PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Importance of the superficial tissue layer for the indentation stiffness of articular cartilage.

Indentation testing is a widely used technique for nondestructive mechanical analysis of articular cartilage. Although cartilage shows an inhomogeneous, layered structure with anisotropic mechanical properties, most theoretical indentation models assume material homogeneity and isotropy. In the present study, quantitative polarized light microscopy (PLM) measurements from canine cartilage were utilized to characterize thickness and structure of the superficial, collageneous tissue layer as well as to reveal its relation to experimental indentation measurements. In addition to experimental analyses, a layered, transversely isotropic finite element (FE) model was developed and the effect of superficial (tangential) tissue layer with high elastic modulus in the direction parallel to articular surface on the indentation response was studied. The experimental indentation stiffness was positively correlated with the relative thickness of the superficial cartilage layer. Also the optical retardation, which reflects the degree of parallel organization of collagen fibrils as well as collagen content, was related to indentation stiffness. FE results indicated effective stiffening of articular cartilage under indentation due to high transverse modulus of the superficial layer. The present results suggest that indentation testing is an efficient technique for the characterization of the superficial degeneration of articular cartilage.

Animals↗

[Study on the biomechanical behavior of human intestine].

To investigate the biomechanical behavior of human intestines. The tensile test human intestine was performed with the electronic tension machine in this paper. The results indicate that the exponential relationship for the stress-strain of the human intestine was obtained, and the exponential coefficient a of each segment of the intestine is almost the same although the constant C is different. It also shows that the relative rate of stretch length of each segment intestines is different in longitudinal and circumferential directions. And the incremental elastic modulus of colon is less than those of small intestine. It is considered that the colon can be more easily deformed. The experimental results provide the theoretic basis for research on intestinal endoscopic microrobot.

Biomechanical Phenomena↗

Gender differences in biomechanical properties of intramural coronary resistance arteries of rats, an in vitro microarteriographic study.

The prevalence of ischemic heart disease is lower in premenopausal females than in males of corresponding age. This should be related to gender differences in coronary functions. We tested whether biomechanical differences exist between intramural coronary resistance arteries of male and female rats. Intramural branches of the left anterior descending coronary artery (uniformly approximately 200microm in diameter) were isolated, cannulated and studied by microarteriography. Intraluminal pressure was increased from 2 to 90mmHg in steps and steady-state diameters were measured. Measurements were repeated in the presence of vasoconstrictor U46619 (10(-6)M) and the endothelial coronary vasodilator bradykinin (BK) (10(-6)M). Finally, passive diameters were recorded in calcium-free saline. A similar inner radius and a higher wall thickness (41.5+/-2.9microm vs. 31.4+/-2.7microm at 50mmHg in the passive condition, p<0.05) resulted in lower tangential wall stresses in male rats (18.9+/-1.9kPa vs. 24.9+/-2.5kPa at 50mmHg, p<0.05). Isobaric elastic modulus of vessels from male animals was significantly smaller at higher pressures. Vasoconstrictor response was significantly stronger in male than in female animals. Endothelial relaxations induced by BK were not different. This is the first demonstration that biomechanical characteristics of intramural coronary resistance arteries of a mammalian species are different in the male and female sexes. Higher wall thickness and higher vascular contractility in males are associated with similar endothelial function and larger high-pressure elasticity compared to females. These gender differences in biomechanics of coronary resistance arteries of rats may contribute to our better understanding the characteristic physiological and pathological differences in humans.

Animals↗

A pinch elastometer for soft tissue.

