PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “STAMPS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71Linked to original sources

Field verification methodology using bar coding to record data.

Bar codes, the ubiquitous labels on consumer products, can be used to record patient care data. Bar code entry offers precise, time-stamped, data records. Bar code readers, coupled with a personal computer, can produce an electronic medical record as well as analyze data trends.

Data Collection↗

Accuracy of bar codes versus handwriting for recording trauma resuscitation events.

STUDY OBJECTIVES: To compare the accuracy of computerized bar code data entry with conventional handwritten data entry during videotaped trauma resuscitations. SETTING: Laboratory; video simulation. TYPE OF PARTICIPANTS: Twenty-four emergency nurses. DESIGN: The nurses viewed videotapes of four different major trauma resuscitations during a single session. Each nurse recorded resuscitation events by handwritten entry in two cases and by bar code entry in another two. A computerized bar code system was designed specifically for contemporaneous charting of rapidly occurring events during trauma resuscitations. The handwritten and bar-coded records then were compared with a master list of events, and the number of entry errors were counted. Errors were defined as "omissions" (failing to record an event), "commissions" (recording an event that did not occur), or "inaccuracies" (errors in recording details of an event). ANALYSIS: Differences in the number of entry errors between the two recording methods were compared using unpaired t-tests. Differences in the number of errors after adjusting for the different nurses, different case being viewed, and order of viewing were analyzed using balanced analysis of variance techniques. P < .05 was considered significant. MAIN RESULTS: The mean +/- SEM number of total errors per record for bar codes was 2.63 +/- 0.24 compared with 4.48 +/- 0.30 for handwriting (P < .0001). The mean number of omissions per record for bar codes was 2.25 +/- 0.21 compared with 3.65 +/- 0.27 for handwriting (P = .0001). The mean number of inaccuracies per record for bar codes was 0.38 +/- 0.10 compared with 0.83 +/- 0.12 for handwriting (P = .0038). There were no commission-type errors. CONCLUSION: Computerized bar code data entry of trauma resuscitation events had significantly fewer entry errors than handwritten data entry in a laboratory setting. Potential advantages of bar code data entry include keyless data entry, automatic time-stamping, standardization of documentation, legibility of the medical record, and "point-of-care" data capture.

Electronic Data Processing↗

Does anybody really know what time it is? Does anybody really care?

STUDY OBJECTIVE: To evaluate the difference among time sources in an emergency medical system. DESIGN: Prospective; comparison to a criterion standard. SETTING: Five emergency departments and three emergency medical services systems in Indianapolis, Indiana. INTERVENTIONS: Coordinated Universal Time (UTC), generated by the atomic clock in Boulder, Colorado, and broadcast by the US Commerce Department's National Institute of Standards and Technology, was used as the time standard. The investigators, on a single day, made unannounced visits to the five EDs and the ambulances and fire stations in the three emergency medical services systems. The times displayed on all time sources at each location were recorded. The accuracy to the second of each time source compared to UTC was calculated. RESULTS: Three time sources were excluded (two defibrillator clocks and one ED wall clock that varied more than three hours from UTC). Of the 152 time sources, 72 had analog displays, 74 digital, three both, and three other. The average absolute difference from UTC was 1 minute 45 seconds (SEM, 9 seconds) with a range of 12 minutes 34 seconds slow to 7 minutes 7 seconds fast. Thus, two timepieces could have varied by as much as 19 minutes 41 seconds. Compared to UTC, 47 timepieces (31%) were slow, 100 (66%) were fast, and five (3%) were accurate to the second. Fifty-five percent of the time sources varied one minute or more from UTC. CONCLUSION: Time sources in this health care system varied considerably. Time recording in medicine could be made more precise by synchronizing medical clocks to UTC, using computers to automatically "time stamp" data entries and using only digital time sources with second displays.

Bias↗

Patient compliance with paper and electronic diaries.

