Pull-out strength of the suprapedicle claw construct: a biomechanical study.

The pull-out of the superior screw is a well recognized problem in anterior instrumentation of the spine for scoliosis. A biomechanical pull-out study of anterior vertebral body screw in cadaveric thoracic spine was therefore designed to investigate and compare the pull-out strength of three different anterior vertebral body fixations using the AO Universal Spine System: simple bicortical screw, bicortical screw with an opposite washer (sometimes called pull-out resistant nut), and a new construct made of a bicortical screw with the addition of a suprapedicular hook on the same vertebra (or claw construct). The T4 to T9 vertebral bodies from six human cadavers (total of 36 specimens) were instrumented with three different instrumentation constructs after measuring the bone mineral density of each individual vertebra. After stabilization of the vertebral bodies, the screws were extracted employing a material testing system using axial pull-out. The maximum axial forces were recorded at the time of the construct failure. The mean ultimate fixation strength (UFS) values after being adjusted for bone mineral density and vertebral body diameter were 631, 711, and 1244 N for the three different constructs, respectively (screw alone, screw with an opposite washer, and screw with a suprapedicle claw). The difference in UFS was not significant for the first two constructs tested (screw alone and screw with an opposite washer). However, the difference in ultimate fixation strength between the claw and the other constructs was highly significant (P<0.0001). Specimens with low BMD did not benefit as much from claw construct as the ones did with a normal BMD. The failure mode of each construct was described, but was in neither case judged dangerous for the spinal cord. This study shows that the suprapedicle claw construct improves the pull-out strength of an anterior vertebral body screw by 80%, and changes the mode of failure so as not to rely only on the screw characteristics or solely on the vertebral body. By adding a suprapedicle hook in a claw configuration, one may prevent superior screw pull-out in anterior spine surgery for scoliosis.

Biomechanical Phenomena↗

A biomechanical analysis of two biceps tenodesis fixation techniques.

PURPOSE: To assess and compare the biomechanical properties and load-to-failure of 2 biceps tenodesis fixation techniques, interference screw fixation and double suture anchor fixation. TYPE OF STUDY: Biomechanical study. METHODS: Eleven fresh-frozen human cadaveric specimens were used in this study. A biceps tenodesis was performed using 1 of 2 techniques, interference screw fixation or double suture anchor fixation. A 7-mm interference screw was used in 5 cadaveric trials. A double suture anchor technique was performed in 6 cadaveric specimens. The tenodesis construct in each specimen was loaded to failure using a Servohydraulic materials test system (MTS Model 858; Bionix, MTS Corp, Minneapolis, MN). Each specimen was loaded at 5 mm/second with a preload of 5 N with the vector of pull distally in line with the long axis of the humerus. Each specimen was then loaded until failure of the repair occurred. Statistical analysis of the interference screw group compared with the suture anchor group was performed using a Student t test. RESULTS: The mode of failure of the interference screw group was variable, but the suture anchor group consistently failed at the anchor or anchor eyelet. The average pullout strength of the suture anchor group was 135.5 +/- 37.8 N whereas the failure load in the interference group was 233.5 +/- 55.5 N. The interference group had a significantly greater resistance to pullout than the suture anchor group (P = .007). CONCLUSIONS: Based on these results, a biceps tenodesis using an interference screw will provide greater fixation strength than a biceps tenodesis performed with a double suture anchor technique. CLINICAL RELEVANCE: The surgeon treating biceps tenodesis may wish to choose a fixation technique with higher initial strength (interference screw instead of double suture anchor) to lessen the chance of early failure, particularly if the patient begins early active elbow flexion.

Adult↗

Accuracy of a video strain measurement system.

