PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Biosensors.

Biosensors are analytical devices that respond selectively to analytes in an appropriate sample and convert their concentration into an electrical signal via a combination of a biological recognition system and an electrochemical, optical or other transducer. Such devices will find application in medicine, agriculture, environmental monitoring and the bioprocessing industries. The last few years have seen great advances in the design of sensor architectures, the marriage of biological systems with monolithic silicon and optical technologies, the development of effective electron-transfer systems and the configuration of direct immunosensors. Recent progress in these areas has already led to the introduction of new-generation biosensors into the competitive diagnostics market place.

Biosensing Techniques↗

Heterogeneity of iron bioavailability on plants assessed with a whole-cell GFP-based bacterial biosensor.

Ferric iron is an essential element for microbial growth but its water solubility in aerobic environments is considered to be low. Thus it is a limiting resource for which microbes must compete in natural habitats. Since competition for iron occurs at the level of individual cells, knowledge of the variability in iron bioavailability to such individuals is required to assess the nature of the competition in these habitats. Ferric iron availability to cells of Pseudomonas syringae was assessed by quantifying the fluorescence intensity of single cells harbouring a plasmid-borne transcriptional fusion of an iron-regulated promoter from a locus encoding a membrane receptor for a pyoverdine siderophore with a reporter gene encoding green fluorescent protein (GFP) following fluorescence microscopy. Cells of this iron biosensor exhibited iron-dependent GFP fluorescence that was inversely proportional to the amount of iron added to the media, and which differed by over 20-fold in iron-replete compared to iron-deplete culture media. Cells cultured in a medium of a given iron content exhibited a very narrow range of fluorescence intensities. In contrast, the fluorescence intensity of cells of the biosensor strain recovered from the rhizosphere or phylloplane of inoculated bean plants varied greatly. The distribution of fluorescence intensities was strongly right-hand skewed, with about 10% of the cells exhibiting substantially higher GFP fluorescence than that of the median cell. Cells of a positive control strain, harbouring a fusion of the constitutive nptII promoter with the gfp reporter gene, exhibited uniform GFP fluorescence both in culture media and on plants. These results indicate that there is substantial heterogeneity of iron biovailability to cells of P. syringae on plants, with only a small subset of cells experiencing low iron availability. Such heterogeneity places constraints on models of interactions of bacteria in natural habitats that are based on competition for limited iron.

Biological Availability↗

Sol-gel-based biosensor for use in stroke treatment.

A fiber optic biosensor for the detection of fibrinolytic products produced during lysis of "soft" blood clots is described. The biosensor was constructed to be selective toward D dimer antigens, which form from the dissolution of cross-linked fibrin clots. The presence of D dimer antigens above a threshold level is a clinical diagnostic used to determine the presence of such occlusions following a stroke. Fluorescein-labeled D dimer antibodies are immobilized on the tip of an optical fiber by dip coating from a silica sol-gel solution. When D dimer antigens combine with the antibodies, fluorescence intensity decreases. The response of the sensor was examined in phosphate buffered saline, human plasma, and blood. Calibration plots for the sensor were obtained in the clinically significant D dimer concentration range from 0.54 microgram/ml to 6 micrograms/ml. Changes in spectroscopic properties as the sol-gel encapsulated tagged antibodies aged were examined; a decrease in fluorescence intensity with age was noted. The D dimer antibodies remain viable for at least 4 weeks while encapsulated in the sol-gel network when stored at 4 degrees C in PBS solution. This novel sensor is being developed for use with other catheter-based microtools to treat stroke resulting from occlusion in the vascular system.

Animals↗

Preliminary investigations on a new disposable potentiometric biosensor for uric acid.

In this paper, uricase, catalase, and electron mediator were coimmobilized on the surface of the tin oxide (SnO2)/indium tin oxide (ITO) glass, to develop a disposable potentiometric uric acid biosensor. The SnO2/ITO glass was employed as a pH sensor, fabricated by sputtering SnO2 thin films on the ITO glass. 3-Glycidyloxypropyltrimethoxysilane (GPTS) was utilized to immobilize uricase, catalase and the electron mediator (ferrocenecarboxylic acid, FcA) on the sensing window. The experimental results reveal that the optimal weight ratio of uricase, FcA to catalase (CAT) is 4:1:2. The sensor responds linearly between 2 mg/dl and 7 mg/dl at pH 7.5, in 20 mM of test solution, with a correlation coefficient of 0.99213. Accordingly, no significant interference was observed when interfering substances, glucose, urea and ascorbic acid, were added to the uric acid solution. Moreover, the recorded voltage was relatively constant during the first 28 days of measurement. Consequently, a potentiometric uric acid biosensor was realized with the advantages of low cost and simple fabrication.

