PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Cochlear Implants”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Preoperative functional assessment of auditory cortex in adult cochlear implant users.

OBJECTIVES: To explore functional neuroanatomical responses to auditory stimulation before and after implantation. STUDY DESIGN: A prospective study of three cochlear implant candidates (pure-tone averages of 90 dB HL or greater bilaterally and hearing in noise test [HINT] performances of <40%) in which regional cerebral blood flow (rCBF) was assessed using single photon emission computed tomography (SPECT). METHODS: Candidates watched a 15-minute videotaped story under four conditions: audio presented monaurally in the right and left ears (aided), audio presented binaurally (aided), and visual-only presentation of the story. Five minutes into each story, 20 to 25 mCi of technetium 99m (99mTc) hexamethyl-propyleneamine-oxime (HMPAO) (Ceratec; Nycomed Amersham, Princeton, NJ, U.SA) was injected over a 30-second period to ensure that subjects were unaware of tracer administration. Subjects were scanned for 20 minutes using a PRISM 3000 gamma camera (Picker International, Cleveland, OH, U.S.A.). Data were normalized and co-registered, and subtraction images were compiled. Subtraction images contrasted activation patterns generated under the visual-only control condition to the auditory activation states acquired monaurally and binaurally. RESULTS: Right and left ear monaural stimulation in normal hearing subjects resulted in significant bilateral activation of Brodmann areas 41, 42, 21, 22, and 38. Although substantial intersubject response variability was noted, subjects generally failed to bilaterally activate these areas under monaural hearing aid presentations; however, bilateral activation of areas 41 and 22 was noted under binaural presentations. CONCLUSIONS: Despite relatively similar hearing losses in each ear, significant differences in preoperative auditory cortex activation were observed between ears. These data suggest that functional brain imaging provides a useful tool for exploring the responsiveness of the auditory cortex in cochlear implant candidates.

Acoustic Stimulation↗

Effect of cochlear implantation on residual spiral ganglion cell count as determined by comparison with the contralateral nonimplanted inner ear in humans.

It is generally assumed that at least a minimal number of spiral ganglion cells is essential for successful speech perception with a cochlear implant. Although the insertion of a multichannel cochlear implant frequently results in loss of residual hearing in the implanted ear, this outcome does not imply that significant damage to residual populations of spiral ganglion cells has occurred. The purpose of the current study was to compare spiral ganglion cell counts in implanted and nonimplanted cochleas in 11 patients for whom both temporal bones were available and in whom a multichannel cochlear implant had been placed unilaterally. The temporal bones were processed for light microscopy by standard techniques. The cochleas were reconstructed by 2-dimensional methods. Spiral ganglion cell counts of the implanted and nonimplanted sides were compared by a paired t-test (2-tailed). The mean spiral ganglion cell counts for implanted and nonimplanted ears were not statistically different in the most basal three segments of the cochlea. However, the mean spiral ganglion cell count in segment 4 (apical segment) and the mean total spiral ganglion cell count were lower in the implanted cochleas than in the nonimplanted cochleas (p < .01). The results of this study suggest a modest decrease in the total spiral ganglion cell count in the implanted ears as compared to the nonimplanted ears, principally in the apical segment. Possible interpretations of this finding are discussed.

Aged↗

Cochlear nerve aplasia: its importance in cochlear implantation.

