PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Reproducibility”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Improvement of reproducibility of macular volume measurements using the Heidelberg retinal tomograph.

AIMS: To develop a more reproducible method of macular volumetric analysis in order to facilitate serial monitoring of changes in retinal oedema with time. METHODS: The Heidelberg retinal tomography (HRT) machine was used to scan the macula of 20 normal subjects and 40 diabetics with macular oedema. The volume above reference plane (VARP) within a 2 mm diameter and 3 mm diameter circle was measured twice in each eye. The position of the circle to be measured was carefully defined relative to major retinal vessels. As a modification to the previously published technique, fluctuation of the height of the contour line relative to the focal plane of the eye is compensated for by an adjustment of the reference plane. The position of the circle was controlled relative to major retinal vessels using an acetate. The reproducibility of VARP measurement was assessed by three variables-the standard error of the difference on two isolated VARP measurements, the standard error of the difference between the average of three readings on two different occasions, as well as the coefficient of variation (COV). RESULTS: Both the 2 mm and 3 mm circles showed good reproducibility in VARP measurements. In normal subjects, the COV of VARP for 2 mm circles and 3 mm circles were 13% and 12% respectively. In patients with macular oedema, the COV of VARP for 2 mm circles and 3 mm circles were 9% and 11% respectively. CONCLUSION: The modification of VARP measurements between scans of the same eye has improved the COV from 31% to 9% in eyes with diabetic macular oedema.

Diabetic Retinopathy↗

Reproducibility of continuous 24 hour oesophageal pH monitoring in infants and children.

The reproducibility of 24 hour oesophageal pH monitoring was studied in 30 infants and children including the proportions of the investigation time with a pH less than 4 (reflux index), the number of episodes with a pH less than 4 or lasting longer than five minutes, and the duration of the longest episodes with a pH less than 4. Twenty four hour pH monitoring was performed using identical equipment on two consecutive days under similar conditions. Pearson correlation coefficients range from 0.88 to 0.98. The results obtained on two consecutive days were similar. The reflux index and the number of reflux episodes greater than five minutes were the most reproducible parameters. Despite the many patient related factors influencing pH data, the reproducibility of 24 hour pH monitoring data are satisfactory for routine clinical application.

Child↗

A reproducible grading scale for histological assessment of inflammation in ulcerative colitis.

BACKGROUND: Evaluation of histological activity in ulcerative colitis needs to be reproducible but has rarely been tested. This could be useful both clinically and in clinical trials. AIM: To develop reproducible criteria which are valid in the assessment of acute inflammation (activity) and chronicity, and to evaluate these features in an interobserver variability study. METHODS: A six grade classification system for inflammation was developed which could also be fine tuned within each grade. The grades were: 0, structural change only; 1, chronic inflammation; 2, lamina propria neutrophils; 3, neutrophils in epithelium; 4, crypt destruction; and 5, erosions or ulcers. Ninety nine haematoxylin-eosin sections from endoscopically inflamed and non-inflamed mucosa from patients with distal ulcerative colitis were assessed in two separate readings by three pathologists independently and without knowledge of the clinical status. Interobserver agreement was compared pairwise using kappa statistics. RESULTS: Initially, kappa values between the observers were 0.20, 0.42, and 0.26, which are too low to be of value. Following development of a semiquantitative pictorial scale for each criterion, kappa values improved to 0.62, 0.70, and 0.59. For activity defined by neutrophils between epithelial cells, kappa values were 0.903, 1.000, and 0.907. Complete agreement was reached in 64% of samples of endoscopically normal and in 66% of endoscopically inflamed tissue. Neutrophils in epithelium correlated with the presence of crypt destruction and ulceration. CONCLUSION: A histological activity system was developed for ulcerative colitis that showed good reproducibility and modest agreement with the endoscopic grading system which it complemented. It has potential value both clinically and in clinical trials.

Biopsy↗

Reproducibility of incremental maximal cycle ergometer testing in patients with restrictive lung disease.

