of urethral and cervical specimens with the corresponding cultures. Discrepant results are immediately reviewed. During a two-year period, the system detected two defects in culture incubation, visual defects in a laboratory technician, and three unexplained reductions in cultural sensitivity. The system motivates clinicians and laboratory technicians to maintain a high level of quality control. In 11,474 comparisons of urethral smear and culture results, there was agreement in 96.9% while the smear alone was positive in 1.6% and the culture alone in 1.5%. Review of positive-smear-negative-culture discrepancies indicated that most smears judged "false-positive" were so classified on the basis of false-negative cultures. In study of 1,331 women, the endocervical smeras identified 60% (273/455) of those with positive culture discrepancies. Many of these may have represented false-negative cultures.

Clinical Laboratory Techniques↗

False-positive, follicular and irritant patch test reactions to metal salts.

853 hard metal workers were patch tested with nickel sulphate 5%, potassium dichromate 0.5% and cobalt chloride 1%, each in petrolatum. Non-allergic reactions appeared in 6.5% of the nickel tests, 13% of the chromium tests and 18.3% of the cobalt tests. Most of the individuals with positive, poral or pustular reactions were retested with serial dilutions of metal salts in pet. and in water. The accuracy of a positive initial nickel reaction was 83%, a chromium reaction 40% and a cobalt reaction 62%. The nonallergic reactions were partly reproducible and correlated with both the type of patch test material and with individual factors. Weak and moderately strong positive patch test reactions to metal salts may be irritant and should be checked with serial dilution tests or at least be retested. A reduction of the cobalt chloride concentration from 1% to 0.5% in the standard test material is discussed.

Chromates↗

Selective detection and enumeration of fecal coliforms in water by potentiometric measurement of lipoic acid reduction.

Water samples of various origins were inoculated into a specific coliform-selective lactose broth provided with lipoic (thioctic) acid, and the time evolution of the redox potential of the cultures was monitored during incubation at 41 degrees C by use of gold versus reference electrodes. Positive potential-time responses, i.e., 100-mV potential shifts recorded within 20 h of inoculation, were related to the initial number of fecal coliforms in the broth determined by control enumeration techniques, and the organisms responsible were isolated and identified by conventional procedures. A total of 30 samples of wastewater, 38 of surface water, 553 of groundwater, and 110 of drinking water were tested successively. A total of 240 natural water samples, including 172 groundwater samples, and 1 drinking water sample were found to be positive in the potentiometric test. The majority (i.e., 92.5%) of the relevant potentiometric detection times were shorter than 15 h, and 96% of these could be attributed to Escherichia coli. Fifteen hours corresponded to the limit for detecting 1 E. coli cell per 100 ml of water. About 78% of the potentiometric responses occurring after 15 h were induced by fecal coliforms other than E. coli (Enterobacter cloacae, Klebsiella pneumoniae, and Citrobacter freundii). Calibration curves relating detection times shorter than 15 h to fecal coliform (i.e., E. coli) concentrations were constructed for the natural water samples tested. There were minor variations in the average growth rate of the organisms in the relation to the contamination level of the water tested. The number of false-positive samples in the potentiometric test was equivalent to that of false-negative samples (groundwater or drinking water).

Drinking↗

New laboratory guidelines for serologic diagnosis of Lyme disease: evaluation of the two-test protocol.