OBJECTIVE: The objective of this study was to outline the possible implications and potentially valuable techniques for managing cases in which the neural integrity of the peripheral auditory system is in question. STUDY DESIGN: This study was a retrospective case review. SUBJECT AND METHOD: A 3-year-old child with a profound blilateral sensorineural hearing loss was assessed for suitability of cochlear implantation. Audiologic tests confirmed that the child met the audiologic criteria for cochlear implantation. Computed tomographic scanning and magnetic resonance imaging were undertaken. RESULTS: Computed tomographic scanning showed bilateral narrow internal auditory canals. Magnetic resonance imaging showed the absence of the acousticofacial bundle on the left side and possible atrophy of the bundle on the right. After detailed discussion, the parents elected to proceed with implantation on the right ear using the Nucleus mini-22 cochlear implant. Tuning of the device resulted in myogenic facial activity with no electrically stimulated auditory sensation. Postoperative electrophysiologic testing confirmed the presence of a compound muscle action potential only. CONCLUSIONS: Seven months after implantation, the child was explanted uneventfully. The electrical auditory nerve action potential and the electrically evoked auditory brainstem response, using intracochlear stimulation, are potentially valuable measurements to assess neural integrity before the decision to proceed with implantation is made.

Atrophy↗

An outcomes study of cochlear implants in deaf patients. Audiologic, economic, and quality-of-life changes.

OBJECTIVES: To investigate and quantitate the changes in economic, emotional, and health-related quality of life after cochlear implantation. SUBJECTS: Nine patients between the ages of 18 and 60 years who qualified for surgery. METHODS: Patients underwent assessment using four socioeconomic indicator scales administered preoperatively, and at 6 months, 1 year, 2 years, 30 months, and 3 years postoperatively. All patients continued to use their cochlear implants during the 3-year follow-up period. RESULTS: Uniform and systematic improvement in quality of life and psychologic well-being, and a steady increase in mean personal income for the group that underwent implantation, supporting the contention that cochlear implantation is a beneficial surgical procedure for profoundly deaf patients.

Adult↗

Influence of automatic gain control parameter settings on speech understanding of cochlear implant users employing the continuous interleaved sampling strategy.

OBJECTIVE: The purpose of the present study was to gather data on the influence of compression ratio and attack and release times of slow-acting front-end automatic gain control (AGC) systems on speech understanding of cochlear implant users in various listening situations. The data should allow evaluation of the usefulness of front-end AGC in body-worn speech processors. DESIGN: Subjects were 12 experienced postlingually deafened adult users of the Med-El Combi-40 multichannel cochlear implant. Six different front-end configurations, including a linear setting, the standard AGC of the Med-El Combi-40 processor, and four slow-acting dual front-end AGCs (use of two instead of one level detector for improved transient handling), were evaluated in two experiments. In experiment 1, tests were performed at 55, 70 and 85 dB SPL, roughly corresponding to soft, medium and loud speech. Experiment 2 was intended to evaluate the quality of transient handling of the six configurations. In this experiment an intense transient ("chink") at 100 dB SPL was spliced onto the beginning of each sentence (presented at 85 dB SPL). RESULTS: At 55 dB SPL subjects performed significantly more poorly with the linear setting than with the AGC settings, but no differences in performance could be found for the AGC settings. At 70 dB SPL subjects showed the poorest performance with the high compression ratio dual front-end AGCs. No differences in performance of the six front-end configurations were found at 85 dB SPL. In the presence of intense chinks, performance of the standard AGC dropped significantly. CONCLUSIONS: The results indicate that slow-acting front-end AGC can be used effectively in speech processors for cochlear implants to expand the range of input levels that are audible for the cochlear implant user, without any need to adjust a processor control, and that incorporation of an additional fast-acting AGC component can improve performance under conditions where intense transients occur.

Adult↗

Multichannel cochlear implantation in radical mastoidectomy cavities.

OBJECTIVE: We report on our experience in cochlear implantation in patients with radical mastoidectomy cavities. Study Design, Setting, and Methods: Retrospectively, records of patients from the Department of Otolaryngology, University of Parma between December 1991 and March 2000 were reviewed, and 6 postlingually deafened adults who received a cochlear implant in a radical cavity were identified. Speech performances were evaluated in terms of bisyllabic word and sentence recognition and common phrase comprehension. RESULTS: To date, with a follow-up of 1 to 9 years, no patient has experienced extrusion of electrodes or other local or intracranial complications. Mean bisyllabic word and sentence recognition scores were 74% and 80%, respectively. Mean comprehension score for common phrases was 86%. CONCLUSION: By obliterating and isolating the radical mastoidectomy cavity from the outer environment, patients who previously had undergone radical surgery of the middle ear can be safely implanted with satisfactory hearing results.

