PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Detection of the cyclic nitramine explosives hexahydro-1,3,5-trinitro- 1,3,5-triazine (RDX) and octahydro- 1,3,5,7-tetranitro- 1,3,5,7-tetrazine (HMX) and their degradation products in soil environments.

The cyclic nitramine explosives hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX) were examined in field and microcosm soil samples to determine their patterns of degradation and environmental fates. A number of analytical techniques, including solid-phase microextraction with on-fiber derivatization, gas chromatography-mass spectrometry, gas chromatography with electron-capture detection, liquid chromatography-mass spectrometry, and micellar electrokinetic chromatography were required for the analyses. Two different classes of intermediates were detected, both of which lead ultimately to the formation of nitrous oxide (N2O) and carbon dioxide (CO2). The first class was identified as the nitroso derivatives formed by the sequential reduction of -NO2 functional groups. The second class of intermediates, which was favored at higher humidities and in the presence of anaerobic sludge amendments, consisted of ring cleavage products including bis-(hydroxymethyl)-nitramine and methylenedinitramine. Rye-grass (Lolium perenne) present in field samples was found to extract and accumulate HMX from soil without further degradation. In all cases (excepting the plant samples), the indigenous microbes or amended domestic anaerobic sludge consortia degraded the cyclic nitramine explosives eventually to produce N2O and CO2.

Azocines↗

Fast determination of phenols in contaminated soils.

An extraction method for the determination of phenols in contaminated soils, based on the application of solid-phase microextraction (SPME) coupled with GC-flame ionization detection analysis, was developed and tested. This method was developed using a natural soil spiked with phenol to a concentration level typical of an acute contamination event that can occur in an industrial site. The effects of the extraction parameters (pH, extraction time and salt concentration) on the extraction efficiency were studied and the method was then applied to determine the pollutant concentration at the beginning and during the biological treatment of a soil, contaminated with phenol and 3-chlorophenol, respectively. The SPME results were validated by comparison with those obtained with an US Environmental Protection Agency certified extraction method. The SPME method was also successfully applied to the determination of the adsorption behavior of 3-chlorophenol on a natural clay soil and was shown to be suitable for different matrices and phenolic compounds. Application of SPME technique results in a sharp reduction of the extraction times with negligible solvent consumption.

Chromatography, Gas↗

Hydrophobic interaction electrokinetic chromatography for the separation of polycyclic aromatic hydrocarbons using non-aqueous matrices.

Capillary electrophoresis methodology is developed to provide a rapid, inexpensive and robust technique for screening polycyclic aromatic hydrocarbons (PAHs) in water using additive complexation. A series of conventional RPLC ion-pairing agents are investigated in three different totally non-aqueous separation solvents, and the relative role of hydrophobic interaction versus electrostatic association is evaluated. Methanol is found to provide optimal selectivity when coupled with the tetrahexylammonium cation providing total analysis times of approximately 15 min for the analysis of thirteen 2-7-ring PAH pollutants. Solid-phase microextraction is demonstrated to be an effective sample preparation technique for extraction/preconcentration of PAHs from water into methanol run buffer prior to injection.

Chromatography, Micellar Electrokinetic Capillary↗

Time-weighted average sampling of airborne n-valeraldehyde by a solid-phase microextration device.

A solid-phase microextraction (SPME) device was used as a time-weighted average sampler for n-valeraldehyde. The SPME device was first modified to improve the wearer's acceptance as a passive sampler. Then a poly(dimethylsiloxane)-divinylbenzene fiber was used and O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) was loaded onto the fiber. Vapors of known concentrations around the threshold limit values time-weighted average of n-valeraldehyde and specific relative humidities (RHs) were generated by syringe pumps in a dynamic generation system. n-Valeraldehyde vapors in gas bags were also generated. An exposure chamber was designed to allow measurement of face velocities, temperatures, exposing vapor concentrations, and RHs. Gas chromatography with flame ionization detection was used for sample analysis. The appropriate adsorption time for SPME coating PFBHA was determined to be 2 min and the desorption time for oxime formed after sampling was optimized to be 2 min. The experimental sampling constant was found to be (3.86+/-0.13) x 10(-2) cm3/min and face velocity was not expect to have effect on the sampler.