Recent guidelines established by the Association of State and Territorial Public Health Laboratory Directors (ASTPHLD) and the U.S. Centers for Disease Control and Prevention (CDC) recommend the use of a two-test protocol for the serologic diagnosis of Lyme disease (LD). The two-test protocol relies on a sensitive screening test, which is followed by specific immunoglobulin M (IgM) and/or IgG immunoblotting (IB), depending on the date of disease onset, of all samples with equivocal and positive screening test results. We evaluated a commercially available IgM-IgG enzyme-linked immunosorbent assay (ELISA) and separate IB tests for IgM and IgG antibodies to Borrelia burgdorferi as candidate assays for the two-test protocol. Serum samples obtained from healthy controls (n = 29), from patients with diagnoses or laboratory findings associated with serologic cross-reactivity to LD (n = 24), and from patients with well-documented early- and late-stage LD provided by the CDC and the College of American Pathologists (n = 53) were examined to determine each assay's individual sensitivity and specificity. No false-positive results were detected among the healthy controls by either ELISA or IB, whereas four false-positive ELISA results were recorded within the cross-reactive group. None of these sera, however, were positive for either IgM or IgG reactivity according to IB band criteria. With regard to the patients with LD, we determined the sensitivity and specificity of the ELISA to be 96 and 100%, respectively, compared with the reference data provided for these specimens. When we compared our IB results with data from CDC, the assay sensitivity and specificity were 80 and 96.2%, respectively, for IgM and 81.8 and 95.8%, respectively, for IgG. Pursuant to this evaluation we assessed the suitability of the two-test protocol by performing a retrospective analysis using clinical history to define samples as positive or negative for LD. We determined clinical sensitivity and specificity for all study subjects (n = 112) to be 50 and 100%, respectively. A reduction in the clinical sensitivity of the two-test protocol was associated with a lack of antibody response or seroconversion in LD patients treated with antibiotics. We conclude that the CDC-ASTPHLD guidelines provide useful criteria for test performance and interpretation aimed at standardizing the serologic diagnosis of LD.

Borrelia burgdorferi Group↗

Trypsinised human O erythrocytes in the detection of rubella-specific IgM by sera fractionation on sucrose density gradient and absorption with staphylococcal protein A.

Detection of rubella virus-specific IgM employing trypsin-treated human group O erythrocytes was evaluated using the method of sera fractionation on sucrose density gradients (SDG) and that of sera absorption with staphylococcal protein A. The former method proved to be highly specific and sensitive in confirming or excluding rubella by demonstration of specific IgM. In contrast, the latter method provided comparable results in only 71.43% of specimens tested by both methods while false-positive or -negative IgM results were obtained in the remaining 28.57% of specimens. In view of these results, therefore, it is recommended that all those specimens found positive for specific IgM by the protein A method must be confirmed by another procedure, possibly that of specific IgM reduction with 2-mercaptoethanol.

ABO Blood-Group System↗

Results of ophthalmosonometry and supraorbital photoplethysmography in evaluating carotid arterial stenoses.

A total of 263 patients underwent either periorbital ophthalmosonometry (Doppler ultrasound) or a combination of ophthalmosonometry and supraorbital photoplethysmography (SOPPG) to determine the presence or absence of a hemodynamically significant lesion (occlusion or greater than 50% reduction in lumen diameter). There were 522 vessels studied with Doppler ultrasound and 272 vessels with a combination of the two modalities. The tests were correlated with carotid arteriography to determine their accuracy. Overall accuracy of the Doppler ultrasound examination was 95%. A normal Doppler ultrasound examination was obtained in 367 vessels and arteriography confirmed the absence of a hemodynamically significant lesion in 93%. Of 155 vessels with an abnormal Doppler examination, 149 (96%) were proven on arteriography to have hemodynamically significant lesions. The Doppler ultrasound examination had a high incidence of false-negative examinations (26%) in those vessels that were between 50% and 99% stenotic, however. The SOPPG alone had a high incidence of false-positive examinations (19%); however, in 155 vessels with a normal SOPPG, 98% were proved to have no hemodynamically significant lesion. The combination of Doppler ultrasound and SOPPG was highly accurate in identifying patients with hemodynamically significant lesions. Of 97 vessels with such lesions, 96 (99%) had either an abnormal Doppler ultrasound examination or an abnormal SOPPG. In 240 vessels with concordant results of the Doppler ultrasound and SOPPG, the presence or absence of a hemodynamically significant lesion was accurately predicted in 235 (98%).

Arterial Occlusive Diseases↗

Evaluation of the usefulness of nitroblue tetrazolium reduction test (NBT test) for detection of bacterial infection in cancer patients.

False positivity of the NBT test in neoplastic diseases described by some authose may be a limitation in the use of the test for infection screening in cancer patients. For explaining this problem studies were performed in a group of 30 patients with various untreated malignancies without infection and in 20 of these with bacteriologically confirmed infections. The obtained results were compared with those in groups of normal persons without and with infection. Slightly modified Park method for spontaneous and stimulated NBT test was used. No significant differences between patients of both groups without infection were found. The increase in positivity of the test in presence of infection was lower in cancer patients than in normal subjects, however, it was non-significant. We did not observe any false-positive results in our patients, though one case of false negativity in myeloma is described separately. It is concluded that neoplastic disease does not cause, as such positivity of the NBT test. Because of similar response of NBT test to presence of infection, the NBT test is recognized as very useful for infection screening in cancer patients similarly as in normal persons.