Adult↗

An investigation of input level range for the nucleus 24 cochlear implant system: speech perception performance, program preference, and loudness comfort ratings.

OBJECTIVE: Cochlear implant recipients often have limited access to lower level speech sounds. In this study we evaluated the effects of varying the input range characteristics of the Nucleus 24 cochlear implant system on recognition of vowels, consonants, and sentences in noise and on listening in everyday life. DESIGN: Twelve subjects participated in the study that was divided into two parts. In Part 1 subjects used speech processor (Nucleus 24 SPrint trade mark ) programs adjusted for three input sensitivity settings: a standard or default microphone sensitivity setting (MS 8), a setting that increased the input sensitivity by 10.5 dB (MS 15), and the same setting that increased input sensitivity but also incorporated the automatic sensitivity control (ASC; i.e., MS 15A) that is designed to reduce the loudness of noise. The default instantaneous input dynamic range (IIDR) of 30 dB was used in these programs (i.e., base level of 4; BL 4). Subjects were tested using each sensitivity program with vowels and consonants presented at very low to casual conversational levels of 40 dB SPL and 55 dB SPL, respectively. They were also tested with sentences presented at a raised level of 65 dB SPL in multi-talker babble at individually determined signal to noise ratios. In addition, subjects were given experience outside of the laboratory for several weeks. They were asked to complete a questionnaire where they compared the programs in different listening situations as well as the loudness of environmental sounds, and state the setting they preferred overall. In Part 2 of the study, subjects used two programs. The first program was their preferred sensitivity program from Part 1 that had an IIDR of 30 dB (BL 4). Seven subjects used MS 8 and four used MS 15, and one used the noise reduction program MS 15A. The second program used the same microphone sensitivity but had the IIDR extended by an additional 8 to 10 dB (BL 1/0). These two programs were evaluated similarly in the speech laboratory and with take-home experience as in Part 1. RESULTS PART 1: Increasing the microphone input sensitivity by 10.5 dB (from MS 8 to MS 15) significantly improved the perception of vowels and consonants at 40 and 55 dB SPL. The group mean improvement in vowel scores was 25 percentage points at 40 dB SPL and 4 percentage points at 55 dB SPL. The group mean improvement for consonants was 23 percentage points at 40 dB SPL and 11 percentage points at 55 dB SPL. Increased input sensitivity did not significantly reduce the perception of sentences presented at 65 dB SPL in babble despite the fact that speech peaks were then within the compressed range above the SPrint processor's automatic gain control (AGC) knee-point. Although there was a demonstrable advantage for perception of low-level speech with the higher input sensitivity (MS 15 and 15A), seven of the 12 subjects preferred MS 8, four preferred MS 15 or 15A, and one had no preference overall. Approximately half the subjects preferred MS 8 across the 18 listening situations, whereas an average of two subjects preferred MS 15 or 15A. The increased microphone sensitivity of MS 15 substantially increased the loudness of environmental sounds. However, use of the ASC noise reduction setting with MS 15 reduced the loudness of environmental sounds to equal or below that for MS 8. RESULTS PART 2: The increased instantaneous input range gave some improvement (8 to 9 percentage points for the 40 dB SPL presentation level) in the perception of consonants. There was no statistically significant increase in vowel scores. Mean scores for sentences presented at 65 dB SPL in babble were significantly lower (5 percentage points) for the increased IIDR setting. Subjects had no preference for the increased IIDR over the default. The IIDR setting had no effect on the loudness of environmental sounds. CONCLUSIONS: Given the fact that individuals differ in threshold (T) and comfort (C) levels for electrical stimulation, and preferred microphone sensitivity, volume control, and noise-reduction settings, it is essential for the clinicid recipient to determine what combination is best for the individual over several sessions. The results of this study clearly show the advantage of using higher microphone sensitivity settings than the default MS 8 to provide better speech recognition for low-level stimuli. However, it was also necessary to adjust other parameters such as map C levels, automatic sensitivity control and base level, to optimize loudness comfort in the diversity of listening situations an individual encounters in everyday life.

