PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “RADIUS FRACTURES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

Ligamentotaxis and bone grafting for comminuted fractures of the distal radius.

The conventional treatment of comminuted fractures in the distal radius has been unsatisfactory. We therefore made a prospective study using the principle of ligamentotoxis and primary cancellous bone grafting as the uniform method of treatment. Ligamentotaxis was maintained by using an external fixator for three weeks only, after which a carefully monitored programme of rehabilitation was given. We have reviewed 72 consecutive distal radial fractures after a follow-up of 7 to 40 months (average 11 months). Reduction had been maintained during healing and over 80% of patients regained full range of movement in hands, wrists and forearms with strong and pain-free wrist function. Complications were infrequent and gave no real problems. We conclude that distraction, external fixation and bone grafting appears to be an excellent method of treating comminuted fractures of the distal radius.

Adolescent↗

Radio-scapho-lunate partial wrist arthrodesis following comminuted fractures of the distal radius.

Painful radiocarpal arthritis following comminuted fractures of the distal radius may be treated either by total wrist fusion or by procedures which preserve movement. The authors have reviewed 15 patients with such fractures who have undergone radio-scapho-lunate partial arthrodesis. They report the results with an average follow-up of 23.8 months. Pain was abolished in 7 patients and resolved virtually completely in 4 cases. Restored grip strength averaged 49% of the contralateral side. There was considerable limitation of postoperative range of motion which was restricted to an oblique plane extending dorso-radial to palmar-ulnar. Most patients did not report this as a problem. Two cases of non-union were reported as well as a 35.7% incidence of secondary degenerative change in the midcarpal joint. This feature casts doubt on the predictability of outcome of this procedure.

Adult↗

[Corrective osteotomy for the treatment of carpal tunnel syndrome in malaligned healed fractures of the distal radius].

This report deals with 12 patients with fractures of the distal radius that healed with malpositioning with dorsal sinking of the articular surface. This malalignment was followed in all patients by a compression syndrome of the median nerve. All patients underwent an osteotomy by the dorsal approach to correct this malalignment of the distal radius. The carpal ligament was not released simultaneously. In 11 patients a significant reduction in the typical night pain was noticed. Normal or almost normal sensitivity was achieved within the first 2 months (2 weeks to 4 months). Only in one patient was release of the carpal ligament necessary after 6 months, because the osteotomy had no effect on the pain. In the follow-up examination after 6 years, significantly better wrist function was noticed in all patients, and 11 had normal function of the median nerve. In only one patient with moderate loss of sensitivity still present, although these was an obvious significant reduction in pain. In this patient the osteotomy was performed very late (after 10 months). Thus, an osteotomy by the dorsal approach has the advantage of restoring normal function of both the wrist and median nerve.

Aged↗

Percutaneous and limited open fixation of fractures of the distal radius.

Percutaneous and limited open fixation of fractures of the distal radius is an important method of treatment for many unstable fractures such as unstable dorsal bending fractures, shearing fractures of the radial styloid and lunate facet, and simple articular fractures. The quality of the reduction is monitored with image intensification and the tactic of the reduction is based on manipulation of the fracture fragments by longitudinal traction, percutaneous manipulation, and in some instances by direct manipulation through small incisions. The role of arthroscopy remains uncertain and may represent an alternative to open exposure of the articular surface in some patients although bone grafting may be necessary in patients with fractures with significant metaphyseal defects.

Arthroscopy↗

Biomechanical and biological considerations relating to the clinical use of the Point Contact-Fixator--evaluation of the device handling test in the treatment of diaphyseal fractures of the radius and/or ulna.