Adult↗

[Echographic measuring of the length of the fetal femur in the screening for Down syndrome].

OBJECTIVE: Our purpose was to assess the value of sonographic measurement of fetal femur length in the second trimester, as a screening tool for Down's syndrome. STUDY DESIGN: We evaluated a consecutive series of fetuses scanned by a single sonologist at the time of amniocentesis between 15 and 19 weeks. The study group consisted of fetuses with Down's syndrome (N = 16); the control group comprised normal fetuses (N = 1163). A linear regression model of the normal femur length based on biparietal diameter (BPD), was established for our population; the ratios of measured to expected femur length for a viven BPD (FL M/E) were calculated in the two groups. To test statistical significance of observed differences between case and control population, unpaired t test was used. The ability of specific FL M/E cut-off values to discriminate between Down syndrome and normal fetuses was assessed by Fisher's exact test. RESULTS: The mean ratio of measured to expected femur length was significantly lower in the Down syndrome as compared with control population (0.9473, DS 0.0795) versus 1.0, DS 0.0745) (p < 0.0045). The ratio of 0.91 or less predicted Down's syndrome with a sensitivity of 43.7% and a false-positive rate of 8.6%. For women with risk of one in 250 and one in 1000 of having an affected fetus based on maternal age, a shortened femur yielded positive predictive values of one in 26 and one in 105, respectively. CONCLUSION: These results suggest that the sonographic measurement of fetal femur length for the screening of Down syndrome in the low-risk population is hindered by a high false positive rate (about 9%). It follows that the percentage of women requiring an amniocentesis would increase to un unacceptably high level. The utilization of this biometric marker may be helpful, in our opinion, for identifying fetuses at risk for Down syndrome in women between 35 and 38 years of age. These women in fact, are not offered amniocentesis for the prenatal diagnosis of Down's syndrome in the majority of italian institutions. The sonographic measurement of fetal femur length could detect about 45% of fetal Down's syndrome, offering an amniocentesis to 9% of women, with a consequent reduction of the cost required. Only a prospective study can evaluate the efficacy of this method to predict Down syndrome in such group of women.

Adult↗

[Measuring temporal transmission properties of the visual system. Diagnostic value in suspected optic nerve neuritis].

The temporal transfer properties of the visual system were examined in 157 patients with suspected acute optic neuritis or papillitis. Foveal modulation sensitivity was measured as a function of temporal frequency (DeLange curve) both for the affected eye and the unaffected fellow eye. Patients with acute optic neuritis typically show a reduction of foveal modulation sensitivity at all temporal frequencies, high temporal frequencies above 10 cps being more markedly affected. The aim of the present study was to determine the sensitivity and specificity of this simple psychophysical procedure for the diagnosis of neuritis or papillitis in a reasonably large population of patients with suspected acute optic neuritis or papillitis. In each case the final diagnosis was confirmed by evaluation of the clinical signs and symptoms, the course of disease and additional diagnostic procedures, e.g. electrophysiology, perimetry, neurological examination including CT, lumbal puncture and examination of cerebrospinal fluid. In 136 cases (86.6%) the result read from the DeLange curve was correctly positive or negative. In 17 cases (10.8%) the DeLange curve indicated a false-positive and in 4 cases (2.6%), a false-negative result.

Flicker Fusion↗

Strategies for screening blood for human immunodeficiency virus antibody. Use of a decision support system.

A decision analytic model was used to examine alternative strategies to screen donated blood for human immunodeficiency virus (HIV) using data from the literature and from 1987 blood-screening programs in areas with high and low prevalence of HIV. Sensitivity analyses incorporated uncertainties about HIV infection and test performance. Current screening strategies are estimated to allow 20.5 infected units per million donated units to be transfused at a cost of $16,850 per HIV-positive unit detected in high-prevalence areas and 4.7 infected units per million donated units to be transfused at a cost of $32,275 per HIV-positive unit detected in low prevalence areas, with nine false-positive notifications of uninfected patients per million units screened and 14.9 discarded, noninfected units per HIV-positive unit in low-prevalence areas. Testing donated blood for HIV can be improved by individualizing screening strategies for areas with different prevalences of HIV. Efforts to further reduce transfusion-associated HIV should focus on improved test performance in early stages of infection, reduction of unnecessary transfusions, donor recruitment in lower-risk groups, and public health measures to reduce HIV infection among the general population.

