PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

Determination of 2,4,6-trichloroanisole and guaiacol in cork stoppers by pressurised fluid extraction and gas chromatography-mass spectrometry.

This paper describes the development of an analytical method consisting of pressurised fluid extraction (PFE) and gas chromatography-mass spectrometry (GC-MS) using experimental designs to determine two volatile compounds in naturally-tainted cork stoppers. The target analytes, 2,4,6-trichloroanisole (2,4,6-TCA) and guaiacol, are involved in the cork taint of wine. First, a Plackett-Burman experimental design was carried out in order to determine the significant experimental parameters affecting the PFE process, and then a central composite design was used to optimise these significant parameters. Once the method had been optimised, the influence of the number of extraction cycles was studied. The method was applied to determine the concentration of 2,4,6-TCA and guaiacol in three cork samples, and the results were compared with the ones obtained by multiple headspace-solid-phase microextraction (MHS-SPME) and by Soxhlet extraction.

Anisoles↗

Liquid chromatography electrospray tandem mass spectrometric and desorption electrospray ionization tandem mass spectrometric analysis of chemical warfare agents in office media typically collected during a forensic investigation.

Most prior analytical studies have dealt with the determination of chemical warfare agents in environmental or biological matrices that would typically be collected following battlefield use or in support of the Chemical Weapons Convention. These methods may be useful for some investigations, but may not be practical for indoor forensic investigations where chemical warfare agent use is suspected. There is a need for analytical methods for chemical warfare agent identification in office media, including flooring, wall surfaces, office fabrics and paper products, which would typically be collected in an office environment during forensic investigations. During this study, typical office environment media were spiked at the 4-20microg/g level with either a complex munitions grade sample of tabun (GA) or with a standard containing the three nerve agents, sarin (GB), cyclohexyl methylphosphonofluoridate (GF), soman (GD) and the nerve agent simulant, triethyl phosphate (TEP), to evaluate the potentials of liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) and liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for forensic purposes. An emerging technique, desorption electrospray ionization (DESI-MS/MS), was also investigated for the direct determination of TEP, GB and GD sampled onto solid phase microextraction (SPME) fibers exposed to spiked office media. The spiked chemical warfare agents were recovered with varying efficiencies during this study, but in all cases sufficient chemical warfare agent was recovered for mass spectrometric identification purposes. Full high resolution mass spectra were acquired for all the chemical warfare agents in the continuum mode, which typically resulted in mass measurement errors of 0.001Da or less.

Central Nervous System Agents↗

Rapid tool for distinction of wines based on the global volatile signature.

This work describes a novel methodology for the rapid distinction of wines by headspace solid-phase microextraction coupled to gas chromatography-mass spectrometry, followed by principal component analysis of the data (HS-SPME-GC-MS-PCA). Headspace SPME is used to extract and concentrate the volatile and semi-volatile fractions. A DB-FFAP fused silica GC capillary column of 30 m at 220 degrees C was used acting as a transfer line of the components sorbed by the Carbowax-divinylbenzene coating fibre to the mass spectrometer, which acts as a sensor (30<m/z<300). In this methodology, which does not require any pre-treatment of the sample, the global volatile signature of the wine headspace (chromatographic profile and m/z pattern of fragmentation in each scan) is evaluated without complete chromatographic separation of its components. In order to retrieve from the data as much chemical information as possible and to extract m/z fragments (markers) for the characterisation and distinction of the wines varieties, a PCA was applied to the data resultant from the unresolved volatile fraction. In the present study, two different monovarietal white wines (Vitis vinifera L. var. Fernão-Pires and Arinto) were tested. Associated to the fast character of the proposed methodology and robustness taking into account the extraction time, it is also important to focus the higher sensibility and the lower effect of the sample moisture of the MS sensor response when compared to the conventional e-noses.

Alcohols↗

Simplified analysis of organic compounds in headspace and aqueous samples by high-capacity sample enrichment probe.