The Point Contact-Fixator (PC-Fix) was designed as part of the developmental evolution of more biological devices for internal fixations. It is a device characterized by minimal contact to the underlying periosteum and bone, hereby minimizing potential damage to perfusion. A multicentre handling test was conducted in 1993 and 1994 in six hospitals to assess its performance. A total of 83 fractured forearm bones (34 radii and 49 ulnae) in 52 patients were stabilized with a PC-Fix. The mean age of the patients was 37 years. There were 24 AO type A, 24 type B and 5 type C fractures. Nine fractures were open. Mean follow-up was 15.6 months; follow-up was 100%. All 21 surgeons involved considered the use of the PC-Fix self-explanatory and relatively easy. Handling difficulties were mainly related to insertion of the monocortical screws. In particular, the precision required for insertion, the inability to incline the screw and the inability to pull the plate to the bone using the screw were considered hard to deal with. Stripping of the hexagonal slot was a problem at removal of the implant, possibly related to overtightening of the screws at insertion. In 76 of 83 bones (49 of 53 forearms), the fractures united without additional surgery. The healing pattern typically showed early callus formation bridging the fracture, followed by progressive mineralization of the central radiolucent line. Complications included one infection, one late displacement and four delayed unions, all requiring revision surgery. In 8 forearms, plate removal was performed after a mean of 10.3 months. Two refractures occurred after removal of the implant 6 and 7 months postoperatively. In conclusion, the practical handling of the new implant was straightforward and easily learnt. The treatment failures observed were related to technical and strategic errors. We consider that, when using devices with a locking compression principle, a minimum number of three screws should be placed on each side of the fracture, that interfragmentary compression of simple fractures is desirable in order to increase stability and that, contrary to in vivo animal studies, early plate removal is not indicated. The trend in fracture fixation is to improve the biomechanical and biological properties of operating technique and the devices used. The PC-Fix has proven a useful step in the right direction in this evolutionary process.

Adolescent↗

Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Using a volar approach to avoid the soft tissue problems associated with dorsal plating, we treated a consecutive series of 29 patients with 31 dorsally displaced, unstable distal radial fractures with a new fixed-angle internal fixation device. At a minimal follow-up time of 12 months the fractures had healed with highly satisfactory radiographic and functional results. The final volar tilt averaged 5 degrees; radial inclination, 21 degrees; radial shortening, 1 mm; and articular incongruity, 0 mm. Wrist motion at final follow-up examination averaged 59 degrees extension, 57 degrees flexion, 27 degrees ulnar deviation, 17 degrees radial deviation, 80 degrees pronation, and 78 degrees supination. Grip strength was 79% of the contralateral side. The overall outcome according to the Gartland and Werley scales showed 19 excellent and 12 good results. Our experience indicates that most dorsally displaced distal radius fractures can be anatomically reduced and fixed through a volar approach. The combination of stable internal fixation with the preservation of the dorsal soft tissues resulted in rapid fracture healing, reduced need for bone grafting, and low incidence of tendon problems in our study.

Adult↗

The most frequent traumatic orthopaedic injuries from a national pediatric inpatient population.

Pediatric trauma remains a leading cause of morbidity and mortality of children in the United States and entails exorbitant costs. A 1997 national pediatric inpatient database, the Kids' Inpatient Database, was reviewed for current trauma and practice patterns and was found to contain over 84,000 patients admitted for orthopaedic trauma. These patients accrued an estimated 932.8 million dollars in hospital charges. Femur fracture was the most frequent injury among this patient group (21.7% of orthopaedic trauma), followed by tibia and/or fibula fracture (21.5%), humerus fracture (17.0%), radius and/or ulna fracture (14.8%), and vertebral fracture (5.2%). While the majority of pediatric orthopaedic trauma was treated at non-children's hospitals (70.4%), patients with certain diagnoses such as femur, humerus, vertebral, pelvic, or hand/finger fracture or a back sprain/strain were directed to children's hospitals more frequently compared with the total number of pediatric orthopaedic trauma patients. Practice patterns varied for certain subgroups (eg, femoral shaft fractures) of patients, depending on the type of hospital where the child was treated. Children who sustained a femoral shaft fracture in the 6-to-10-year age group were significantly more likely to receive internal fixation versus casting or traction if they were treated at a children's hospital. Understanding the patterns in which traumatic injuries occur in children is paramount to establishing effective injury prevention, as well as adapting treatment to optimize outcomes.

Adolescent↗

Intraarticular fractures of the distal radius: a cadaveric study to determine if ligamentotaxis restores radiopalmar tilt.