Blood Donors↗

Scintigraphic, electrocardiographic, and enzymatic diagnosis of perioperative myocardial infarction in patients undergoing myocardial revascularization.

To assess the incidence of perioperative myocardial infarction, 214 consecutive patients were evaluated 1-5 days after coronary bypass surgery, using Tc-99m pyrophosphate (TcPPi) myocardial imaging, serial electrocardiograms (ECG), and enzyme levels (SGOT, LDH, CPK). On the basis of the clinical course and scintigraphic, enzymatic, and ECG changes, the diagnosis of perioperative infarction was definite in 17 of 241 cases (7.9%) and probable in six of 241 (2.8%). In all of these 23 patients, TcPPi scans were abnormal; one additional patient had a false-positive scintigram. Only 13 of the 23 had ECG evidence of infarction, but there were no false positives. We set the threshold for abnormality of enzyme changes quite high, owing to experience in more than 900 postoperative patients (SGOT greater than 200, LDH greater than 500, CPK greater than 500 on the same day). Using these criteria, 22 of the 23 infarct patients had abnormal enzymes, and six others were falsely positive. These results indicate a relatively low sensitivity for the ECG in diagnosing perioperative infarction, but the lack of false positives suggests high specificity. The sensitivity and specificity of the enzymes and the TcPPi image were both excellent and quite similar; the main difference was a reduction of certainty of infarction with the enzyme criteria, caused by the six patients whose enzyme values were falsely positive. Considering its sensitivity, specificity, and ability to locate and to a certain extent quantitate necrosis. TcPPi imaging is probably the most valuable means of diagnosing perioperative myocardial infarction.

Clinical Enzyme Tests↗

[Comparison between the loading test and selective coronary angiography in stenocardia].

The results from the step-wise loading test to 75 per cent of the age maximum pulse rate, performed by veloergemeter or thread-mill in 52 patients (9 females and 43 males, II of them with atypical chest pain and II with stenocardia) were juxtaposed to the data from the selective coronarography. It was established that the a reduction of ST segment greater than I mm and the appearance of precordial pain, degree III by the five-grade scale, have almost identical specificity (70% and 64% resp) and a predicting value of the positive result (68% and 70% resp) and a slightly higher sensitivity to pain (68% and 84% resp) in the detection of coronary stenosis greater than 50 per cent of the diameter of a main coronary vessel. The combination of the signs precordial pain degree III and/or ST reduction greater than I mm and/or elevation of ST greater than 2 mm, with same predicting value (67%) maintained, but with a considerably enhanced sensitivity (96%) proved to be most adequate as a criterion of the positive test. A reduction of ST segment greater than 22 mm is characterized by decrease of sensitivity (40%) but with a considerable increase of specificity (96%). The positivation of that sign suggests the presence mainly of a multibranch disease. The patients with coronary stenosis greater than 50%, rarely reach a physical capacity over 100 wt (7 x oxygen consumption) and a product of the maximum reached pulse rate and systolic blood pressure over 20 000 as compared with those without stenosis, but no difference among the patients with one-branch and multi-branch disease was established. The electrocardiographic changes in the patients with a true positive test with loading is more often retained after 4th minute of the rehabilitation phase as compared with those of the patients with false-positive test. Evidence exists to admit that the predicting value of the positive test is poorer in the patients with atypical pains and females.

Adult↗

[Chlamydia infection and CIN].

Under the hypothesis that a chronic infection of the cervical epithelium leads to a reduction in the immunological response, a study was carried out to compare the possible relationship between chlamydial infection and CIN. 187 patients were referred to hospital for histological confirmation because of a cytological smear result (PAP III and IV a). Smears were examined for chlamydia antigens using immunofluorescence. The presence of antichlamydial IgA and IgG was performed in serum using an indirect immunohistochemical method. These tests confirmed CIN in 163 patients. The infection rate with chlamydia was 52.9%, 15.9% of CIN patients showing an active chlamydial infection. Inclusion of topographical findings, together with differential evaluation of colposcopic results, with reference to the transformation zone, allow for a separation between inflammation and dysplasia. The confirmation of a positive chlamydial infection and colposcopic criteria may help to reduce the high percentage of false-positive findings in the problem-group of PAP III patients. It appears that reservations about smear controls after doxycyclin therapy--including treatment of sexual partners--is justified.

