PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microbubbles”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Contrast-enhanced ultrasound for guidance of local tumor ablation.

The objective was to assess the efficacy of sonography with and without contrast medium enhancement in guiding and monitoring percutaneous ethanol ablation of tumors in an animal model. VX-2 carcinoma was implanted into the thighs of New Zealand white rabbits and examined by grey-scale ultrasound, color, power, and pulse Doppler, before and after injection of 95% ethanol into the tumors. Injections of ethanol were guided by ultrasound to sites of tumor vascularity, until all tumor vascularity had been obliterated. Microbubble contrast medium or saline was injected i.v. prior to each of the ultrasonic interrogations. Arteriography was performed before and after ablation. Selected tumor samples were submitted for histologic examination. Contrast enhanced tumor vascularity over saline controls in all cases. In some, incompletely ablated foci of tumor could only be identified with contrast medium enhancement. Arteriography showed complete ablation of all but 1 tumor. We conclude that ultrasound enhanced by contrast better shows the presence or absence of tumor vascularity. Ultrasound enhanced by contrast might offer an accurate means of guiding and monitoring percutaneous ethanol injection for tumor ablation.

Albumins↗

Evaluation of an experimental system for the in vitro assessment of ultrasonic contrast agents.

The ultrasonic properties of microbubble contrast agents need to be fully understood if reproducible images and quantitative results are to be produced. Additional aspects of the physical and chemical environment into which the contrast agents are introduced also need to be taken into account, and their effect on contrast agent performance evaluated. A setup that provides an accurate and reproducible data-acquisition system is presented and evaluated in this paper. The linear range of this system is assessed, as well as its accuracy and precision. A new approach to the investigation of contrast agents, based on normalised backscatter, is discussed. Also, a common technique of degassing, widely used in other areas, is described and evaluated to determine its appropriateness to contrast agent studies.

Contrast Media↗

Protein recovery using gas-liquid dispersions.

Two separation techniques, foam separation and colloidal gas aphrons (CGAs), both of which are based on gas-liquid dispersions, are compared as potential applications for protein recovery in downstream processing. The potential advantages of each method are described and the concentration and selectivity achieved with each method, for a range of proteins is discussed. The physical basis of foam separation is the preferential adsorption of surface active species at a gas-liquid interface, with surface inactive species remaining in bulk solution. When a solution containing surface active species is sparged with gas, a foam is produced at the surface: this foam can be collected, and upon collapse contains surface active species in a concentrated form. CGAs are microbubble dispersions (bubble diameters 10-100 microm) with high gas hold ups (>50%) and relatively high stability, which are formed by stirring a surfactant solution at speeds above a critical value (typically around 5000 rpm). It is expected that when proteins are brought into contact with aphrons, protein adsorbs to the surfactant through electrostatic and/or hydrophobic forces. The aphron phase can be separated easily from the bulk solution due to its buoyancy, thus allowing separation of protein in a concentrated form.

Chemistry Techniques, Analytical↗

Ultrasonic contrast agents: safety considerations reviewed.

Ultrasonic contrast agents are usually comprised of a stabilised shell encapsulating a gas bubble. When these are introduced in the body they increase the acoustic scattering from the tissues through which they pass, and especially from the vasculature. Their primary uses lie in cardiological and oncological imaging. However, these microbubbles have the potential to act as centres for acoustic cavitation activity, and so it is important to consider the safety of their use from an acoustic standpoint. The addition of ultrasonic contrast agents to in vitro suspensions of red blood cells has been shown to lead to haemolysis when the sample is exposed to ultrasound at levels which leave the cells unharmed in their absence. In vivo the infusion of gas bubble contrast agents into experimental animals has been shown to enhance the incidence of petechiae and haemorrhage in the intestine. The Mechanical Index (MI) thresholds for the effects seen in vitro lie within the range of MIs available with diagnostic clinical scanners, but in vivo the thresholds lie at the top end of the exposure levels available clinically. No adverse effects in humans arising from the ultrasonic exposure of these contrast agents have been reported to date.

Animals↗

Multi-centre clinical study evaluating the efficacy of SonoVue (BR1), a new ultrasound contrast agent in Doppler investigation of focal hepatic lesions.