Nineteen fresh cadaver wrists were divested of all dorsal and palmar tissues to the wrist capsule and extrinic and intrinsic ligaments. A Frykman VII type fracture was established across the radiocarpal and radioulnar joints. The dorsal and palmar wrist ligaments were left intact. The forearms were stabilized in an arm board and an external fixation device and traction applied through a Kirschner wire at the base of the third metacarpal. Three positions of wrist flexion; neutral, 15, and 30 degrees, with 10 and 20 pounds of traction were used to attempt to reestablish radiopalmar tilt. Only when the entire palmar ligamentous structures were transected at the radius was radiopalmar tilt reestablished. Ligamentotaxis alone is not a reliable method to reestablish radiopalmar tilt in intraarticular distal radius fractures.

Fracture Fixation↗

Use of the dynamic compression plate for treatment of equine long-bone fractures.

Long-bone fractures of 6 foals admitted consecutively to the Ohio State University Veterinary Hospital were treated successfully with ASIF dynamic compression plating. The cases included 2 foals with closed fracture of the metacarpus, and 1 foal each with open nonunion of the metatarsus, closed fracture of the radius, open fracture of the tibia, and open fracture of the ulna. Five of these foals became sound, with no deformity, so they could be trained for racing or showing. The 6th foal, a filly with nonunion, became "pasture-sound" and was scheduled for breeding. It was concluded that the dynamic compression plates have many advantages over conventional ASIF plates. These advantages include: the plates can be put near the end of bones; screws can be put at an angle other than 90 degrees to the plate; cancellous screws can be used in any hole; plates can be shaped and the screw heads will still fit the holes; less exposure is required; and operating time is shorter.

Animals↗

Geometric variables from DXA of the radius predict forearm fracture load in vitro.

The purpose of this investigation was to determine the cross-sectional geometry of the radius in female and male cadaveric specimens using dual-energy X-ray absorptiometry (DXA), to measure the accuracy of this technique compared with a digitizing procedure, and to measure the correlation between these DXA-based geometric variables and the load required to produce a forearm fracture. Paired intact forearms were scanned at a distal site and at a site approximately 30% of the forearm length from the distal end. The cross-sectional area and the moments of inertia of two sections at 10 and 30% of the forearm length were computed from the X-ray attenuation data. One member of each pair was then sectioned at the 30% location, which is mostly cortical bone, and the section was traced on a digitizing pad. The other forearm was loaded to failure in a servohydraulic materials test system. The DXA-based area and moment of inertia at 30% correlated significantly with the digitized results (r2 = 0.93 for area; r2 = 0.95 for moment; P < 0.001). The conventional bone mineral density from DXA did not associate significantly with failure load, but the minimum moment of inertia and the cross-sectional area at 10% correlated in a strong and significant manner with the forearm fracture force (r2 = 0.67 for area; r2 = 0.66 for moment; P < 0.001). The determination of radial bone cross-sectional geometry, therefore, should have better discriminatory capabilities than bone mineral density in studies of bone fragility and fracture risk.

Absorptiometry, Photon↗

Role of dynamic external fixator in the management of fractures of distal end of radius.

The intra-articular fracture of radius has been an enigma for orthopaedic surgeons since time immemorial. It is a dilemma as to when to use the fixator, when to mobilise after fixator or simply treat it by conservative means. Numerous fixators are in vogue depending on the preference of the surgeon--in the present prospective study the results of dynamic external fixator--which, based on the principle of ligamentotaxis, were evaluated over a 3-year period and the results showed that although excellent radiological results were seen in 90% of the cases yet only 75% of the cases had a excellent functional result.

Adult↗

Anterior margin articular fractures of the distal radius.

Twenty anterior articular margin distal radial fractures were treated in an 11-year period. The size of the articular fragment was determined by the lateral radiograph to be either < or > 50% of the articular surface. Seventeen patients were > 60 years of age, range: 40 to 78; average age: 67. Seven were initially treated by closed manipulation, but four lost position and were internally stabilized. The remaining 13 were primarily stabilized by application of an anterior plate. Twelve patients were followed > 2 years and eight > 5 years, with an average follow-up of 3.8 years. The greater loss of wrist extension in the smaller articular fragment group was statistically significant. All patients treated by plate stabilization returned to their prefracture activities. In this fracture, the T-plate proved to be a satisfactory stabilizing implant.

Adult↗