Auditory Threshold↗

[Vestibular function in cochlear implants--prognostic factors and postoperative damage].

Eighteen patients with a 22-channel cochlear implant were evaluated both pre- and postoperatively with vestibular function tests; caloric test and body balance test using stabilometry. Preoperative promontory stimulation results and postoperative psychophysical factors of the cochlear implant showed no correlation with the preoperative vestibular function test results. The results of speech perception tests were not affected by the degree of residual vestibular function in any of the patients. However, for patients with deafness for a period of 10 to 20 years, the degree of the residual vestibular function estimated by the caloric test showed a correlation with the results of speech perception tests, significantly in the consonant recognition score. The results, not of length or the Rombberg ratio, but rather of the area of body sway, showed a correlation with the results of speech perception tests; consonant recognition, in patients with a short duration of deafness. Therefore preoperative vestibular function results may be useful as a predictive factor in postoperative speech perception; consonant recognition, for patients with a short duration of deafness. Reduced results of caloric testing after surgery were found in one of 11 patients (9%) with residual vestibular function. The occurrence of vertigo immediately after surgery was observed in 5 of 18 patients (28%), but this symptom was transient. No change in stabilometry results, pre-versus post-operatively, was observed. Thus, vestibular damage after surgery was considered to be minimal.

Adult↗

Phonological abilities of hearing-impaired Cantonese-speaking children with cochlear implants or hearing AIDS.

PURPOSE: This article examined the phonological skills of 2 groups of Cantonese-speaking children with prelingual, profound bilateral hearing loss. The phonological abilities of 7 children fitted with hearing aids were compared with the abilities of 7 children who wore cochlear implants. METHOD: Participants in each group ranged in age from 5;1 to 6;4 years. The participants were asked to name 57 pictures and retell 2 stories. Phonological abilities were described in terms of the participants' phonological units and the phonological processes used. The participants' perception of single words was assessed using a Cantonese phonology test that includes tonal, segmental, and semantic distracters. RESULTS: All except 1 participant had incomplete phonetic repertories. All participants showed complete vowel and tone inventories. The study group used both developmental rules and nondevelopmental phonological rules. For perception of single words, participants chose the target word most often. The cochlear implant users had a significantly higher percentage correct score for consonant production than hearing aid users. CONCLUSIONS: The prediction that Cantonese children wearing cochlear implants would have better phonological skills than children having hearing aids with a similar degree of hearing loss was confirmed. Cochlear implant usage appeared to promote consonant feature production development to a greater degree than did the use of a hearing aid.

Articulation Disorders↗

Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants.

Speech recognition was measured as a function of spectral resolution (number of spectral channels) and speech-to-noise ratio in normal-hearing (NH) and cochlear-implant (CI) listeners. Vowel, consonant, word, and sentence recognition were measured in five normal-hearing listeners, ten listeners with the Nucleus-22 cochlear implant, and nine listeners with the Advanced Bionics Clarion cochlear implant. Recognition was measured as a function of the number of spectral channels (noise bands or electrodes) at signal-to-noise ratios of + 15, + 10, +5, 0 dB, and in quiet. Performance with three different speech processing strategies (SPEAK, CIS, and SAS) was similar across all conditions, and improved as the number of electrodes increased (up to seven or eight) for all conditions. For all noise levels, vowel and consonant recognition with the SPEAK speech processor did not improve with more than seven electrodes, while for normal-hearing listeners, performance continued to increase up to at least 20 channels. Speech recognition on more difficult speech materials (word and sentence recognition) showed a marginally significant increase in Nucleus-22 listeners from seven to ten electrodes. The average implant score on all processing strategies was poorer than scores of NH listeners with similar processing. However, the best CI scores were similar to the normal-hearing scores for that condition (up to seven channels). CI listeners with the highest performance level increased in performance as the number of electrodes increased up to seven, while CI listeners with low levels of speech recognition did not increase in performance as the number of electrodes was increased beyond four. These results quantify the effect of number of spectral channels on speech recognition in noise and demonstrate that most CI subjects are not able to fully utilize the spectral information provided by the number of electrodes used in their implant.