OBJECTIVES: SonoVue is a new ultrasound contrast agent, which consists of stabilised microbubbles of a sulphur hexafluoride gas. The aim of the study was to assess its efficacy in the Doppler investigation of focal hepatic lesions. MATERIALS AND METHODS: Seventy patients with focal liver tumours were studied. Four doses (0.3, 0.6, 1.2 and 2.4 ml) of SonoVue were administered intravenously with at least 10 min delay between each injection. A complete colour/power and spectral Doppler imaging investigation of the lesions was performed at baseline pre-dosing and after each SonoVue injection. All examinations were recorded on SVHS videotapes. Baseline and post contrast videotapes were reviewed by the on-site (un-blinded) investigators and by two off-site blinded readers (a) to grade the global quality of the Doppler scans of the focal lesions vascularity and the normal parenchymal vessels (b) to measure the duration of clinically useful Doppler signal enhancement and (c) to determine the diagnostic accuracy and performance of the enhanced versus unenhanced scans using histopathology, tumour markers, CT and/or MR as the reference standard. RESULTS: A statistically significant improvement was observed at all four SonoVue doses in the off site assessment of global quality of the Doppler examination of tumoral and normal parenchymal vessels in comparison with the baseline (P < 0.05). The median duration of clinically useful enhancement was significantly increased with increasing doses (P < 0.001), ranging between 1.4-2.2 min for the lowest dose and 3.2-3.8 min for the highest dose for the off-site readers. On-site assessment of diagnostic accuracy showed a significant increase in the specificity of the Doppler diagnoses (P < 0.0016) with an increase in the positive and negative predictive values and in the likelihood ratio in differentiating between benign and malignant lesions. Off-site evaluation showed a significant increase in the accuracy of enhanced Doppler diagnosis in comparison with the baseline performance. CONCLUSION: The results suggest that SonoVue is effective in improving the display of tumoral vascularisation and may be useful in the characterisation of focal liver lesions.

Contrast Media↗

Which continuous US scanning mode is optimal for the detection of vascularity in liver lesions when enhanced with a second generation contrast agent?

OBJECTIVES: Microbubble echo-enhancers help in the assessment of focal liver masses by enhancing the signal from blood vessels. A variety of linear and nonlinear scanning modes are now available, but it is unclear which is optimal. A controlled comparison was performed during the infusion of such an agent (SonoVue: Bracco, Milan, Italy). METHODS AND MATERIALS: Ten patients with known focal liver lesions were studied. The diagnoses, confirmed on dual phase helical computed tomography (CT) at the same attendance were metastasis (n = 7), haemangioma (n = 2) and focal nodular hyperplasia FNH (n = 1). A dose of 12 ml SonoVue concentrated at 5 mg/ml was infused intravenously at a rate of 1 ml/min. The enhancement level was monitored with a continuous wave (CW) Doppler probe over the right radial artery and the intensity of the signal was registered at 1 s intervals. When a plateau of enhancement was reached, a single lesion in each patient was imaged using five different continuous scanning modes, fundamental grey scale (FGS); fundamental colour Doppler (FCD); fundamental power Doppler (FPD); second harmonic grey scale (HGS); and pulse inversion mode (Pim) using an HDI5000 scanner and C5-2 probe (ATL, Bothell, WA). The order of scanning modes was varied between patients using a predefined randomisation protocol. The videos (super video home system (SVHS)) were analysed offsite by two blinded readers, both experienced in contrast ultrasound of the liver. The readers were asked to score each mode in terms of its ability to detect vessels within/around the lesion at optimal enhancement. This was done using a ranking system (1, worst; 5, best) for each patient. RESULTS: Both observers scored FPD as the optimal imaging method, followed by Pim. (Scores summed across all patients, observer 1: FPD 48, Pim 42, FCD 37, HGS 21, FGS 10; observer 2: FPD 49, Pim 40, FCD 38, HGS 21, FGS 10). The differences from FPD were significant for FCD, HGS and FGS using a unpaired analysis of variance (ANOVA) comparison, with Bonferroni multiple corrections, (P<0.01, both observers). The differences between FPD and Pim were also significant both for observer 2 and for both observers combined (P<0.01), but did not reach significance for observer 1 (P = 0.19). CONCLUSIONS: In this study, FPD performed best, and the non-linear modes, performed continuously (pulse inversion and second HGS), showed no clear advantage.