Air↗

Automated headspace solid-phase dynamic extraction for the determination of amphetamines and synthetic designer drugs in hair samples.

The technique of automated headspace solid-phase dynamic extraction (SPDE) coupled with gas chromatography-mass spectrometry was evaluated for the determination of amphetamines and synthetic designer drugs in hair samples. Headspace SPDE is a novel method for the solventless extraction of organic compounds in aqueous samples. In a so-called inside needle capillary absorption trap a hollow needle with an internal coating of polydimethylsiloxane is used as extraction and preconcentration medium. Sampling is performed on the solution headspace by passing the gas through the device actively by a syringe. Analytes present in the sample are sorbed onto the deposited stationary phase. The syringe needle is placed into the injection port of a GC and rapid heating of the metal needle induces the desorption of analytes. For the determination of amphetamine, methamphetamine, 3,4-methylendioxyamphetamine (MDA), 3,4-methylendioxymethamphetamine, 3,4-methylendioxyethylamphetamine (MDEA), 3,4-methylendioxyphenyl-2-butanamine and N-methyl-1-(3,4-methylendioxyphenyl)-2-butanamine in human hair samples, 10 mg of hair were hydrolysed with sodium hydroxide. After absorption of analytes for an on-coating derivatization procedure the SPDE needle was directly placed into the headspace of a second vial containing N-methyl-bis(trifluoroacetamide). A validation procedure revealed absolute analyte recoveries between 10.2 and 16.7%. Linearity was obtained from 0.1 to 20 ng/mg with coefficients of correlation between 0.992 and 0.999. Intra- and inter-day precision were determined at two different concentrations and resulted in ranges between 1.4 and 4.1% (intra-day) and 4.2-14.6% (inter-day). Limits of detection between 0.03 ng/mg (MDA) and 0.19 ng/mg (MDEA) were achieved. Results indicated that SPDE is a rapid and sensitive method for the analysis of biological samples. Compared to solid-phase microextraction we found a higher extraction rate coupled with a faster automated operation.

Amphetamines↗

Detection of explosives and their degradation products in soil environments.

Polynitro organic explosives [hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and 2,4,6-trinitrotoluene (TNT)] are typical labile environmental pollutants that can biotransform with soil indigenous microorganisms, photodegrade by sunlight and migrate through subsurface soil to cause groundwater contamination. To be able to determine the type and concentration of explosives and their (bio)transformation products in different soil environments, a comprehensive analytical methodology of sample preparation, separation and detection is thus required. The present paper describes the use of supercritical carbon dioxide (SC-CO2), acetonitrile (MeCN) (US Environmental Protection Agency Method 8330) and solid-phase microextraction (SPME) for the extraction of explosives and their degradation products from various water, soil and plant tissue samples for subsequent analysis by either HPLC-UV, capillary electrophoresis (CE-UV) or GC-MS. Contaminated surface and subsurface soil and groundwater were collected from either a TNT manufacturing facility or an anti-tank firing range. Plant tissue samples were taken fromplants grown in anti-tank firing range soil in a greenhouse experiment. All tested soil and groundwater samples from the former TNT manufacturing plant were found to contain TNT and some of its amino reduced and partially denitrated products. Their concentrations as determined by SPME-GC-MS and LC-UV depended on the location of sampling at the site. In the case of plant tissues, SC-CO2 extraction followed by CE-UV analysis showed only the presence of HMX. The concentrations of HMX (<200 mg/kg) as determined by supercritical fluid extraction (SC-CO2)-CE-UV were comparable to those obtained by MeCN extraction, although the latter technique was found to be more efficient at higher concentrations (>300 mg/kg). Modifiers such as MeCN and water enhanced the SC-CO2 extractability of HMX from plant tissues.