Adult↗

Coding of sounds in the auditory system and its relevance to signal processing and coding in cochlear implants.

OBJECTIVE: To review how the properties of sounds are "coded" in the normal auditory system and to discuss the extent to which cochlear implants can and do represent these codes. DATA SOURCES: Data are taken from published studies of the response of the cochlea and auditory nerve to simple and complex stimuli, in both the normal and the electrically stimulated ear. REVIEW CONTENT: The review describes: 1) the coding in the normal auditory system of overall level (which partly determines perceived loudness), spectral shape (which partly determines perceived timbre and the identity of speech sounds), periodicity (which partly determines pitch), and sound location; 2) the role of the active mechanism in the cochlea, and particularly the fast-acting compression associated with that mechanism; 3) the neural response patterns evoked by cochlear implants; and 4) how the response patterns evoked by implants differ from those observed in the normal auditory system in response to sound. A series of specific issues is then discussed, including: 1) how to compensate for the loss of cochlear compression; 2) the effective number of independent channels in a normal ear and in cochlear implantees; 3) the importance of independence of responses across neurons; 4) the stochastic nature of normal neural responses; 5) the possible role of across-channel coincidence detection; and 6) potential benefits of binaural implantation. CONCLUSIONS: Current cochlear implants do not adequately reproduce several aspects of the neural coding of sound in the normal auditory system. Improved electrode arrays and coding systems may lead to improved coding and, it is hoped, to better performance.

Cochlea↗

Understanding speech in modulated interference: cochlear implant users and normal-hearing listeners.

Many competing noises in real environments are modulated or fluctuating in level. Listeners with normal hearing are able to take advantage of temporal gaps in fluctuating maskers. Listeners with sensorineural hearing loss show less benefit from modulated maskers. Cochlear implant users may be more adversely affected by modulated maskers because of their limited spectral resolution and by their reliance on envelope-based signal-processing strategies of implant processors. The current study evaluated cochlear implant users' ability to understand sentences in the presence of modulated speech-shaped noise. Normal-hearing listeners served as a comparison group. Listeners repeated IEEE sentences in quiet, steady noise, and modulated noise maskers. Maskers were presented at varying signal-to-noise ratios (SNRs) at six modulation rates varying from 1 to 32 Hz. Results suggested that normal-hearing listeners obtain significant release from masking from modulated maskers, especially at 8-Hz masker modulation frequency. In contrast, cochlear implant users experience very little release from masking from modulated maskers. The data suggest, in fact, that they may show negative effects of modulated maskers at syllabic modulation rates (2-4 Hz). Similar patterns of results were obtained from implant listeners using three different devices with different speech-processor strategies. The lack of release from masking occurs in implant listeners independent of their device characteristics, and may be attributable to the nature of implant processing strategies and/or the lack of spectral detail in processed stimuli.

Adult↗

Management of cerebrospinal fluid leakage from cochleostomy during cochlear implant surgery.