Adult↗

Vesicoureteral reflux grading in contrast-enhanced voiding urosonography.

INTRODUCTION AND OBJECTIVE: The sonographic diagnosis of vesicoureteral reflux (VUR) with contrast-enhanced voiding urosonography (VUS) is gradually increasing. With the introduction of VUS as part of the routine diagnostic imaging modalities for reflux significant reduction in the number of voiding cystourethrographies (VCUG) was possible. Like in VCUG grading of reflux in VUS is becoming more and more relevant. The aim of this study was to find out if there are any sonomorphologic and sonomorphometric parameters that would correlate with reflux grading in VCUG. Furthermore, a reflux grading system for VUS is proposed and the correlation of this grading system tested with the one of VCUG. PATIENTS AND METHODS: In one examination session a total of 186 children underwent both VUS and VCUG of whom 89 had VUR in at least one and the same kidney-ureter-unit (KUU) in both diagnostic imagings. The VUS was conducted with intravesical administration of ultrasound (US) contrast medium (Levovist). Ureteral and pelvicalyceal dilatations before administration of US contrast medium and during reflux were documented. Renal pelvic diameter was measured. The density of microbubbles in the renal pelves was scored on a scale of 1-3 (low to high). A grading system for reflux in VUS was set up similar to the international reflux grading system for VCUG with the addition of one more differentiation parameter, namely whether the reflux was primarily in a dilated or non-dilated urinary tract. Reflux grades in VUS were compared with those in VCUG. RESULTS: None of the sonomorphologic and sonomorphometric parameters demonstrated any clear cut finding that would simplify reflux grading in VUS. In 59/95 (62%) KUUs the reflux grades were the same in both examinations. In 10/95 (11%) and 26/95 (27%) KUUs, the reflux was graded lower or higher, respectively, in VUS than in VCUG. Fifty-seven percent were in a primarily dilated system and the remaining 43% in a non-dilated one. Seventy percent of KUUs diagnosed as having grade I reflux in VCUG, showed as grade 2 on VUS. CONCLUSIONS: A reflux grading system similar to the one used in VCUG can be applied in VUS. Adding the parameter reflux into a primarily dilated or non-dilated ureter and/or pelvicalyceal system may bring in a further dimension to the reflux grading in VUS. Most of the refluxes labelled as grade I in VCUG are actually grade II or higher.

Child↗

Determination of perfluorobutane in rat blood by automatic headspace capillary gas chromatography and selected ion monitoring mass spectrometry.

A new contrast agent (Sonazoid; NC100100) for ultrasound imaging has been developed. It is an aqueous suspension of lipid stabilised perfluorobutane (PFB) gas microbubbles. An automatic headspace capillary gas-chromatographic mass spectrometric method using electron impact ionisation was developed for analysis of Sonazoid PFB in rat blood. The calibration standards were gaseous PFB dissolved in ethanol in the range of 0.5-5000 ng PFB. Fluorotrichloromethane (CFC 11) was used as an internal standard of the method and the MS detector was set to single ion monitoring of the base fragment ions of PFB (m/z 69 and 119) and CFC 11 (m/z 101). The calibration graph, made by plotting the peak area ratios of PFB (m/z 69) to CFC 11(m/z 101) against the amount of PFB, was fitted to a second-order polynomial equation with weighting 1/y2 and found to be reproducible. The limit of quantification of the method was set to 0.4 ng PFB. The between-day variation of the method was below 9.2% relative standard deviation (RSD) and the within-day variation of the method was below 7.6% RSD. The accuracy of the method, as compared to Coulter counter, was estimated by determination of PFB in samples where Sonazoid was added to saline and found to range from 91.5% to 105.2%. PFB, added as Sonazoid, was found to be stable for at least 7 months in rat blood samples when stored at -20 degrees C.

Animals↗

Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves.

