Molecular imaging using a targeted magnetic resonance hyperpolarized biosensor.

A magnetic resonance approach is presented that enables high-sensitivity, high-contrast molecular imaging by exploiting xenon biosensors. These sensors link xenon atoms to specific biomolecular targets, coupling the high sensitivity of hyperpolarized nuclei with the specificity of biochemical interactions. We demonstrated spatial resolution of a specific target protein in vitro at micromolar concentration, with a readout scheme that reduces the required acquisition time by >3300-fold relative to direct detection. This technique uses the signal of free hyperpolarized xenon to dramatically amplify the sensor signal via chemical exchange saturation transfer (CEST). Because it is approximately 10,000 times more sensitive than previous CEST methods and other molecular magnetic resonance imaging techniques, it marks a critical step toward the application of xenon biosensors as selective contrast agents in biomedical applications.

Avidin↗

Use of an oxygen-insensitive microscale biosensor for methane to measure methane concentration profiles in a rice paddy.

An oxygen-insensitive microscale biosensor for methane was constructed by furnishing a previously described biosensor with an oxygen guard. The guard consisted of a glass capillary containing heterotrophic bacteria, which consumed oxygen diffusing through the tip membrane, thus preventing it from diffusing into the methane-sensing unit. Oxygen microprofiles were measured through the oxygen guard capillary, demonstrating the principle and limitations of the method. When the tip of the guard capillary was exposed to 100% oxygen at 21 degrees C, heterotrophic oxygen consumption prevented oxygen from diffusing further than 170 mum into the capillary, whereas atmospheric levels of oxygen were consumed within 50 mum. The capacity of the oxygen guard for scavenging oxygen decreased with decreasing temperature, and atmospheric levels of oxygen caused oxygen penetration to 200 mum at 5 degrees C. The sensors could be manufactured with tip diameters as small as 25 mum, and response times were about 1 min at room temperature. Pore water profiles of methane concentrations in a rice paddy soil were measured, and a strong correlation between the depths of oxygen penetration and methane appearance was observed as a function of the light regimen; this finding confirmed the role of microbenthic photosynthesis in limiting methane emissions from surfaces of waterlogged sediments and soils.

Journal Article↗

Microscale biosensor for measurement of volatile fatty acids in anoxic environments.

A microscale biosensor for acetate, propionate, isobutyrate, and lactate is described. The sensor is based on the bacterial respiration of low-molecular-weight, negatively charged species with a concomitant reduction of NO(-)(3) to N(2)O. A culture of denitrifying bacteria deficient in N(2)O reductase was immobilized in front of the tip of an electrochemical N(2)O microsensor. The bacteria were separated from the outside environment by an ion-permeable membrane and supplied with nutrients (except for electron donors) from a medium reservoir behind the N(2)O sensor. The signal of the sensor, which corresponded to the rate of N(2)O production, was proportional to the supply of the electron donor to the bacterial mass. The selectivity for volatile fatty acids compared to other organic compounds was increased by selectively enhancing the transport of negatively charged compounds into the sensor by electrophoretic migration (electrophoretic sensitivity control). The sensor was susceptible to interference from O(2), N(2)O, NO(2)(-), H(2)S, and NO(-)(3). Interference from NO(-)(3) was low and could be quantified and accounted for. The detection limit was equivalent to about 1 microM acetate, and the 90% response time was 30 to 90 s. The response of the sensor was not affected by changes in pH between 5.5 and 9 and was also unaffected by changes in salinity in the range of 2 to 32 per thousand. The functioning of the sensor over a temperature span of 7 to 30 degrees C was investigated. The concentration range for a linear response was increased five times by increasing the temperature from 7 to 19.5 degrees C. The life span of the biosensor varied between 1 and 3 weeks after manufacturing.

Anaerobiosis↗

Construction of a ColD cda promoter-based SOS-green fluorescent protein whole-cell biosensor with higher sensitivity toward genotoxic compounds than constructs based on recA, umuDC, or sulA promoters.