Paper diaries are commonly used in health care and clinical research to assess patient experiences. There is concern that patients do not comply with diary protocols, possibly invalidating the benefit of diary data. Compliance with paper diaries was examined with a paper diary and with an electronic diary that incorporated compliance-enhancing features. Participants were chronic pain patients and they were assigned to use either a paper diary instrumented to track diary use or an electronic diary that time-stamped entries. Participants were instructed to make three pain entries per day at predetermined times for 21 consecutive days. Primary outcome measures were reported vs actual compliance with paper diaries and actual compliance with paper diaries (defined by comparing the written times and the electronically-recorded times of diary use). Actual compliance was recorded by the electronic diary. Participants submitted diary cards corresponding to 90% of assigned times (+/-15 min). However, electronic records indicated that actual compliance was only 11%, indicating a high level of faked compliance. On 32% of all study days the paper diary binder was not opened, yet reported compliance for these days exceeded 90%. For the electronic diary, the actual compliance rate was 94%. In summary, participants with chronic pain enrolled in a study for research were not compliant with paper diaries but were compliant with an electronic diary with enhanced compliance features. The findings call into question the use of paper diaries and suggest that electronic diaries with compliance-enhancing features are a more effective way of collecting diary information.

Adolescent↗

[Can or should blood pressure be measured at pharmacy offices?].

OBJECTIVE: To evaluate concordance between blood-pressure (BP) measurements at the pharmacy office (PhO) and the nurse office (NO) in the health care centre (HCC). DESIGN: Descriptive study. SETTING: Community. METHODS: 36 PhO have voluntarily participated in the province of Albacete, where they have done 3 BP measures, without previous instructions and with their usual measurements devices, for 3-5 subjects, who were referred to their HCC so that they were taken another 3 BP measures in the NO with their Hg sphymomanometer and in their usual measure conditions (blind measures in relation to those taken at the PhO). These subjects were given a stamped envelope to send the BP measurements (taken at the NO), to the Official Pharmacy College. RESULTS: The 6 BP measurements have been completed to 96 subjects with an average of 57.3 years old (women 63%). The differences between PhO and NO were > 5 mmHg in 58 subjects (60.4%) in the case of SBP and in 45 subjects (46.9%) in the case of DBP, and it was more than 15 mmHg in the 17 subjects (17.7%) with SBP and in 9 subjects (9.4%) with DBP. The difference average was 9.5 mmHg (SD, 8.4 mmHg) and 6.4 mmHg (SD, 5.3 mmHg) respectively. The use rate of digit 0 was 22% at the PhO and 46.5% at the NO. In most of PhO, measurement electronic devices have been used for the BP, but not validated for clinical use. CONCLUSIONS: The PhO can be a good place for the hypertension screening, but the chemist must be trained in the BP correct measurement and use validated electronic devices. Standardization measurement conditions and the use of validated electronic devices must be extended to the NO.

Blood Pressure Determination↗

[Infection in patients with neutropenia that undergo an autologous peripheral blood stem cell transplant due to breast cancer].

BACKGROUND: The extent and duration of neutropenia and the characteristics of the underlying disease are determinant factors for the prognosis of febrile syndromes. Despite the fact that traditionally the peripheral blood stem cell transplantation (PBSCT) were considered to cause high risk neutropenia, in all probability the neutropenia observed in the PBSCT in some solid tumours could be considered moderate risk. Febrile episodes in patients with these characteristics were evaluated. METHODS: We prospectively analysed 132 autologus PBSCT in patients with breast cancer (1994-1999). Conditioning regime: STAMP V. Antibacterial prophylaxis: ofloxacin (400 mg/12 hrs PO). Classification of the febrile syndrome: bacteremia, microbiologically documented infection withut bacteremia, clinical infection and a fever of unknown origin. RESULTS: 122 patients had a fever (92%), mean age: 45 years (range: 27-61). There were 32 (26%) bacteremias, 13 (11%) microbiologically documented infections without bacteremia and 54 (44%) clinical infections. The mean number of days with a neutrophil count of <1x109/1 was 14 (range: 11-20). In the 74 patients (61%) that had a granulocyte colony stimulating factor (G-CSF), the mean number of days to reach a 0,5x109/I neutrophil count (7,6) and the average number of days in hospital (26) were significantly less. There was a main infectious point in 80 patients (65%): the most frequent being oropharynx in 33 cases (46%) and digestive in 29 cases (41%). 48 gram negative (GN) 29 gram positive (GP) bacteria were isolated (71% of the GN's were resistant to ofloxacin). Between 1997-1999 the GN/GP ratio was 2,3. There were no deaths related to the infection. CONCLUSIONS: Given the excellent evolution of our patients we can consider their neutropenia to be moderate or low risk, and they are a long way from the death rates caused by infections published by other types of hemopoietic transplants. The predominance of GN over the last few years and their limited sensitivity to quinolones means that their prophylactic use in these patients should be reconsidered.