OBJECTIVES: The present study examined the ability of real-time myocardial contrast echocardiography (MCE) to delineate abnormalities produced by graded coronary stenoses and to correlate signal intensity (SI) parameters derived from destruction/refilling curves with regional myocardial blood flow (MBF) and contractile function. BACKGROUND: Recent technological advances have enabled myocardial opacification by MCE to be achieved during real-time imaging. METHODS: In eight open-chest dogs, we created LAD occlusion and graded stenoses that were either flow-limiting at rest (FLS) or reduced adenosine hyperemia (non-flow-limiting at rest = NFLS). Myocardial contrast echo used Optison infusion and low-energy real-time power pulse inversion imaging. High-energy FLASH frames destroyed bubbles every 15 cardiac cycles. Myocardial SI-versus-time plots were fitted to a one-exponential function to obtain the rate of SI rise (b) and peak SI in the last frame. RESULTS: Dyssynergy was not observed during any NFLS, but perfusion abnormalities were. Visual detection of decreased opacification was possible with severe NFLS and FLS. b demonstrated a significant reduction with severe NFLS and near significant with moderate NFLS; peak SI did not. All exponential parameters were significantly decreased with FL stenosis and occlusion. The MBF ratio in LAD/LCx beds (fluorescent microspheres) correlated with b (r = 0.79) and the product of the peak SI and b (r = 0.80). CONCLUSIONS: In an open-chest dog model, parameters derived from microbubble refilling of the imaging field by real-time MCE correlate well with myocardial blood flow and can identify coronary stenosis.

Albumins↗

Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography.

OBJECTIVES: We sought to determine the feasibility and accuracy of real-time imaging of myocardial contrast echocardiography (MCE) in detecting myocardial perfusion defects during exercise echocardiography compared with radionuclide tomography. BACKGROUND: Ultrasound imaging at a low mechanical index and frame rate (10 to 20 Hz) after intravenous injections of perfluorocarbon containing microbubbles has the potential to evaluate myocardial perfusion and wall motion (WVM) simultaneously and in real time. METHODS: One hundred consecutive patients with intermediate-to-high probability of coronary artery disease underwent treadmill (n = 50) or supine bicycle (n = 50) exercise echocardiography. Segmental perfusion with MCE and WM w ere assessed in real time before and at peak exercise using low mechanical index (0.3) and frame rates of 10 to 20 Hz after 0.3 ml bolus injections of intravenous Optison (Mallinckrodt Inc., San Diego, California). All patients had a dual isotope (rest thallium-201, stress sestamibi) study performed during the same exercise session, and 44 patients had subsequent quantitative coronary angiography. RESULTS: In the 100 patients, agreement between MCE and single photon emission computed tomography (SPECT) was 76%, while it was 88% between MCE and WM assessment. Compared with quantitative angiography, sensitivity of MCE, SPECT and WM was comparable (75%), with a specificity ranging from 81% to 100%. The combination of MCE and WM had the best balance between sensitivity and specificity (86% and 88%,respectively) with the highest accuracy (86%). CONCLUSIONS: The real-time assessment of myocardial perfusion during exercise stress echocardiography can be achieved with imaging at low mechanical index and frame rates. The combination of WM and MCE correlates well with SPECT and is a promising important addition to conventional stress echocardiography.

Adult↗

Pressure-derived collateral flow index as a parameter of microvascular dysfunction in acute myocardial infarction.