The purpose of this study was to determine the accuracy of a video system which our laboratory has been using to measure soft tissue strain. Both static and dynamic error analyses were performed to assess the accuracy of our video system. Static error was defined as the amount of movement reported by the video system for markers that were stationary. Dynamic error was defined as the difference between the motion of the markers as reported by the video system and their actual motion. Two sets of fluorescent markers were attached to a servo-hydraulic materials test machine. One marker set was attached to the hydraulic actuator (moving markers) and the other set was attached to the base of the machine (stationary markers). Five different marker sizes, five camera distances, and seven different loading rates were studied. Results indicated that the static error was independent of marker size, and that the dynamic error was independent of the loading rate and marker size for loading rates of 50% of the camera field of view (CFV) per second or slower. For loading rates greater than 50 percent of CFV per second, the marker size did have an affect on the dynamic error. The mean static error was found to be 0.026 percent of CFV and the mean dynamic error was found to be 0.062 percent of CFV.

Computer Systems↗

Bonding of contemporary glass ionomer cements to dentin.

OBJECTIVE: The objective of this study was to investigate the microtensile bond strength (microTBS) of contemporary glass ionomer cements (GIC) to sound coronal dentin. METHODS: Three specimen teeth were prepared for each material tested: Fuji IX GP (GC), ChemFlex (Dentsply) and Ketac-Molar Aplicap (ESPE). GIC buildups were made according to the manufacturers' instructions. After being stored at 37 degrees C, 100% humidity for 24h, the teeth were vertically sectioned into 1x1mm beams for microTBS evaluation. Representative fractured beams were prepared for scanning (SEM) and transmission electron microscopic (TEM) examination. RESULTS: Results of the microTBS test were: Fuji IX GP (12.4+/-8.6MPa), ChemFlex (15.0+/-9.3MPa) and Ketac-Molar Aplicap (11.4+/-7.7MPa). One-way ANOVA and a multiple comparison test showed that ChemFlex had a statistically higher microTBS (p<0.05). SEM fractographic analysis showed that the predominant failure modes were interfacial and mixed failures. The GIC side of the fractured beams revealed dehydration cracks, a high level of porosity, and voids with an eggshell-like crust. TEM analysis of the demineralized dentin sides of the fractured beams revealed the presence of an intermediate layer along the GIC-dentin interface. This zone was present on the fractured dentin surface in the case of interfacial failure, and beneath GIC remnants in specimens that exhibited a mixed failure mode. SIGNIFICANCE: The findings suggest that the bonding of GIC to dentin is not weak and that the microTBS values probably represent the weak yield strengths of GICs under tension.

Acid Etching, Dental↗

Comparison of tensile strength of resorbable plating systems used in monocortical mandible angle osteotomy repair.

OBJECTIVE: To determine the usefulness of resorbable plating systems in load-bearing applications of the mandible and the location of critical failure. METHODS: An osteotomy was created in 24 fresh cadaveric mandibles at the angle and fixated by the Champy technique with similar resorbable craniofacial plating systems from 4 manufacturers. Each mandible was held rigid as a material test system applied a downward force anteriorly. The critical tolerance was measured and the type of failure was noted. RESULTS: Critical failure occurred at forces from 34.6 to 137.8 N. We found a statistically significant difference between the plating groups (P<.001 for all comparisons). The point of failure was almost uniformly at the plate. CONCLUSIONS: Critical failure was overwhelmingly due to rupture of the plate rather than to stripping or shearing of the screws as had been strongly expected. We found differences in plate strengths for this particular application and did not evaluate their respective long-term resorptive properties. We do not advocate that single resorbable plate fixation be the sole means of mandible angle fracture fixation, regardless of the plating system used.

Absorbable Implants↗

Improving the reinforcement of parastomal tissues with Marlex mesh: laboratory study identifying solutions to stomal aperture distortion.