Antibodies, Bacterial↗

Role of transesophageal echocardiography in dissection of the aorta and evaluation of degenerative aortic disease.

The combination of different ultrasound techniques such as transthoracic, suprasternal, subcostal, and TEE has a high sensitivity and specificity in the diagnosis of aortic dissection. Limitations of this combined ultrasound technique are related to the visualization of the ascending part of the aortic arch, which, because of the interposition of the trachea, cannot be visualized completely. The beginning or end of a dissection in this part of the aorta may be misinterpreted. However, false-negative results are rare. False-positive results due to artifacts resulting from reverberations in an ectatic ascending aorta must be taken into account. The most important diagnostic goals in acute or chronic aortic dissection are (1) confirmation of the diagnosis by visualization of the intimal membrane; (2) the differentiation of true and false lumen, depending on visualization of spontaneous echocardiographic contrast, thrombus formation, slow or reduced reversed flow, systolic diameter reduction, and signs of entry jet into the false lumen; (3) detection of intimal tear, demonstrating communication by 2-D or color Doppler echocardiography; (4) determination of the extent of dissection with classification according to DeBakey types I, II, and III, or Stanford types A and B, with differentiation between communicating or noncommunicating dissection and antegrade or retrograde dissection limited to the descending aorta or expanding into the ascending aorta; (5) detection of wall motion abnormalities as a sign of preexisting coronary artery disease or myocardial ischemia due to ostium occlusion by an intimal flap, coronary artery rupture, or collapse of the true lumen during diastole; (6) detection and grading of aortic insufficiency; (7) detection of side branch involvement by suprasternal, subcostal, and abdominal sonography (which will provide information about the choice of the site for cannulation or catheterization of the femoral artery); and (8) detection of pericardial or pleural effusion and mediastinal hematoma as signs of an emergency situation (i.e., suspending rupture). Based on ultrasound diagnostic information, operation can be performed in all acute situations in patients with type A dissection without further investigation. The ability to act decisively in this setting is particularly important in patients with signs suggesting a dire prognosis (i.e., pericardial or pleural effusion or mediastinal hematoma). For follow-up studies, the combination of echocardiography with MR tomography is recommended. With TEE, entry tears can be detected with a higher sensitivity than with MR tomography. This capability may be important for the patient's prognosis. MR tomography, on the other hand, has a better spatial resolution showing the entire aorta, particularly the ascending aortic arch.

Aged↗

The signal-averaged ECG becomes late potential-positive at low noise levels in healthy subjects.

Late potentials are detected at various noise levels in clinical studies. The aim of this study was to quantify the effect of residual noise level on the signal-averaged ECG. Thirty minutes of raw ECG (lead -X, +X, -Y, +Y, -Z, and +Z) from 10 healthy volunteers were digitized and stored on optical discs. Each ECG was analysed by four signal averaging procedures to noise level 0.1, 0.2, 0.3, and 0.4 microV, respectively. At each noise level, time domain analysis of the filtered vector (40-250 Hz) included determination of the QRS duration (QRS), late potential duration (LPD, duration of terminal signals below 40 microV), and root-mean-square voltage of the terminal 40 ms of the filtered QRS (RMS40). On average, the measured signal-averaged QRS duration was prolonged by 7.0 ms (range 0.9-12.5 ms) per 0.1 microV reduction in noise level. Late potential duration increased by 5.9 ms (range 0.2-10.0 ms) per 0.1 microV reduction in noise level, and RMS40 was reduced by 9.1 microV (range 0.5-20.2 microV) per 0.1 microV reduction in noise level. At noise level 0.4 microV, 0.3 microV, 0.2 microV, and 0.1 microV the number of late potential-positive subjects were 1, 2, 4, and 6, respectively. Late potential parameters are significantly dependent on noise level after signal averaging. Using conventional criteria for late potentials, healthy subjects become false-positive at low noise levels. Establishment of standards for noise level is recommended.

Adult↗