PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Particulate Matter”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Acute effects of a winter air pollution episode on pulmonary function and respiratory symptoms of children.

The acute respiratory effects of a wintertime air pollution episode were studied in a general population sample of 112 children who were 7-12 y of age and who lived in a nonurban community. Spirometry was performed on 6 d, with a fixed interval of 3 wk between successive tests. During an air pollution episode, an additional pulmonary function test was made. Acute respiratory symptoms of the children were noted in a diary. Ambient concentrations of sulfur dioxide, black smoke, particulate matter with an aerodynamic diameter less than 10 microns, and nitrogen dioxide were considered as exposure variables. The association of air pollution with pulmonary function and prevalence of acute respiratory symptoms was assessed by individual linear regression analysis and time series analysis, respectively. In February 1991, an air pollution episode occurred during which daily average sulfur dioxide concentrations were slightly above 100 micrograms/m3, and particulate matter (with an aerodynamic diameter of less than 10 microns) concentrations reached 174 micrograms/m3. During the episode, forced vital capacity, forced expiratory volume in 1 s, and maximal mid-expiratory flow were lower than on baseline tests. Significant negative associations were found between the concentration of sulfur dioxide, black smoke, and particulate matter with an aerodynamic diameter of less than 10 microns. No association between prevalence of acute respiratory symptoms and the concentration of these compounds was found.

Acute Disease↗

[Mutagenicity of 3 organic fractions of atmospheric dust and gas chromatographic analysis of the basic fraction].

Suspended particulate matter (PM) with a Dae less than 0.4 micron was collected from July 1981 till January 1982. The ether/benzene soluble extract (EEOM) and the acidic, basic and neutral fractions were determined and investigated for their mutagenic activities in the Ames bioassay. In addition particles (Dae) less than 10.2 micron derived in January were investigated. Five compounds of the basic fraction were determined by gaschromatography. The following results were obtained: Suspended particulate matter (Dae less than 0.4 micron) and the ether/benzene extract increase from July to January. The lowest rates occur in July (PM: 16.9 micron/m3) and August (EEOM: 3.0 micrograms/m3), the highest in January (PM: 48.9 micrograms/m3, EEOM: 10.5 micrograms/m3). The ether/benzene soluble portion of the suspended particulate matter increases from the average rate of 16.3% (July-September) to 22.7% (November-January). The neutral fraction amounts to 44.9%, the acidic fraction to 27.3% and the basic fraction to 3.5% of the organic matter (on an average). In experiments with metabolic activation 99% of the total mutagenicity during the period of July till September can be demonstrated by summing up the mutagenicity of the three fractions on the other hand only 59.7% from November till January. The EEOMs derived from winter exhibit without metabolic activation (250 micrograms/plate) distinctively higher numbers of revertants than the single fractions. Dose-response curves of extracts derived from back-up filters (Dae less than 0.4 micron) in January show that the acidic fraction has a slightly higher mutagenic activity than the neutral fraction (mean values of tests with and without S9-mix). The basic fraction shows no mutagenicity without S9-mix, with activation the mutagenic activity is lower than that of the other fractions. Mutagenicity expressed as rev./m3 air shows, that the neutral fraction is most efficient. The number of revertants per plate reveals-in relation to the particle size-different results concerning the three fractions (January).

Acridines↗

Particle-bound benzene from diesel engine exhaust.

OBJECTIVES: The large surface area of the carbon core of diesel exhaust particles may contribute to the adsorption or condensation of such volatile carcinogenic organic compounds as benzene. The attention of this study focused on determining the distribution of benzene between the gas and particulate phases in the breathing zone of bus garage workers. METHODS: Benzene and suspended particulate matter were evaluated jointly in the air of a municipal bus garage. Personal passive monitors were used for benzene sampling in the breathing zone of the workers. Active samplers were used for sampling diesel exhaust particles and the benzene associated with them. The benzene levels were measured by gas chromatography. RESULTS: Diesel engine exhaust from buses was the main source of air pollution caused by benzene and particles in this study. The concentration of benzene in the gas and particulate phases showed a wide range of variation, depending on the distance of the workplace from the operating diesel engine. Benzene present in the breathing zone of the workers was distributed between the gas and particulate phases. The amounts of benzene associated with particles were significantly lower in summer than in winter. CONCLUSIONS: The particulate matter of diesel exhaust contains benzene in amounts comparable to the concentrations of carcinogenic polycyclic aromatic hydrocarbons (PAH) and the usually found nitro-PAH. The concentration of benzene in the gas phase and in the suspended particulate matter of air can serve as an additional indicator of exposure to diesel exhaust and its carcinogenicity.