Biosensing Techniques↗

Biosensor immunosurface engineering inspired by B-cell membrane-bound antibodies: modeling and analysis of multivalent antigen capture by immobilized antibodies.

Immobilized antibodies are used by many biosensors and diagnostic tests as specific receptors for the presence of targeted substances in clinical, biological, or environmental samples. The antibodies used in these devices are the soluble form of the antibodies presented on the B-cell membrane: they have the same specificity, but they may differ from those presented on the B cell in orientation, flexibility, mobility, and support-membrane properties. These properties influence the formation of noncovalent bonds between the pathogen antigenic determinants (epitopes) and the amino acids of the antibodies. This paper extends the theoretical modeling foundation addressing multivalent antigen binding to cell surface receptors to account for local and far-field antibody surface density effects, immobilized antibodies, and the flexibility and range of motion of immobilized antibodies. An analysis of the derived model provides insight into the design of biosensor immunosurfaces to enhance pathogen capture capability.

Antigen-Antibody Complex↗

Analysis of allosteric signal transduction mechanisms in an engineered fluorescent maltose biosensor.

We previously reported the construction of a family of reagentless fluorescent biosensor proteins by the structure-based design of conjugation sites for a single, environmentally sensitive small molecule dye, thus providing a mechanism for the transduction of ligand-induced conformational changes into a macroscopic fluorescence observable. Here we investigate the microscopic mechanisms that may be responsible for the macroscopic fluorescent changes in such Fluorescent Allosteric Signal Transduction (FAST) proteins. As case studies, we selected three individual cysteine mutations (F92C, D95C, and S233C) of Escherichia coli maltose binding protein (MBP) covalently labeled with a single small molecule fluorescent probe, N-((2-iodoacetoxy)ethyl)-N-methyl)amino-7-nitrobenz-2-oxa-1,3-diazole (NBD), each giving rise to a robust FAST protein with a distinct maltose-dependent fluorescence response. The fluorescence emission intensity, anisotropy, lifetime, and iodide-dependent fluorescence quenching were determined for each conjugate in the presence and absence of maltose. Structure-derived solvent accessible surface areas of the three FAST proteins are consistent with experimentally observed quenching data. The D95C protein exhibits the largest fluorescence change upon maltose binding. This mutant was selected for further characterization, and residues surrounding the fluorophore coupling site were mutagenized. Analysis of the resulting mutant FAST proteins suggests that specific hydrogen-bonding interactions between the fluorophore molecule and two tyrosine side-chains, Tyr171 and Tyr176, in the open state but not the closed, are responsible for the dramatic fluorescence response of this construct. Taken together these results provide insights that can be used in future design cycles to construct fluorescent biosensors that optimize signaling by engineering specific hydrogen bonds between a fluorophore and protein.

Allosteric Site↗

Identification of cognate ligands for the Escherichia coli phnD protein product and engineering of a reagentless fluorescent biosensor for phosphonates.

The Escherichia coli phnD gene is hypothesized to code for the periplasmic binding component of a phosphonate uptake system. Here we report the characterization of the phosphonate-binding properties of the phnD protein product. We find that PhnD exhibits high affinity for 2-aminoethylphosphonate (5 nM), the most commonly occurring natural phosphonate produced by lower eukaryotes, but also binds several other phosphonates with micromolar affinities. A significant number of man-made phosphonates, such as insecticides and chemical warfare agents, are chemical threats and environmental pollutants. Consequently, there is an interest in developing methods for the detection and bioremediation of phosphonates. Bacterial periplasmic-binding proteins have been utilized for developing reagentless biosensors that report analytes by coupling ligand-binding events to changes in the emission properties of a covalently conjugated environmentally-sensitive fluorophore. Several PhnD conjugates described here show large changes in fluorescence upon binding to methylphosphonate (MP), with two conjugates exhibiting up to 50% decrease in emission intensity. Since MP is the final degradation product of many nerve agents, these PhnD conjugates can function as components in a biosensor system for chemical warfare agents.