A prototype compression elastometer suited to the characterisation of soft tissue is analysed and tested by application to various elastomers. The test material is pinched between two rigid cylinders and the compression force and displacement interpreted to yield a measure of "effective" stiffness or to calibrate a simple non-linear-elastic material model (Neo-Hookean). This deformation suits the testing of bulk soft tissue since it effectively isolates the test material from boundary conditions such as other soft tissue, ligaments and bones. These can be highly variable in the body and can affect results greatly when employing other types of tests to determine the elastic nature of tissue. A simple linear-material analysis, based on established solutions to two-dimensional problems, is extended to take into account various geometrical complexities. This analysis permits immediate inversion of the readings from the device to yield the elastic properties of the material, without the need for complex numerical analysis. Finite element analysis is also employed to determine the range of reliable application of the linear-elastic model. In particular, this analysis permits the extension of the linear-elastic analysis to include simple forms of non-linear-material behaviour. The method is demonstrated using three elastomers having significantly different material properties. A viable range of application of the device is identified in which it yields results with reasonable precision and accuracy. The prototype device was able to measure the effective elastic modulus of the test materials with a maximum error of 13% for three material types (N=25). Repeatability error was less than 7% in all cases. Further refinement of the device and measuring system will reduce this uncertainty.

Biomechanical Phenomena↗

Rheology of concentrated suspensions of deformable elastic particles such as human erythrocytes.

New models for the viscosity of concentrated suspensions of deformable elastic particles are developed using the differential effective medium approach (DEMA). The models are capable of describing the rheological behavior of un-aggregated suspensions of human red blood cells (RBCs). With the increase in shear rate, a shear-thinning behavior is predicted similar to that observed in the case of un-aggregated suspensions of RBCs. A decrease in relative viscosity and an enhancement of shear-thinning behavior is predicted when either the particle rigidity (elastic modulus) is decreased or the continuous medium viscosity is increased. These predictions are similar to those observed in suspensions of human RBCs. The proposed models are evaluated using experimental data on normal and hardened human RBC suspensions in protein-free saline.

Blood Flow Velocity↗

Composite hydrogels for implants.

Hydrophilic composite structures are designed to mimic the transport and mechanical properties of natural soft tissue such as tendons, ligaments and intervertebral discs. Mechanical and viscoelastic behaviour of a soft composite material based on a hydrogel matrix reinforced with bundles of polyethylene therephthalate (PET) fibres is analysed. The typical J-shaped stress-strain behaviour, displayed by natural tendons and ligaments, is reproduced. The mechanical characteristics, such as the extent of the 'toe-in region' and the elastic modulus in the linear region, can be controlled by varying the winding angle of the fibres and the matrix composition. Dynamic mechanical analysis showed the dual behaviour of the composite systems due to the progressive contribution of the PET fibres. Different poly(2-hydroxyethylmethacrylate)/polycaprolactone (PHEMA/PCL) semi-interpenetrating polymer networks (IPNs) hydrogel composite systems reinforced with PET fibres have been investigated for potential use as intervertebral disc prostheses. Compression properties have been evaluated by static and dynamic tests. Uniaxial compression tests on the swollen samples showed an increase of the modulus and maximum stress with increasing content of PCL and PET fibres. Creep behaviour is also dependent on the hydrogel composition. The composite PHEMA/PCL hydrogels showed compression properties similar to those expressed by canine intervertebral discs in different spinal locations.

Animals↗

Effects of incremental curing on contraction stresses associated with various resin composite buildups.

OBJECTIVE: The purpose of this study was to photoelastically evaluate contraction stresses associated with various resin composite build-up procedures, including incremental curing and the use of flowable composite for pulpless molars. METHOD AND MATERIALS: Life-sized photoelastic models of an endodontically treated molar were fabricated. The cavity represented a conservative access preparation and included four lateral walls. The following materials were used for buildup: dual-cured hybrid composite (Cleafil DC Core [DC], BIS-CORE [BC]); light-cured flowable composite (AELITEFLO LV [ALV]); and chemical-cured flowable composite (CORE-FLO [CF]). The photoelastic models were built up with the following techniques: bulk-cured (BDd [dual-cured DC], BDc [chemically-cured DC], BBd [dual-cured BC], and BC [CF]); and incremental-cured (1 mm gingivally + 3.5 mm occlusally; IAB [ALV + BC], ICB [CF + BC], and IBB [BC + BC]). Isochromatic fringes developed in the models were recorded photographically in the field of a circular polariscope, and maximum fringe order was determined. Five specimens were tested for each condition. RESULTS: Stress intensity of the build-up methods fell into two categories: high (BDd, BBd, BC, and IAB) and low (BDc, ICB, and IBB). The difference between high and low groups was statistically significant, except between BC and ICB. The maximum fringe order was developed around the point angles at the cavity floor for all the conditions tested. CONCLUSIONS: Type and setting mechanism of resin composite build-up technique had considerable influence on contraction stress. Incremental buildup using composites with low elastic modulus did not reduce contraction stress intensity compared with bulk-cured techniques.

