PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polyesters”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Erosion kinetics of hydrolytically degradable polymers.

Degradable polymers are beginning to play an increasing role as materials for environmental and medical applications. Understanding factors that control erosion, such as bond cleavage and the dissolution and diffusion of degradation products, will be critical to the future development of these materials. Erosion kinetics, photomicroscopy, and infrared spectroscopy were used to understand the erosion mechanism of two families of degradable polymers, polyanhydrides and polyesters. Polyanhydrides exhibit behavior more characteristic of surface erosion, whereas the polyesters exhibit bulk erosion patterns. Control of erosion times from a few days to several years can be achieved by a judicious choice of monomer units and bond selection.

Anhydrides↗

Novel biodegradable aromatic plastics from a bacterial source. Genetic and biochemical studies on a route of the phenylacetyl-coa catabolon.

Novel biodegradable bacterial plastics, made up of units of 3-hydroxy-n-phenylalkanoic acids, are accumulated intracellularly by Pseudomonas putida U due to the existence in this bacterium of (i) an acyl-CoA synthetase (encoded by the fadD gene) that activates the aryl-precursors; (ii) a beta-oxidation pathway that affords 3-OH-aryl-CoAs, and (iii) a polymerization-depolymerization system (encoded in the pha locus) integrated by two polymerases (PhaC1 and PhaC2) and a depolymerase (PhaZ). The complete assimilation of these compounds requires two additional routes that specifically catabolize the phenylacetyl-CoA or the benzoyl-CoA generated from these polyesters through beta-oxidation. Genetic studies have allowed the cloning, sequencing, and disruption of the genes included in the pha locus (phaC1, phaC2, and phaZ) as well as those related to the biosynthesis of precursors (fadD) or to the catabolism of their derivatives (acuA, fadA, and paa genes). Additional experiments showed that the blockade of either fadD or phaC1 hindered the synthesis and accumulation of plastic polymers. Disruption of phaC2 reduced the quantity of stored polymers by two-thirds. The blockade of phaZ hampered the mobilization of the polymer and decreased its production. Mutations in the paa genes, encoding the phenylacetic acid catabolic enzymes, did not affect the synthesis or catabolism of polymers containing either 3-hydroxyaliphatic acids or 3-hydroxy-n-phenylalkanoic acids with an odd number of carbon atoms as monomers, whereas the production of polyesters containing units of 3-hydroxy-n-phenylalkanoic acids with an even number of carbon atoms was greatly reduced in these bacteria. Yield-improving studies revealed that mutants defective in the glyoxylic acid cycle (isocitrate lyase(-)) or in the beta-oxidation pathway (fadA), stored a higher amount of plastic polymers (1.4- and 2-fold, respectively), suggesting that genetic manipulation of these pathways could be useful for isolating overproducer strains. The analysis of the organization and function of the pha locus and its relationship with the core of the phenylacetyl-CoA catabolon is reported and discussed.

Acetyl Coenzyme A↗

Combined effects of fabric air permeability and moisture absorption on clothing microclimate and subjective sensation during intermittent exercise at 27 degrees C.

The present paper aimed at determining the combined effects of two different levels of air permeability and moisture absorption, in terms of clothing microclimate and subjective sensation, in resting and exercising subjects at an ambient temperature of 27 degrees C, a relative humidity of 50% and an air velocity of 0.14 m s-1. Three kinds of clothing ensemble were investigated: (1) polyester clothing with low moisture absorption and low air permeability (A), (2) polyester clothing with low moisture absorption and high air permeability (B), and (3) cotton clothing with high moisture absorption and high air permeability (C). The subjects exercised for 10 min on a cycle ergometer at an intensity of 30% maximal oxygen uptake and then had a 10 min rest. This sequence was repeated four times. The main findings are summarized as follows: (1) The clothing microclimate humidity in the back area was significantly higher in A than in B, and in C than in B. (2) The clothing microclimate temperature in the chest area was significantly higher in B than in A, and in B than in C. (3) The clothing microclimate temperature in the back area was significantly higher in C than in B. (4) The clothing surface temperature was significantly higher in C than in B. (5) Although the positive relationships between the microclimate humidity and forearm sweat rate was significantly confirmed in all three kinds of clothing, the microclimate humidity at chest for the same sweat rate was lower in C than in A and B. (6) Although the positive relationships between subjective sensation and forearm sweat rates were significantly confirmed in all three kinds of clothing, the subjective discomfort seemed to be reduced more effectively in C than in A and B for the same sweat rate. These results were discussed in terms of thermal physiology and combined effects of air permeability and moisture absorbency of the fabrics.