Biosensing Techniques↗

Binding and signaling of surface-immobilized reagentless fluorescent biosensors derived from periplasmic binding proteins.

Development of biosensor devices typically requires incorporation of the molecular recognition element into a solid surface for interfacing with a signal detector. One approach is to immobilize the signal transducing protein directly on a solid surface. Here we compare the effects of two direct immobilization methods on ligand binding, kinetics, and signal transduction of reagentless fluorescent biosensors based on engineered periplasmic binding proteins. We used thermostable ribose and glucose binding proteins cloned from Thermoanaerobacter tengcongensis and Thermotoga maritima, respectively. To test the behavior of these proteins in semispecifically oriented layers, we covalently modified lysine residues with biotin or sulfhydryl functions, and attached the conjugates to plastic surfaces derivatized with streptavidin or maleimide, respectively. The immobilized proteins retained ligand binding and signal transduction but with adversely affected affinities and signal amplitudes for the thiolated, but not the biotinylated, proteins. We also immobilized these proteins in a more specifically oriented layer to maleimide-derivatized plates using a His(2)Cys(2) zinc finger domain fused at either their N or C termini. Proteins immobilized this way either retained, or displayed enhanced, ligand affinity and signal amplitude. In all cases tested ligand binding by immobilized proteins is reversible, as demonstrated by several iterations of ligand loading and elution. The kinetics of ligand exchange with the immobilized proteins are on the order of seconds.

Biosensing Techniques↗

A simple and reliable assay for detecting specific nucleotide sequences in plants using optical thin-film biosensor chips.

Here we report the adaptation and optimization of an efficient, accurate and inexpensive assay that employs custom-designed silicon-based optical thin-film biosensor chips to detect unique transgenes in genetically modified (GM) crops and SNP markers in model plant genomes. Briefly, aldehyde-attached sequence-specific single-stranded oligonucleotide probes are arrayed and covalently attached to a hydrazine-derivatized biosensor chip surface. Unique DNA sequences (or genes) are detected by hybridizing biotinylated PCR amplicons of the DNA sequences to probes on the chip surface. In the SNP assay, target sequences (PCR amplicons) are hybridized in the presence of a mixture of biotinylated detector probes and a thermostable DNA ligase. Only perfect matches between the probe and target sequences, but not those with even a single nucleotide mismatch, can be covalently fixed on the chip surface. In both cases, the presence of specific target sequences is signified by a color change on the chip surface (gold to blue/purple) after brief incubation with an anti-biotin IgG horseradish peroxidase (HRP) to generate a precipitable product from an HRP substrate. Highly sensitive and accurate identification of PCR targets can be completed within 30 min. This assay is extremely robust, exhibits high sensitivity and specificity, and is flexible from low to high throughput and very economical. This technology can be customized for any nucleotide sequence-based identification assay and widely applied in crop breeding, trait mapping, and other work requiring positive detection of specific nucleotide sequences.

Alleles↗

Binding of Tamm-Horsfall protein to complement 1q measured by ELISA and resonant mirror biosensor techniques under various ionic-strength conditions.

The purpose of the present study was to quantify the binding affinity between Tamm-Horsfall protein (THP) and complement 1q (C1q) using ELISA and a resonant mirror biosensor. In ELISA, immobilized THP was incubated with soluble C1q under both low and physiological ionic-strength conditions. Tamm-Horsfall protein bound C1q with an equilibrium dissociation constant (KD) of 1.9 +/- 0.6 nmol/L in low ionic-strength Tris buffers (20 mmol/L NaCl, pH 7.5) and with a lower affinity (KD of 13.4 +/- 4.7 nmol/L) in physiological-strength Tris buffers (154 mmol/L NaCl, pH 7.5). A resonant mirror biosensor, which monitors binding events in real-time, was used to quantify the KD of this reaction, as well as to estimate the kinetic parameters. In these studies, THP and C1q bound with an association rate constant, kass, of 1.25 x 105 L/mol per s and a dissociation rate constant, kdiss, of 0.002-0.005/s. The calculated KD for the THP/C1q binding in low ionic-strength buffers was higher (averages of 10-15 nmol/L) than that obtained by the ELISA, while physiological ionic-strength buffers still reduced the affinity of this binding by an order of magnitude. In conclusion, THP consistently bound C1q with high affinity using several techniques. At least a portion of this interaction involved electrostatic events, as demonstrated by the influence of ionic strength on the binding affinity.