OBJECTIVES: The goal of this study was to examine the implications of the pressure-derived collateral flow index (CFIp) in acute myocardial infarction (AMI). BACKGROUND: Higher CFIp is associated with less severe myocardial ischemia during angioplasty in the non-infarcted heart. It remains unknown whether CFIp also identifies collateral function in AMI patients with and without no-reflow phenomenon. METHODS: The study population included 48 patients with a first AMI. After successful percutaneous transluminal coronary angioplasty (PTCA) stent, we measured mean aortic pressure (Pa), central venous pressure (Pv) and coronary wedge pressure (Pcw) of the infarct-related artery to calculate: CFIp = (Pcw - Pv)/(Pa - Pv). Myocardial contrast echocardiography (MCE) was performed with the intracoronary injection of microbubbles to assess myocardial perfusion. Left ventriculograms at days 1 and 28 were provided for the measurement of the regional wall motion (RWM, SD/chord). RESULTS: There was no difference in CFIp among subsets based on angiographic collateral grades (grade 0, 1, 2, 3; 0.28 +/- 0.07, 0.27 +/- 0.09, 0.27 +/- 0.08, 0.23 +/- 0.08, p = NS). The CFIp was significantly higher in patients with MCE no-reflow (n = 16) than in those with MCE reflow (n = 32) (0.34 +/- 0.07 vs. 0.23 +/- 0.06, p < 0.01). There was a significant inverse correlation between the extent of functional improvement (DeltaRWM[28 d-1 d]) and CFIp (r = 0.56, p < 0.01), implying that higher CFIp is associated with worse functional improvement. CONCLUSIONS: In AMI, CFIp is unlikely to reflect collateral function but seems to increase with the severity of microvascular dysfunction. Because higher CFIp was associated with poorer functional recovery, it provides a simple and useful estimate of clinical outcomes in AMI.

Aged↗

Myocardial and microcirculatory kinetics of BR14, a novel third-generation intravenous ultrasound contrast agent.

OBJECTIVES: This study sought to investigate the myocardial and microvascular kinetics of BR14, a novel third-generation ultrasound contrast agent. BACKGROUND: BR14 produces persistent myocardial opacification after the administration of a single intravenous bolus when the left ventricular cavity contrast has considerably diminished. The mechanism of this finding is unknown. METHODS: Nine open-chest dogs with non-critical stenosis of a single coronary artery were given intravenous bolus injections of BR14 during coronary hyperemia. Time versus acoustic intensity (AI) plots were generated from the normal and stenosed beds and myocardial blood flow (MBF) was measured with radiolabeled microspheres. Intravital microscopy was performed on an exteriorized cremaster muscle in 11 wild-type mice to study the microvascular kinetics of the agent. RESULTS: At peak contrast enhancement, the ratio between AI in the stenosed and normal bed was 0.44+/-0.23, which was similar to the radiolabeled microsphere-derived MBF ratio between the two beds (0.45 +/-0.20). At 400 s after injection, the AI ratio between the two beds approximated unity (0.99+/-0.07) despite no changes in MBF, indicating redistribution of the agent. The myocardial kinetics of BR14 was best characterized by a modified lagged normal density function. Only about 3% of administered microbubbles were estimated to be retained in the myocardium. Intravital microscopy showed that most of these bubbles were retained only transiently (2 to 3 s) within capillaries. CONCLUSIONS: BR14 demonstrates redistribution because of transient retention within capillaries. Therefore, similar to (201)Tl, it could potentially be used to detect both coronary stenosis and myocardial viability after a single injection during stress.

Animals↗

Contrast echocardiography can assess risk area and infarct size during coronary occlusion and reperfusion: experimental validation.

OBJECTIVES: We sought to validate the ability of real-time myocardial contrast echocardiography (MCE) measures of opacification defect and contrast refilling parameters to estimate risk area (RA) and infarct area (IA) during coronary occlusion and reperfusion. BACKGROUND: No data exist establishing the accuracy of MCE in determining RA and IA size. We hypothesized that in the setting of coronary occlusion, MCE should identify RA as a perfusion defect early after bubble destruction, collateral flow to viable myocardium as opacification late during refilling and IA as absent opacification. METHODS: Three hours of coronary occlusion and reperfusion were each produced in 11 dogs in which real-time MCE was performed during intravenous infusion of Sonovue (Bracco). Real-time contrast echocardiography was performed at baseline, during occlusion and reperfusion. Early (BEGIN) and end (END) images from a FLASH refilling sequence were acquired, as well as late refilling images (LATE) 1 min after FLASH. Real-time contrast echocardiography defect size and quantitative refilling parameters were compared with RA and IA determined by tissue staining. RESULTS: During occlusion, defect size varied with refilling time; defects from BEGIN images correlated best to RA and those from LATE images to IA. Refilling parameters, but not LATE peak intensity, did not predict the IA size during occlusion. During reperfusion, defects from BEGIN images were well correlated to RA and END images to IA, whereas peak plateau intensity and refilling slope parameters predicted IA size. CONCLUSIONS: Real-time contrast echocardiography defect size varies throughout microbubble refilling. Appropriately selected defect sizes and refilling parameters provide estimates of RA and IA during coronary occlusion and reperfusion.

