PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “surface modification”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71Linked to original sources

Aminooxy pluronics: synthesis and preparation of glycosaminoglycan adducts.

Novel biomaterials have been prepared in which glycosaminoglycans (GAGs) are chemically modified to create amphiphilic multiblock copolymers that are able to adhere to hydrophobic surfaces and can self-assemble into cross-linker-free hydrogels. First, the triblock poly(ethylene oxide)-polypropylene oxide copolymers (Pluronics) were converted into the previously unknown aminooxy (AO) derivatives. Both mono-AO and bis-AO Pluronics (AOPs) were synthesized and fully characterized in order to prepare tetrablock and pentablock copolymers, respectively. Second, the AOPs were coupled to the uronic acid carboxylates of heparin (HP) and hyaluronic acid (HA) using carbodiimide chemistry in order to give the previously undescribed amidooxy GAG derivatives. The coupling chemistry was confirmed using a newly prepared fluorescent AO reagent. Third, AOP-heparin and AOP-fluorescently labeled heparin were shown to adsorb efficiently to polystyrene surfaces, as determined by IL-8 based ELISA and fluorescence measurements, respectively. Fourth, AOP-linked fluorescently labeled HA was shown to adsorb efficiently to plastic surfaces. Finally, three different AOPs were evaluated for self-assembling hydrogel formation by AOP-HA pentablock polymers. In short, AOP-GAG adducts are semisynthetic amphiphilic biomacromolecules that offer a range of valuable practical opportunities for surface modification, preparation of cross-linker-free hydrogels, and formation of self-assembling mimics of the extracellular matrix.

Carbodiimides↗

Artificial heart valves: improved blood compatibility by PECVD a-SiC:H coating.

Implants are steadily increasing in importance as substitutions for body functions. With the present state of the art, the limitations of the application of cardiovascular implants are due to insufficient performance of biomaterials. Present research in this field is being concentrated on efforts to improve the thrombus resistance of conventional materials by coating with semiconducting materials to actively influence the electrochemical interaction between the condensed matter and blood proteins. Based on an electrochemical model of the interaction of fibrinogen with an artificial surface and the resulting requirements for improving hemocompatibility, a coating of amorphous hydrogenated silicon carbide deposited by plasma-enhanced chemical vapor deposition (PECVD) is presently under evaluation as a special coating material for cardiovascular prostheses and is herein described. In particular, first results are published concerning the optimum deposition parameters in the PECVD process and cell culture tests. Experimental results of comparative partial thromboplastin time studies serve the purpose of proving the validity of the electrochemical reaction model referring the hemocompatibility of implantable materials to their semiconducting surface properties. The aim of this article is to demonstrate a feasible method for an antithrombogenic surface modification based on doped amorphous silicon carbide films that is in full conformance to the above mentioned model.

Biocompatible Materials↗

The surface functionalization of 45S5 Bioglass-based glass-ceramic scaffolds and its impact on bioactivity.

The first and foremost function of a tissue engineering scaffold is its role as a substrate for cell attachment, and their subsequent growth and proliferation. However, cells do not attach directly to the culture substrate; rather they bind to proteins that are adsorbed to the scaffold's surface. Like standard tissue culture plates, tissue engineering scaffolds can be chemically treated to couple proteins without losing the conformational functionality; a process called surface functionalization. In this work, novel highly porous 45S5 Bioglass-based scaffolds have been functionalized applying 3-AminoPropyl-TriethoxySilane (APTS) and glutaraldehyde (GA) without the use of organic solvents. The efficiency and stability of the surface modification was assessed by X-ray photoemission spectroscopy (XPS). The bioactivity of the functionalized scaffolds was investigated using simulated body fluid (SBF) and characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). It was found that the aqueous heat-treatment applied at 80 degrees C for 4 hrs during the surface functionalization procedure accelerated the structural transition of the crystalline Na2Ca2Si3O9 phase, present in the original scaffold structure as a result of the sintering process used for fabrication, to an amorphous phase during SBF immersion. The surface functionalized scaffolds exhibited an accelerated crystalline hydroxyapatite layer formation upon immersion in SBF caused by ion leaching and the increased surface roughness induced during the heat treatment step. The possible mechanisms behind this phenomenon are discussed.