Barium Compounds↗

Tissue-water relations of two co-occurring evergreen Mediterranean species in response to seasonal and experimental drought conditions.

Tissue-water relations were used to characterize the responses of two Mediterranean co-occurring woody species (Quercus ilex L. and Phillyrea latifolia L.) to seasonal and experimental drought conditions. Soil water availability was reduced approximately 15% by partially excluding rain throughfall and lateral flow (water runoff). Seasonal and experimental drought elicited physiological and morphological adaptations other than osmotic adjustment: both species showed large increases in cell-wall elasticity and decreased saturated-to-dry-mass ratio. Increased elasticity (lower elastic modulus) resulted in concurrent decreases in relative water content at turgor loss. In addition, P. latifolia showed significant increases in apoplastic water fraction. Decreased saturated-to-dry-mass ratio and increased apoplastic water fraction were accompanied by an increased range of turgor maintenance, which indicates that leaf sclerophyllous traits might be advantageous in drier scenarios. In contrast, the degree of sclerophylly (as assessed by the leaf mass-to-area ratio) was not related to tissue elasticity. An approximately 15% reduction in soil water availability resulted in significant reductions in diameter growth when compared to control plants in both species. Moreover, although P. latifolia underwent larger changes in tissue water-related traits than Q. ilex in response to decreasing water availability, growth was more sensitive to water stress in P. latifolia than in Q. ilex. Differences in diameter growth between species might be partially linked to the effects of cell-wall elasticity and turgor pressure on growth, since Q. ilex showed higher tissue elasticity and higher intrinsic tolerance to water deficit (as indicated by lower relative water content at turgor loss) than P. latifolia.

Adaptation, Physiological↗

Nonlinear viscoelasticity and the thrombelastograph: 1. Studies on bovine plasma clots.

To study the possible role of nonlinear viscoelastic effects in the thrombelastograph (TEG), clotting of bovine plasma was studied by both thrombelastography and with a controlled strain rheometer. Clot rheology is dominated by elastic effects at frequencies of interest. There is a well-defined regime of linear elasticity for strains less than around 2%, while at larger strains the clots show significant strain hardening. Oscillatory shear applied during clotting has little effect on the resulting clot provided that the strain is less than 2%, but leads to substantial weakening of clots formed at larger strains. The TEG operates within the regime of nonlinear elasticity, significantly obscuring the interpretation of TEG amplitude in terms of an elastic modulus. Comparing the results of standard TEG experiments with those conducted with a modified TEG, having no oscillation during clotting, shows that deformation during standard thrombelastography leads to weaker clots than are produced under quiescent conditions.

Animals↗

Microbial surfaces investigated using atomic force microscopy.

This paper is dedicated to atomic force microscopy (AFM) as a progressive tool for imaging bacterial surfaces and probing their properties. The description of the technique is complemented by the explanation of the method's artifacts typical, in particular, for the imaging of bacterial cells. Sample preparation techniques are summarized in a separate section. Special attention is paid to the differences in imaging of gram-positive and gram-negative bacteria. Probing of mechanical properties, including elastic modulus, fragility, and adhesion of the cell walls is emphasized. The advantages of AFM in the studies of real-time cellular dynamical processes are illustrated by the experiment with the germination of spores.

Bacteria↗

Finite element analysis studies of a metal-ceramic crown on a first premolar tooth.