Analysis of Variance↗

Analysis of contaminants in factor VIII preparations administered to patients with hemophilia.

Cryoprecipitate and the more purified factor VIII concentrates are all heterogeneous preparations that contain not only a high concentration of factor VIII but also various other materials, some of which might be injurious, causing liver damage after long-term exposure. The efficiency of three standard cryoprecipitate filters, two microaggregate filters and the appropriate factor VIII concentrate filters in reducing the amount of particulate matter delivered to the patient was assessed. Filtration of cryoprecipitate through the standard filters removed less than 20% of the contaminating microaggregates and very few of the large number of intact platelets, although the total dose of factor VIII was delivered. Microaggregate filters were no better in reducing the platelet contamination, although the total number of particles delivered was halved. However, 25% of the factor VIII was retained in the bed volume of the filter. The concentrate preparations also contained significant amounts of particulate matter that was unrelated to factor VIII and was not removed following filtration through the designated filter. These findings indicate that a new filter should be developed for administration of factor VIII concentrate that would remove the particulate matter while delivering all of the factor VIII to the patient.

Diethylhexyl Phthalate↗

Evaluation of acceptance criteria for particulate limits for small-volume parenteral products.

The precision of and correlation between the USP membrane filtration-microscopic method and the instrumental method for sizing and quantifying particulate matter in small-volume parenteral products were determined using simulated products. The total variance for the instrumental counts was lower than the USP method for all products in the 10--25-mum particle range and for most products in the greater than or equal to 25--50-mum range. A linear relationship between the instrumental counts and the USP counts was demonstrated for the 10--25-mum particle range. However, the instrumental reading was higher than the USP method for counts of 10 or more particles/ml. The instrumental and the USP methods failed to correlate on particulate sizes greater than 25 mum. The content of particulate matter in over 100 small-volume parenteral products was sized and quantified by the USP and the instrumental methods. From the instrumental data, a statistical treatment for the analysis of particulate data is presented as an objective method of evaluating acceptance criteria on particulate matter in small-volume parenteral products.

Autoanalysis↗

Development of an international standard for the determination of metals and metalloids in workplace air using ICP-AES: evaluation of sample dissolution procedures through an interlaboratory trial.

Inductively coupled plasma atomic emission spectrometry (ICP-AES) is rapidly overtaking atomic absorption spectrometry (AAS) as the method of choice for the determination of toxic metals in workplace air. However, the few ICP-AES methods that have been published are not well characterised in terms of the effectiveness of the sample dissolution procedures described and their validation status. The International Standards Organization (ISO) is currently engaged in developing ISO 15202, which will describe a generic method for the determination of metals and metalloids in airborne particulate matter by ICP-AES. One part of the proposed standard deals with dissolution procedures. The ISO work has been supported by a project carried out in the authors' laboratory to identify, develop and validate sample dissolution procedures for inclusion in the proposed standard. This paper describes an interlaboratory comparison carried out to assess the performance of selected procedures using samples of airborne particulate matter collected on filters with a multiport sampler. Five dissolution procedures were tested. These included an ultrasonic agitation procedure, two hot-plate procedures (based upon NIOSH 7300 and OSHA ID 125G) and two microwave-assisted procedures (based upon EPA 3052). It was shown that the dissolution procedures selected for use in the trial and used internally at HSL generally gave equivalent performance. As expected, a wider spread of results was obtained by participants in the trial. More specifically, there exists some reservation regarding the ability of the ultrasonic and hot-plate procedures to attack fully on a consistent basis some resistant materials, e.g., chromium containing particulate matter. Above all, the trial demonstrated the usefulness of microwave-assisted dissolution procedures in a modern laboratory.

Calibration↗

The relationship between selected causes of postneonatal infant mortality and particulate air pollution in the United States.