Azocines↗

Comparison of three different poly(dimethylsiloxane)-divinylbenzene fibres for the analysis of pesticide multiresidues in water samples: structure and efficiency.

Despite the continuing development of SPME (solid-phase microextraction) fibre coatings, their selection presents some difficulties for analysts in choosing the appropriate fibre for a certain application. There are two distinct types of SPME coatings available commercially. The most widely used are poly(dimethylsiloxane) (PDMS) and poly(acrylate) (PA). Supelco has developed new mixed phases consisting of porous polymer particles, either poly(divinylbenzene) (DVB) or Carboxen suspended in a matrix of PDMS or Carbowax for extracting analytes via adsorption. In addition to the nature of the extracting phase, the thickness of the polymeric film must be taken into account and, surprisingly, the construction of the fibres when apparently they bear the same coating, as it is the case of the three PDMS-DVB fibres available. Other fibre structure properties not well explored were identified and must be taken into consideration. To elucidate their extraction efficiency, three PDMS-DVB fibres, namely 60 microm for HPLC use, 65 microm for GC use and 65 microm StableFlex for GC use, were compared with regard to the extraction of 36 compounds included in four pesticide groups. The first was particularly suited for the extraction of organophosphorus pesticides and triazines whereas the StableFlex exhibited advantages in the analysis of organochlorine pesticides and pyrethroids. An explanation for the extraction differences is suggested based on the different structure of the fibres. Detection limits in the range of 1-10 ng/l for organochlorine pesticides, 1-30 ng/l for organophosphorus pesticides, 8-50 ng/l for triazines and 10-20 ng/l for pyrethroids were attained in a method using the 60 microm PDMS-DVB fibre. The fibre maintains its performance at well above 100 extractions with between-day precision below 10%.

Chromatography, Gas↗

Characterization and source identification of hydrocarbons in water samples using multiple analytical techniques.

This paper describes a case study in which multiple analytical techniques were used to identify and characterize trace petroleum-related hydrocarbons and other volatile organic compounds in groundwater samples collected in a bedrock aquifer exploited for drinking water purposes. The objective of the study was to confirm the presence of gasoline and other petroleum products or other volatile organic pollutants in those samples in order to assess the respective implication of each of the potentially responsible parties to the contamination of the aquifer. In addition, the degree of contamination at different depths in the aquifer was also of interest. The analytical techniques used for analyses of water samples included gas chromatography-mass spectrometry (GC-MS) and capillary GC with flame-ionization detection, solid-phase microextraction and headspace GC-MS techniques. Chemical characterization results revealed the following: (1) The hydrocarbons in sample A (near-surface groundwater, 0-5 m) were clearly of two types, one being gasoline and the other a heavy petroleum product. The significant distribution of five target petroleum-characteristic alkylkated polycyclic aromatic hydrocarbon homologues and biomarkers confirmed the presence of another heavy petroleum product. The concentrations of the TPHs (total petroleum hydrocarbons) and BTEX (collective name of benzene, toluene, ethylbenzene, and p-, m-, and o-xylenes) were determined to be 1070 and 155 microg/kg of water for sample A, respectively. (2) The deepest groundwater (sample B, collected at a depth ranging between 15 and 60 m) was also contaminated, but to a much lesser degree. The concentrations of the TPH and BTEX were determined to be only 130 and 2.6 microg/kg of water for sample B, respectively. (3) The presence of a variety of volatile chlorinated compounds to the groundwater was also clearly identified.

Chromatography, Gas↗

Comparison of different extraction methods for the analysis of fragrances from Lavandula species by gas chromatography-mass spectrometry.