Biocompatible Materials↗

Micropatterning of DNA-tagged vesicles.

We present a novel concept for the creation of lipid vesicle microarrays based on a patterning approach termed Molecular Assembly Patterning by Lift-off (MAPL). A homogeneous MAPL-based single-stranded DNA microarray was converted into a vesicle array by the use of vesicles tagged with complementary DNAs, permitting sequence-specific coupling of vesicles to predefined surface regions through complementary DNA hybridization. In the multistep process utilized to fulfill this achievement, active spots consisting of PLL-g-PEGbiotin with a resistant PLL-g-PEG background, as provided by the MAPL process, was converted into a DNA array by addition of complexes of biotin-terminated DNA and NeutrAvidin. This was then followed by addition of POPC vesicles tagged with complementary cholesterol-terminated DNA, thus providing specific coupling of vesicles to the surface through complementary DNA hybridization. Quartz crystal microbalance with dissipation (QCM-D) and optical waveguide lightmode spectroscopy monitoring were used to optimize the multistep surface modification process. It was found that the amount of adsorbed biotinDNA-NeutrAvidin complexes decreases with increasing molar ratio of biotinDNA to NeutrAvidin and decreasing ionic strength of the buffer solution. Modeling of the QCM-D data showed that the shape of the immobilized vesicles depends on the amount of available anchoring groups between the vesicles and the surface. Fluorescent microscopy images confirmed the possibility to create well-defined patterns of DNA-tagged, fluorescently labeled vesicles in the micrometer range.

Biotin↗

Heterobifunctional membranes by plasma induced graft polymerization as an artificial organ for penetration keratoprosthesis.

Highly biocompatible polymer membrane was developed for an artificial cornea in this surface modification study. Heterobifunctional silicone rubber membranes (hetero-SR) were prepared by grafting different functional polymers on each side of a silicone rubber membrane (SR). A novel type of bifunctional membrane was developed with the upper-side favoring cell attachment and growth, and the lower-side suppressing cell adhesion. The preparation of heterobifunctional membranes, characterization of polymer membrane surface properties such as ATR-FTIR and ESCA and contact angle, and biological analysis (in vitro and in vivo studies) were investigated in this work. Based on the biological analysis, the heterobifunctional membrane displays promising potential for use as an artificial cornea.

Adsorption↗

Staphylococcus aureus adhesion to titanium oxide surfaces coated with non-functionalized and peptide-functionalized poly(L-lysine)-grafted-poly(ethylene glycol) copolymers.

Implanted biomaterials are coated immediately with host plasma constituents, including extracellular matrix (ECM); this reaction may be undesirable in some cases. Poly(L-lysine)-grafted-poly(ethylene glycol) (PLL-g-PEG) has been shown to spontaneously adsorb from aqueous solution onto metal oxide surfaces, effectively reducing the degree of non-specific adsorption of blood and ECM proteins, and decreasing the adhesion of fibroblastic and osteoblastic cells to the coated surfaces. Cell adhesion through specific peptide-integrin receptors could be restored on surfaces coated with PLL-g-PEG functionalized with peptides of the RGD (Arg-Asp-Gly) type. To date, no study has examined the effect of surface modifications by PLL-g-PEG-based polymers on bacterial adhesion. The ability of Staphylococcus aureus to adhere to the ECM and plasma proteins deposited on biomaterials is a significant factor in the pathogenesis of medical-device-related infections. This study describes methods for visualizing and quantifying the adhesion of S. aureus to smooth and rough (chemically etched) titanium surfaces without and with monomolecular coatings of PLL-g-PEG, PLL-g-PEG/PEG-RGD and PLL-g-PEG/PEG-RDG. The different surfaces were exposed to S. aureus cultures for 1-24h and bacteria surface density was evaluated using scanning electron microscopy and fluorescence microscopy. Coating titanium surfaces with any of the three types of copolymers significantly decreased the adhesion of S. aureus to the surfaces by 89-93% for PLL-g-PEG, and 69% for PLL-g-PEG/PEG-RGD. Therefore, surfaces coated with PLL-g-PEG/PEG-RGD have the ability to attach cells such as fibroblasts and osteoblasts while showing reduced S. aureus adhesion, resulting in a selective biointeraction pattern that may be useful for applications in the area of osteosynthesis, orthopaedic and dental implantology.