BACKGROUND: Exercise testing has become an important tool in the diagnosis and treatment of restrictive lung disease. The reproducibility of variables measured during exercise testing was examined in subjects with stable restrictive lung disease. METHODS: Six subjects, who had never previously undergone exercise testing, each underwent three maximal incremental exercise studies on a bicycle ergometer conducted during a 28 day period. RESULTS: Data collected at rest, before exercise, were not significantly different during the three study days. Comparison of results at the end of the exercise tests from the three studies also revealed no evidence of a significant learning effect. Reproducibility of exercise performance by subjects was assessed by the coefficient of variation. The mean within subject coefficient of variation at the end of the exercise tests was 5.6% for work rate, 7.9% for exercise duration, and 9.5% for dyspnoea. The mean within subject coefficient of variation obtained at the end of the exercise tests was 5.3% for oxygen uptake (VO2), 2.5% for oxygen saturation (SaO2), 4.0% for heart rate (HR), 5.5% for minute ventilation (VE), 5.8% for respiratory frequency (f), and 4.6% for tidal volume (VT). The mean within subject coefficient of variation at 40% and 70% of maximal work rates for VO2 was 5.7% and 5.6% respectively, for SaO2 1.3% and 1.5%, for HR 4.8% and 4.0%, for VE 6.3% and 6.6%, for f 10.1% and 7.8%, and for VT 6.0% and 4.5%. CONCLUSIONS: Variables measured during clinical exercise testing in subjects with restrictive lung disease are highly reproducible. No significant learning effect was found on repeated testing in subjects who had never previously undergone exercise testing.

Adult↗

Maximal inspiratory pressure: does reproducibility indicate full effort?

BACKGROUND: Maximal inspiratory pressure (MIP) is often relied upon as an index of inspiratory muscle strength, and reproducibility of MIP taken to indicate maximal effort. This study was designed to determine whether reproducibility is a valid indicator of maximal effort. METHODS: Ten normal subjects were studied, all of whom were familiar with the MIP test but none was an experienced subject. They were told that the purpose was to measure how accurately they could generate 50% of their MIP. Each performed nine MIP efforts and nine submaximal efforts. Means and coefficients of variation of peak negative inspiratory pressure (Pmax) and the ranges of the best three efforts were calculated for each type. RESULTS: Mean (SE) Pmax averaged-93.8 (6.0) cm H2O for the maximal efforts and -60.6 (7.7) cm H2O for the submaximal trials, with coefficients of variation averaging 8.71 (1.75)% and 14.58 (2.63)%, respectively and the ranges averaging 6.5 (1.1)% and 13.4 (3.5)%, respectively. There was no clear separation between the coefficients of variation or ranges of maximal and submaximal efforts. In four cases the ranges of the best three submaximal efforts were less than 5 cm H2O and less than 5% -criteria that have been used to validate MIP results. These four subjects had lower ranges for submaximal than maximal efforts, even when expressed as percentages of the means. CONCLUSION: Reproducibility should not be relied upon to indicate a valid MIP test, especially for research purposes when relatively small changes in inspiratory muscle strength must be discriminated.

Female↗

Reproducibility of resting heart rate variability with short sampling periods.

The purpose of this study was to determine whether resting heart rate variability (HRV) is reproducible with short sampling measurement periods using an office-based personal computer measurement system. Eight healthy active women participated in ECG analyses on 2 days within 1 week under controlled environmental and physiological conditions. After they rested for 10 minutes, a 10-min ECG was recorded. HRV was determined from a 2.5- and 5-min sample period using both time domain variables (meanRR and SDNN) and frequency domain variables (LF, HF, LF:HF). Repeated measures ANOVA found no significant differences between Day 1 and Day 2 for either sampling period (p > or = 0.23). For both the 2.5- and 5-min sampling periods, the intraclass correlations between days for the time domain variables showed good reproducibility (R = 0.86-0.90). The reproducibility of the frequency domain variable was only average (R = 0.67-0.96), with the LF:HF ratio yielding the higher R values.

Adult↗

Lymphatic mapping in patients with breast carcinoma: reproducibility of lymphoscintigraphic results.