Various sampling techniques including solid-phase trapping solvent extraction (SPTE), headspace solid-phase microextraction (HS-SPME), reduced pressure steam distillation (RPSD) and simultaneous steam distillation-solvent extraction (SDE) were compared for the gas chromatography-mass spectrometry of the fragrances from the Lavandula species. Linalyl acetate (35.44%) and linalool (18.70%) were predominant components of Hidcote lavender samples obtained by SPTE whereas those levels were 2.63-4.04 and 36.80-43.47% in the same samples by RPSD and SDE, respectively. The partition coefficients between the headspace gaseous phase and HS-SPME fiber, and the relative concentration factors of the four characteristic components of the lavender were measured for relative evaluation of the fiber efficiency. Five different coatings were evaluated and 100-microm poly(dimethylsiloxane) was the most efficient for the successful extraction of lavender fragrances. A total of 43 compounds were identified by SPTE and gas chromatography-mass spectrometry from four Lavandula species. Lavandula angustifolia Hidcote species, which contains a higher level of linalyl acetate and linalool but little camphor, was evaluated as the highest quality among the four different Lavandula species.

Gas Chromatography-Mass Spectrometry↗

Determination of siloxane-water partition coefficients by capillary extraction-high-resolution gas chromatography study of aromatic solvents.

Partition coefficients of benzene, toluene, ethylbenzene and xylenes (BTEX), between crosslinked polydimethylsiloxane and water, were determined at room temperature by capillary extraction (a form of in-tube solid-phase microextraction, SPME) coupled to open tubular gas chromatography (in-tube SPME-high-resolution GC). A series of 7-9 repetitive extractions, performed on a 1-ml volume of diluted aqueous BTEX sample by the double-syringe squeeze method, gave exponential regression curves which fit very well with those predicted by partition theory. From the equations of the curves of relative FID response vs. extraction number, experimental Kd were easily calculated and the results compared with literature values. The whole measurement requires about 1 h from the start of the experiment to the final calculation of all BTEX partition coefficients. In-tube SPME resulted in a fast, clean, efficient, and cheaper alternative than the classic 1-cm, externally coated, SPME fiber-holder technique.

Chromatography, Gas↗

Determination of the disproportionation products of limonene used for the catalytic hydrogenation of castor oil.

The direct determination by GC-MS analysis of the products from the limonene disproportionation obtained from the catalytic hydrogenation of castor oil is not possible since a transesterification of the oil is required before injection. Therefore, a method for the determination of those products is proposed here: a solid-phase microextraction (SPME) followed by GC-MS. With the optimization of SPME it was possible to isolate a great number of products of the disproportionation of limonene used as hydrogen donor in the catalytic hydrogenation of castor oil by Pd/C. This system also proved to be appropriate to monitor castor oil hydrogenation by following and identifying the limonene disproportionated products.

Castor Oil↗

Before the injection--modern methods of sample preparation for separation techniques.

The importance of sample preparation methods as the first stage in an analytical procedure is emphasised and examined. Examples are given of the extraction and concentration of analytes from solid, liquid and gas phase matrices, including solvent phase extractions, such as supercritical fluids and superheated water extraction, solid-phase extraction and solid-phase microextraction, headspace analysis and vapour trapping. The potential role of selective extraction methods, including molecular imprinted phases and affinity columns, are considered. For problem samples alternative approaches, such as derivatisation are discussed, and potential new approaches minimising sample preparation are noted.

Chromatography↗

Patterns in the precision of quantitative data from multicomponent gas chromatographic or gas chromatographic-mass spectrometric analysis.

The dispersion of the quantitative results in the analysis of volatile compounds from multicomponent mixtures by different fractionation techniques (solid-phase microextraction and direct thermal desorption) followed by GC or GC-MS presents nonrandom patterns related to the existence of different factors in the fractionation process or in the chromatographic separation which affect, to a different extent, the recovery of the sample components. Statistical techniques have been used to show the relative importance of these factors. The improvement in data precision achieved by using volatile compound concentration ratios is discussed.

Chromatography, Gas↗

Determination of coal tar and creosote constituents in the aquatic environment.