Adjuvants, Immunologic↗

Biosensor applications to antitachycardia devices.

Current arrhythmia detection algorithms are unable to adequately distinguish stable from unstable tachycardias; therefore application of a biosensor to antitachycardia devices has been proposed to improve their performance. Right heart pressures and impedance have been investigated for incorporation into these systems. Integration of other parameters (oxygen saturation, preejection period, pH, cardiac output, flow, and temperature) into these devices might also prove useful. The status of these biosensor arrhythmia detection algorithms and their application to antitachycardia devices are described below.

Algorithms↗

Cross-reactive potential of rabbit antibodies raised against a cyclic peptide representing a chimeric V3 loop of HIV-1 gp120 studied by biosensor technique and ELISA.

Rabbit antibodies were induced against a free cyclic peptide representing the chimeric sequence of a consensus V3 loop of HIV-1 gp120. The reactivity of these antibodies was tested in a biosensor system (BIAcore, Pharmacia AB, Uppsala, Sweden) and in ELISA with the peptide immunogen in its cyclic and linear forms, as well as with peptides corresponding to the V3 region of different HIV-1 variants. The antibodies reacted with all the peptides tested both in ELISA and in biosensor assays and recognized the cyclic form of the chimeric peptide better than the linear form. Although antibodies raised against the V3 region of particular HIV-1 variants cross-react with other HIV-1 strains, it seems that the use of a chimeric peptide as immunogen improved the cross-reactivity spectrum of recognition of the antibodies. The anti-V3 antibodies were also tested for their ability to neutralize in vitro four HIV-1 laboratory strains. Only the HIVMN variant was found to be neutralized. Compared to conventional solid phase immunoassays, the BIAcore presents several advantages for measuring the differential reactivity of peptide analogues. In view of their broadly cross-reactive potential, antibodies raised against a consensus sequence should be useful in immunodiagnosis of viral antigenic variants.

Amino Acid Sequence↗

Lux-biosensor assessment of pH effects on microbial sorption and toxicity of chlorophenols.

Lux-marked bacterial biosensors and a commercial toxicity testing bacterial strain (Microtox) were exposed to 2,4-dichlorophenol (DCP) and the light output response measured. Increasing DCP concentrations caused a decrease in light output in all three biosensors with an order of sensitivity (in terms of luminescence decrease over the DCP concentration range) of Pseudomonas fluorescens < Escherichia coli < Microtox. Adsorption of DCP to E. coli was measured using uniformly ring labelled [14C]DCP and found to be very rapid. The effect of pH on toxicity and adsorption was also investigated. Low pH values increased the amount of DCP adsorbed to the cell and increased the toxicity of DCP.

Adsorption↗

Versatile biosensor vectors for detection and quantification of mercury.

Three different whole cell biosensor constructs were made by fusing the mercury inducible promoter, P(mer), and its regulatory gene, merR, from transposon Tn21 with reporter genes luxCDABE, lacZYA, or gfp. In Escherichia coli these biosensor constructs responded to low levels of mercury by producing light, beta-galactosidase or green fluorescent protein, respectively. Since the responses were quantitative, the constructs were used to quantify bioavailable mercury in different environments. The constructs were cloned into mini-Tn5 delivery vectors, thus enabling the transfer of the mer-lux, mer-lac or mer-gfp cassettes to a variety of Gram-negative bacteria. The mer-lux cassette was transferred to a Pseudomonas putida strain, which was used to quantify water-extractable mercury in contaminated soil.

Bacterial Proteins↗

Construction of a modified mini-Tn5 luxCDABE transposon for the development of bacterial biosensors for ecotoxicity testing.