Bacterial Adhesion↗

Assessment of porous silicon substrate for well-characterised sensitive DNA chip implement.

A biochip approach based on porous silicon as substrate is presented. The goal is to enhance the sensitivity of the biochip by increasing the specific surface area on the support. The elaboration of porous silicon layers has been optimized to guarantee good accessibility for large bio-molecule targets. Oligonucleotide probes are synthesised directly on the surface using phosphoramidite chemistry. The high specific surface area of porous silicon allows the direct characterisation, by infrared spectroscopy, of the porous layer formation and the functionalisation steps. The monolayer grafting and derivatisation protocol is additionally characterized by wettability and fluorescence microscopy. The surface modification of porous layers (i.e. thermal oxidation and chemical derivatisation) ensures the stability of the structure against strong chemical reagents used during the direct oligonucleotide synthesis. Finally the protocol is successfully transferred to a flat Si/SiO(2) substrate, and validated by biological target specific recognition during hybridisation tests. In particular, radioactive measurements show a 10-fold enhancement of the oligonucleotide surface density on the porous silicon substrate compared to the flat thermal silica.

Crystallization↗

Synthesis of functional microcapsules containing suspensions responsive to electric fields.

A sort of functional microcapsules, which contain a suspension responsive to electric fields, is prepared by in situ polymerization of urea and formaldehyde. The suspension is made up of pigment phthalocyanine green (PPG) and tetrachloroethylene. In order to solve the particles' separation from the suspension during the microencapsulation and to obtain microcapsules applying to electronic ink display, the dispersibility of the particles, the contact angles between the particles and the tetrachloroethylene, and the influences of different emulsifiers on the microencapsulation are investigated. It is found that the dispersion extent and lipophilicity of the PPG particles are improved due to their surface modification with octadecylamine. The contact angles between the modified PPG particles and the tetrachloroethylene increase, and the PPG particles modified with 2 wt% octadecylamine have the best affinity for tetrachloroethylene. The interfacial tension between C(2)Cl(4) and H(2)O with urea-formaldehyde prepolymer descends from 43 to 35 mN/m, which indicates that the polymer has certain surface activity. However, water-soluble emulsifiers have an important influence during the microencapsulation because they can absorb on the surfaces of internal phase and prevent the resin of urea-formaldehyde from depositing there. From the SEM images of shell surface and cross section, the microcapsules have relatively smooth surfaces and the average thickness is about 4.5 mum. When the microcapsules are prepared with agitation rates of 1000 and 600 rpm, the mean diameters of the obtained microcapsules are 11 and 155 mum, respectively. The particles in the capsules move toward positive electrode with a responsive time of several hundred milliseconds while providing an electric field.

Journal Article↗

Surface-immobilized dextran limits cell adhesion and spreading.

Dextran has recently been investigated as an alternative to polyethylene glycol (PEG) for low protein-binding, cell-resistant coatings on biomaterial surfaces. Although anti-fouling properties of surface-grafted dextran and PEG are quite similar, the multivalent properties of dextran are advantageous when high-density surface immobilization of biologically active molecules to low protein-binding surface coatings is desired. The preferred methods of dextran immobilization for biomaterial applications should be simple with minimal toxicity. In this report, a method is described for covalent immobilization of dextran to material surfaces which involves low residual toxicity reagents in mild aqueous reaction conditions. 70 kDa MW dextran was immobilized on glass and polyethylene terephthalate (PET) surfaces. 3T3 fibroblast cell adhesion was compared on untreated, aminated, and dextran-coated materials. Dextran coatings effectively limited cell adhesion and spreading on glass and PET surfaces in the presence of serum-borne cell adhesion proteins. With dextran-based surface coatings, it will be possible to develop well-defined surface modifications that promote specific cell interactions and perhaps better performance in long-term biomaterial implants.