Four different green fluorescent protein (GFP)-based whole-cell biosensors were created based on the DNA damage inducible SOS response of Escherichia coli in order to evaluate the sensitivity of individual SOS promoters toward genotoxic substances. Treatment with the known carcinogen N-methyl-N'-nitro-N-nitrosoguanidine (MNNG) revealed that the promoter for the ColD plasmid-borne cda gene had responses 12, 5, and 3 times greater than the recA, sulA, and umuDC promoters, respectively, and also considerably higher sensitivity. Furthermore, we showed that when the SOS-GFP construct was introduced into an E. coli host deficient in the tolC gene, the minimal detection limits toward mitomycin C, MNNG, nalidixic acid, and formaldehyde were lowered to 9.1 nM, 0.16 microM, 1.1 microM, and 141 microM, respectively, which were two to six times lower than those in the wild-type strain. This study thus presents a new SOS-GFP whole-cell biosensor which is not only able to detect minute levels of genotoxins but, due to its use of the green fluorescent protein, also a reporter system which should be applicable in high-throughput screening assays as well as a wide variety of in situ detection studies.

Base Sequence↗

Quantifying serum antiplague antibody with a fiber-optic biosensor.

The fiber-optic biosensor, originally developed to detect hazardous biological agents such as protein toxins or bacterial cells, has been utilized to quantify the concentration of serum antiplague antibodies. This biosensor has been used to detect and quantify the plague fraction 1 antigen in serum, plasma, and whole-blood samples, but its ability to quantify serum antibodies has not been demonstrated. By using a competitive assay, the concentration of serum antiplague antibodies was ascertained in the range of 2 to 15 microgram/ml. By making simple dilutions, concentrations for 11 serum samples whose antiplague antibody concentrations were unknown were determined and were found to be in good agreement with enzyme-linked immunosorbent assay results. The competitive assay method could be used to effectively determine the exposure to plague of animals or humans or could be applied to other diseases, such as hepatitis or AIDS, where the presence of antibodies is used to diagnose infection.

Animals↗

Biosensors for the detection of bacteria.

This review will consider the role of biosensors towards the detection of infectious bacteria, although non-infectious ones will be considered where necessary. Recently, there has been a heightened interest in developing rapid and reliable methods of detection. This is especially true for detection of organisms involved in bioterrorism, food poisoning, and clinical problems such as antibiotic resistance. Biosensors can assist in achieving these goals, and sensors using several of the different types of transduction modes are discussed: electrochemical, high frequency (surface acoustic wave), and optical. The paper concludes with a discussion of three areas that may make a great impact in the next few years: integrated (lab-on-a-chip) systems, molecular beacons, and aptamers.

Bacteria↗

Fluorescent protein biosensors: measurement of molecular dynamics in living cells.

A new generation of reagents that report on specific molecular events in living cells, called fluorescent protein biosensors, has evolved from in vitro fluorescence spectroscopy and fluorescent analogue cytochemistry. Creative designs of fluorescent protein biosensors to measure the molecular dynamics of macromolecules, metabolites, and ions in single cells emerge from the integrative use of contemporary synthetic organic chemistry, biochemistry, and molecular biology. Future advances in fluorescent probe design, computer-driven optical instrumentation, and software will allow us to engineer endogenous cellular components that localize and function as reporters of their activities, thus moving molecular measurement beyond the single cell to living tissues and the whole organism.

Biosensing Techniques↗

Urea biosensors and their application in hemodialysis--perspective of EnFET application.

Parameters such as blood urea nitrogen concentration, normalized protein catabolic rate and Kt/V that are utilized for urea concentration measurements in blood and dialysate for the optimization of the hemodialysis process are reviewed in the paper. Basic methods of urea concentration measurement are described. Urea biosensors of the EnFET type based on the pH-sensitive Si3N4 gate FET and pNH4-sensitive FET with a Siloprene membrane containing nonactine, both of our own construction, are presented. Application of these biosensors for urea concentration measurement in blood and dialysate is described. An experimental microdialysis system with urease in detector solution and a pH-ISFET detector are described. A comparison of two dialysis procedures, with a commercial dialysate an initial of pH 5.6 and with pH kept lowered during the dialysis process applied to rats, is given.

