PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Body Fluids”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Radioimmunoassay for the amino-terminal sequences of type III procollagen in human body fluids measuring fragmented precursor sequences.

Antisera specifically directed against the amino-terminal precursor sequence of bovine p-N-collagen type III (Col 1-3 III) have been raised in rabbit. When tested in a radioimmunoassay, parallel displacement curves and complete cross-reactivity were observed between bovine and human purified Col 1-3 III. However, these displacement curves were not parallel to that obtained with serially diluted human sera which presented a smoother slope. Cleavage of the Col 1-3 III peptide by collagenase at high temperature yielded an immunoreactive preparation containing two smaller peptides (Col 1 plus Col 2) III. The displacement curves obtained with human or bovine (Col 1 plus Col 2) preparations were parallel to those obtained with serially diluted human sera or other human body fluids (amniotic and ascitic fluids). Quantitative measurements of the circulating antigen in normal and pathological conditions are possible only when the (Col 1 plus Col 2) is used as standard antigen. This radioimmunoassay represents an original and simple technique offering good accuracy. The amount of (Col 1 plus Col 2) III in human adults is 69.1 +/- 27.7 ng/ml, with a distribution of frequency close to the normal. It is increased in liver cirrhosis and other conditions characterized by an active neoformation of connective tissue.

Adult↗

The effect of Ca/P concentration and temperature of simulated body fluid on the growth of hydroxyapatite coating on alkali-treated 316L stainless steel.

316L-SS is one of the important materials both in orthopaedics and dentistry for bone screw/plate, intra-medullary rod, fixation wire, HIP joint, and knee joint. However, the biocompatibility and bone-bonding ability troubled researches for years. In the study, a simple chemical method was tried so as to establish and induce a bioactive HA layer on the surface of 316L stainless steel. When the metallic substrates treated with 10 M NaOH aqueous solution and subsequently heated at 600 degrees C, a thin sodium chromium oxide layer was formed on the surfaces as the linking layer for HA and 316L-SS. After 316L-SS treated with alkali solution, it would soak into a simulated body fluid with higher concentration of calcium and phosphorous ions to increase the possibility of nucleation of HA. However, the iron oxide and iron chromium oxides were formed on the surface when calcium and phosphorous ions increased. This resulted in loosening the HA layer. When the alkali-treated 316L-SS was soaked into SBF at a temperature of 80 degrees C, it could form a dense and uniform bone-like hydroxyapatite layer on the surface. In the research, the mechanism of the formation of sodium chromium oxide and HA would also be described by the analysis of X-ray diffractometer, scanning electron microscope, energy-dispersion spectrophotometer, and Fourier transformation infrared.

Alkalies↗

Measurement of deoxyribonuclease I activity in human tissues and body fluids by a single radial enzyme-diffusion method.

In the single radial enzyme-diffusion (SRED) method for assay of deoxyribonuclease I, a precisely measured volume of the enzyme solution is dispensed into a circular well in an agarose gel layer in which DNA and ethidium bromide are uniformly distributed. A circular dark zone is formed as the enzyme diffuses from the well radially into the gel and digests substrate DNA. The diameter of the dark circle of hydrolyzed DNA increases in size with time and correlates linearly with the amount of enzyme applied to the well. Thus, the SRED can be used for quantitation of deoxyribonuclease I with a limit of detection of 2 x 10(-6) unit. This corresponds to 1 pg of purified urine deoxyribonuclease I. We measured the deoxyribonuclease I activity of 17 different human tissues and body fluids from healthy donors. Urine samples showed the greatest activity, 6.0 +/- 2.2 kilo-units/g protein (mean +/- SD). Serum deoxyribonuclease I activity was 4.4 +/- 1.8 units/L.

Adult↗

Radioimmunoassay of hexoestrol residues in faeces, tissues and body fluids of bulls and steers.

A fast, reliable and sensitive radioimmunoassay method using either 3H-hexoestrol or a 125I-hexoestrol derivative as the competitive radioligand has been developed for the measurement of residues of hexoestrol in faeces. The blank value for untreated cattle was 113 +/- 98 pg/g faeces, the intra-assay coefficient of variation 10.8 per cent, interassay coefficient of variation 11.1 per cent and recovery of 3H-hexoestrol added to faeces was 58.7 per cent. The concentration of hexoestrol in faeces was measured in 18 steers and 14 bulls at regular intervals after implantation of 36, 45 and 60 mg of hexoestrol. Residues were detected in all samples up to 104 days after implantation and in nine out of 13 samples taken 111 to 153 days after implantation. Residues of hexoestrol were also measured in edible tissues and body fluids of 14 bulls and eight steers slaughtered between 90 and 153 days after implantation of 45 mg hexoestrol. The percentages of samples containing residues were 82, 73, 64, 82 and 27 per cent for bile, urine, liver, kidney and muscle, respectively.