3T3 Cells↗

Evidence for rigid binding of rhodamine 6G to silica surfaces in aqueous solution based on fluorescence anisotropy decay analysis.

Strong ionic binding of the cationic probe rhodamine 6G (R6G) to the anionic surface of silica particles in water provides a convenient labeling procedure to study both particle growth kinetics and surface modification by time-resolved fluorescence anisotropy (TRFA). The decays for R6G dispersed in diluted Ludox silica sols usually fit to a sum of picosecond and nanosecond decay components, along with a significant residual anisotropy component. The origin of the nanosecond decay component (phi2) is not fully understood, and has been ascribed to wobbling of the probe on the silica surface, the presence of a subpopulation of small nanoparticles in the Ludox sol, or rapid exchange between free and bound R6G. To elucidate the physical meaning of phi2, measurements were performed in various silica-based colloidal systems using different concentrations of silica. We found that the fraction of phi2 was generally higher in Ludox than in aqueous sodium silicate and decreased with increasing silica concentration; phi2 vanished upon gelation of sodium silicate at pH 7 leading to a total loss of R6G depolarization (r(t) = const). These results rule out the presence of local R6G wobbling when bound ionically to colloidal silica and support the rigid sphere model to describe the TRFA decays for R6G-Ludox. This conclusion is entirely supported by steady-state anisotropy data and structural considerations for the R6G molecule and the silica surface.

Journal Article↗

Enhanced bone marrow stromal cell adhesion and growth on segmented poly(ether ester)s based on poly(ethylene oxide) and poly(butylene terephthalate).

In previous studies in rats and goats, hydrophilic compositions of the PEOT/PBT block copolymer family have shown in vivo calcification and bone bonding. These copolymers are therefore interesting candidates as scaffolding materials in bone tissue engineering applications. Model studies using goat bone marrow stromal cells, however, showed that it was not possible to culture bone marrow stromal cells in vitro on these hydrophilic copolymers. In this paper two ways of surface modifying these materials to improve in vitro bone marrow stromal cell attachment and growth are discussed. Two different approaches are described: (1) blending of hydroxyapatite (HA) followed by CO(2) gas plasma etching; (2) surface modification using CO(2) gas plasma treatments. It was observed that not only HA but also the CO(2) plasma treatment by itself has a positive effect on bone marrow stromal cell attachment and growth. Gas plasma treatment appeared to be the most successful approach, resulting in a large increase in the amount of bone marrow stromal cells present on the surface (determined by a DNA assay). The amount of DNA present on the plasma-treated copolymer 1000/70/30 PEOT/PBT, based on poly(ethylene oxide, M(w) = 1000, 70 m% soft segment), was comparable to the amount present on PDLLA and significantly higher than the amount present on PCL after 7 days of cell culturing. The fact that after gas plasma treatment bone marrow stromal cells do attach to PEOT/PBT copolymers, enables in vitro bone marrow stromal cell culturing, making bone tissue engineering applications of these materials possible.

Animals↗

Novel surface functional properties of polymannosyl lysozyme constructed by genetic modification.

The surface functional properties of glycosylated lysozyme were investigated by using polymannosyl and oligomannosyl enzymes at the position 49 by genetic modification [Nakamura, S. et al. (1993) J. Biol. Chem. 268, in press]. The polymannosyl lysozyme exhibited excellent emulsifying properties superior to those of commercial emulsifiers in addition to heat stability, while the oligomannosyl lysozyme did not. The surface tension of the polymannosyl lysozyme was greatly decreased correspondingly to the enhanced emulsifying properties, although that of oligomannosyl protein was not. The emulsifying activity and the emulsion stability of the polymannosyl lysozyme were stable in acidic pH or high salt conditions; in addition, they were greatly enhanced also by preheating the polymannosyl lysozyme. Thus novel surface functional properties of polymannosyl lysozyme in addition to heat stability suggest the direction of the design of new functional proteins by genetic modification.