Absorption↗

Microencapsulation of superoxide dismutase into biodegradable microparticles by spray-drying.

The aim of this work was to encapsulate superoxide dismutase (SOD) into biodegradable microparticles by spray-drying technique. The nature of the organic solvent to dissolve the polymer, the method of incorporation of the drug in the organic phase (with or without a surfactant, namely sucrose ester of HLB = 6), the surfactant/polymer ratio, and the nature of the biodegradable polyesters were investigated as formulation variables. The polyesters investigated as matrix were poly(epsilon-caprolactone) (PCL), poly(d, l, lactide-co-glycolide) (PLG-RG756), and poly(d, l-lactide) (PLA-R207) of respective molecular weight 78.2 kDa, 84.8 kDa, and 199.8 kDa. At surfactant/polymer ratio of 1/10, the SOD-retained enzymatic activities were higher (> 95%) for PLG-RG756 and PLA-R207 but relatively lower for the PCL (approximately 85%) probably due to the PCL relatively higher hydrophobicity. The obtained microparticles exhibited average volume mean diameter of 4-10 microm, the smaller for PCL and the larger for PLG-RG756 polymeric matrix. The in vitro release profile showed that SOD was completely (100%) released from PLA-R207 in 48 hr and from PLG-RG756 and PCL within 72 hr. These results showed that spray-drying with incorporation of surfactant such as sucrose ester may efficiently encapsulate SOD into biodegradable microparticles. Such formulations may improve the bioavailability of SOD and similar biopharmaceuticals.

Algorithms↗

Filtration properties of nonwovens.

This paper presents the results and conclusions from experimental investigations concerning filtration properties of nonwovens. The needled nonwovens were made from polyester fibres (PTE) with average fibre diameter 12 micrometres and polypropylene fibres (PP) with average fibre diameter 32 micrometres. Nonwovens were produced out of each of those fibres or out of a mixture of polyester and polypropylene fibres. This paper also presents investigations of nonwoven fabric made of polypropylene fibres (PP) with average fibre diameter 2.6 micrometres, which was formed according to melt-blown technology. Oil mist, as challenge aerosol, was used to evaluate the performance of filter media at various aerosol velocities. The average oil mist test aerosol particle diameter was 0.3 micrometre. Filter penetration was measured at oil mist concentration 0.24 g/m(3).

Aerosols↗

Fabrication of a trileaflet heart valve scaffold from a polyhydroxyalkanoate biopolyester for use in tissue engineering.