PURPOSE: Parastomal hernia formation commonly complicates permanent stomas and represents a significant and frequently recurrent management problem, regardless of the method of repair. Prosthetic material reinforcement of parastomal tissues offers the best results. However, problems with unravelling of mesh fibers along cut margins leading to aperture enlargement and hernia recurrence may occur. Raised intra-abdominal pressure in the early postoperative period before incorporation of the mesh into surrounding tissues may result in hernia formation if the aperture size in the mesh increases. METHODS: Assessment of the physical properties of Marlex mesh was performed in a materials testing laboratory, using standardized tests to simulate the stresses imposed on in situ mesh. RESULTS: Holes cut in Marlex mesh were found to enlarge and distort at loads simulating intra-abdominal pressure changes. Reinforcement with a polypropylene pursestring suture was found to stabilize the periaperture mesh fibers and maintain the original area throughout tensions at least double maximal intra-abdominal pressures. Distensibility of intact sheets of mesh was found to vary by up to 100 percent, depending on the direction of the applied tension, and thus, mesh orientation in hernia repair has major implications. CONCLUSION: We propose that if mesh is used to reinforce abdominal wall tissues and is cut or fashioned to size, then the cut margins must be reinforced if the intended dimensions and functional integrity of the mesh are to be maintained.

Abdomen↗

Fracture resistance of Class II approximal slot restorations.

STATEMENT OF PROBLEM: Determination of the fracture resistance of various restorative materials in Class II approximal slot restorations has not been studied. PURPOSE: This study evaluated the effects of retention grooves and different restorative materials in Class II approximal slot restorations. To explore the possibilities for further research, the probable effects of preparation size and loading angle were investigated in a limited manner. MATERIAL AND METHODS: Ninety sound, caries-free human maxillary premolars were divided into 9 groups. The cavities were prepared either by hand or in a computer-controlled CNC machine with or without retention grooves. Four were restored with adhesive amalgam, another 4 with composite, and a single group with Compomer resin. The gingival floor depth was 1.5 mm. The specimens were loaded at an angle of 13. 5 degrees to their longitudinal axes by using a computer-controlled material testing machine until failure occurred. For one specific preparation of adhesive amalgam, loading was applied at 0 and 30 degrees to determine the probable effects of the loading angle. For a specific composite, resin application, the effects of the change in gingival floor depth were analyzed by assigning the depth to 2.0 mm. RESULTS: Composite and Compomer resin and composite exhibited better performance than amalgam. The existence of the retention grooves proved to be effective for adhesive amalgam restorations but did not have any advantageous effect in composite and Compomer restoration. CONCLUSION: For improved fracture resistance in small approximal restorations, the use of composite was the appropriate choice. Compomer also gave satisfactory results. Use of amalgam restoration should be accompanied with retention grooves and an adhesive system to improve its performance.

Bicuspid↗

Biomechanical evaluation of fixation of posterior acetabular wall fractures.

Reproducible fractures of the posterior wall of the acetabulum were created in 10 paired hemipelves from fresh human cadavers. Under anterior-to-posterior loading by a Materials Testing System machine, the load to failure of fixation of the acetabular fractures treated with steel pelvic reconstruction plates and steel screws was significantly higher than that of fixation with titanium ribbons and titanium screws. Forces as little as 725 newtons applied directly to the fragment caused fixation failure; even the most secure form of fixation failed when a relatively small force of 2,123 newtons was applied. These results emphasize the importance of appropriate postoperative measures, such as limitation of hip flexion and restricted weightbearing, to minimize the force directed against the posterior wall until the fracture has healed. Secure fixation of fractures of the posterior wall of the acetabulum is critical, since loss of fixation results in instability and joint incongruity, which limit the options for reconstruction.

Acetabulum↗

Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures.