A mini-Tn5 transposon was modified to introduce a promoterless luxCDABE cassette from Vibrio fischeri into environmentally relevant bacterial strains in order to develop bioluminescence-based biosensors for toxicity testing. The mini-Tn5 luxCDABE transposon was chromosomally integrated downstream from an active promoter into two Pseudomonas strains (Pseudomonas fluorescens 8866 and Pseudomonas putida F1). Characterisation of the bioluminescent transconjugants demonstrated that the transposon integration was stable and had no effect on growth rate. Both P. fluorescens 8866 Tn5 luxCDABE and P. putida F1 Tn5 luxCDABE were used to assess the toxicity of standard solutions (Cu, Zn and 3,5-DCP) as well as Cu- and 3,5-DCP-spiked groundwater samples. They were successfully used for bioluminescence-based bioassays and the potential value of using different bacterial biosensors for ecotoxicity testing was shown.

Bacteria↗

Detection of quorum-sensing N-acyl homoserine lactone signal molecules by bacterial biosensors.

Many Gram-negative bacteria use N-acyl homoserine lactones (AHLs) as quorum-sensing (QS) signal molecules. AHL QS has been the subject of extensive investigation in the last decade and has become a paradigm for bacterial intercellular signaling. Research in AHL QS has been considerably aided by simple methods devised to detect AHLs using bacterial biosensors that phenotypically respond when exposed to exogenous AHLs. This article reviews and discusses the currently available bacterial biosensors which can be used in detecting and studying the different AHLs.

4-Butyrolactone↗

Study of MMLV RT- binding with DNA using surface plasmon resonance biosensor.

Surface plasmon resonance biosensor technique was used to study the binding of Moloney murine leukemia virus reverse transcriptase without RNase H domain (MMLV RT-) with DNA in the absence and in the presence of inhibitors. Different DNA substrates, including single-stranded DNA (ssDNA), DNA template-primer (T-P) duplex and gapped DNA, were immobilized on the biosensor chip surface using streptavidin-biotin, and MMLV RT(-)-DNA binding kinetics were analyzed by different models. MMLV RT-; could bind with ssDNA and the binding was involved in conformation change. MMLV RT-; binding DNA T-P duplex and gapped DNA could be analyzed using the simple 1:1 Langmuir model. The lack of RNase H domain reduced the affinity between MMLV RT-; and T-P duplex. The effects of RT inhibitors, including efavirenz, nevirapine and quercetin, on the interaction between MMLV RT-; and gapped DNA were analyzed according to recovered kinetics parameters. Efavirenz slightly interfered with the binding between RT and DNA and the affinity constant in the presence of the inhibitor (K(A) = 1.21 x 10(6) M(-1)) was lower than in the absence of the inhibitor (KA = 4.61 x 10(6) M(-1)). Nevirapine induced relatively tight binding between RT and DNA and the affinity constant in the presence of the inhibitor (K(A) = 1.47 x 10(7) M(-1)) was approximately three folds higher than without nevirapine, mainly due to rapid association and slow dissociation. Quercetin, a flavonoid originating from plant which has previously shown strong inhibition of the activity of RT, was found to have minimal effect on the RT-DNA binding.

Alkynes↗

[Real time observation of binding of measles virus to Vero cells and neutralization of measles virus by human immunoglobulin using optical biosensor--a new real time diagnosis system for viral infections].

An optical biosensor to monitor molecular intractions was developed. This system made possible to observe reactions with a few minutes. We tried to apply this system for rapid diagnosis of viral infections. Measles virus propagated in our laboratory and crude rabbit anti-measles antiserum were used. A commercially available human immunoglobulin was used as a representative of patient sera. A crude rabbit anti-measles antiserum was fixed on the reaction surface of aminosilane coated cuvette, and specific binding of measles virus to this antibody was monitored. Specific purified IgG antibody was known to give as high sensitivity as the conventional culture method. But the sensitivity by crude antibody was found to be 1/10 in the sensitivity. This might be caused by the masked effects on specific antibody to the contaminated high amounts of non-specific proteins. None purified polyclonal antisera for most of the viruses are commercially available, and 10-20 times highly concentrated antibody solutions could be used for this titrations. Estimated anti-measles antibody titer of the commercial available human immunoglobulin by biosensor system was found to be the same as that by the conventional culture method. It was suggested that 1 X 10(3) virus particles/ml in the test solutions could be detectable and titerable by using commercially available specific anti-viral antibody in real time, and the viral infections could be diagnosed within an hour.

Animals↗