A sample enrichment probe (SEP) consisting of a thin rod of an inert material and provided at one end with a short sleeve of polydimethylsilicone rubber was used for the high-capacity sample enrichment of analytes from gaseous and aqueous samples for analysis by gas chromatography (GC) and its hyphenated techniques. The silicone rubber was exposed to the analytical sample, after which the end of the rod carrying the silicone rubber was introduced into the injector and the analytes thermally desorbed and analysed by GC. This technique is similar to, but differs from, solid-phase microextraction (SPME) in that a much larger volume of the sorptive phase is employed, the sorptive phase is not introduced into the inlet of the GC via a needle and the injector is opened to the atmosphere for the introduction and removal of the SEP. In the determination of volatile and semi-volatile organic compounds in gaseous and aqueous media, the SEP technique gave results comparable with those obtained by the stir-bar-sorptive extraction (SBSE) and high-capacity sorption probe (HCSP) techniques. Implementation of the SEP technique requires only minor adaptations to the gas chromatograph and does not require any auxiliary thermal desorption and cryotrapping equipment.

Chromatography, Gas↗

Automated analysis of 2-methyl-3-furanthiol and 3-mercaptohexyl acetate at ng L(-1) level by headspace solid-phase microextracion with on-fibre derivatisation and gas chromatography-negative chemical ionization mass spectrometric determination.

A fast and automated method for the analysis at ng L(-1) level of aroma-powerful polyfunctional thiols has been developed and applied to wine. The sample is just poured in a 20 mL vial and its vapour extracted with a poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) solid-phase microextraction fibre (65 microm thickness) previously exposed to vapours of the reactive (pentafluorobenzyl bromide) and of an alkali (tributylamine). The derivatised compounds are subsequently desorbed in the GC system and determined by negative chemical ionization mass spectrometry. The method is fully automated by using a Combi-Pal autosampler conveniently programmed. The analysis takes 50 min, which contrasts to the long and tedious methods previously proposed. The development of an optimal procedure is constrained by the aggressive character of the reagent (towards the fibre and the chromatographic column), its volatility and the quality of the blanks that can be obtained. Therefore, a critical step was fixing in the fibre a "safe" and repetitive amount of reagent. This was achieved by exposing the fibre (5 min) to the vapours of a water:acetone (9:1) solution containing 200mg L(-1) of reagent. Under these conditions, the extraction-derivatisation of analytes improves with time and temperature, and the best working conditions are dictated by a compromise between sensitivity, speed and chromatographic performance. Although analytes studied were 2-methyl-3-furanthiol, 4-mercapto-4-methyl-2-pentanone, 3-mercaptohexanol, 2-furanmethanethiol and 3-mercaptohexyl acetate, a good analytical performance could be achieved only for these two last compounds. Both of them can be repetitively (10%<RSD<20%) determined in wine at concentrations below 0.1 ng L(-1). Other aspects considered in the method setup were the oxidation of analytes during the process, and the electron-capture detection (ECD) and MS properties of the pentafluorobenzyl derivatives of different polyfunctional thiols.

Acetates↗

On-rod standardization technique for time-weighted average water sampling with a polydimethylsiloxane rod.

In this study, a polydimethylsiloxane (PDMS) rod was developed as a passive sampler, based on the solid-phase microextraction (SPME) technique. The on-rod standardization technique was applied to the PDMS rod passive sampler. Using the desorption of the pre-loaded standard on the PDMS rod to calibrate the absorption of the target analytes allows for the determination of the time-weighted average (TWA) concentrations of pollutants in the aqueous media. The PDMS rod passive sampler with the on-rod standardization technique was tested in the laboratory with a flow-through system and was subsequently applied to measure TWA concentrations of polycyclic aromatic hydrocarbons (PAHs) in the field (Hamilton Harbour, Hamilton, Ont., Canada). Both the laboratory and field experiments demonstrated that, with the on-rod standardization technique, the PDMS rod can be successfully used as a passive sampler for TWA water sampling in the field. The PDMS rod passive sampler benefits from the inherent advantages of the SPME approach: it incorporates sampling, isolation and enrichment into one step. The design of this system also addressed the additional needs for passive sampling techniques, providing an economical approach to field sampling that is also easy to deploy. Rather, with this approach, TWA concentrations of target analytes can be obtained by one sampler, and can be analyzed directly, with no further sample preparation treatment required.