PURPOSE: This study examined the stresses developed during loading in a first premolar metal-ceramic crown made of different metal cores, and used them to anticipate the locations and form of the most likely failure modes. The maximum principal stresses in the porcelain are indicators of fracture, and the von Mises stresses in the metal core are indicators of the location of yielding. MATERIALS AND METHODS: Two-dimensional axisymmetric models with different core metals were analyzed using finite element analyses. An axial load of 600 N was applied vertically downward, over a circular area around the crown's fissure. RESULTS: The peak maximum principal tensile stress in the porcelain existed on the surface of the crown, partially outside the cusp, with the greatest peak in the gold-porcelain system (15.8 MPa). An inverse relationship between the peak maximum principal tensile stress of each system and the elastic modulus of each core material was found. According to evaluation of the critical flaw size for each system, even a crack completely through the thickness of the porcelain was not critical. The maximum von Mises stress existed in the metal coping, on the radial edge at the axial/occlusal line angle, with the highest maximum in the nickel-chromium system (143.9 MPa). There existed a proportional relationship between the maximum von Mises stress in each metal and their respective elastic moduli. All maximums were well below the yield strength of the metal alloys used. CONCLUSION: A greater understanding of the influence of an axial load on the resulting stresses has been achieved, showing that the phenomena of fracture and yielding are unlikely for the crown experiencing this axial load.

Bicuspid↗

Mechanical characterization of resin cements used for luting fiber posts by nanoindentation.

OBJECTIVES: To evaluate the mechanical behavior of resin cements used for luting fiber post. The influence of the curing mode is analysed. METHODS: Nanoindentation techniques have been applied to determine hardness and Young's modulus of disc-shaped specimens of three types of cements: chemical- , photo- and dual-cured, provided by Ivoclar-Vivadent. Results obtained have been compared with measurements performed inside the post-cement-dentin system. Mechanical properties are evaluated together with scanning electron micrographs showing the post-cement and dentin-cement interfaces. RESULTS AND SIGNIFICANCE: Differences have been detected between mechanical measurements performed inside the post-cement-dentin system and those carried out in laboratory disc-shaped specimens. The close presence of post and dentin boundaries has a lot of influence on the cement behavior. The nanoindentation measurements indicate that the photo-cured cement exhibits a high hardness and stiffness, but with a more marked tendency to brittle failure. The chemically cured cement is the material with higher ability to bear deformation without damage, although its hardness and elastic modulus are significantly lower. Dual-cured cements present the best combination of properties.

Dental Materials↗

Thermal behavior and elastic properties of phospholipid bilayers under the effect of a synthetic flavonoid derivative, LEW-10.

We have investigated the effect on phospholipidic bilayers of LEW-10, a synthetic flavonoid, derivative of diosmin. Two optical techniques, Quasi-elastic Light Scattering (QLS) and Fourier Transform Infrared Spectroscopy (FT-IR) were used. The results show that in the presence of LEW-10, the phase transition of the bilayers is lowered and that the elastic modulus is decreased. The FT-IR results indicate interactions in the aqueous interface regions of the bilayers. We also discuss LEW-10 comparatively with another derivative, LEW-7/S1, whose effect has been previously studied.

Carbohydrate Sequence↗

A composite coating by electrolysis-induced collagen self-assembly and calcium phosphate mineralization.

A composite coating that is composed of collagen protein and calcium phosphate minerals is considered to be bioactive and may enhance bone growth and fixation of metallic orthopedic implants. In this study, we have successfully developed a uniform collagen fibril/octacalcium phosphate composite coating on silicon substrate by electrolytic deposition (ELD). The coating deposition was done through applying a constant potential to the cathode in a three-electrode electrochemistry cell that contain a mild acidic (pH 4.8-5.3) aqueous solution of collagen molecules, calcium and phosphate ions. The coating process involved self-assembly of collagen fibrils and the deposition of calcium phosphate minerals as a result of cathode reaction and local pH increase. The two steps could be synchronized to form a bone-like composite at nanometer scale through proper adjustment of the solution and deposition parameters. Coating morphology, crystal structure and compositions were analyzed by optical and fluorescence microscopy, scanning and transmission electron microscopy, energy dispersive X-ray analysis, inductively coupled argon plasma optical emission spectrophotometry, and Fourier-transformed infrared spectroscopy. Under typical deposition conditions, the cathode (Si) surface formed a thin (100 nm) layer of calcium phosphate coating, on top of which a thick (approximately 100 microm) composite layer formed. The porous composite layer consists of a collagen fibril network on which clusters of octacalcium phosphate crystals nucleate and grow. By combining photolithography and ELD, we were also able to pattern the composite coating into regular arrays of squares. Preliminary results by nanoindentation tests showed that properly prepared composite coating may have higher elastic modulus and scratch resistance than monolithic porous calcium phosphate coating. The results not only provide a novel bioactive coating for biomedical implants, but also establish a new experimental protocol for studying biomineralization mechanisms of collagen based biological tissues.