Recent studies have found associations between particulate air pollution and total and adult mortality. The relationship between particulate air pollution and mortality among infants has not been examined in the United States. This study evaluates the relationship between postneonatal infant mortality and particulate matter in the United States. Our study involved analysis of cohorts consisting of approximately 4 million infants born between 1989 and 1991 in states that report relevant covariates; this included 86 metropolitan statistical areas (MSAs) in the United States. Data from the National Center for Health Statistics-linked birth/infant death records were combined at the MSA level with measurements of particulate matter 10 microns or less (PM10) from the EPA's Aerometric Database. Infants were categorized as having high, medium, or low exposures based on tertiles of PM10. Total and cause-specific postneonatal mortality rates were examined using logistic regression to control for demographic and environmental factors. Overall postneonatal mortality rates were 3.1 among infants with low PM10 exposures, 3.5 among infants with medium PM10 exposures, and 3.7 among highly exposed infants. After adjustment for other covariates, the odds ratio (OR) and 95% confidence intervals (CI) for total postneonatal mortality for the high exposure versus the low exposure group was 1.10 (1.04, 1.16). In normal birth weight infants, high PM10 exposure was associated with respiratory causes [OR = 1.40, (1.05, 1.85)] and sudden infant death syndrome [OR = 1.26, (1.14, 1.39)]. For low birth weight babies, high PM10 exposure was associated, but not significantly, with mortality from respiratory causes [OR = 1.18, (0.86, 1.61)]. This study suggests that particulate matter is associated with risk of postneonatal mortality. Continued attention should be paid to air quality to ensure optimal health of infants in the United States.

Air Pollution↗

[Intravenous (i.v.) fluid administration systems and incompatibility of injection].

The safety of the injection therapy has to be secured including that of the injection itself as well as that of the equipment used for injection, i.e. i.v. fluid administration systems. The contamination of insoluble particulate matter ascribed to coating of silicone oil over disposable syringe is being solved by the development of syringe using fluoro-resin laminated rubber. In the case of blood administration set and blood bag system, there are some in which the solvent used for adhesion has been eluted. Further, the relationship between the quality of materials of administration set and the adsorption of drugs has become clear. As regards the plastic container for infusion, insoluble particulate matter and adsorption of drugs have become a problem in connection with the quality of materials used and yet the structure of plastic/rubber combined cap is related to the formation of core, thereby making the improvement. In the case of plastic bag, that made of polyethylene does not adsorb drugs so much and the formation of insoluble particulate matter is a little. For the measures of drug interaction of injection, i.v. fluid administration systems have been applied and the safe and effective method of administration of injection will be established along with the development of I.V. delivery system.

Adsorption↗

Control of glycolytic enzyme binding: effect of changing enzyme substrate concentrations on in vivo enzyme distributions.

The effect of changing concentrations of glycolytic intermediates on the binding of phosphofructokinase, aldolase and pyruvate kinase to cellular particulate matter was investigated. Concentrations of glycolytic intermediates were altered by adding 2 mM iodoacetic acid (IAA) to an incubation medium containing tissues isolated from the channelled whelk Busycon canaliculatum. Iodoacetic acid inhibited glyceraldehyde 3-phosphate dehydrogenase activity causing a 100-400 fold increase in the concentration of fructose 1,6-bisphosphate as well as 3-20 fold increases in glucose 6-phosphate, fructose 6-phosphate, and dihydroxyacetone phosphate levels depending on the experimental protocol. Cellular pH values were not statistically different in the presence of IAA. Measurement of enzyme binding to particulate matter showed that the binding of phosphofructokinase, aldolase and pyruvate kinase was unaffected by iodoacetic acid under any experimental condition. These results show that changes in the tissue concentrations of enzyme substrates and products do not regulate enzyme binding to particulate matter in the cell.

Animals↗

Characterization and source identification of polycyclic aromatic hydrocarbons (PAHs) in the urban environment of Delhi.

This paper reports on polycyclic aromatic hydrocarbons (PAHs) in the atmospheric particulate matter of Jawaharlal Nehru University campus, an urbanized site of New Delhi, India. Suspended particulate matter samples of 24h duration were collected on glass-fiber filter paper for four representative days in each month during January 2002 to December 2003. PAHs were extracted from filter papers using toluene with ultrasonication method and analysed. Quantitative measurements of polycyclic aromatic hydrocarbons (PAHs) were carried out using the gas chromatography technique. The annual average concentration of total PAHs were found to be 668+/-399 and 672+/-388 ng/m3 in the years 2002 and 2003, respectively. The seasonal average concentrations were found to be maximum in winter and minimum during in the monsoon. The results of principal component analysis (PCA) indicate that diesel and gasoline driven vehicles are the principal sources of PAHs in all the seasons. In winter coal and wood combustion also significantly contribute to the PAH levels.

Air Pollutants↗

Effects of ambient air pollution on upper and lower respiratory symptoms and peak expiratory flow in children.