Chromatography, Liquid↗

Recent developments in the analysis of brominated flame retardants and brominated natural compounds.

This article reviews recent literature on the analysis of brominated flame retardants (BFRs) and brominated natural compounds (BNCs). The main literature sources are reviews from the last five years and research articles reporting new analytical developments published between 2003 and 2006. Sample pretreatment, extraction, clean-up and fractionation, injection techniques, chromatographic separation, detection methods, quality control and method validation are discussed. Only few new techniques, such as solid-phase microextraction (SPME) or pressurized liquid extraction (PLE), have been investigated for their ability of combining the extraction and clean-up steps. With respect to the separation of BFRs, the most important developments were the use of comprehensive two-dimensional gas chromatography for polybrominated diphenyl ethers (PBDEs) and the growing tendency for liquid-chromatographic techniques for hexabromocyclododecane (HBCD) stereoisomers and of tetrabromobisphenol-A (TBBP-A). At the detection stage, mass spectrometry (MS) has been developed as well-established and reliable technology in the identification and quantification of BFRs. A growing attention has been paid to quality assurance. Interlaboratory exercises directed towards BFRs have grown in popularity and have enabled laboratories to validate analytical methods and to guarantee the quality of their results. The analytical procedures used for the identification and characterization of several classes of BNCs, such as methoxylated polybrominated diphenyl ethers (MeO-PBDEs) (also metabolites of PBDEs), halogenated methyl or dimethyl bipyrroles (DBPs), are reviewed here for the first time. These compounds were generally identified during the routine analysis of BFRs and have received little attention until recently. For each topic, an overview is presented of its current status.

Analytic Sample Preparation Methods↗

Development of an SPME-GC-MS/MS method for the determination of pesticides in rainwater: laboratory and field experiments.

A solid-phase microextraction -- coupled to a gas chromatography -- ion trap tandem mass spectrometry (SPME-GC-MS/MS) method was developed for the quantitative determination in rainwater of 8 pesticides amongst the most used in France and 3 triazines metabolites. The main factors affecting the SPME process were studied. Using a 3 mL sample, the method developed showed good linearity for concentrations ranging from 0.05 to 50 microgL(-1) with correlation coefficients between 0.997 and 0.9999 and relative standard deviations (% RSD) below 14%. The study of matrix effects showed that rainwater was too diluted to have any significant influence on the extraction efficiency. To validate the method, a field campaign was carried out on the rain events, which occurred in Strasbourg during a one-year period. The rain concentrations showed patterns of high pesticide concentrations during spring months, which were correlated to the spraying periods of most of these substances.

Acetamides↗

Variation in 4-mercapto-4-methyl-pentan-2-one release by Saccharomyces cerevisiae commercial wine strains.

The volatile thiol 4-mercapto-4-methylpentan-2-one (4MMP) is a potent contributor to wine aroma. In grape juice, 4MMP is bound to cysteine as a non-volatile compound and requires the action of yeast during fermentation to release the aroma active thiol. A method was developed to measure 4MMP release from the precursor by headspace solid-phase microextraction and separation by gas chromatography with atomic emission detection to screen the ability of wine yeast to release 4MMP. Yeast commonly used in white wine making were grown with the precursor at two different temperatures, and the amount of 4MMP released was measured. The results demonstrate that yeast strain selection and fermentation temperature can provide an important tool to enhance or modulate the grape-derived aromas formed during wine fermentation.

Fermentation↗

Production of volatile organic sulfur compounds (VOSCs) by basidiomycetous yeasts.