PURPOSE: To evaluate the reproducibility of lymphoscintigraphic results in assessment of the location and number of sentinel nodes in patients with breast cancer. MATERIALS AND METHODS: Twenty-five patients with breast cancer were prospectively enrolled in this study. Lymphoscintigraphy was performed after intratumoral injection of about 130 MBq of technetium 99m nanocolloid. Anterior and lateral images were obtained 20 minutes and 2 and 4 hours after injection. The following day, scintigraphy was repeated after a second injection of the radiolabeled colloid in an identical fashion and was preceded by acquisition of a starting image. Two observers evaluated the paired images independently, and count rates were calculated from the images. Correlation coefficient and Bland-Altman methods were used to analyze the paired count rates. RESULTS: At least one sentinel node was visualized at lymphoscintigraphy in all 25 patients. Drainage to the axilla was observed in 17 patients; drainage to the axilla and extraaxillary basins, in seven patients; and drainage exclusively to extraaxillary sentinel nodes, in one patient. The second scintigraphic study revealed the same drainage pattern in all 25 patients (reproducibility, 100%; 95% CI: 86%, 100%). The Pearson correlation coefficient of the paired count rates was 0.54 (P <.001). Count rates at repeat scintigraphy were 23%-417% of the count rates at first scintigraphy in 95% of cases. CONCLUSION: Results of lymphoscintigraphy for lymphatic mapping in breast cancer are highly reproducible for assessment of the number of sentinel nodes.

Adult↗

Reproducibility of functional MR imaging: preliminary results of prospective multi-institutional study performed by Biomedical Informatics Research Network.

PURPOSE: To prospectively investigate the factors--including subject, brain hemisphere, study site, field strength, imaging unit vendor, imaging run, and examination visit--affecting the reproducibility of functional magnetic resonance (MR) imaging activations based on a repeated sensory-motor (SM) task. MATERIALS AND METHODS: The institutional review boards of all participating sites approved this HIPAA-compliant study. All subjects gave informed consent. Functional MR imaging data were repeatedly acquired from five healthy men aged 20-29 years who performed the same SM task at 10 sites. Five 1.5-T MR imaging units, four 3.0-T units, and one 4.0-T unit were used. The subjects performed bilateral finger tapping on button boxes with a 3-Hz audio cue and a reversing checkerboard. In a block design, 15-second epochs of alternating baseline and tasks yielded 85 acquisitions per run. Functional MR images were acquired with block-design echo-planar or spiral gradient-echo sequences. Brain activation maps standardized in a unit-sphere for the left and right hemispheres of each subject were constructed. Areas under the receiver operating characteristic curve, intraclass correlation coefficients, multiple regression analysis, and paired Student t tests were used for statistical analyses. RESULTS: Significant factors were subject (P < .005), k-space (P < .005), and field strength (P = .02) for sensitivity and subject (P = .03) and k-space (P = .05) for specificity. At 1.5-T MR imaging, mean sensitivities ranged from 7% to 32% and mean specificities were higher than 99%. At 3.0 T, mean sensitivities and specificities ranged from 42% to 85% and from 96% to 99%, respectively. At 4.0 T, mean sensitivities and specificities ranged from 41% to 73% and from 95% to 99%, respectively. Mean areas under the receiver operating characteristic curve (+/- their standard errors) were 0.77 +/- 0.05 at 1.5 T, 0.90 +/- 0.09 at 3.0 T, and 0.95 +/- 0.02 at 4.0 T, with significant differences between the 1.5- and 3.0-T examinations and between the 1.5- and 4.0-T examinations (P < .01 for both comparisons). Intraclass correlation coefficients ranged from 0.49 to 0.71. CONCLUSION: MR imaging at 3.0- and 4.0-T yielded higher reproducibility across sites and significantly better results than 1.5-T imaging. The effects of subject, k-space, and field strength on examination reproducibility were significant.

Adult↗

Normal left ventricular dimensions and function: interstudy reproducibility of measurements with cine MR imaging.

The authors evaluated the reproducibility of measurements of ventricular dimensions obtained with cine magnetic resonance (MR) imaging performed on two occasions in 11 healthy subjects. Two reviewers analyzed the studies in a blinded fashion to determine interobserver and interstudy variability of measurements of left ventricular (LV) mass, volume, ejection fraction, and systolic wall stress. LV mass showed good reproducibility between studies, with 3.6% and 3.8% variability for LV end-systolic mass for the two observers. LV end-diastolic volume varied by 5.2% and 3.9%, and LV end-systolic volume, by 9.7% and 0.9%. Variability for LV ejection fraction was 5.0% and 4.9%. The largest interstudy variability was end-systolic wall stress, 11.1% and 13.5%, which was due mostly to changes in arterial pressure between the two studies. It is concluded that anatomic and functional measurements from cine MR images are reproducible between studies. The small interstudy variability is likely related to the fact the measurements are derived directly from cine MR images that encompass the entire heart rather than depend on measurements of only sample images and the use of geometric models.