Acyclovir↗

System to monitor task chair seating.

OBJECTIVE: To record chair data such as seat occupancy, back recline angle, lumbar engagement, and armrest location using an independent, unbiased real time data acquisition system. DESIGN: The system should be inconspicuous. The users should be able to work effectively in their environment oblivious to concurrent data collection. BACKGROUND: While human acquisition and measurement instruments provide an acceptable approach for collecting data on changing chair positions, they may bias data. Current data collection methods such as video playback can also be successful in collecting chair data, but are often time-consuming and expensive to set up. METHODS: Four key areas were concentrated upon for monitoring: seat, lumbar, back recline, and armrest position. A position switch was mounted to each locale and linked to a microprocessor to track the changing positions of the chair in real time. RESULTS: The chair provides time stamped data on the changes that take place to the chair. The data can be downloaded at the convenience of the user and researcher. CONCLUSIONS: The chair is complete and ready for data acquisition. It permits easy data collection on chair positions without hindering the user's movement. RELEVANCE: This tool provides an automated, independent method for collecting data on chair positions. Information can be collected and studies conducted on seated durations, chair back motion while seated, chair lumbar usage, and common armrest location while in a visual display terminal workstation.

Data Collection↗

Universal polycarbonate fracture splint and its direct bonding potential.

A polycarbonate splint has been presented which offers the advantage of the ability of being bonded and/or wired into place. This new type of splint offers several advantages over traditional steel splints. The splint can be bonded and/or wired to the dental arch; the bonding method can be a time-saver. The polycarbonate material is readily malleable and does not possess an intrinsic tension or spring usually found in plastics when they are bent or shaped. The splint is highly esthetic when compared to steel splints. Polycarbonate splints are more economical than steel splints. Molded plastic surfaces are smoother and are more compatible with the oral mucosal than the stamped steel surfaces. Finally, and most importantly, the patient acceptance of polycarbonate splints appears to be very good in comparison with steel splints. The above advantages seem to indicate that the future acceptance of this type of splint for maxillofacial injuries will be good, although, it should be understood that plastic splints are not as strong as steel splints and may occasionally break after several weeks of use. Breakage, however, may not cause the splint to become unusable and usually does not occur until after the 4th week of use, if at all.

Acid Etching, Dental↗

The effects of pegylated recombinant human megakaryocyte growth and development factor (PEG-rHuMGDF) on platelet recovery in breast cancer patients undergoing autologous bone marrow transplantation.

OBJECTIVE: To assess the safety and efficacy of pegylated recombinant human megakaryocyte growth and development factor (PEG-rHuMGDF) administered after autologous bone marrow transplantation (ABMT). PATIENTS AND METHODS: Two randomized, double-blind, placebo-controlled studies were done. In the phase 1/2 study, 75 breast cancer patients underwent a bone marrow harvest and myeloablative STAMP V chemotherapy and were randomized to receive placebo or one of three doses of PEG-rHuMGDF. In the phase 3 study, 64 patients were randomized to receive placebo or the minimally effective dose of PEG-rHuMGDF. The study drug was administered daily starting on the day of bone marrow infusion until the platelet count was greater than or equal to 50 x 10(9)/L (without transfusion) or for a maximum of 28 days. All patients received 10 microg/kg/day filgrastim starting on day 2 until neutrophil count recovery. RESULTS: PEG-rHuMGDF appeared to be safe and well tolerated. No significant differences were noted in mortality or disease progression rates. Antibodies to MGDF were not observed. In the phase 1/2 study, the time to platelet recovery to greater than or equal to 20 x 10(9)/L and platelet transfusion requirements were significantly reduced for patients treated with PEG-rHuMGDF compared with placebo (p < 0.05). In the phase 3 study, no significant differences in the kinetics of early thrombopoiesis or platelet transfusions after ABMT were observed. CONCLUSIONS: PEG-rHuMGDF was not consistently efficacious in reducing the duration of severe thrombocytopenia. The maximum platelet counts for PEG-rHuMGDF-treated patients occurred a median of 2 weeks after the last dose of drug, suggesting that the biologic effects of this hematopoietic cytokine are delayed compared with other hematopoietic cytokines.