BACKGROUND: Previous epidemiological studies have shown acute effects of increased amounts of ambient air pollution on the prevalence of respiratory symptoms in children with respiratory disorders. We investigated whether children with bronchial hyperresponsiveness (BHR) and relatively high serum concentrations of total IgE (>60 kU/L, the median value) are susceptible to air pollution. METHODS: We collected data from children during three winters (1992-95) in rural and urban areas of the Netherlands. Lower respiratory symptoms (wheeze, attacks of wheezing, shortness of breath), upper respiratory symptoms (sore throat, runny or blocked nose), and peak expiratory flow were recorded daily for 3 months. The acute effects of airborne particulate matter with a diameter of less than 10 microm, black smoke, sulphur dioxide, and nitrogen dioxide were estimated by logistic regression. FINDINGS: 459 (73%) of 632 children had complete data. Of these, 26% had BHR and relatively high (above median) serum total IgE, 36% had no BHR and total IgE of 60 kU/L or less, 15% had BHR and total IgE of 60 kU/L or less, and 23% had a total IgE of more than 60 kU/L but no BHR. In children with BHR and relatively high serum total IgE the prevalence of lower respiratory symptoms increased significantly by between 32% and 139% for each 100 microm/m3 increase in particulate matter, and between 16% and 131% for each 40 microm/m3 increase in black smoke, SO2, or NO2. Decrease in peak expiratory flow of more than 10% in that group was more common with increased airborne particulate matter and black smoke. There were no consistent positive or negative associations between increased air pollution and prevalence of respiratory symptoms or decrease in peak expiratory flow in the other three groups of children. INTERPRETATION: Children with BHR and relatively high concentrations of serum total IgE are susceptible to air pollution. Although our odds ratios were rather low (range 1.16-2.39) the overall effect of air pollution on public health is likely to be substantial since these odds ratios refer to large numbers of people.

Air Pollutants↗

Public exposure to environmental tobacco smoke.

Airborne particulate matter has been collected by personal samplers in public indoor areas and travel situations with environmental tobacco smoke pollution. Following extraction, the samples were assayed for mutagenicity in the presence of S9 with a sensitive microsuspension test using Salmonella TA98. The mutagenic responses of indoor air from public areas were much higher than those of ambient outdoor air. Depending on the circumstances, the mutagenic response varied in trains and airplanes but the results show that physical separation of non-smoking sections from smoking sections is necessary in order to achieve genuine non-smoking areas. Chemical fractionation and mutagenicity assay of the basic fraction show that Salmonella mutagenicity of airborne particulate matter might be used as a tobacco smoke-specific indicator, as the basic fraction of environmental tobacco smoke contains a large part of the mutagenic activity whereas this is not the case for outdoor ambient airborne particulate matter.

Air Pollutants↗

Biphasic culture of rat lung slices for pharmacotoxicological evaluation of complex atmospheres.

The relevance to the in vivo situation of in vitro toxicity studies of complex atmospheres has frequently been limited by the procedures used for the exposure of the biological samples. We have evaluated from on-road measurements the size distribution pattern and the subsequent respiratory tract deposition rates of particulate matter from urban atmospheric aerosols, which are in the range of 110 and 3 pg/cm2 per min for tracheobronchial and alveolar areas, respectively. Continuous flow-through rotating chambers and a specific design for exhaust sampling and dilution with controlled adjustment of pO2 and pCO2 to 20% and 5%, respectively, have been developed to expose biphasic air/liquid organotypic cultures of rat lung slices to continuous flows of diluted exhausts from diesel engines with preservation of the physicochemical properties of the exhaust. The size distribution of the particulate matter and the bioavailability of pollutants were preserved, thus allowing us to closely mimic in vitro the in vivo atmosphere/tissue interactions that occur mainly through diffusion mechanisms. The toxicity response profile has been assessed in terms of tissue viability, oxidative stress, DNA injury, and the early phase of inflammatory reaction. Exhaust filtration, addition to fuel of rapeseed methyl ester, and preincubation of lung tissue with soy isoflavones modulated the toxicity response profile of exhausts. The importance of preserving both particulate matter size distribution and adsorbed pollutant bioavailability, which could not be ascertained using more classical in vitro approaches, is discussed and should be considered a prerequisite for further developments of in vitro studies to modelize in vivo inhalation of complex atmospheres.

Aerosols↗

Effects of air pollution on the respiratory health of asthmatic children living in Mexico City.