Animals↗

Fabrication of alternating polycation and albumin multilayer coating onto stainless steel by electrostatic layer-by-layer adsorption.

Multilayer films consisting of polyethylenimine (PEI) and albumin were successfully prepared on biomedical 316L stainless steel surface via electrostatic self-assembly of the PEI and albumin. The process of electrostatic self-assembly of PEI/albumin was monitored by125I radiolabeling, electrochemical impedance spectroscopy (EIS) and atomic force microscopy (AFM). The EIS data revealed that the multilayer coating was stable in Tris-HCl (pH 7.35) buffer solution for 21 days. 125I radiolabeling experiments indicated that less than 10% albumin was eluted by PBS in 45 days. Static platelet adhesion experiments indicated that the PEI/albumin deposited on stainless steel could resist platelet adhesion effectively. Such an easy processing and shape-independent method may have good potential for surface modification of cardiovascular devices.

Adsorption↗

Protein patterning by maskless photolithography on hydrophilic polymer-grafted surface.

With the help of a microfabrication process and surface modification technology, a method of fabricating protein patterned chips was developed which can be utilized as a powerful tool for performing bioassays in a high-throughput manner. A digital micromirror array (MMA) system was used as a virtual photomask, so that a maskless photolithography process was able to be used to build patterned biomolecules on a chip by selective illumination onto the chip surface. We utilized the nitroveratryloxycarbonyl (NVOC) group as a photolabile protecting group for protein patterning. The NVOC-protected surface was selectively irradiated by a UV illuminator using an MMA. After removing the NVOC group, biotin was coupled to the NVOC-cleaved site, onto which a buffered streptavidin solution was eluted. At this point, we could obtain a streptavidin-patterned surface and observe the effect of the polymer-grafted surface in reducing nonspecific binding.

Adsorption↗

Imaging of peptide adsorption to microfluidic channels in a plastic compact disc using a positron emitting radionuclide.

A method for studying peptide-surface interactions within microfluidic channels by radionuclide imaging is described. With the high surface area-to-volume ratio of channels in miniaturised devices, combined with low amounts of analyte, non-specific peptide adsorption is a critical issue. The objective of the study was therefore to develop a method capable of direct detection of adsorbed peptide within microfluidic channels. A micro-device consisting of channels moulded in a plastic compact disc was chosen for the study, together with two selected peptides of different lengths and isoelectric point (pI) values. A bifunctional chelator, DOTA, was attached to the peptide by conjugation and labelled with the short-lived positron emitting radionuclide 68Ga. Quantitative images of radiotracer distribution within the microfluidic channels were obtained using a PhosphorImager system. The power of the method was demonstrated by the ability to clearly measure changes in adsorption when varying a number of parameters that typically affect peptide adsorption. These included surface modifications, analyte concentration, pH, and ionic strength. Additionally, two quantification methods were developed and compared. Radionuclide imaging also permitted visualisation of adsorption and release processes in microchannel chromatographic columns. The results suggest that radionuclide imaging is a suitable tool not only for the study of peptide adsorption to the microchannels presented in this study but also as a versatile tool to measure peptide-surface interactions in a wide variety of miniaturised structures and devices.

Adsorption↗

Synergistic effect of silanol group and calcium ion in chitosan membrane on apatite forming ability in simulated body fluid.