Adult↗

Probing nanoscale surface enhanced Raman-scattering fluctuation dynamics using correlated AFM and confocal ultramicroscopy.

We have studied the laser-excitation-intensity-dependent and Ag-nanocluster interstitial-site-dependent SERS intensity fluctuations under low molecule surface coverage of rhodamine 6G and cytochrome c. A new two-channel photon time-stamping system coupled with atomic force microscopic (AFM), Raman spectroscopic, and imaging microscopy was developed and applied to record Raman intensity fluctuation trajectories at sub-microsecond resolution correlated with in situ characterization of the nanoparticle clusters. Our experimental results suggest that the nanoconfinement of the local electromagnetic-field enhancement and the interaction of the local field with the molecules, presumably under rotational motions, result in nano-Raman fluctuations. The SERS spectral fluctuation was pertinent to the nanoscale local enhancement and local interaction of the molecules with the surface when the surface coverage of the nanoparticles was less than a monolayer, and the nanoscale interstitial space controlled the finite number of molecules to contribute the microscopic Raman signal collected from a diffraction-limited focus spot. The fluctuation amplitude significantly decreased with the number of molecules confined at the nanolocal field. The nano-SERS fluctuation dynamics were both photo-induced and spontaneous for rhodamine 6G, but only the photo-induced component was observable for cytochrome c. The fluctuation dynamics were also found to be highly inhomogeneous at interstitial sites with heterogeneous geometries. To interpret the observed nano-SERS fluctuation dynamics, we used computer simulation of optical multiple scattering, based on multi-sphere scattering Mie theory, and rotational diffusion of molecules at an interstitial site, based on a random walk in orientation space.

Journal Article↗

A European hospital survey to determine the extent of psychological services offered to patients with severe burns.

Analogous to a hospital survey in North America (the US and Canada) a survey in Europe was performed to determine the extent of psychological services offered in burn units. The questionnaire used to acquire this information was exactly the same in both continents. One hundred and seventy questionnaires and self-addressed stamped envelopes were sent to the medical manager of the European burn units with the request to pass the questionnaire to the person who provides psychological care to patients in the burn units. The questionnaire was translated into four other languages. Response was 103 (62.8%). The questions posed inquired after what percentage of patients received psychological testing, psychological therapy, displayed symptoms of depression and post-traumatic stress, what percentage is given referral and if emotional follow-up is arranged. Also questions about whether staff members of the burn unit displayed symptoms of depression and post-traumatic stress were enclosed. Results indicated that few burn units in Europe provide formal psychological testing for their patients and in half of the European hospitals, less than 20% of the patients receive psychological therapy or counselling during their stay in the hospital. Aftercare services are also capable of improvement. Compared with North America, Europe provided less psychological services. No statistical differences were found between countries within Europe.

Burn Units↗

Expansion technique for skin grafts (Meek technique) in the treatment of severely burned patients.

The important limiting factor in the treatment of the severely burned patient is the lack of autograft donor skin. The method of obtaining uniform widely expanded postage stamp autografts described by Meek in 1963 has been evaluated in this study amongst seven severely burned patients. The expansion ratio of 1:4, 1:6, 1:9 was mostly used. After the removal of polyamide gauze on seventh post-operative day the autografts island were covered with overlay allograft, if the expansion ratio of 1:6 and above was used. The mean epithelialization rate was 90% within 4-5 weeks. The preliminary experience suggests, and proves that, it is a method of choice in severely burned patients.

Adolescent↗

Antibiotic prophylaxis--Hobson's choice in burns management.

Antibiotic prophylaxis is a routine procedure in management of burns. As such it is a safe practice, yet unusual complications can occur with the use of even safest antibiotics and their emergency management may be life saving. Here we present a case of 35% second and third degree burns who was taken for a second sitting of stamp grafting for remnant raw areas, who was administered intraoperative prophylactic antibiotic, developed a series of unusual complications sequentially, which were life threatening. Prompt recognition of signs and symptoms of adverse reactions of the drug used and timely management resulted in the successful outcome. A good team effort by surgeon, anaesthetist and the physician was mandatory.

Adult↗

Progression of burn wound depth by systemical application of a vasoconstrictor: an experimental study with a new rabbit model.