OBJECTIVES: The objectives of this retrospective review were to determine the incidence of cerebrospinal fluid (CSF) otorrhea from the cochleostomy during cochlear implant surgery, to recognize patients at risk, and to determine the appropriate preoperative, postoperative and intraoperative management. METHODS: A chart review from two cochlear implant centers was performed to determine the incidence of CSF otorrhea, patients at risk, and appropriate management. RESULTS: The incidence of CSF gusher is low, encountered in approximately 1% of patients undergoing cochlear implant surgery, and is seen in equal incidence in children and adults in our series. Preoperative imaging was predictive in only 50% of cases. Mechanisms for otorrhea in specific cochlear malformations and in those in which no apparent malformation exists are discussed. Successful implantation is expected in most cases. Intraoperative management may require complete packing of the middle ear space in addition to the cochleostomy to control CSF leak. Lumbar drain is rarely necessary. Outpatient management is possible in the majority of cases. Vaccination and antibiotic prophylaxis is essential. CONCLUSIONS: CSF otorrhea can be encountered in cochlear malformations and in cochleas without apparent malformation. Successful implantation without short-term or long-term complications is expected.

Adolescent↗

Vowel and diphthong production by young users of cochlear implants and the relationship between the phonetic level evaluation and spontaneous speech.

This investigation assessed how the vowel and diphthong production of young users of cochlear implants varied over time and how performance on the Phonetic Level Evaluation (PLE, Ling, 1976) corresponded with vowel and diphthong production during spontaneous speech. Eight children with prelingual deafness were tested with the PLE on five occasions: before receiving a Cochlear Corporation Nucleus cochlear implant and at the following points after receiving a cochlear implant: 6 months, 12 months, 18 months, and 24 or 36 months. An audiovideo recording of spontaneous speech was obtained at each test session. Performance on the PLE was scored with the scoring system designed by Kirk and Hill-Brown (1985). Performance during spontaneous speaking was scored by referencing a transcription of the spoken message to a transcription of the signed message. The correlations between the PLE and the spontaneous speech measures were weak, suggesting that performance on the PLE has low predictive value for vowel and diphthong production during spontaneous speaking. The results from the spontaneous speech samples collected over time suggest that two changes occurred: (a) vowel and diphthong production became more diverse and (b) production became more accurate. It is suggested that increased access to formant information enables subjects to enlarge their system of phonological performance and refine their motoric ability to establish vowel and diphthong targets.

Child↗

Reoperations after cochlear implantation.

During the 14-year history of cochlear implantation at Semmelweis University, 95 implantations were performed. There were 15 reoperations, and 2 patients had been operated 3 times. All of the reoperated patients received round window or intracochlear MedE1 devices. Successful reinsertion of the electrode was performed without significant difficulty, though in some cases osteoneogenesis was found in the round window or in the scala tympani. None of the patients suffered any inner ear abnormalities due to the first implant, and even the patient with a third implant in the same ear had excellent results and obtained better discrimination scores with the new device. In the authors' opinion, on the basis of the accumulated experience of nearly 100 implantations and 15 reoperations, replacement of the early generation extracochlear implants is most advisable and can be accomplished without adverse effects.

Cochlear Implantation↗

Acoustic change complexes recorded in adult cochlear implant listeners.

OBJECTIVES: The objectives of this study were to determine: 1) whether the acoustic change complex (ACC) could be reliably recorded in cochlear implant listeners and, 2) whether different speech sounds evoke distinct ACC patterns. DESIGN: Eight adults wearing the Nucleus-24 cochlear implant (CI) were tested using naturally produced speech tokens /si/ and /i/. Stimuli were tokens from the standardized UCLA version of the Nonsense Syllable Test. Using a repeated-measures design, participants were tested and retested within a 3-wk period. RESULTS: Intraclass correlation coefficients for grand mean and individual-response waveforms recorded from the syllables /si/ and /i/ ranged from 0.63 to 0.89 from test to retest. Also, ACC latencies signaling the onset of a vowel in /i/ were significantly earlier than those evoked by /si/. CONCLUSIONS: The ACC can be reliably recorded in individuals wearing CI. Furthermore, the naturally produced speech syllables /si/ and /i/ evoke distinct ACC patterns. Because of its good stability and the ease with which it can be recorded in individual CI listeners, the ACC can be evoked using complex signals (such as naturally produced speech syllables) when studying central auditory function in CI listeners.