STUDY DESIGN: Cadaveric study on the biomechanics of osteoporotic vertebral bodies augmented and not augmented with polymethylmethacrylate cement. OBJECTIVES: To determine the strength and stiffness of osteoporotic vertebral bodies subjected to compression fractures and 1) not augmented, 2) augmented with unipedicular injection of cement, or 3) augmented with bipedicular injection of cement. SUMMARY OF BACKGROUND DATA: Percutaneous vertebroplasty is a relatively new method of managing osteoporotic compression fractures, but it lacks biomechanical confirmation. METHODS: Fresh vertebral bodies (L2-L5) were harvested from 10 osteoporotic spines (T scores range, -3.7 to -8.8) and compressed in a materials testing machine to determine intact strength and stiffness. They were then repaired using a transpedicular injection of cement (unipedicular or bipedicular), or they were unaugmented and recrushed. RESULTS: Results suggest that unipedicular and bipedicular cement injection restored vertebral body stiffness to intact values, whereas unaugmented vertebral bodies were significantly more compliant than either injected or intact vertebral bodies. Vertebral bodies injected with cement (both bipedicular and unipedicular) were significantly stronger than the intact vertebral bodies, whereas unaugmented vertebral bodies were significantly weaker. There was no significant difference in loss in vertebral body height between any of the augmentation groups. CONCLUSIONS: This study suggests that unipedicular and bipedicular injection of cement, as used during percutaneous vertebroplasty, increases acute strength and restores stiffness of vertebral bodies with compression fractures.

Absorptiometry, Photon↗

Effect of resin-modified glass ionomer cements on secondary caries.

PURPOSE: To evaluate the in vitro secondary caries inhibitory effect of two resin-modified glass ionomer cements (R-GICs). MATERIALS AND METHODS: Class V cavities were prepared at the cementoenamel junction on facial and lingual surfaces of 32 extracted upper premolars. The facial cavities were restored with a conventional glass ionomer cement (GIC) (Fuji II), while the lingual cavities were restored with either one of the R-GICs (Fuji II LC, Photac Fil, Vitremer), or a resin composite (Z-100). The margins of the restorations were subjected to a 20-day in vitro cariogenic challenge and the degree of demineralization was analyzed by microradiography. The amounts of fluoride released into distilled water from disc specimens of the materials tested were also measured for immersion time up to 161 days. RESULTS: The R-GICs and GIC's released similar cumulative amounts of fluoride over 161 days. Photac-Fil showed significantly higher amounts of fluoride release over the same period. The depth of the outer lesion and the thickness of the acid-resistant layer showed no significant difference among the R-GICs and GIC's. Moreover, the residual fluoride and calcium in the dentin adjacent to the R-GICs and GIC's were correlated with the thickness of acid-resistant layers in the dentin adjacent to the R-GICs and GIC's by electron probe microanalysis. However, the inhibitory effect of the R-GICs was not directly related to the fluoride concentrations eluted from them.

Bicuspid↗

Biomechanical comparison of bioabsorbable sutureless screw anchor versus suture anchor fixation for rotator cuff repair.

PURPOSE: Anchors that directly fix the rotator cuff to bone without using sutures may simplify the challenges associated with arthroscopic rotator cuff repair. This study compared a bioabsorbable screw fixation device to a standard suture anchor fixation method. TYPE OF STUDY: Randomized trial. METHODS: A poly-L-lactide acid (PLLA), bioabsorbable screw anchor was compared with a metallic suture anchor loaded with No. 2 braided polyester suture in 12-week-old fresh-frozen bovine shoulders. Twelve specimens were randomly assigned to the 2 repair groups (6 per group). A 1 x 2-cm defect was created at the insertion site of the infraspinatus tendon. Two anchors were implanted 1 cm apart in the anatomic insertional area of the infraspinatus tendon. After preconditioning to 10 N, each construct was cycled between 10 and 180 N for up to a maximum of 2,500 cycles at a rate of 33 mm/second using a materials testing machine. The number of cycles to 5- and 10-mm gap formation at the repair site and mode of failure were recorded. Clinically, 10-mm gap formation defines complete fixation failure. Data were evaluated using an analysis of variance with significance set at P < .05. RESULTS: Mattress suture fixation had significantly higher number of cycles to 10-mm failure compared with the PLLA device (P = .015). Failure occurred by tissue pullout in half the specimens and by device failure in the other half, without differences in failure modalities between groups. CONCLUSIONS: This anchor provides low-profile fixation of the rotator cuff and eliminates suture placement and knot tying during arthroscopic and mini-open cuff repair. However, these data suggest that this anchor may not perform adequately under cyclic loading conditions in patients during postoperative rehabilitation. CLINICAL RELEVANCE: This bioabsorbable anchor may not provide sufficient fixation for rotator cuff repair in humans.