Adult↗

Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging.

The interstudy reproducibility of velocity-encoded cine (VEC) magnetic resonance (MR) imaging for quantification of regurgitant volume (RV) and regurgitant fraction (RF) was studied in 10 patients with chronic aortic regurgitation. Each patient underwent two VEC MR imaging studies. RV and RF were measured on the aortic flow curve by quantifying antegrade and retrograde flow per cardiac cycle. VEC MR imaging measurements for RV and RF correlated closely with volumetric measurements for both studies (r greater than .97). Interstudy reproducibility for VEC MR imaging measurement of RV and RF was high (r greater than .97), and the interstudy variability for VEC MR imaging measurements was low. These results demonstrate a high accuracy of VEC MR imaging for measurement of RV and RF in patients with chronic aortic regurgitation. The level of interstudy reproducibility of VEC MR imaging for quantitative assessment of RV and RF indicates the potential of this technique for follow-up and monitoring of response to therapy.

Adult↗

Coronary artery disease: improved reproducibility of calcium scoring with an electron-beam CT volumetric method.

PURPOSE: To assess the variability and reproducibility of a volumetric calcium score calculated with electron-bean computed tomographic (CT) scans of coronary arteries. MATERIALS AND METHODS: Two sets of electron-beam CT scans were obtained in patients with coronary calcification (group A) or known risk factors for coronary arterial disease (group B). The second set or scans was obtained after a brief interval (group A, n = 52) or after 1 year with no risk modification (group B, n = 27). Traditional (plaque area and attenuation) and volumetric calcium scores were calculated for each patient and lesion. RESULTS: The median percentage change for individual lesions in group A was 13% for the volumetric and 19% for the traditional score. The overall reduction in error with the volumetric score was 40% (P < .001). The median percentage change for group A patient totals was 9% for the volumetric and 15% for the traditional score (P < .001). In group B patients, the median volumetric score increased by 44% after 1 year. CONCLUSION: The volumetric score showed better reproducibility than the traditional score, and its variability was considerably less than the score increase in untreated patients after 1 year. The reproducibility of the volumetric method makes it useful for assessing the progression of coronary arterial disease on serial electron-beam CT studies.

Calcinosis↗

Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: feasibility, reproducibility, and technical quality.

PURPOSE: To evaluate the feasibility, reproducibility, and technical quality of a dynamic contrast material-enhanced isotropic three-dimensional (3D) volumetric interpolated breath-hold hepatic magnetic resonance (MR) imaging examination. MATERIALS AND METHODS: Fifty patients underwent 3D spoiled gradient-echo imaging (4.2/1.8 [repetition time msec/echo time msec]; flip angle, 12 degrees; interpolation in three directions; intermittent fat saturation; pixel size </= 2.5 mm in all dimensions) before and dynamically after administration of gadopentetate dimeglumine, with the first enhanced acquisition timed for hepatic arterial dominance by using a test bolus of contrast material. Qualitative and quantitative measures of image quality were determined. Patterns of arterial and venous anatomy were assessed. Ten patients (20%) underwent repeat imaging within 6 months, and reproducibility was evaluated. RESULTS: Hepatic contrast-to-noise ratios for nonenhanced and arterial, portal venous, and equilibrium phase studies averaged 13.0 +/- 12.6 (SD), 17.4 +/- 11.8, 30.4 +/- 16.2, and 28.6 +/- 21.1, respectively. During arterial phase, the liver enhanced a mean of 29% of the maximal enhancement as measured during portal venous phase. Hepatic vascular anatomic variants were comparable in distribution to those cited in published articles. Repeat studies were not significantly different in image quality when compared with original studies. CONCLUSION: High-quality arterial phase 3D volumetric interpolated breath-hold images can be obtained reliably and reproducibly when timed by using a test dose of contrast material.

Adipose Tissue↗

Reproducibility of osmotic and nonosmotic tests of vasopressin secretion in men.