Previously, we reported the implantation of a single tissue engineered leaflet in the posterior position of the pulmonary valve in a lamb model. The major problems with this leaflet replacement were the scaffold's inherent stiffness, thickness, and nonpliability. We have now created a scaffold for a trileaflet heart valve using a thermoplastic polyester. In this experiment, we show the suitability of this material in the production of a biodegradable, biocompatible scaffold for tissue engineered heart valves. A heart valve scaffold was constructed from a thermoplastic elastomer. The elastomer belongs to a class of biodegradable, biocompatible polyesters known as polyhydroxyalkanoates (PHAs) and is produced by fermentation (Metabolix Inc., Cambridge, MA). It was modified by a salt leaching technique to create a porous, three-dimensional structure, suitable for tissue engineering. The trileaflet heart valve scaffold consisted of a cylindrical stent (1 mm X 15 mm X 20 mm I.D.) containing three valve leaflets. The leaflets were formed from a single piece of PHA (0.3 mm thick), and were attached to the outside of the stent by thermal processing techniques, which required no suturing. After fabrication, the heart valve construct was allowed to crystallize (4 degrees C for 24 h), and salt particles were leached into doubly distilled water over a period of 5 days to yield pore sizes ranging from 80 to 200 microns. Ten heart valve scaffolds were fabricated and seeded with vascular cells from an ovine carotid artery. After 4 days of incubation, the constructs were examined by scanning electron microscopy. The heart valve scaffold was tested in a pulsatile flow bioreactor and it was noted that the leaflets opened and closed. Cells attached to the polymer and formed a confluent layer after incubation. One advantage of this material is the ability to mold a complete trileaflet heart valve scaffold without the need for suturing leaflets to the conduit. Second advantage is the use of only one polymer material (PHA) as opposed to hybridized polymer scaffolds. Furthermore, the mechanical properties of PHA, such as elasticity and mechanical strength, exceed those of the previously utilized material. This experiment shows that PHAs can be used to fabricate a three-dimensional, biodegradable heart valve scaffold.

Animals↗

Emulsifying performance of modular beta-sandwich proteins: the hydrophobic moment and conformational stability.

Our understanding of protein emulsifying properties is largely based on analysis of emulsifiers found in milk and seed. The 9th-10th type III fibronectin domain pair retains full biological activity following emulsification-encapsulation into polyester microspheres, for controlled delivery, but the conformational criteria determining emulsification efficiency (EE) are unknown. Here, we have generated a series of mutants of this beta-sandwich protein, changing the hydrophobic moment and conformational stability, to investigate the structure-emulsification relationship. Predictive modelling of the hydrophobic moment of beta-strands and mutations known to increase conformational stability were used to generate the series. The proteins were tested for their emulsion stability and EE for oil-in-water mixtures. We show that the stabilization of emulsions by beta-sandwich proteins is best predicted by conformational stability during equilibrium denaturation in ionic surfactant. In contrast, the EE of these proteins is inversely related to an increase in their surface hydrophobicity following unfolding in surfactant. We also describe a novel beta-sandwich emulsifier with strong EE. The requirement for interdomain flexibility to achieve maximum emulsion stability and EE is also shown. This work increases our understanding of the mechanisms involved in protein emulsification and will be of use to the microencapsulation of proteins into polyester microspheres via emulsion-extraction protocols.

Emulsions↗

Noninvasive follow-up of tissue encapsulation of foreign materials. Are magnetic resonance imaging and spectroscopy breakthroughs?

The development of sensitive and noninvasive magnetic resonance (MR) techniques for the long- and short-term evaluation of vascular prostheses requires detailed knowledge of the evolutionary trend of the MR properties of the perigraft tissue during the healing process. To characterize changes in water MR properties, the water proton relaxation times, T1 and T2, of the muscle in the vicinity of an implanted polyester material were measured as a function of implantation time. To provide better insight into interpretation of the MR results, we carried out histologic and peripheral blood cell activation studies and tissue water content measurements. The MR results illustrated the sensitivity of the relaxation times to changes in cellular response to the presence of an implant. The evolutionary trend of these MR parameters exhibited two distinct phases. The crossover from phase I to phase II occurred around 10 days postimplantation. This crossover is attributed to the transition in the inflammatory response from the acute phase to the chronic phase. During the acute phase, the very high initial T1 and T2s (the slower relaxing component of the transverse relaxation time) values decreased significantly and steadily. The value of T1 dropped by a factor of 2, whereas T2s went down by a factor of 6. During the same time, the diffusion parameter, beta, remained constant. However, during the chronic phase, the diffusion parameter increased sharply. By 30 days postimplantation, the value of beta had increased by a factor of 10. The relaxation times, on the other hand, increased steadily with implantation time. Because the current MR results provide an in vivo and noninvasive follow-up of the healing process around the polyester implant material, they will be of considerable value in the early detection of vascular graft complications by MR imaging.