Thirty-seven basidiomycetous yeasts belonging to 30 species of seven genera were grown on media containing l-cysteine or l-methionine as sole nitrogen sources with the objective of evaluating volatile organic sulfur compound (VOSC) production. The headspace of yeast cultures was analyzed by the solid-phase microextraction (SPME) sampling method, and volatile compounds were quantified and identified by GC-MS techniques. Ten strains assimilating L-methionine produced the following VOSCs: 3-(methylthio)-1-propanol, methanethiol, S-methyl thioacetate, dimethyl disulfide, dimethyl trisulfide, allyl methyl sulphide and 4,5-dihydro-3(2H)-thiophenone. Production was <1 mgl(-1) except for 3-(methylthio)-1-propanol of which between 40 and 400 mgl(-1) was synthesized. Higher alcohols (isobutyl alcohol, isoamyl alcohol and active amyl alcohol) and esters (ethyl acetate, ethyl propionate, n-propyl acetate, isobutyl acetate, n-propyl propionate, n-butyl acetate, isoamyl acetate, amyl acetate, isoamyl propionate, amyl propionate and 2-phenylmethyl acetate) were also sporadically produced. This is the first report of VOSCs production by basidiomycetous yeasts. Consequently, basidiomycetous yeasts may be considered an interesting new group of microbial VOSCs producers for the flavor industry.

Basidiomycota↗

Multi-omics insights into aroma formation in congou black tea during fermentation.

This study used multi-omics technologies to analyze aroma formation during Congou black tea fermentation. Volatile compounds were analyzed by headspace solid phase microextraction coupled with gas chromatography mass spectrometry using two columns of different polarity. Fermentation increased total volatile normalized peak area fivefold, with alcohols, aldehydes, and acids increasing over sevenfold. 29 differential metabolites were screened, including amino acid derived phenylacetaldehyde, phenylethanol, and 2-methylbutanal; fatty acid derived (E,E)-2,4-heptadienal, hexanal, and 1-hexanol; and isoprenoid derived linalool, geraniol, and beta ionone. Transcriptomic, proteomic, and enzyme analyses revealed that biosynthesis contributed to early accumulation of amino acid and isoprenoid derived aromas, whereas ortho quinone mediated Strecker degradation and free radical induced fatty acid auto oxidation dominated generation of amino and fatty acid derived aromas during middle and late fermentation. In conclusion, aroma formation during fermentation results from biosynthesis and non-enzymatic oxidation, with the latter possibly dominating amino and fatty acid derived aromas.

Fermentation↗

Wipe-test and patch-test for alcohol misuse based on the concentration ratio of fatty acid ethyl esters and squalene CFAEE/CSQ in skin surface lipids.

Fatty acid ethyl esters (FAEE) are known to be formed in blood and almost all human tissues after alcohol consumption and to be incorporated from sebum into hair where they can be used as long-term markers for excessive alcohol consumption. In order to examine whether skin surface lipids which consist mainly of sebum are an equally useful matrix for measurement of FAEE as alcohol abuse markers, samples were collected by a wipe-test from the forehead of 13 teetotallers, 16 social drinkers, 10 death cases with known recent alcohol misuse and five death cases without indications of alcohol misuse. The samples were analysed by headspace solid-phase microextraction and gas chromatography-mass spectrometry for ethyl myristate, ethyl palmitate, ethyl oleate and ethyl stearate and by high performance liquid chromatography with photodiode array detector for squalene, (SQ), as a natural reference substance which the FAEE concentrations were related to. The ratio mFAEE/mSQ ranged between 0.16 and 1.12 ng/microg (mean 0.34 ng/microg) for the teetotallers and between 0.08 and 0.94 ng/microg (mean 0.37 ng/microg) for the social drinkers with no significant difference between both groups. For the alcoholics 2.4-24.2 ng/microg (mean 13.1 ng/microg) were found. For two volunteers the course of mFAEE/mSQ 2 weeks before and 3 weeks after a single high alcohol dose was pursued by daily wipe tests. A strong increase of mFAEE/mSQ occurred between 7 and 12 days after the drinking event. This delay can be explained by the transition time of about 8 days between sebum production and its appearance on the skin surface known from literature. For seven social drinkers skin surface lipid samples were also collected using drug of abuse patches of the firm PharmCheck. The ratios mFAEE/mSQ in these samples were in the same range as from the wipe-test. The comparison with the self-reported ethanol amounts consumed the week before and during the test gave no good correlation (R2 = 0.42). It can be concluded from the results that FAEE in skin surface lipids can be used for medium-term retrospective detection of heavy drinking.