Bone Substitutes↗

Evolution of flexural rigidity according to the cross-sectional dimension of a superelastic nickel titanium orthodontic wire.

The choice of the most suitable orthodontic wire for each stage of treatment requires estimation of the forces generated. In theory, the selection of wire sequences should initially utilize a lower flexural rigidity; thus clinicians use smaller round cross-sectional dimension wires to generate lighter forces during the preliminary alignment stage. This assessment is true for conventional alloys, but not necessarily for superelastic nickel titanium (NiTi). In this case, the flexural rigidity dependence on cross-sectional dimension differs from the linear elasticity prediction because of the martensitic transformation process. It decreases with increasing deflection and this phenomenon is accentuated in the unloading process. This behaviour should lead us to consider differently the biomechanical approach to orthodontic treatment. The present study compared bending in 10 archwires made from NiTi orthodontics alloy of two cross-sectional dimensions. The results were based on microstructural and mechanical investigations. With conventional alloys, the flexural rigidity was constant for each wire and increased largely with the cross-sectional dimension for the same strain. With NiTi alloys, the flexural rigidity is not constant and the influence of size was not as important as it should be. This result can be explained by the non-constant elastic modulus during the martensite transformation process. Thus, in some cases, treatment can begin with full-size (rectangular) wires that nearly fill the bracket slot with a force application deemed to be physiologically desirable for tooth movement and compatible with patient comfort.

Dental Alloys↗

Strain rate effect on the failure properties of tendons.

The purpose of this study is to evaluate the effect of strain rate on the failure properties of tendons. Seventy-five chicken flexor digitorum profundus (FDP) tendons were tensile tested at 15 strain rates, ranging from 0.05 to 150 per cent/s. Results showed that strain rate had little effect on the shape of the stress-strain curve. No significant change was observed in the toe region, while the slope of the linear region increased with the increase in strain rate. Generally, the ultimate tensile strength (UTS) and elastic modulus increased significantly as strain rate increased (p < 0.01), while no significant change in strain at UTS (p > 0.01) was observed. It was found the change in failure properties of tendons was not significant, with small change in strain rate.

Animals↗

Viscoelastic properties of the normal human bladder.

Continuous and stepwise cystometry were performed through suprapubic catheters in 12 healthy young subjects in order to assess passive viscoelastic variables of the normal human bladder during the collection phase. Elastic contants increased non-linearly with bladder distension. Relative elastic modulus and relaxation time of the bladder wall increased or tended to increase with bladder distension and infusion rate. There was considerable interindividual variation in all variables suggesting that discrimination between normal and abnormal bladder wall viscoelasticity may be difficult in routine clinical practice.

Adult↗

EGF-stimulated lamellipod extension in adenocarcinoma cells.

The extension of lamellipodia has been triggered by the application of epidermal growth factor (EGF). We have used an atomic force microscope (AFM) to investigate this lamellipodial extension. During extension we could detect an increase in height from about 500 nm for the stable lamellipodium to typical values of 600-800 nm for the extending lamellipodium. The AFM was also used to determine the mechanical properties of the lamellipodium where we found a decrease of the elastic modulus by a factor of 1.4 at the same location within the same cell. Both findings are consistent with the cortical expansion hypothesis, suggesting that severing of actin filaments, leading to a swelling of the cytoskeleton, generates the protrusive force during lamellipodial extension.

Adenocarcinoma↗