Animals↗

Use of supercritical fluid extraction as a method of cleaning anterior cruciate ligament prostheses: in vitro and in vivo validation.

The process of supercritical fluid extraction (SFE) using carbon dioxide as the mobile phase is finding increasing numbers of applications in a wide variety of industries for the extraction, separation, and cleaning of materials. This study assessed the usefulness of this approach in removing surface contaminants from a knitted polyester anterior cruciate ligament (ACL) prosthesis before packaging and sterilizing the product during manufacture. The physical, dimensional, and chemical properties of SFE treated compared with commercially scoured control samples were characterized using a number of textile test methods: electron spectroscopy for chemical analysis, Fourier transform infrared spectroscopy, differential scanning calorimetry, and solvent extraction analysis. The biocompatibility of the samples was measured in terms of their ability to generate CD18 integrin expression on activated human polymorphonuclear cells, and their inflammatory response when implanted for up to 30 days in the knee joint of rats. SFE treatment was successful in removing most of the nonpolar contaminants from the ACL prosthesis and reducing the amount of residuals to a commercially acceptable level. However, some nitrogen containing compounds and polar salts were not removed by the SFE process. The results from the biocompatibility tests demonstrated that the cleaner SFE treated prosthesis induced significantly lower CD18 expression than the scoured control fabric, and was also associated with a milder inflammatory response and a more rapid rate of healing during the 30 day animal trial. Another effect of SFE processing was to cause the polyester device to shrink and lose porosity because of yarn contraction and modification of the polymer's microcrystalline structure.

Animals↗

Fast measurements of transmission of erythema effective irradiance through clothing fabrics.

For efficiently measuring ultraviolet transmission through clothing materials for a large number of samples, an automated measuring system with a broad-band method has been built and calibrated against a spectroradiometer based instrument. The apparatus can be used to test 60 samples in 25 min. A selection of clothing materials of known composition, weave, color and state have been tested, using the broad band method and the automated measuring system together with a solar ultraviolet simulator. Variations of about eleven times for different weave structure, about two times in the ultraviolet transmittance for different colors, and about 20 times for some stretched samples were observed. For wet conditions, an increment in ultraviolet transmittance for cotton and lycra materials and a decrement for polyester and polyester(65%)/cotton(35%) were also observed.

Clothing↗

Experience on endothelial cell adhesion on vascular stents and stent-grafts: first in vitro results.

RATIONALE AND OBJECTIVES: To evaluate endothelial cell (EC) attachment on different stents and stent-grafts combined with different coating materials. MATERIALS AND METHODS: Three segments (approximately 1cm(2) each) of Cragg-, Memotherm-, Palmaz-, Strecker-, and Wall-stents, uncovered or covered with polytetrafluoroethylene (PTFE), polyurethane (PU) or polyester (Dacron) were precoated with fibronectin and seeded in vitro under steady conditions with 2 x 10(5) human venous EC/cm(2) for 2 days. EC attachment and morphology was assessed by scanning electron microscopy. RESULTS: Superior EC attachment on uncovered stents was seen on Memotherm-, Palmaz-, and Wall-stent. On uncovered Cragg- and Strecker-stent only a few single and rounded EC could be detected. PTFE-covering lead to an equal or decreased EC coverage in comparison with the uncovered prostheses. An increase in EC coverage on PU-covered stents was seen and on polyester covered stents as compared with uncovered stents. CONCLUSION: In vitro, EC attachment is clearly different on vascular stents and stent-grafts, probably depending on the material of the stents stent and unknown manufacturing related components. When EC adhesion is desired and stent covering is used, the choice of covering material may influence EC adhesion.