Animals↗

Development of organic dye-doped silica nanoparticles for bioanalysis and biosensors.

The combination of two silica precursors, tetraethylorthosilicate and phenyltriethoxysilane, were utilized to synthesize organic dye-doped silica nanoparticles. The hydrophobic nature of phenyltriethoxysilane keeps the organic dye in the silica matrix, whereas the hydrophilic tetraethylorthosilicate-formed silica allows the resulting nanoparticles to be dispersed in aqueous solutions. Characterization of the nanoparticles showed that they could be synthesized in the nanometer range with high photostability and minimal dye leakage. The silica matrix of the nanoparticles allows different routes of surface biomolecular modification for biosensor and bioanalysis applications. We have shown different applications of the nanoparticles in bioanalysis and in biosensing. Biotin interaction of avidin-coated nanoparticles can be used for the determination of biotinylated bovine serum albumin, and the immobilization of glutamate dehydrogenase on the nanoparticle surfaces enables the nanoparticles to be used as biosensors for glutamate determination.

Biosensing Techniques↗

Performance of an amperometric biosensor for the determination of hemoglobin.

Hemoglobin is a very important physiological index in human blood, especially for the evaluation of the physical performance of athletes. This paper reports an amperometric biosensor for the determination of blood hemoglobin, using potassium ferricyanide as a mediator, based on thin-film technology in a two-electrode system. The biosensor can be used for the determination of hemoglobin at concentrations in a linear range of 10-3000 microM, and the correlation coefficient is 0.996, the relative standard deviation is 2.3% for six determinations for 2000 microM hemoglobin concentration. And the linear range of hemoglobin is studied using methylene blue as a mediator.

Biosensing Techniques↗

Precision, accuracy and linearity of radiometer EML 105 whole blood metabolite biosensors.

The analytical performance of a new, whole blood glucose and lactate electrode system (EML 105 analyser. Radiometer Medical A/S. Copenhagen, Denmark) was evaluated. Between-day coefficients of variation were < or = 1.9% and < or = 3.1% for glucose and lactate, respectively. Recoveries of glucose were 100 +/- 10% using either aqueous or protein-based standards. Recoveries of lactate depended on the matrix, being underestimated in aqueous standards (approximately -10%) and 95-100% in standards containing 40 g/L albumin at lactate concentrations of 15 and 30 mmol/L. However, recoveries were high (up to 180%) at low lactate concentrations in protein-based standards. Carry-over, investigated according to National Clinical Chemistry Laboratory Standards EP10-T2, was negligible (alpha = 0.01). Glucose and lactate biosensors equipped with new membranes were linear up to 60 and 30 mmol/L, respectively. However, linearity fell upon daily use with increasing membrane lifetime. We conclude that the Radiometer metabolite biosensor results are reproducible and do not suffer from specimen-related carry-over. However, lactate recovery depends on the protein content and the lactate concentration.

Biosensing Techniques↗

Chemical sensors and biosensors for fluoride: current status and developing technologies.

Portable sensors for bioanalytes are becoming of increasing interest, because their development will permit analyses of biological samples at the point of sampling, i.e., at the time when an individual is being examined by a health professional. In this paper, the design requirements for a fluoride sensor are outlined. Currently, commercially available fluoride sensors, ion-selective electrodes, do provide the capability to measure fluoride content in samples directly. However, the sensitivity of these devices is lower than the normal content of fluoride in plasma, and thus, samples must be concentrated before measurement. Recent progress in improving the sensitivity of chemical sensors for fluoride shows sensitivities up to 0.1 mumol/L, which is within the range of interest. In addition, the use of biological systems for developing sensors (biosensors) is expanding rapidly, because of the potential of achieving high selectivity and sensitivity through the use of the amplification power of enzymes. However, relatively few enzyme systems have been discovered that are affected by fluoride--thus the need for expanded research to find appropriate enzymes for this purpose. The characteristics of some enzymes, such as adenylate cyclase, that could be used in the development of a fluoride biosensor are discussed.