A chitosan membrane modified with silanol groups and calcium ions on its surface and in its structure, respectively, was newly developed and evaluated for the potential application as a bioactive-guided bone-regeneration membrane. The chitosan membrane, which contained calcium nitrate tetrahydrate, was prepared and further subjected to surface modification with 3-isocyanatopropyl triethoxysilane (IPTS) following hydrolysis with HCl solution. As control, chitosan membranes which contained only calcium nitrate tetrahydrate and modified with only silanol groups were prepared, respectively. Three membranes were exposed to simulated body fluid (SBF) for a period ranging from 3 h to 7 days. The SBF exposure led to the deposition of a layer of apatite crystals on the surface of the chitosan membrane modified with silanol groups and calcium ions, while those modified with only calcium ions or silanol groups did not show the apatite-forming ability. It implies that the silanol groups and calcium ion acted together in a synergistic fashion in the formation of apatite crystals; the silanol groups and calcium ions acted as the nucleation sites and accelerator for the formation of apatite crystals, respectively. Therefore, this new chitosan membrane is likely to have a potential for the application as a bioactive guided bone regeneration membrane because of its apatite-forming ability in the SBF.

Apatites↗

In vitro assessment of bioactive coatings for neural implant applications.

Recent efforts in our laboratory have focused on developing methods for immobilizing bioactive peptides to low cell-adhesive dextran monolayer coatings and promoting biospecific cell adhesion for biomaterial implant applications. In the current study, this dextran-based bioactive coating technology was developed for silicon, polyimide, and gold, the base materials utilized to fabricate our prototype neural implants. Chemical composition of all modified surfaces was verified by X-ray photoelectron spectroscopy (XPS). We observed that surface-immobilized dextran supported very little cell adhesion in vitro (24-h incubation with serum-supplemented medium) on all base materials. Inactive nonadhesion-promoting Gly-Arg-Ala-Asp-Ser-Pro peptides immobilized on dextran-coated materials promoted adhesion and spreading at low levels not significantly different from dextran-coated substrates. Arg-Gly-Asp (RGD) peptide-grafted surfaces were observed to promote substantial fibroblast and glial cell adhesion with minimal PC12 (neuronal cell) adhesion. In contrast, dextran-coated materials with surface-grafted laminin-based, neurite-promoting Ile-Lys-Val-Ala-Val (IKVAV) peptide promoted substantial neuron cell adhesion and minimal fibroblast and glial cell adhesion. It was concluded that neuron-selective substrates are feasible using dextran-based surface chemistry strategies. The chemical surface modifications could be utilized to establish a stable neural tissue-implant interface for long-term performance of neural prosthetic devices.

Amino Acid Sequence↗

Effect of three adhesive primers for a noble metal on the shear bond strengths of three resin cements.

The purpose of this study was to evaluate the durability and shear bond strengths of the different combinations of three adhesive primers and three resin cements to a silver-palladium-copper-gold (Ag-Pd-Cu-Au) alloy. The adhesive primers Alloy Primer (AP), Metal PrimerII (MPII) and Metaltite (MT), and the resin cements BistiteII (BRII), Panavia Fluoro Cement (PFC) and Super-Bond C&B (SB) were used. Two sizes of casting alloy disks were either non-primed or primed and cemented with each of the three resin cements. The specimens were stored in a 37 degrees C water bath for 24 h and then immersed alternately in 4 and 60 degrees C water baths for 1 min each for up to 100,000 thermal cycles. Shear mode testing at a crosshead speed of 0.5 mm/min was then performed. The application of MPII or MT was effective for improving the shear bond strength between each of the three resin cements and the Ag-Pd-Cu-Au alloy compared with non-primed specimens. However, when primed with MPII or MT and cemented with SB, the bond strength at 100,000 thermal cycles was significantly lower than that at thermal cycle 0. When primed with AP, the specimens cemented with BRII or PFC showed lower bond strength than non-primed specimens and failed at the metal-resin cement interface at 100,000 thermal cycles. On the other hand, AP was effective in enhancing the shear bond strength of SB to the Ag-Pd-Cu-Au alloy. The five combined uses of an adhesive metal primer and resin cement (combinations of MPII or MT and BRII or PFC and AP and SB) are applicable to the cementation of prosthodontic restorations without complicated surface modification of the noble alloy.

Adhesives↗