Absorbable Implants↗

An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty.

The purpose of this study was to determine the strength and stiffness of osteoporotic vertebral bodies (VBs) subjected to compression fractures and subsequently treated with bipedicular injections of various polymethylmethacrylate cements. Ten spines were harvested from nonembalmed female cadavers (age 68.6 +/- 13.7 years) and evaluated for bone mineral density using the dual energy X-ray absorptiometry method (t-score = -2.3 +/- 2.4). The 50 VBs (L1-L5) were disarticulated, compressed in a materials testing machine to determine initial strength and stiffness, and then assigned to one of six groups. Two of these groups (n = 8, n = 9) concerned experimental cements, the results of which are not reported here. The 33 vertebral bodies in the remaining four groups were left untreated or were repaired using a transpedicular injection of one of three commercially available polymethylmethacrylate cements. These four groups were: a) no treatment (no cement, n = 8); b) Simplex P (n = 9); c) Cranioplastic (n = 8); and d) Osteobond (n = 8). The VBs were then compressed again according to the initial protocol, and posttreatment strength and stiffness were measured. Results suggested that bipedicular injection of Simplex P and Osteobond restored VB stiffness to initial values, whereas VBs injected with Cranioplastic were significantly less stiff than in their initial state. VBs injected with cement (regardless of type) were significantly stronger than they were initially.

Absorptiometry, Photon↗

Mutagenic potentials of dental cements as detected by the Salmonella/microsome test.

The potential mutagenicity of a zinc phosphate (Poscal), a polycarboxylate (Aqualox) and glass ionomer cements with (Argion) and without (Meron) silver reinforcement were characterized by employing the Ames Salmonella/microsome test. The materials were eluted in dimethyl sulphoxide or physiologic saline and the aliquots were used either immediately or after an incubation period of 24h at 37 degrees C. Mutagenic effects of the materials were tested on Salmonella typhimurium strains TA 98, TA 100, TA 102 and TA 1535 using the standard plate incorporation assay, and in the presence or absence of S9 fraction from rat liver. Poscal and Aqualox elicited mutagenic effects on S. typhimurium TA 98 and TA 1535, whereas Meron exhibited mutagenic effects on S. typhimurium TA 98. No mutagenic effects were detected for Argion. The type of solvent, dose of the material and incubation as well as the interactions between these factors exhibited varying degrees of influences on the mutagenic activities of the cements (P<0.05 and P<0.1). We conclude that zinc phosphate, polycarboxylate, and glass ionomer cements may have possible mutagenic activities.

Animals↗

The EndoPearl device increases fixation strength and eliminates construct slippage of hamstring tendon grafts with interference screw fixation.

PURPOSE: The EndoPearl (Linvatec, Largo, FL), a biodegradable device to augment the femoral interference screw fixation of hamstring tendon grafts has been developed. The first objective of this study was to compare the initial fixation strength of quadrupled hamstring tendons and biodegradable interference screw fixation with and without the application of the EndoPearl device. The second objective was to determine the influence of the EndoPearl device on the fatigue behavior under incremental cyclic loading conditions in a simulation of critical fixation conditions. TYPE OF STUDY: Biomechanical study. METHODS: Fresh human hamstring tendons were harvested and grafts were fixed with biodegradable poly-L-lactide interference screws. Twenty proximal calf tibias were used to compare the initial fixation strength of the study and the control group. In the study group, the EndoPearl device was secured to the graft using two No. 5 Ethibond sutures (Ethicon, Somerville, NJ). Specimens were loaded until failure in a materials testing machine. For cyclic testing, human hamstring tendons and 20 distal porcine femurs were used. Critical graft fixation conditions were simulated by increasing tunnel diameter 2 mm over the graft diameter. Grafts were loaded progressively in increments of 100 N until failure; 100 cycles were applied per load increment. RESULTS: Graft fixation with the additional EndoPearl device had a significantly higher maximum load to failure (658.9 +/- 118.1 N v 385.9 +/- 185.6 N, P =.003) and stiffness (41.7 +/- 11 N/mm v 25.7 +/- 8.5 N/mm). Graft fixation with the EndoPearl device sustained a significant higher total number of cycles (388.5 +/- 125.6) compared with the control group (152.8 +/- 144.9, P =.002). CONCLUSIONS: We demonstrated that the augmentation of a hamstring tendon graft with the EndoPearl device increases interference screw fixation strength significantly. Under dynamic loading conditions, specimens of the study group sustained substantially higher loads and a larger number of cycles, which indicates a greater resistance to graft slippage. The application of the EndoPearl device may also allow for a secure soft-tissue graft fixation with interference screws in cases of critical fixation conditions.