Animals↗

Dobutamine versus dipyridamole for inducing reversible perfusion defects in chronic multivessel coronary artery stenosis.

OBJECTIVES: We hypothesized that, although the effects of dipyridamole and dobutamine on myocardial blood volume (MBV) and mean microbubble velocity (VEL) are different, the magnitude of perfusion deficit during both forms of stress is the same because both drugs unmask abnormal myocardial blood flow (MBF) reserve. BACKGROUND: Both dipyridamole and dobutamine are used clinically as pharmacologic stress agents to induce reversible perfusion defects in patients with chronic coronary artery disease (CAD), but the basis for doing so for dobutamine is not clear. METHODS: Eleven chronically instrumented closed-chest dogs with multivessel coronary stenosis were studied. Hemodynamics, radiolabeled microsphere-derived MBF, and myocardial contrast echocardiography (MCE)-derived myocardial perfusion were measured at rest, after dipyridamole infusion (0.56 mg x kg(-1)), and at peak dobutamine dose (either 30 or 40 microg x kg(-1) x min(-1)). Abnormal beds were defined as those demonstrating an MBF reserve <3 with dipyridamole. RESULTS: In the presence of either drug, MBV increased more in the normal bed than in the abnormal bed, but the increase was higher in both beds with dobutamine than with dipyridamole. The slope of the relationship between MBF reserve and MBV reserve was greater during dobutamine than dipyridamole (p < 0.05). The converse was true for VEL reserve (p < 0.05). Consequently, the relationship between the ratios of either variable, or the product of the two, between the abnormal bed and normal bed was similar for both drugs. CONCLUSIONS: Although the effects of dipyridamole and dobutamine on MBV and VEL are different, both are equally effective in detecting physiologically relevant coronary stenoses on MCE. Both can therefore be used interchangeably with myocardial perfusion imaging for the detection of CAD.

Animals↗

Quantitative assessment of coronary stenosis by harmonic power Doppler with a simple pulsing sequence and vasodilator stress in patients.

OBJECTIVES: We examined whether myocardial contrast echocardiography (MCE) with harmonic power Doppler (HPD) employing a simple ultrasound pulsing sequence enables estimation of the severity of coronary artery stenosis in patients. BACKGROUND: Contrast intensity (CI) during MCE with intravenous microbubble infusion is dependent on the myocardial blood flow velocity (MBFV) and pulsing interval (PI). METHODS: Based on an in vitro experiment, we devised the MBFV index calculated as the reciprocal of the magnitude of CI decay produced by abrupt PI shortening during intermittent imaging. In 68 coronary artery territories from 49 patients, myocardial HPD images were acquired during intravenous infusion of Levovist, while the long PI with 1:10 electrocardiographic gating was shortened to 1:1, both at baseline and during adenosine triphosphate infusion. The MBFV index in each coronary territory and MBFV reserve as the ratio between hyperemia and baseline were compared with the severity of corresponding coronary artery stenosis assessed by quantitative coronary angiography (QCA) or by pressure guide wire as the fractional flow reserve (FFR). RESULTS: Both the MCE-derived MBFV index during hyperemia and MBFV reserve exhibited significant negative correlations with the QCA-derived stenosis severity (r = -0.56 and r = -0.64, respectively). The MBFV reserve positively correlated with FFR (r = 0.89). By combining the cutoff values of the MBFV index during hyperemia and MBFV reserve, > or =75% of stenoses defined by QCA were determined, with a sensitivity of 77.3%, specificity of 93.4%, and accuracy of 88.3%. CONCLUSIONS: Shortening of PI during intravenous MCE with intermittent HPD imaging under vasodilator stress enables assessment of coronary artery stenoses in patients.

Adult↗

Intraoperative contrast echocardiography to evaluate mitral valve operations.