Adult↗

Comparison of ethyl glucuronide and fatty acid ethyl ester concentrations in hair of alcoholics, social drinkers and teetotallers.

In previous investigations hair analysis for ethyl glucuronide (EtG) and fatty acid ethyl esters (FAEE) proved to be suitable for the detection of excessive alcohol consumption. The aim of this study was to compare EtG and FAEE concentrations in hair of alcoholics, social drinkers and teetotallers. Hair samples from 10 alcoholics in withdrawal treatment, 11 fatalities with documented excessive alcohol consumption, four moderate social drinkers who consumed up to 20 g ethanol per day, and three strict teetotallers were analysed. After external degreasing with n-heptane, extraction with a dimethyl sulfoxide/n-heptane mixture and headspace solid-phase microextraction of the extracts, four fatty acid ethyl esters (FAEEs) (ethyl myristate, ethyl palmitate, ethyl oleate and ethyl stearate) were analysed by gas chromatography-mass spectrometry (GC-MS) with deuterated internal standards. EtG was determined by GC-MS/NCI after ultrasonication of the samples with H2O, cleanup by SPE with aminopropyl columns and PFP derivatisation. The following concentrations were measured for the four groups: teetotallers EtG < 0.002 ng/mg, FAEE 0.05-0.37 ng/mg, moderate social drinkers EtG < 0.002 ng/mg, FAEE 0.26-0.50 ng/mg, alcoholic patients EtG 0.030-0.415 ng/mg, FAEE 0.65-20.50 ng/mg and the fatalities with alcohol history EtG 0.072-3.380 ng/mg, FAEE 1.30-30.60 ng/mg. The results confirm that by using a cut-off value of the sum of FAEE > 1 ng/mg and/or a positive EtG result in hair, excessive alcohol consumption can be identified using hair analysis. However, no significant correlation between the EtG and FAEE concentrations in the positive cases could be shown. Segmental analysis of some of the specimens did not reveal the same distribution for EtG compared to FAEE in hair, and no chronological accordance compared to the self-reported alcohol consumption could be observed for both parameters. These different results of both methods are discussed in terms of differences between EtG and FAEE in mechanism of formation and incorporation into hair and elimination from hair.

Adult↗

New trends in hair analysis and scientific demands on validation and technical notes.

This review focuses on basic aspects of method development and validation of hair testing procedures. Quality assurance is a major issue in drug testing in hair resulting in new recommendations, validation procedures and inter-laboratory comparisons. Furthermore recent trends in research concerning hair analysis are discussed, namely mechanisms of drug incorporation and retention, novel analytical procedures (especially ones using liquid chromatography-mass spectrometry (LC-MS) and alternative sample preparation techniques like solid-phase microextraction (SPME)), the determination of THC-COOH in hair samples, hair testing in drug-facilitated crimes, enantioselective hair testing procedures and the importance of hair analysis in clinical trials. Hair testing in analytical toxicology is still an area in need of further research.

Forensic Toxicology↗

Urinary benzene determination by SPME/GC-MS. A study of variables by fractional factorial design and response surface methodology.

The urinary excretion of the unmetabolized benzene seems to be a very good index for biomonitoring benzene in occupationally exposed people. The use of solid phase microextraction (SPME) offers important advantages for its determination. Several variables can influence the benzene extraction process. Experimental design methodology was used to estimate the influence of the different variables and to evaluate the simultaneous effect of the more significant variables on the benzene extraction. The results showed that sample temperature, sample volume and their interaction were the more significant factors. A model was found that relates the amount of benzene extracted with the studied variables. The more adequate working conditions were: extraction temperature 15 degrees C, incubation time 1 min, extraction time 1 min and 2.5 ml of sample volume. The results indicate that this method is capable of providing sensitive and accurate results for the biomonitoring of benzene in urine.