We have studied the reproducibility of the thirst and arginine vasopressin (AVP) responses to osmotic and hypoglycemic stimulation in healthy volunteers undergoing repeat hypertonic (855 mmol/l) saline infusion and insulin tolerance tests (ITTs). Hypertonic saline infusion caused similar mean rises in plasma osmolality, AVP, and thirst on each occasion. Linear-regression analysis defined close relationships between the slopes (r = +0.72, P less than 0.05) and the abscissal intercepts (r = +0.89, P less than 0.001) of the regression lines relating plasma osmolality (Posmol) and plasma AVP (PAVP), and the group intraindividual component of the variance for the slopes and intercepts was 7 and 0.6%, respectively. There were close correlations between the slopes (r = +0.79, P less than 0.02) and the intercepts (r = +0.84, P less than 0.01) of the regression lines relating Posmol and thirst, and group intraindividual component of the variance was 14 and 0.7%, respectively. Hypertonic saline infusion was infused on four occasions in four subjects, and the results showed that the linear regression lines relating PAVP and Posmol and thirst and Posmol were reproducible within an individual. There were similar falls in blood glucose and elevations in PAVP in both ITTs. No relationship was defined between the fall in blood glucose and either the rise in PAVP or the area under the AVP curve (AUC). The intraindividual component of the variance for the rise in AVP and the AUC was 77 and 22.5%, respectively. The AVP and thirst responses to osmotic stimulation are highly reproducible, but there is considerable intraindividual variation in the AVP response to hypoglycemia.

Adult↗

Reproducibility and responsiveness of a noninvasive EMG technique of the respiratory muscles in COPD patients and in healthy subjects.

In the present study, we assessed the reproducibility and responsiveness of transcutaneous electromyography (EMG) of the respiratory muscles in patients with chronic obstructive pulmonary disease (COPD) and healthy subjects during breathing against an inspiratory load. In seven healthy subjects and seven COPD patients, EMG signals of the frontal and dorsal diaphragm, intercostal muscles, abdominal muscles, and scalene muscles were derived on 2 different days, both during breathing at rest and during breathing through an inspiratory threshold device of 7, 14, and 21 cm H2O. For analysis, we used the logarithm of the ratio of the inspiratory activity during the subsequent loads and the activity at baseline [log EMG activity ratio (EMGAR)]. Reproducibility of the EMG was assessed by comparing the log EMGAR values measured at test days 1 and 2 in both groups. Responsiveness (sensitivity to change) of the EMG was assessed by comparing the log EMGAR values of the COPD patients to those of the healthy subjects at each load. During days 1 and 2, log EMGAR values of the diaphragm and the intercostal muscles correlated significantly. For the scalene muscles, significant correlations were found for the COPD patients. Although inspiratory muscle activity increased significantly during the subsequent loads in all participants, the COPD patients displayed a significantly greater increase in intercostal and left scalene muscle activity compared with the healthy subjects. In conclusion, the present study showed that the EMG technique is a reproducible and sensitive technique to assess breathing patterns in COPD patients and healthy subjects.

Aged↗

Image analysis based grading of bladder carcinoma. Comparison of object, texture and graph based methods and their reproducibility.

The possibility that computerized image analysis could increase the reproducibility of grading of bladder carcinoma as compared to conventional subjective grading made by pathologists was investigated. Object, texture and graph based analysis were carried out from Feulgen stained histological tissue sections. The object based features were extracted from gray scale images, binary images obtained by thresholding the nuclei and several other images derived through image processing operations. The textural features were based on the spatial gray-tone co-occurrence probability matrices and the graph based features were extracted from the minimum spanning trees connecting all nuclei. The large numbers of extracted features were evaluated in relation to subjective grading and to factors related to prognosis using multivariate statistical methods and multilayer backpropagation neural networks. All the methods were originally developed and tested on material from one patient and then tested for reproducibility on entirely different patient material. The results indicate reasonably good reproducibility for the best sets of features. In addition, image analysis based grading showed almost identical correlation to mitotic density and expression of p53 protein as subjective grading. It should thus be possible to use this kind of image analysis as a prognostic tool for bladder carcinoma.

Humans↗

The reproducibility of nuclear morphometric measurements in invasive breast carcinoma.