Creosote and its parent material, coal tar, are complex mixtures. Upon release their components fractionate into the air, water, soil/sediment and biota; as a function of their physical and chemical properties. Therefore, assessment of their fate and concentrations in the environment must consider a wide variety of both compounds and matrices. Analyses are typically complicated, consisting of sample extraction, purification and chromatography-based final characterization steps. Several new techniques have been introduced to reduce or simplify the number of steps, solvent and time required. Recently developed extraction methods include supercritical fluid, accelerated solvent, microwave and solid-phase microextraction. On-line purification and coupling of extraction and chromatography have also emerged. HPLC and GC remain the major tools for performing the final separations. Application of mass spectrometry has increased as more reliable, versatile and less expensive units have become available, such as the ion trap and mass selective detectors. Fluorescence and diode array UV, in concert with HPLC, and C-, S- and N-selective gas chromatographic detectors are also being applied.

Chromatography↗

Comparative studies of the leachate of an industrial landfill by gas chromatography-mass spectrometry, liquid chromatography-nuclear magnetic resonance and liquid chromatography-mass spectrometry.

Nowadays, the need to have a realistic characterization of industrial effluents in the environment has become more and more recognized. A palette of different analytical methods both for sample extraction and instrumental analysis are available today, some older, others introduced more recently. The aim of this research is to compare a number of these techniques. To do this we studied a real leachate from an industrial landfill and carried out chemical analyses for organic pollutants, using different extraction methods based on solid-phase extraction and solid-phase microextraction and different instrumental techniques such as GC-MS, LC-MS, NMR and LC-NMR. Results show the performances of the different techniques, which are complementary.

Chromatography, Liquid↗

On-line combination of aqueous-sample preparation and capillary gas chromatography.

An overview is presented of methods currently in use to combine the preparation of aqueous samples on-line with capillary gas chromatography. Two approaches can be distinguished: heartcut-orientated reversed-phase liquid chromatography-gas chromatography (GC) and analyte-isolation-orientated analyte extraction-GC. These approaches either use techniques in which water is directly introduced onto the GC column, or an indirect approach in which water is eliminated, i.e., by solid-phase extraction, solid-phase microextraction or liquid-liquid extraction, prior to introduction of the analytes onto the GC column. The latter type of approach is much more successful and user friendly, and many applications have been reported.

Chromatography, Gas↗

On-line combination of aqueous-sample preparation and capillary gas chromatography.

Methods currently in use to combine the preparation of aqueous samples on-line with capillary gas chromatography (GC) comprise heartcut-orientated reversed-phase liquid chromatography-GC and analyte-isolation-orientated analyte extraction-GC. These approaches either use techniques in which water is directly introduced onto the GC column, or an indirect approach in which water is eliminated, i.e., by solid-phase extraction, solid-phase microextraction or liquid-liquid extraction, prior to introduction of the analytes onto the GC column. The latter type of approach is much more successful and user-friendly, and many applications have been reported.

Chromatography, Gas↗

Determination of oak lactones in barrel-aged wines and in oak extracts by stable isotope dilution analysis.

The cis- and trans-isomers of 5-butyl-4-methyl-4,5-dihydro-2(3H)-furanone, the so-called oak lactones, are derived from oakwood, and the cis-isomer is an important contributor to wine flavour. Their deuterium-labelled forms, [2H4]cis-oak lactone and [2H4]trans-oak lactone, were synthesised from the unlabelled analogues, and were utilised in a new method employing gas chromatography-mass spectrometry to determine the concentration of these compounds in wine or extracts of oak shavings in a single analysis. The method can employ either liquid-liquid extraction or solid-phase microextraction, and is both rapid and accurate. There was some artefactual generation of cis-oak lactone during the analysis of model wine extracts of unheated oak shavings when diethyl ether extraction and injector block temperatures at or above 225 degrees C were employed.

Gas Chromatography-Mass Spectrometry↗