Biosensing Techniques↗

Biosensor-based screening and characterization of HIV-1 inhibitor interactions with Sap 1, Sap 2, and Sap 3 from Candida albicans.

A surface plasmon resonance (SPR) biosensor-based strategy for identification and characterization of compounds has been devised as a tool for the discovery of specific drugs for treatment of Candida albicans infections. Three secreted aspartic proteases (Saps 1-3) from C. albicans were used as parallel targets. The stepwise procedure involved screening of 104 HIV-1 pro-tease inhibitors at a single concentration for binding to the targets. Twenty-four compounds that appeared to interact with the targets were identified in the screen. False positives and compounds with low affinities or very fast dissociation rates could be removed after a series of additional measurements of these compounds at 3 different concentrations. Kinetic characterization was performed with 13 compounds, giving information about the interaction mechanism and interaction kinetic parameters (k(on), k(off), and K(D)). The pH dependence of the interaction and the inhibitory effect of a final small set of compounds were also evaluated. The strategy resulted in the identification of ritonavir as the compound generally exhibiting the highest affinity for the Candida enzymes. It had similar interaction kinetic characteristics for Sap 1 and Sap 2 but a lower affinity for Sap 3 due to a slower association rate. Several additional compounds with high affinity and/or slow dissociation rates for the targets were identified, revealing 2 other structural scaffolds for Sap inhibitors. In addition, important differences in the specificity for these types of compounds by the Saps were identified. The stepwise biosensor-based strategy was consequently efficient for identification and characterization of new lead compounds for 3 important drug targets.

Aspartic Acid Endopeptidases↗

Binding properties of insulin-like growth factor binding protein-3 (IGFBP-3), IGFBP-3 N- and C-terminal fragments, and structurally related proteins mac25 and connective tissue growth factor measured using a biosensor.

We measured the binding of IGF-I and IGF-II to recombinant human N-terminal [residues 1-97; recombinant human IGF-binding protein-3(1-97) (rhIGFBP-3(1-97))] and C-terminal (residues 98-264; rhIGFBP-3(98-264)) IGFBP-3 fragments and compared it with IGF binding to intact IGFBP-3 using biosensor analysis. Experiments were carried out in different configurations, either with binding protein or fragment immobilized or with IGF immobilized. These experiments showed that IGF-I and IGF-II bind to IGFBP-3 with affinities of 4-5 x 10(9) M(-1) and similar binding kinetics. The affinities of both rhIGFBP-3(1-97) and rhIGFBP-3(98-264) for IGF proteins were approximately 3 orders of magnitude less than that of full-length IGFBP-3. These results further support the concept that high affinity binding of IGF to IGF-binding proteins results from a two-site interaction of IGF with both the N- and C-terminal regions of the binding protein. Binding of insulin to IGFBP-3 and its N- and C-terminal fragments and of IGF-I and IGF-II to the structurally related proteins mac25 and connective tissue growth factor was also investigated. Weak insulin binding to full-length IGFBP-3 could be demonstrated in a few experiments, but we found that binding of IGF-I, IGF-II, and insulin to mac25 or connective tissue growth factor was below the detection limit of the biosensor instrument.

Biosensing Techniques↗

A surface plasmon resonance biosensor assay for measurement of anti-GM(1) antibodies in neuropathy.