Absorbable Implants↗

Scapholunate ligament reconstruction using a bone-retinaculum-bone autograft: a biomechanic and histologic study.

A new surgical technique has been recently described that involves reconstruction of the dorsal aspect of the scapholunate ligament (DSLL) with a bone-retinaculum-bone (BRB) autograft preparation from Lister's tubercle. In this study, the mechanic and histologic properties of the 2 tissues were compared. The BRB and DSLL specimens were harvested from 6 fresh-frozen human cadaveric forearms. The specimens were measured and then tested in tension with an MTS 810 servohydraulic materials testing machine at a rate of 10 mm/min. The BRB autograft was significantly weaker than the DSLL. However, because the mean cross-sectional area of the DSLL was more than 3 times as large as that of the BRB autograft, the failure stress (failure force/cross-sectional area) of the BRB autograft was not significantly different from that of the DSLL. Histologically, the DSLL and BRB autograft were also similar. These findings suggest that the BRB autograft may be appropriate graft material for scapholunate ligament reconstruction, but that structural parity with DSLL will ultimately depend on remodeling and hypertrophy during healing. This also highlights the importance of using a large BRB autograft to approximate the strength of the DSLL as much as possible, and that the BRB autograft must be protected postoperatively as it heals and remodels.

Aged↗

Measurement of meniscofemoral contact pressure after repair of bucket-handle tears with biodegradable implants.

INTRODUCTION: Biodegradable implants are frequently used for meniscus repair. Articular cartilage damage has been reported recently after meniscus repair with biodegradable implants. The aim of the study was to investigate the meniscofemoral contact pressure at the posterior horn of the medial and lateral meniscus after repair of bucket-handle lacerations. MATERIALS AND METHODS: Specimens were mounted in a materials testing machine (Bionix 858, MTS) which was equipped with a load cell. The quadriceps tendon was attached to a hydraulic cylinder, and knee motion was controlled via tension of the quadriceps tendon. A piezo-resistive system (Tekscan, Boston, MA, USA) measured the meniscofemoral contact pressure. Five different types of biodegradable implants (Arrow, Dart, Fastener, Stinger and Meniscal Screw) and horizontal suture (no. 2 Ethibond) were tested. The knee was extended from 90 degrees of flexion to 0 degrees under a constant load of 350 N due to adjustment of the tension force of the quadriceps tendon. The femorotibial pressure and contact area were recorded at 0 degree, 30 degrees, 60 degrees and 90 degrees of flexion. RESULTS: The meniscofemoral pressure did not increase after meniscus repair with biodegradable implants or sutures. The meniscofemoral peak pressure at the posterior horn was 1.46+/-1.54 MPa in the medial compartment and 1.08+/-1.17 MPa in the lateral compartment at full knee extension. The meniscofemoral pressure increased significantly in both compartments with knee flexion from 0 degree to 90 degrees. CONCLUSION: Biodegradable implants for meniscus repair do not affect the meniscofemoral pressure. However, there remains a risk of damage to the cartilage when barbed implants are used. If the implant is not entirely advanced into the meniscus, the sharp head or some of the barbs at the column of the implant may come into direct contact with the articular cartilage of the femoral condyle or tibial plateau. The authors presume that incorrect positioning of the implant seems to be the major reason for cartilage damage.