Intraoperative two-dimensional contrast echocardiography was performed on 29 patients undergoing open heart surgery to determine the presence of mitral regurgitation before and immediately after the operative procedure: 14 patients had predominant mitral stenosis, 9 had severe mitral regurgitation and 6 had no mitral valve disease (control subjects). Two-dimensional echocardiography was performed by applying a 5 MHz transducer directly on the heart during injection of saline solution through an apical ventricular sump or transseptal needle, generating contrast microbubbles, with imaging in two planes. Baseline studies were performed after thoracotomy and pericardiotomy before cardiopulmonary bypass, and a second study was done after the operative procedure, with the patient off cardiopulmonary bypass with hemodynamic stabilization before chest closure. No control subject had contrast evidence of mitral regurgitation before or after cardiopulmonary bypass. Two of three patients with mitral valvuloplasty and two of five with commissurotomy required a second operative procedure before chest closure because of persistent mitral regurgitation detected by intraoperative two-dimensional contrast echocardiography. Thirteen of the 15 patients with valve replacement had no mitral regurgitation after cardiopulmonary bypass. Intraoperative two-dimensional echocardiographic findings correlated with data from postoperative clinical examinations and two-dimensional echocardiography-Doppler studies. It is concluded that two-dimensional echocardiography with contrast is an important intraoperative tool for assessing the presence and relative severity of mitral regurgitation after mitral commissurotomy, valvuloplasty or valve replacement. This technique may allow surgeons to be more aggressive in combining reparative operative procedures (that is, commissurotomy and valvuloplasty) in an attempt to retain native valves.

Adult↗

Myocardial contrast two-dimensional echocardiography: experimental examination at different coronary flow levels.

Regional myocardial echo contrast appearance-disappearance after intracoronary contrast agent injection was examined with computerized two-dimensional contrast echocardiography in eight open chest dogs during successive variation of the coronary blood supply. A new sonication method applied to dextrose 50% produced an echo contrast agent with a microbubble size of 12 +/- 6 mu (mean +/- standard deviation), and 1 cc of this agent was injected into a coronary artery during the echocardiographic study of the left ventricle. Left anterior descending or circumflex coronary artery flow, measured by electromagnetic flowmeter, was successively reduced up to 90% with an extravascular hydraulic occluder, or else increased 40 to 60% through intravenous dipyridamole infusion (7 to 10 micrograms/kg per min). The corresponding myocardial echo time-intensity curves were analyzed for each of 12 segments of a midventricular short-axis cross section. Several potential indexes of myocardial perfusion were derived: peak echo contrast intensity, time from echo contrast appearance to peak intensity, half-life of echo contrast decay phase (T 1/2) and total duration of contrast appearance-disappearance. Except for peak intensity, all of these indexes provided significant (p less than 0.05) differentiation between control coronary flow (66 +/- 17 ml/min) and greater than 50% flow reductions (26 +/- 6 ml/min) or hyperemia (115 +/- 17 ml/min). Half-life values were 5.2 +/- 0.3 seconds for the control state, 9 +/- 2 seconds for the reduced coronary flow and 2 +/- 2 seconds for dipyridamole hyperemia.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Intraoperative two-dimensional echocardiography: new application of an old technique.

Intraoperative two-dimensional echocardiography is a new diagnostic and monitoring technique that provides immediate information, unavailable from routine hemodynamic measurements, on both myocardial and valvular function. The presence and severity of valvular regurgitation can be assessed from the visualized flow pattern of microbubbles generated by an injection of saline solution: reflux flow into the retrograde chamber represents valvular insufficiency. The extent of valvular regurgitation can be determined immediately after conservative valve repair (annuloplasty or commissurotomy) or replacement to avoid the patient's leaving the operating suite with significant but undetected valvular insufficiency. Additionally, intraoperative echocardiography permits rapid evaluation of left ventricular systolic and diastolic volumes and myocardial contractility, thereby facilitating therapeutic interventions in the operating room. It also permits assessment of congenital heart defects and the competency of their repair. Pulsed, continuous and color-flow real time Doppler imaging methods allow further intraoperative definition of stenotic and regurgitant lesions.

Aortic Valve Insufficiency↗