The final depth of a necrosis resulting from burn trauma is determined within 3 days. The zone of stasis has the potential for complete regeneration or there may be ischemic influences that lead to necrosis. In our model, we examined the dermal influence of vasoconstrictors with reference to the development of burn necrosis. On the backs of New Zealand white rabbits (4.0-4.5 kg) standardized lesions were made with a heated aluminum stamp at 80 degrees C, 14 s in duration. The lesions were intradermal, whereby the border zone of the coagulated tissue was found in the middle two quarters of the dermis in 100% of untreated animals after 72 h. For dermal vasoconstriction epinephrine in a dose of 0.5 microg/kg/min was used. There were two groups of seven animals each. One group received epinephrine and the dosage was dependent on the clinical state of the animal. Several cycles were administered within a 3-day period. The reduction of skin perfusion was documented by Laser-Doppler-flowmetry. After 3 days, the skin with the lesions was excised and using a hematoxylin dye, a histological examination followed. The parameter used to determine the efficacy was the thickness of the uncoagulated part of the excised dermis. Over a period of 48 h, an average of 2.3 epinephrine cycles of average of 88 min per animal in duration resulted in an average reduction of skin diffusion of 41%. The uncoagulated part of the dermis in the epinephrine group was 28.6% average; in the control group, this was 43.5%. The statistical analysis revealed significant differences with a p-value of 0.0312 (significant, when value is less than 0.05). The test results indicate that temporary reduction of skin perfusion through external administration of vasocontrictors may lead to progression of burn necrosis in our animal model. Clinically, this result indicates that for patients with burn injuries and systemic inflammatory response syndrome who have insufficient volume therapy, the administration of vasocontrictors may produce similar results in the injured area.

Administration, Topical↗

Salivary cortisol sampling compliance: comparison of patients and healthy volunteers.

OBJECTIVE: Problems of compliance with in vivo data collection and treatment protocols have been identified. This study investigated compliance with salivary cortisol sampling in a 7-day protocol. Impact of non-compliance on cortisol data was evaluated. METHODS: Female fibromyalgia patients were matched with healthy female volunteers and randomized to Aware or Unaware conditions regarding objective monitoring of their sampling compliance. The protocol entailed collecting five saliva samples at prescribed times on each of 7 consecutive days. Participants self-reported time of each sample, and electronic monitor caps provided an objective date and time stamp of each sample. RESULTS: Objective compliance among participants unaware of monitoring was 71%, though their self-reported compliance was 93%. Aware participants' objective compliance was 90% which was consistent with self-reported compliance of 93%. Within-subject comparison of early morning rise and day slope of cortisol for compliant and non-compliant samples found significant differences with non-compliant samples resulting in flatter slopes. Patients were somewhat more compliant than healthy volunteers. Slight decrements in compliance were found for the afternoon sample (1600 h) and for the last 3 days of sampling. Compliance did not differ on weekdays versus weekends. CONCLUSIONS: Self-report of compliance in a salivary cortisol sampling protocol substantially overestimates actual compliance in the absence of objective monitoring. Non-compliance with the sampling protocol results in cortisol data that significantly differs from compliant data. Awareness of electronic monitoring of sampling results in satisfactory compliance.

Adult↗

Erectile function after permanent prostate brachytherapy.