OBJECTIVE: To develop a rapid assay for the detection and measurement of anti-GM(1) ganglioside antibodies in patients with neuropathy, using a surface plasmon resonance-based biosensor. BACKGROUND: Elevated levels of anti-GM(1) ganglioside antibodies are observed in patients with acute and chronic motor neuropathies. Assays for detecting anti-GM(1) antibodies in serum are increasingly being used to help the physician in the evaluation of these patients. METHODS: Antigens were immobilized by adsorption of GM(1) (active) and GM(2) (control) gangliosides onto a dextran-based sensor chip which is in contact with a flow cell carrying the sample. Interaction of specific antibodies directed against GM(1) with the ganglioside-coated sensor chip caused a change in refractive index at the surface of the chip, which was detected by an optical sensor, using the phenomenon of surface plasmon resonance. Sera from patients and healthy individuals were analyzed by the new assay and results were compared with those from ELISA. Anti-GM(1) antibody isotype was identified by using a secondary antibody. RESULTS: The binding of anti-GM(1) antibodies to the immobilized GM(1) was observed in real time after reference subtraction of the response from GM(2) control. The response was proportional to antibody concentration. The assay exhibited high specificity for sera from patients with multifocal motor neuropathy and Guillain-Barré syndrome with antibodies against GM(1). CONCLUSIONS: The surface plasmon resonance biosensor assay offers a rapid system for directly measuring antibody levels in serum without the use of any labels, while comparing favorably with the ELISA system in sensitivity and specificity.

Antibodies, Anti-Idiotypic↗

Glucose and lactate biosensors prepared by a layer-by-layer deposition of concanavalin A and mannose-labeled enzymes: electrochemical response in the presence of electron mediators.

An electrochemical response of glucose and lactate biosensors which were prepared by coating a platinum electrode with a thin film composed of concanavalin A and mannose-labeled glucose oxidase (GOx) or lactate oxidase (LOx) was evaluated in the presence of ferrocene derivatives as electron mediator. Both glucose and lactate biosensors showed catalytic current to glucose and lactate, respectively, in cyclic voltammetry, suggesting that the ferrocene derivatives can mediate electron transport smoothly from the reduced forms of GOx and LOx in the thin films to the electrode. Among the three kinds of ferrocene derivatives used, ferrocenylmethanol was found to be the most suitable electron mediator because of its low oxidation potential. The glucose and lactate sensors gave useful calibration graphs, in which higher detection limits were reached as compared with those observed when the sensors were operated in the absence of electron mediator.

Biosensing Techniques↗

Quantitative estimation of interaction between carbohydrates and concanavalin A by surface plasmon resonance biosensor.

We measured the affinity of more than 20 sugars with concanavalin A (ConA) by an optical biosensor (surface plasmon resonance sensor) using asialofetuin (ASF) as an immobilized binding partner of ConA. We determined kinetic parameters of the effects of sugars on the dissociation of ConA from ASF quantitatively, and the structural requirements of the functional groups of sugars for binding with ConA. We found that the affinity of ConA for sugars is dependent on its conformation induced by interaction with the binding partner. In addition, the results showed that optical biosensor system is well mimics the interaction of ConA with sugars in biomembrane.

Animals↗

An electrochemical approach to the studies of biological redox reactions and their applications to biosensors, bioreactors, and biofuel cells.

Enzymatic redox reactions for the oxidation (or reduction) of the substrates use organic dyes or metal complexes as electron acceptors (or donors), which can be regenerated by electrochemical reactions of the compounds at an electrode surface. This type of coupling of the enzymatic reactions with the electrochemical reactions is called bioelectrocatalysis and allows us to measure the enzymatic reactions by an electrochemical method. The enzyme-electrochemical method provides a new technique for investigating a variety of biological redox reactions and for applying the reactions to biosensors, bioreactors, and biofuel cells. The bioelectrocatalysis-based research works are described here. First, a new method of protein redox potential measurements and a novel electrochemical kinetic analysis of oxidoreductase reactions are described. Second, a new methodology of characterizing microbial catalytic activities is presented. In the last, applications to the constructions of biosensors, bioreactors, and biofuel cells are mentioned.

Journal Article↗