Absorbable Implants↗

Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d,l-lactide, and poly-d,l-lactide-tricalcium phosphate screws.

PURPOSE: The aim of part 1 of this study was to compare the structural properties of tibia-graft-interference screw constructs of soft-tissue graft fixation via the anterior cruciate ligament (ACL) by use of different interference screws. In part 2 the influence of graft laceration as a result of 1 single interference screw insertion on the mechanical properties of the graft was evaluated. METHODS: In part 1 of the study, in a bovine knee model, soft-tissue graft fixation with titanium, biodegradable poly-D,L-lactide (PLDLA), and PLDLA-tricalcium phosphate (TCP) interference screws was performed, and the structural properties were determined by use of a materials testing machine at a rate of 12.5 mm/s. In part 2 the bone was cut after 1 single insertion of titanium, PLDLA, or PLDLA-TCP interference screws, and the mechanical properties of the graft were determined. RESULTS: Soft-tissue graft fixation with a biodegradable PLDLA interference screw showed a statistically significantly higher maximum load when compared with PLDLA-TCP and titanium interference screws. PLDLA-TCP screw fixation revealed a significantly higher ultimate load than titanium screw fixation. The mechanical properties of the grafts after 1 single insertion of PLDLA-TCP interference screws showed a statistically significantly higher stiffness, yield load, and maximum load when compared with the PLDLA and titanium interference screw groups. CONCLUSIONS: The results of this study suggest that the use of a titanium screw to fix a soft-tissue graft in cruciate ligament reconstruction surgery may cause damage to the graft. Soft-tissue ACL reconstruction fixed with a PLDLA interference screw resulted in a significantly higher pullout strength than ACL reconstructions fixed with a PLDLA-TCP or titanium interference screw. CLINICAL RELEVANCE: In contrast to fixation with a biodegradable interference screw, fixation with a titanium interference screw may damage the integrity of a soft-tissue graft in cruciate ligament reconstruction and should therefore be avoided.

Absorbable Implants↗

Cyclic loading of anchor-based rotator cuff repairs: confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation.

Previous experimental studies of failure of rotator cuff repair have involved single pull to ultimate load. Such an experimental design does not represent the cyclic loading conditions experienced in vivo. We created 1 x 2 cm rotator cuff defects in 16 cadaver shoulders, repaired each defect with three Mitek-RC suture anchors (Mitek Surgical Products, Inc, Westwood, MA) using simple sutures of No. 2 Ethibond, and cyclically loaded the repairs by a servohydraulic materials test system actuator at physiological rates and loads (rate of 33 mm/s, load 180 N). A progressive gap was noted in each specimen, for a 100% rate of failure of the repairs. The central suture always failed first and by the largest magnitude, confirming tension overload centrally. One specimen exhibited combined bone and tendon failure, but the other 15 specimens failed through the tendon. Overall, the repairs failed to 5 mm and 10 mm at an average of 61 cycles and 285 cycles, respectively. Half the specimens were less than 45 years of age and had a 5-mm and 10-mm failure at an average of 107 and 478 cycles, respectively. The other half were over 45 years of age and failed to 5 mm and 10 mm at an average of 17 and 91 cycles, respectively, indicating more rapid failure of the rotator cuff tendons in the older group, and this was statistically significant (P < or = .02). Comparison of suture anchor fixation in this study with transosseous bone tunnel fixation in a previous cyclic loading study at this institution indicates that bone fixation by suture anchors is significantly less prone to failure than bone fixation through bone tunnels (P = .0008). Changing the bone fixation from bone tunnels to suture anchors effectively transferred the weak link from bone to tendon.

Adolescent↗