Cell Adhesion↗

Acute thrombogenicity of arterial prostheses exposed to reduced blood flow in dogs: effects of heparin, aspirin, and prostacyclin.

Thrombogenesis is considered the principal cause of early failure of arterial grafts. Although antithrombotic drugs are recommended, their efficiency under low blood flow conditions is still being debated. In this study, we evaluated the ability of three drugs to modify the thrombotic properties of blood and, consequently, to influence platelet and fibrin deposition on the luminal surface of polyester arterial prostheses. In dogs receiving saline (control, n = 10), heparin (100 U/kg, n = 5), aspirin (325 mg, n = 5), or prostacyclin (15 ng/kg/min, n = 5), a 30-cm, woven, loop-shaped, DeBakey arterial prosthesis was implanted as a substitute for the infrarenal aorta and exposed to reduced blood flow (50 ml/min) for 4 h. The parameters of the blood measured included activated clotting time (ACT) and platelet aggregation with collagen, determined before and after each treatment. Blood deposits were quantified using 111In labeled platelets and 125I-labeled fibrinogen. The ACT was significantly prolonged only after heparin treatment, and platelet aggregation, which was decreased by 35% (p < 0.05) after heparin treatment, was almost abolished after aspirin and prostacyclin treatments. As compared with the control group, both platelet and fibrin uptake on the luminal surface of the prostheses were reduced significantly by heparin by 87 and 37%, respectively. Despite their inhibition of platelet aggregation in vitro, aspirin and prostacyclin induced no significant change in platelet and fibrin deposition on the luminal surface of the woven polyester arterial prostheses under low blood flow conditions. Under such conditions, however, thrombin generation with subsequent platelet-fibrin deposition was prevented by use of heparin anticoagulant therapy.

Administration, Oral↗

Covalent linking of proteins and cytokines to suture: enhancing the immune response of head and neck cancer patients.

BACKGROUND: The immune system of advanced stage head and neck cancer patients is frequently suppressed. Poor immune function has been correlated with poor clinical outcome. Immunotherapeutic strategies have been previously attempted in an effort to enhance immune function and improve survival. Previous studies have shown surgical suture can be transformed into an immune stimulant capable of activating the T lymphocytes of cancer patients. The development of a process for covalently linking proteins and cytokines to suture could have enormous potential for the in vivo manipulation of the immune system. HYPOTHESIS: We hypothesize proteins and cytokines can be covalently linked to surgical suture while preserving their functional properties. STUDY DESIGN: Prospective study testing normal donor and head and neck squamous cell carcinoma (HNSCC) patient lymphocytes. METHOD: Polyester suture was acid hydrolyzed followed by reacting with 1-ethyl-3(-3-dimethylamino propyl carbodiimide) (EDAC) to create a suture-EDAC intermediate. Next, selected proteins (horseradish peroxidase [HRP] or bovine serum albumin [BSA]) or cytokines (interleukin [IL]-2 or interferon [IFN]-gamma) were reacted with the suture-EDAC intermediate to test the covalent linkage of the selected protein or cytokine to suture. Functional activity of the linked proteins was measured spectrophotometrically. The linking of cytokines to suture was tested by stimulating normal donor peripheral blood lymphocytes (PBL) or HNSCC patients' lymphocytes. The functional activity was confirmed by proliferation, enzyme linked immunoadsorbent assay (ELISA), and phenotype expression of T cells. RESULTS The conditions for optimally linking a protein to polyester suture were defined using HRP as a model protein. HRP retained its enzymatic activity. The optimal conditions for linking IL-2 or IFN-gamma were defined. The covalently linked cytokines retained their immune enhancing properties for stimulating PBL and lymph node lymphocytes (LNL) from HNSCC patients to proliferate, generate a TH1 immunologic profile of cytokines (IL-2, IL-12, IFN-gamma), and stimulate T lymphocytes. CONCLUSION: This is the first report to demonstrate that cytokines can be covalently linked to surgical sutures and retain their immune-stimulating properties. Proteins linked to suture also retained their enzymatic activity. The clinical implications of functionally active cytokines or proteins linked to surgical suture may be very significant in the future for manipulating the immune system in vivo or enhancing wound healing.