Acoustic Stimulation↗

Prelexical vocalization in normal hearing and hearing-impaired infants before and after cochlear implantation and its relation to early auditory skills.

OBJECTIVES: To compare the vocalizations of hearing-impaired infants before and after cochlear implantation with those of a control group of hearing infants and to relate prelexical vocalizations by using the PRoduction Infant Scale Evaluation (PRISE) to early auditory skill attainments, using the Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) in normal-hearing and hearing-impaired (HI) infants before and after cochlear implantation. DESIGN: A total of 187 infants participated in the study: 24 HI infants with severe-profound hearing loss (8 to 23 months of age) and 163 hearing infants (0.5 to 20 months of age). Prelexical vocalizations and early auditory skills were assessed by using parent questionnaires (PRISE and IT-MAIS, respectively) that reflect known milestones in the infant's vocal and auditory development. HI infant data were compared with hearing infant data according to chronological age and duration of device use (hearing aid or cochlear implant). RESULTS: Average PRISE score of aided HI infants before implantation was 50% or less (regardless of age). This score is comparable to that of hearing infants who are 6 to 7 months of age. After implantation, HI infants reached a score of 70% but did not reach normative performance. When HI infant data were compared with hearing infants by duration of device use, aided infants before implantation performed as well or worse than normative performance, whereas implanted infants performed as well as or better than hearing infants. Performance on individual PRISE questions showed limited ability by HI infants before implantation compared with hearing and implanted infants. A strong correlation was found between the IT-MAIS and the PRISE (r = 0.93 and r = 0.83, for hearing and HI infants, respectively). CONCLUSIONS: The PRISE was found to be a versatile tool for implant team clinicians who are required to assess prelinguistic skills of infants. The findings suggest that early auditory skills are related to prelexical vocalization. The data also highlighted unanswered questions related to the importance of early fitting of hearing aids on vocalization before and after implantation.

Auditory Perception↗

Adult cochlear implant patient performance with evolving electrode technology.

OBJECTIVE: In 1998, clinical trials were initiated to evaluate the CLARION Multi-Strategy Cochlear Implant (Advanced Bionics Corp., Sylmar, CA, U.S.A.), a precurved electrode with an electrode positioning system (EPS) in adults with severe to profound hearing impairments. In 1999, clinical trials were initiated to assess the CLARION HiFocus electrode with EPS in a similar group of adults. The purpose of this retrospective study was to evaluate and compare the preoperative and 1-, 3-, and 6-month postoperative speech perception scores obtained by the first 56 patients implanted with the precurved electrode with EPS and the first 56 patients implanted with the HiFocus electrode with EPS. Speech strategy preferences were additionally noted and compared at each test interval for each group. STUDY DESIGN: All subjects participated in preoperative testing with hearing aids and postoperative (1, 3 and 6 months) testing with either the precurved electrode with EPS or the HiFocus electrode with EPS. Demographic characteristics and preoperative and postoperative speech perception results were compared within and between the 2 groups. SETTING: Data presented here were collected at cochlear implant programs affiliated with tertiary medical centers located in the United States and Canada that participated in the clinical trials. PATIENTS: Patients were postlinguistically deafened adults who received a CLARION cochlear implant. RESULTS AND CONCLUSION: Within-group evaluations revealed that both groups demonstrated significant improvements on all speech perception measures when 1-month postoperative scores were compared with scores obtained preoperatively with hearing aids. Between-group comparison of demographic data showed that the HiFocus group had a significantly higher mean age at implant and a significantly longer mean duration of deafness than the precurved electrode with EPS group. Statistical comparison of mean speech perception scores showed no significant difference between subjects using the precurved electrode with EPS versus the HiFocus electrode with EPS at the preoperative, 1-, and 3-month test intervals. At the 6-month test interval, the mean CNC Monosyllabic Word Test score obtained by the HiFocus with EPS group was significantly better than the mean score obtained by the group with the precurved electrode with EPS (p < 0.05).

Audiometry↗