Benzene↗

Monitoring of urinary acrolein concentration in patients receiving cyclophosphamide and ifosphamide.

Acrolein, the metabolite of cyclophosphamide and ifosphamide, irritates mucous membranes and is considered pathogenetically important in hemorrhagic cystitis. Increasing fluid intake or administering sodium 2-mercaptoethanesulfonate (mesna), a thiol compound, can reduce the risk of this complication. We measured urinary acrolein concentrations using headspace-solid-phase microextraction gas chromatography and mass spectrometry (headspace-SPME-GC-MS) in 19 patients receiving cyclophosphamide and ifosphamide (36 occasions). Peak acrolein concentrations occurred at 1-12h (mean +/- S.D., 5.0+/-2.7) after starting therapy, ranging from 0.3 to 406.8 nM (39.7+/-76.7), with varying patterns over time. Maintaining high urine volume was important for preventing increases in urinary acrolein concentration, as urinary acrolein concentration tended to rise as urine volume decreased. Urinalysis detected occult blood in three cases, but the patients had no clinical symptoms of hemorrhagic cystitis. In clinical trials involving cyclophosphamide and ifosphamide, monitoring of urinary acrolein concentration could indicate when to take heightened preventive measures against hemorrhagic cystitis.

Acrolein↗

The study of fingerprint characteristics of the emanations from human arm skin using the original sampling system by SPME-GC/MS.

An efficient and noninvasive method consisting of an original sampling device, solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) was developed to analyze volatile organic emanations from the skin of human arms. The emanations were sampled by SPME connected with the active sampling device for 30 min and transferred into GC-MS immediately for the consequent analysis. The sampling projects for 15 candidates were scheduled in both winter and spring with the same optimized conditions. Thirty-five compounds were finally identified according to various degrees of certainty. Different emission behaviors specified with principal component analysis (PCA) and similar fingerprint characteristics were observed clearly by comparisons of chromatograms of different seasons. Top ten emanations contributing to characteristics in different seasons were attempted to be described using comparisons based on common model strategy. The large amounts of experimental data were all handled by the corresponding chemometrics strategies with the homemade chromatographic data processing system. The results suggest that the analysis based on fingerprint characteristics of human skin emanations could provide useful and important clues to reveal biomarkers among the mixture of human skin emanations.

Alcohols↗

Degradation of polycyclic aromatic hydrocarbons in aqueous solutions by ultrasonic irradiation.

The effect of various operating conditions (initial concentration, liquid phase temperature, applied power, ultrasound frequency) and of the presence of matrix components (1-butanol, NaCl and FeSO(4)) on the sonochemical degradation of naphthalene, acenaphthylene and phenanthrene in water has been studied. A horn-type sonicator was used to deliver the ultrasound energy, while immersion sampling solid-phase microextraction (SPME) coupled with GC-MS was employed to follow concentration-time profiles of the chosen PAHs. At the operating conditions in question (initial concentrations of 150, 300 and 450 microg/l, temperatures of 20 and 40 degrees C, applied power of 45, 75 and 150 W and ultrasound frequencies of 24 and 80 kHz), all PAHs were susceptible to sonochemical treatment and, in most cases, complete degradation could be achieved in up to 120 min of treatment. Conversion was found to decrease with increasing initial concentration and temperature and decreasing power and frequency as well as in the presence of an excess of dissolved salts. Addition of 1-butanol, a known hydroxyl radical scavenger, substantially suppressed degradation throughout the course of the reaction, thus highlighting the role of oxidation reactions in PAHs degradation. In contrast, addition of Fe(2+) ions at a low concentration enhanced degradation through a Fenton-like reaction.

Gas Chromatography-Mass Spectrometry↗