Adult↗

Clothing fabric does not affect thermoregulation during exercise in moderate heat.

PURPOSE: We investigated whether temperature regulation is improved during exercise in moderate heat by the use of clothing constructed from fabric that was purported to promote sweat evaporation compared with traditional fabrics. METHODS: Eight well-trained, euhydrated males performed three exercise bouts wearing garments made from an evaporative polyester fabric (SYN), wearing garments made from traditional cotton fabric (COT), or dressed seminude (S-N) in random order. Bouts consisted of 15 min seated rest, 30 min running at 70% .VO(2max), 15 min walking at 40% .VO(2max), and 15 min seated rest, all at 30 +/- 1 degrees C and 35 +/- 5% relative humidity. COT and SYN clothing ensembles consisted of crew neck, short sleeve T-shirts, cycling shorts, and anklet socks made from their respective materials, and running shoes. The S-N condition consisted of a Lycra swim suit, polyester socks, and running shoes. RESULTS: Mean skin temperature was lower for S-N during preexercise rest when compared with SYN and COT. No differences in mean body temperature, rectal temperature, or mean skin temperature were observed during or after exercise. No differences in VO2 or heart rate were observed. No differences in comfort sensations were observed. CONCLUSION: In summary, before, during, or after exercise in a moderately warm environmental condition, neither the addition of a modest amount of clothing nor the fabric characteristics of this clothing alters physiological, thermoregulatory, or comfort sensation responses.

Adult↗

Differentiated growth of human renal tubule cells on thin-film and nanostructured materials.

Over 300,000 Americans are dependent on hemodialysis as treatment for renal failure, and kidney transplantation is limited by scarcity of donor organs. This shortage has prompted research into tissue engineering of renal replacement therapy. Existing bioartificial kidneys are large and their use labor intensive, but they have shown improved survival compared to conventional therapy in preclinical studies and an US Food and Drug Administration-approved phase 2 clinical trial. This hybrid technology will require miniaturization of hemofilters, cell culture substrates, sensors, and integration of control electronics. Using the same harvesting and isolation techniques used in preparing bioartificial kidneys for clinical use, we characterized human renal tubule cell growth on a variety of silicon and related thin-film material substrates commonly used in the construction of microelectromechanical systems (MEMS), as well as novel silicon nanopore membranes (SNMs). Human cortical tubular epithelial cells (HCTC) were seeded onto samples of single-crystal silicon, polycrystalline silicon, silicon dioxide, silicon nitride, SU-8 photoresist, SNMs, and polyester tissue culture inserts, and grown to confluence. The cells formed confluent monolayers with tight junctions and central cilia. Transepithelial resistances were similar between SNMs and polyester membranes. The differentiated growth of human tubular epithelial cells on MEMS materials strongly suggests that miniaturization of the existing bioartificial kidney will be feasible, paving the way for widespread application of this novel technology.

Biocompatible Materials↗

The fungal hydrophobin RolA recruits polyesterase and laterally moves on hydrophobic surfaces.