Animals↗

A simple analysis of 5 thinner components in human body fluids by headspace solid-phase microextraction (SPME).

A simple method for the extraction of 5 thinner components from human whole blood and urine, using the headspace solid-phase microextraction (SPME) method is presented. After heating a vial containing the samples with 5 compounds (toluene, benzene, n-butyl acetate, n-butanol and n-isoamyl acetate) at 80 degrees C, a polydimethylsiloxane-coated SPME fiber was exposed to the headspace of the vial to allow adsorption of the compounds. The fiber needle was then injected into a capillary gas chromatography (GC) port. The headspace SPME-GC gave intense peaks for each compound and a low level of background noise was seen only for whole blood. Recovery rates of the 5 compounds by use of the headspace SPME-GC were 50-70%. Reproducibility for headspace SPME-GC data were excellent for both body fluids. The calibration curves showed linearity in the range 2-100 ng/0.5 ml whole blood or urine. The detection limits of each compound were 1.1-2.4 ng/0.5 ml sample. The present results on the analysis of 5 thinner components by headspace SPME-GC suggest its applicability to a number of other volatile compounds in forensic toxicology.

1-Butanol↗

Bioassay detects soluble MAdCAM-1 in body fluids.

Mucosal addressin cell adhesion molecule (MAdCAM-1) is a key player in mediating the infiltration of leucocytes into chronically inflamed tissues. Five anti-MAdCAM-1 monoclonal antibodies (mAb), designated 17F5, 201F7, 314G8, 377D10 and 355G8, were generated by fusion of P3 x 63Ag8.653 myeloma cells with spleen cells from BALB/c mice immunized with recombinant human MAdCAM-1-Fc. The latter four mAb recognize the ligand-binding first Ig domain, and block T -cell adhesion to MAdCAM-1. The non-blocking mAb 17F5 recognizes the mucin domain. Extensive analysis of a large panel of paraffin-embedded human tissues revealed that the 314G8 mAb detected MAdCAM-1 on venules in the spleen and small intestine. MAdCAM-1 was strongly expressed in the synovium of osteoarthritis patients, predominantly on the endothelial lining of blood vessels, but also within the vessel lumen. An ELISA, based on mAb 377D10 and 355G8, was developed to determine whether soluble MAdCAM-1 was present in body fluids, and to measure the levels present. The assay detected soluble MAdCAM-1 in the serum and urine of healthy donors, at levels similar to those of soluble forms of the related CAM, ICAM-1 and VCAM-1. The anti-MAdCAM-1 antibodies and assay developed here may be useful therapeutically in the treatment of inflammation in humans. Similarly, they may be useful diagnostically to monitor the presence and levels of MAdCAM-1.

Animals↗

Blood pressure, body fluid volumes and glomerular filtration rate during treatment with labetalol in essential hypertension.

1 In a single blind study seventeen patients with mild or moderate essential hypertension and normal renal function were treated with labetalol alone in increasing doses from 300 via 600 to 1200 mg daily. 2 Average supine BP (systolic/diastolic) was reduced by 24/19 mm Hg. Seven patients attained a diastolic BP less than or equal to Hg. A significant postural fall in systolic BP was recorded, but no symptomatic orthostatic hypotension occurred. 3 In twelve patients measurements of plasma volume (125I-albumin), extracellular volume (82Br-space) and glomerular filtration rate (51Cr-EDTA clearance) on placebo and subsequently labetalol showed no systemic changes. 4 Side effects were few causing two withdrawals because of impotence and arthralgia. 5 It is concluded that monotherapy with labetalol results in clinically relevant, persistent and dose dependent reduction in BP in patients with mild or moderate essential hypertension, apparently without concomitant expansion of body fluid volumes or influence on glomerular filtration rate.

Adult↗

Body fluids and temperature responses of heat-exposed women before and after ovulation with and without rehydration.