The relation between air pollution and the exacerbation of childhood asthma was studied in a panel of 71 children (aged 5 to 7 yr) with mild asthma who resided in the northern part of mexico City. During the follow-up, ambient measures of particulate matter less than 10 microns (PM10, 24-h average) and ozone (1-h maximum) frequently exceeded the Mexican standards for these contaminants. The peak expiratory flow rate (PEFR) was strongly associated with PM10 levels and marginally with ozone levels. Respiratory symptoms (coughing, phlegm production, wheezing, and difficulty breathing) were associated with both PM10 and ozone levels. An increase of 20 micrograms/m3 of PM10 was related to an 8% increase in lower respiratory illness (LRI) among children on the same day (95% confidence interval [CI] = 1.04-1.15), and an increase of 10 micrograms/m3 in the weekly mean of particulate matter less than 2.5 microns (PM2.5) was related to a 21% increase in LRI (95% CI = 1.08-1.35). A 50 parts per billion (ppb) increase in ozone was associated with a 9% increase in LRI (95% CI = 1.03-1.15) on the same day. We concluded that children with mild asthma are affected by the high ambient levels of particulate matter and ozone observed in the northern part of Mexico City.

Air Pollutants↗

Genetic toxicology studies comparing the activity of sidestream smoke from cigarettes which burn or only heat tobacco.

The results of in vitro genetic toxicology studies of sidestream cigarette smoke (SSCS) from cigarettes which heat but do not burn tobacco were compared to those of sidestream smoke from cigarettes which burn tobacco. SSCSs from 5 cigarettes were compared. Three of the cigarettes, the Kentucky reference research cigarette (1R4F), a commercially available ultra-low-tar brand (ULT) and a commercially available ultra-low-tar menthol brand (ULT-menthol) burn tobacco while two of the cigarettes, a regular (TEST) and a menthol (TEST-menthol) heat tobacco. SSCSs from all cigarettes were prepared by identical techniques, which involved collecting sidestream smoke particulate matter on Cambridge filter pads and combining the particulate matter with the vapor-phase materials collected by bubbling the smoke exiting the Cambridge pad through DMSO. The SSCSs obtained (equivalent to 0.4 cigarettes/ml DMSO) were evaluated at identical concentrations in an in vitro genetic toxicology test battery. SSCS from 1R4F, ULT and ULT-menthol cigarettes produced positive results in Ames bacterial strains TA98, TA100, TA1537 and TA1538 in the presence of metabolic activation (S9 from Aroclor-induced rat liver) but negative results in strain TA1535. In the absence of metabolic activation, 1R4F, ULT and ULT-menthol SSCSs were not significantly mutagenic. TEST and TEST-menthol SSCSs produced negative results in all 5 bacterial strains, both with and without metabolic activation. SSCS from 1R4F, ULT and ULT-menthol cigarettes produced positive results in the CHO chromosomal aberration assay and in the CHO sister-chromatid exchange assay both with and without metabolic activation while TEST and TEST-menthol SSCSs produced negative results in both assays, either with or without metabolic activation. The SSCSs from 1R4F, ULT and ULT-menthol cigarettes were weakly positive in inducing DNA repair in cultured rat hepatocytes while TEST and TEST-menthol SSCSs were negative in this assay. All 5 SSCSs were nonmutagenic in the CHO-HGPRT assay both with and without metabolic activation. SSCSs from the 1R4F, ULT and ULT-menthol cigarettes were cytotoxic in the CHO-HGPRT assay, both with and without metabolic activation, while TEST and TEST-menthol SSCSs were not cytotoxic under either condition. These results demonstrate that sidestream smoke from cigarettes which heat but do not burn tobacco (TEST and TEST-menthol) was neither genotoxic nor cytotoxic under conditions where sidestream smoke from cigarettes which burn tobacco (1R4F, ULT and ULT-menthol) was genotoxic and/or cytotoxic in a concentration-dependent manner.

Animals↗

Airborne mouse allergen in the homes of inner-city children with asthma.