When fungi grow on plant or insect surfaces coated with wax polyesters that protect against pathogens, the fungi generally form aerial hyphae to contact the surfaces. Aerial structures such as hyphae and conidiophores are coated with hydrophobins, which are surface-active proteins involved in adhesion to hydrophobic surfaces. When the industrial fungus Aspergillus oryzae was cultivated in a liquid medium containing the biodegradable polyester polybutylene succinate-coadipate (PBSA), the rolA gene encoding hydrophobin RolA was highly transcribed. High levels of RolA and its localization on the cell surface in the presence of PBSA were confirmed by immunostaining. Under these conditions, A. oryzae simultaneously produced the cutinase CutL1, which hydrolyses PBSA. Pre-incubation of PBSA with RolA stimulated PBSA degradation by CutL1, suggesting that RolA bound to the PBSA surface was required for the stimulation. Immunostaining revealed that PBSA films coated with RolA specifically adsorbed CutL1. Quartz crystal microbalance analyses further demonstrated that RolA attached to a hydrophobic sensor chip specifically adsorbed CutL1. Circular dichroism spectra of soluble-state RolA and bound RolA suggested that RolA underwent a conformational change after its adsorption to hydrophobic surfaces. These results suggest that RolA adsorbed to the hydrophobic surface of PBSA recruits CutL1, resulting in condensation of CutL1 on the PBSA surface and consequent stimulation of PBSA hydrolysis. A fluorescence recovery after photobleaching experiment on PBSA films coated with FITC-labelled RolA suggested that RolA moves laterally on the film. We discuss the novel molecular functions of RolA with regard to plastic degradation.

Adipates↗

Comparison of five different filters for the removal of leukocytes from red cell concentrates.

The leukocyte depletion capacity and performance of 5 filters designed for filtration of red cell concentrates (RCC) were compared by counting leukocytes, measuring red cell volumes and by histological examination of the filters after use. To eliminate interdonor differences, 5 buffy-coat-poor RCC were pooled (in each of 10 experiments) and subsequently split up into the original bags. The RCC were passed over the Cellselect filter, a column filled with cellulose acetate, and over flat-bed polyester filters: the Cellselect Optima, the Pall RC 50, the Leukostop and the Sepacell R-500. The filtration was shortest with the Pall RC 50 (p less than 0.001 compared to the other 4 filters). Leukocyte removal was most effective with the cellulose acetate filter (p less than 0.01 compared to the other 4 filters) followed by the Cellselect Optima polyester filter (p less than 0.02 compared to the remaining 3 filters). Residual leukocytes did not exceed 50 x 10(6) for any brand of filter. Red cell recovery was similar for all 5 filters with mean values from 86.1 to 89.2%. The leukocyte numbers, counted in Türk's solution or in propidium iodide, gave comparable values in hemocytometers applying light microscopy or fluorescent microscopy, respectively. Histological examination showed that lymphocytes were mainly removed by trapping, whereas granulocytes showed a variable pattern: adhesion in presence of platelets or trapping.

Blood Component Removal↗

Evaluation of a filtration lymphocytapheresis (LCP) device for use in the treatment of patients with rheumatoid arthritis.

A practical on-line lymphocytapheresis (LCP) system using a leukapheresis filter (Cellsorba, Asahi Medical Co.) was evaluated in six patients with refractory rheumatoid arthritis. This filter consists of nonwoven fine polyester fiber wound around a porous cylinder. The blood was passed through the polyester fiber at a flow rate of 50 ml/min for 60 min. LCP was carried out once a week in the first month and biweekly in the next 2 months. An average of 98% of the leukocytes that entered the filter (1.27 x 10(10) cells) and 100% of the lymphocytes that entered the filter (3.66 x 10(9) cells) were removed in the first LCP. A total of 96.6% of the platelets and 2.7% of the erythrocytes that entered the filter were also removed. All of the patients showed clinical improvement in morning stiffness, Lansbury articular index, and functional capacity, with no adverse reaction. The number of circulating erythrocytes and platelets and the concentration of various serum components showed no significant change during the treatments. This LCP system required no fresh frozen plasma, albumin, or other blood transfusion. The number of circulating lymphocytes decreased to 65-70% of the pretreatment circulating lymphocyte count at the last procedure, with a decrease in the ratio of Leu3a positive cells to Leu2a positive cells. The proliferative response to phytohemagglutinin and concanavalin A was improved. These data suggest that LCP to remove approximately 3 x 10(9) lymphocytes once a week or biweekly has an immunomodulatory effect.

Arthritis, Rheumatoid↗