1. Four females (21-25 yr) were exposed to 43.3 degrees C dry bulb, 28-29 degrees C wet bulb, for 10 hr both early and late in two menstrual cycles. During the experiments in one cycle, the subjects were rehydrated while during the experiments in another cycle, the subjects were allowed to progressively dehydrate.2. Rates of weight loss and oral temperatures were determined hourly while venous blood samples were obtained before and then after 1, 2, 3, 4, 6, 8, and 10 hr of heat exposure.3. Pre-ovulatory results were compared with post-ovulatory results and dehydration experiments with rehydration experiments. In addition, the data on these female subjects were compared with those presented elsewhere for similarly treated male subjects.4. When compared to males, these resting females did not significantly haemodilute when heat exposed. In addition, the female subjects apparently suffered a decrease in plasma volume and body water at a rate some 1.5 times that of similarly exposed males.5. In general,% change in total protein/unit volume of plasma for these female subjects was similar to previously published results for males. However, there were significant differences in the manner in which albumin and globulin fractions changed before and after ovulation.6. The rates of body weight loss for these subjects were similar to those determined for males. No difference was noted between pre- and post-ovulatory rates of weight loss. Dehydration significantly depressed the rates of weight loss during heat exposure.7. Stimulation of sweating (assessed as weight loss) appeared to require similar amounts of heat storage before and after ovulation though initial post-ovulatory temperatures were generally higher.8. Progressive dehydration of females before ovulation was accompanied by rates of increase in oral temperatures that were similar to those seen for similarly exposed males.9. When females progressively dehydrated after ovulation, there was no statistically significant correlation between temperature rise and weight loss as had been noted in pre-ovulatory experiments. In addition, for all subjects, the rise in body temperature with dehydration was less after than before ovulation. Two subjects showed an ability to decrease their body temperature in the face of continued dehydration.10. Based on these results, the differences in the responses of males and females to heat exposure were ascribed mainly to two causes: a, inherent differences such as skin surface: blood volume ratios, and b, the inability of females to maintain their vascular volume during heat exposure.

Adult↗

[Diagnostic characteristics of the CA-50 and CA 72-4 tumor markers in body fluids. Use in the diagnosis of malignant effusions].

The paper presents the results of a comparative investigation of CA-50 and CA 72-4 in the serum and effusions of the control group and a group of patients with various localizations of malignant tumors. The diagnostic applicability of CA-50 in the serum is limited by a substantial extent of falsely positive results, which is not the case with CA 72-4. Malignant cells make a more intensive release of CA 72-4 into effusions than into the blood, and the situation with CA-50 is reverse. It has been established that CA-50 in the serum and that CA 72-4 in effusions are complementary parameters. Markers in effusions have more favorable diagnostic characteristics in relation to serum. Although CA 72-4 is of a more superior diagnostic reliability, the examining of both markers is of help in the differentiation of benign peritoneal and pleural effusions from the malignant ones. The persistence of these markers in body fluids does not indicate the primary origin of malignant tumors.

Antigens, Tumor-Associated, Carbohydrate↗

Analysis of methanol or formic acid in body fluids by headspace solid-phase microextraction and capillary gas chromatography.

Methanol and its metabolite formic acid have been found extractable from human whole blood and urine by headspace solid-phase microextraction (SPME) with a Carboxen/polydimethylsiloxane fiber. The headspace SPME for formic acid was carried out after derivatization to methyl formate under acidic conditions. The determinations of both compounds were made by using acetonitrile as internal standard (IS) and capillary gas chromatography (GC) with flame ionization detection. The headspace SPME-GC gave sharp peaks for methanol, methyl formate and I.S.; and low background noises for whole blood and urine samples. Extraction efficiencies were 0.25-1.05% of methanol and 0.38-0.84% formic acid for whole blood and urine. The calibration curves for methanol and formic acid showed excellent linearity in the range of 1.56 to 800 and 1.56 to 500 microg/0.5 ml of whole blood or urine, respectively. The detection limits were 0.1-0.5 microg/0.5 ml for methanol and 0.6 microg/0.5 ml for formic acid for both body fluids. The within-day relative standard deviations in terms of extraction efficiency for both compounds in whole blood and urine samples were not greater than 9.8%. By using the established SPME method, methanol and formic acid were successfully separated and determined in rat blood after oral administration of methanol.

Acetonitriles↗