BACKGROUND: Airborne mouse allergen has not previously been measured in inner-city homes, and its relationship to settled dust mouse allergen levels is unknown. OBJECTIVE: To quantify airborne and settled dust Mus m 1 levels in homes of inner-city patients with asthma and to identify risk factors for mouse allergen exposure. METHODS: One hundred inner-city school-age children with asthma in Baltimore underwent skin testing to a panel of aeroallergens, and their homes were inspected by a trained technician. Air and settled dust were sampled in the child's bedroom. Mus m 1, particulate matter smaller than 10 microns (PM 10 ), and particulate matter smaller than 2.5 microns were quantified in air samples, and Mus m 1 was quantified in settled dust samples. RESULTS: Mus m 1 was detected in settled dust samples from 100% of bedrooms. Airborne mouse allergen was detected in 48 of 57 (84%) bedrooms, and the median airborne mouse allergen concentration was 0.03 ng/m 3 . The median PM 10 concentration was 48 microg/m 3 . Airborne and settled dust mouse allergen levels were moderately correlated ( r = .52; P < .0001), and airborne Mus m 1 and PM 10 levels were weakly correlated ( r = .29; P = .03). Having cracks or holes in doors or walls, evidence of food remains in the kitchen, and mouse infestation were all independently associated with having detectable airborne mouse allergen. CONCLUSION: Airborne mouse allergen concentrations in many inner-city homes may be similar to those found in animal facilities, where levels are sufficiently high to elicit symptoms in sensitized individuals. Exposed food remains, cracks and holes in doors or walls, and evidence of mouse infestation appear to be risk factors for having detectable airborne Mus m 1.

Air Pollution, Indoor↗

Fly ash scrubbing in a novel dual flow scrubber.

Scrubbers are used as particulate emission control devices with the increase in stringency of old regulations or promulgation of new regulations. Scrubbing of fly ash in a novel dual flow scrubber, i.e., one water filled bubble section and one section with water-spray, is reported in this article. The presented system included a tapered section in order to achieve the bubble regime. On the other hand, a two-phase critical flow atomizer was used for the generation of spray regime with high degree of spray uniformity. Experiments were carried out for studying the behavior of the system in terms of various pertinent variables. The fly ash removal mechanism was explained in terms of various physical interactions. Electrostatic effect was found to have an insignificant influence on the collection efficiency of fly ash. The removal efficiency was found to decrease with the increase in inlet fly ash loading in the bubble section while it was increased in the spray section. A compromise must, therefore, be struck while operating the scrubber for achieving the desired performance. The effects of other operating variables studied on the removal efficiency remained similar in the regimes under investigation. The combined effect was, however, that the spray regime was dominating. Experimentation also revealed that the bubble section collected particles down to 20 microm size. Detailed experimentation revealed that almost 100% removal efficiency (zero penetration) of fly ash could be achieved in the dual flow scrubber at a QL/QG ratio of 3.0 m3/1000 ACM (actual cubic meter). Almost zero penetration of fly ash particles, clearly demonstrated that the dual flow scrubber with its staging operations met with the stricter emission regulations for particulate matter. Selection of any particulate control device is intrinsically related to the performance as a function of various pertinent variables of the system. Correlations were, therefore, put forward for the prediction of the performances of the bubble and the spray sections in terms of various pertinent variables of the system. The overall removal efficiency achievable in the dual flow scrubber was predicted with the help of these correlations. The predicted values were in excellent agreement with the experimental values (well within +/-5.0% deviation). Comparison of the performance of the present system with the existing systems indicated that the bubble and spray sections either alone or in combination (as in a dual flow scrubber), was energy and efficiency-wise much better than the existing systems. The novelty of the system is also described.

Air Pollution↗

Assessing exposure to diesel exhaust particles: a case study.

The assessment of the vehicular contributions to urban pollution levels is of particular importance given the current interest in the possible adverse health effects. This study focused on human exposure to diesel-engine-derived particulate matter. Diesel vehicles are known to emit fine particulate matter (PM2.5) containing carcinogens such as polycyclic aromatic hydrocarbons (PAHs), and have therefore received considerable attention. In this study, the physical (mass and number concentration, and size distribution) and chemical (PAHs) properties were investigated at a major bus interchange in Singapore, influenced only by diesel exhausts. Number concentration and size distribution of particles were determined in real time, while the mass concentrations of PM2.5, and PAHs were measured during operating and nonoperating hours. The average mass concentrations of PM2.5 and PAHs increased by a factor of 2.34 and 5.18, respectively, during operating hours. The average number concentration was also elevated by a factor of 5.07 during operating hours. This increase in the concentration of PM2.5 particles and their chemical constituents during operating hours was attributable to diesel emissions from in-use buses based on the particle size analysis, correlation among PAHs, and the commonly used PAHs diagnostic ratios. To evaluate the potential health threat due inhalation of air pollutants released from diesel engines, the incremental lifetime cancer risk was also calculated for a maximally exposed individual. The findings indicate that the air quality at the bus interchange poses adverse health effects.

Air Pollutants↗