The intraobserver and interobserver reproducibility of computerized nuclear morphometry was determined in repeated measurements of 212 samples of invasive breast cancer. The influence of biological variation and the selection of the measurement area was also tested. Morphometrically determined mean nuclear profile area (Pearson's r 0.89, grading efficiency (GE) 0.95) and standard deviation (SD) of nuclear profile area (Pearson's r 0.84, GE 0.89) showed high reproducibility. In this respect, nuclear morphometry equals with other established methods of quantitative pathology and exceeds the results of subjective grading of nuclear atypia in invasive breast cancer. A training period of eight days was sufficient to produce clear improvement in consistency of nuclear morphometry results. By estimating the sources of variation it could be shown that the variation associated with the measurement procedure itself is small. Instead, sample associated variation is responsible for the majority of variation in the measurements (82.9% in mean nuclear profile area and 65.9% in SD of nuclear profile area). This study points out that when standardized methods are applied computerized morphometry is a reproducible and reliable method of assessing nuclear atypia in invasive breast cancer. For further improvement special emphasize should be put on sampling rules of selecting the microscope fields and measurement areas.

Breast Neoplasms↗

The importance of cytologic intrarater and interrater reproducibility: the case of ductal lavage.

The reproducibility of a test result is a critical component of its clinical utility. Little information is available concerning the intrarater reproducibility of cytologic assessments. This study evaluated the reproducibility of cytologic interpretation of epithelial cells obtained from ductal lavage (DL), a minimally invasive method used to obtain sample cells from breast tissue. Two cytospin slides were made for each duct sampled. Slides with <10 cells were considered inadequate to make a diagnosis; the remaining slides were classified into mildly atypical, markedly atypical, and malignant cells. Each pair of slides were classified by the more serious diagnosis. DL samples from 100 ducts were independently blind-reviewed by two experienced cytopathologists. All abnormal slides and a random sample of normal slides and slides identified as inadequate for diagnosis (n = 43) were re-reviewed. The kappa for intrarater agreement was 0.59 +/- 0.10 for cytopathologist 1 and 0.33 +/- 0.08 for cytopathologist 2. The kappa for interrater agreement of slides from 100 ducts was 0.46 +/- 0.07. The interrater agreement of the slides that were re-reviewed was kappa = 0.27 +/- 0.09. Fair to moderate intrarater and interrater agreement of DL cytology was observed. Low intrarater and interrater cytologic consistency may compromise the interpretation of clinical studies of DL.

Breast Neoplasms↗

2-[11C]thymidine positron emission tomography reproducibility in humans.

PURPOSE: To evaluate the reproducibility of 2-[11C]thymidine positron emission tomography (PET) scanning in patients with advanced intra-abdominal malignancies. PATIENTS AND METHODS: The reproducibility of 2-[11C]thymidine PET was studied by comparing interpatient and intrapatient variability (coefficient of variability, COV) of both blood and tissue data. Arterial plasma metabolite levels were measured using on-line sampling and high-pressure liquid chromatography. 2-[11C]Thymidine retention in tissue was measured as the standardized uptake value at the end of the scan (SUV(end)), the area under the time-activity curve (AUC(0-1 hour)), and the fractional retention of thymidine (FRT). A group of seven patients were scanned 1 week apart with no intervening anticancer therapy. RESULTS: There was interpatient variability in the levels of 2-[11C]thymidine and its main metabolite, 11CO2, in plasma. Variability in 2-[11C]thymidine PET data was greater between (COV: SUV(end) = 38%, AUC(0-1 hour) = 32%, FRT = 47%) than within (COV: SUV(end) = 8%, AUC(0-1 hour) = 2%, FRT = 9%) patients. There was a borderline significant difference between the paired tumor data for SUV(end) (P = 0.041), but not for AUC(0-1 hour) (P = 0.81) or FRT (P = 0.90). There was a good correlation between paired data for SUV(end) (r = 0.98), AUC(0-1 hour) (r = 0.99), and FRT (r = 0.95). CONCLUSIONS: This is the first report showing that 2-[11C]thymidine PET scanning is reproducible in humans. Repeat scanning of tumor proliferation using 2-[11C]thymidine PET is feasible to perform in human intra-abdominal malignancies and should aid the future rapid assessment of antiproliferative tumor agents.

Abdominal Neoplasms↗