PURPOSE: To determine the incidence of potency preservation after permanent prostate brachytherapy using a validated patient-administered questionnaire and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. MATERIALS AND METHODS: Four hundred twenty-five patients underwent permanent prostate brachytherapy from April 1995 to October 1999. Two hundred nine patients who were potent before brachytherapy and who at the time of the survey were not receiving hormonal therapy were mailed the specific erectile questions of the International Index of Erectile Function (IIEF) questionnaire with a self-addressed stamped envelope. The questionnaire consisted of 5 questions, with a maximal score of 25. Of the 209 patients, 181 (87%) completed and returned the questionnaire. The mean and median follow-up was 40.4 +/- 14.9 and 40.6 months, respectively (range 19-75). Preimplant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Postimplant potency was defined as an IIEF score >/=11. The clinical parameters evaluated for erectile function included patient age, preimplant potency, clinical T-stage, pretreatment prostate-specific antigen level, Gleason score, elapsed time after implantation, hypertension, diabetes mellitus, and tobacco consumption. Treatment parameters included radiation dose to the prostate gland, use of hormonal manipulation, use of supplemental external beam radiotherapy (EBRT), choice of isotope, prostate volume, and planning volume. The efficacy of sildenafil citrate in brachytherapy-induced erectile dysfunction (ED) was also evaluated. RESULTS: Pretreatment erectile function scores of 2 and 1 were assigned to 125 and 56 patients, respectively. With a 6-year follow-up, 39% of patients maintained potency after prostate brachytherapy, with a plateau on the potency preservation curve. Postimplant preservation of potency (IIEF >/=11) correlated with preimplant erectile function (50.4% vs. 13.2% for preimplant scores of 2 and 1, respectively, p <0.001), patient age (57.4%, 38.2%, and 21.9% for patients <60, 60-69, and >/=70 years old, respectively, p <0.004), use of supplemental EBRT (52.0% vs. 26.4% for patients without and with EBRT, p <0.001), and a history of diabetes mellitus (41.4% vs. 0% for patients without and with diabetes, respectively, p = 0.017). In multivariate analysis, clinical stage, radiation dose to the prostate gland, hormonal manipulation, choice of isotope, history of hypertension, and tobacco consumption had no effect on the ultimate preservation of potency. Only the preimplant potency score, use of supplemental EBRT, and diabetes maintained statistical significance. Sixty-two patients used sildenafil, with 53 (85%) reporting a favorable response. When potent patients were grouped with the ED patients who used sildenafil, the 6-year actuarial rate of potency preservation was 92%. Including the 70 impotent patients who never used sildenafil, the actuarial 6-year rate of potency preservation with and without pharmacologic support was 54% and 39%, respectively. CONCLUSION: Our results suggest that brachytherapy-induced ED is more common than previously reported and may be the result of obtaining patient information by means of a validated quality-of-life instrument by mail and not by personal interview. In multivariate analysis, only pretreatment potency, supplemental EBRT, and diabetes maintained statistical significance. Most patients with brachytherapy-induced ED responded favorably to sildenafil. Although the 6-year actuarial incidence of potency preservation was 39%, 52% of patients not receiving supplemental EBRT maintained potency. In addition, with pharmacologic support, 92% of patients maintained potency.

Adenocarcinoma↗

Progressive ultrastructural changes after peripheral nerve transection and repair.

Six rhesus monkeys (Macaca mulatta) underwent sharp transection and repair of the intrinsic motor fascicles of both ulnar nerves in order to determine the sequential events during reinnervation of the distal stamp. Light and electron microscopic sections were made at 2.0 mm increments distal to the neurorrhaphy at weekly intervals in separate monkeys. Neurite sprouts could be identified distal to the neurorrhaphy by 1 week and were clearly evident 40 mm distal by 3 weeks. Although some old endoneurial tubules persisted, they were less often used as conduits or scaffolds for the regenerating neurites than previously described. Most new fibers, whether myelinated or unmyelinated, passed down new endoneurial tubules, thus precluding perfect end-organ specificity because the regenerating neurites seldom utilized old endoneurial tubules. The clinical implication suggested by this study is that the ideal situation is the immediate repair of transected nerves. This allows neurite sprouts to cross a neurorrhaphy rapidly and reinnervate end organs.

Animals↗

Courtship behaviour in a lekking species: individual variations and settlement tactics in male little bustard.

We analysed the display behaviour of male little bustard Tetrax tetrax to identify displays that are used in the context of male-male competition and those that are used for attracting females. Courtship was the main activity of males during the breeding season. Calling activity occurred throughout the day, and leks were attended for more than 4 months. Male sexual displays included snort call, wing-flash, and jump display. Snort call was performed throughout the day and mainly involved male-male interactions. In contrast, the wing-flash display was given only at twilight, and was performed most commonly when a female was present, supporting an inter-sexual function for this display. The jump display was performed only in the presence of female at anytime of the day. Analysis of individual variations in display behaviour revealed that intra-individual variation was low compared to inter-individual variation, especially for the jump display. It is, therefore, possible that display rates provide information on male quality. Four male settlement patterns could be defined, singles, paired, lekking and satellite lekking, but only wing-flash display and stamped snort call differed among those categories. We suggest that satellite males are attempting to benefit from proximity to higher status males, in accordance with the hotshot hypothesis of lek evolution.

Journal Article↗