PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Nomogram”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74Linked to original sources

Evaluation and interpretation of grain density autoradiographs by reflectance photometry.

The tritium content of nervous tissue sections is calculated from grain-density of autoradiograph without loss in anatomical information. The calculation is not based on determination of (expected) grain numbers but on photometric measurements (SKphot), interpreted as the result of the function of exposure time (T) and incorporated activity (beta): SKphot = f(T, beta). As experimental radiation standards homologous material (optic nerve preparations) with different activities determined by liquid scintillation counting has been used. Exposure times between 12 h and 28 weeks for these preparations with known radioactivities yielded a set of curves (nomogram) relating photometric values of exposure times. At any given exposure time the knowledge of photometric readings and related radioactivities within that set of curves enabled the development of a function covering all photometer readings within the range of the nomogram. Thus, any photometric reading could be correlated to the corresponding radioactivity. Such a function has been applied for the transformation of photometric values obtained from particular brain-section areas exposed for 16 weeks. Since the results are given in Bq, they may be related and, if necessary, corrected to results obtained by other tritium detection methods. Terminology used in the text: experimental radiation source = experimental standards prepared from optic nerve sections; standard radiation source = polymer reference source.

Animals↗

Clinical evaluation of high-frequency positive-pressure ventilation (HFPPV) in laryngoscoy under general anaesthesia.

A technique for automatic ventilation during laryngoscopy under general anaesthesia was evaluated in a lung model and in 5 patients (3--57 y) submitted for routine laryngoscopy. this technique has been given the name laryngoscopic HFPPV and utilizes an insufflation frequency (f) of 60 per min and a relative insufflation time (t%) of 22%. Ventilation is given via a nasotracheal insufflation catheter. Laryngoscopic HFPPV permits laryngeal surgery with a virtually unobstructed surgical field under complete muscular relaxation. The alveolar ventilation of the patient may be controlled by adjustment of the pressure of the anaesthetic gas mixture and there is no air entrainment through the larynx during insufflation. This makes possible use of O2/N2O mixtures and the oxygenation of the patient may be controlled by adjustment of the oxygen concentration of the anaesthetic gas mixture. As there is a continuous upward has flow through the larynx, blood or pieces of loose tissue are not sucked down into the trachea. A simple ventilation nomogram for clinical use is proposed. Adequately used, this nomogram guarantees safe ventilation during laryngoscopic HFPPV. An Fio2 of 0.3--0.4 gives adequate arterial oxygenation.

Anesthesia, General↗

Predicted normocapnea in infants and children using the Bain circuit with controlled ventilation.

We have constructed a nomogram for fresh gas flow (VFG) and minute ventilation (VE) for paediatric anaesthesia during controlled ventilation using the Bain coaxial Mapleson D circuit. VFG was based upon the assumption of a high fresh gas utilization because of a low VFG/VE ratio (0.67) and known figures of carbon dioxide elimination. The formulas VFG = 27.8 x VCO2 and VE = 1.5 x VFG were used to calculate the necessary flows to generate normocapnea. The nomogram was evaluated in 59 children (6-62 kg, age 5 months-14 years). PaCO2 (mean +/- s.d.) was 5.0 +/- 0.5 kPa (38 +/- 4 mmHg) with a total range of 3.9-6.3 kPa (29-47 mmHg). Ninety percent of the children had a PaCO2 of 5.7 kPa (43 mmHg) or lower. There was no correlation between body weight and PaCO2. Hence, there was no difference in mean values between children below or above a body weight of 20 kg.

Adolescent↗

A pilot study evaluating a new questionnaire for prostatic symptom scoring, the SPSS, and its sensitivity as constructed to objective measures of outflow obstruction.

AIM: To evaluate the extent to which our newly developed questionnaire, the Saitama Prostate Symptom Score (SPSS), for prostatic symptom scoring reflects objective findings in benign prostatic hyperplasia (clinical BPH) and to compare it with the International Prostate Symptom Score (IPSS) with regard to diagnostic sensitivity in clinical BPH. METHODS: In this study, both the SPSS and the IPSS were self-administered by patients. Free uroflowmetry, a pressure-flow study and the measurement of prostatic volume were carried out. RESULTS: There was no significant correlation between the results of the IPSS questionnaire and the urethral obstruction grade estimated by Schaefer or Abrams-Griffiths nomograms. The total score of the SPSS was correlated with these nomograms (P = 0.0487 and P = 0.0413, respectively). There was no significant correlation between the results of the IPSS questionnaire and the total volume or transition zone volume of the prostate, whereas the total score of the SPSS correlated with the total volume of the gland and transition zone volume (P = 0.0044 and P= 0.0051, respectively). CONCLUSION: This study revealed the SPSS to correlate with objective findings satisfactorily. However, there are still several aspects of the SPSS which need to be improved upon, and the questionnaire should be studied in larger numbers of patients suffering from lower urinary tract symptoms.

Aged↗

Spirometric values for normal Perth children aged six to twelve years.

The purpose of this study was to construct tables and nomograms of spirometric norms for Perth children aged between six and 12 years. These norms were to be based on anthropometric measurements and age. A sample of 623 children was tested of which 556 were analysed and comprised 289 boys and 267 girls. All testing was carried out in the child's own school. The spirograms were recorded with a dry spirometer from which the FVC, FEV1, and FMF were measured. Correlation coefficients were established between each of these ventilatory parameters and anthropometric measurements of height, mass, arm span and age. The findings of the study revealed high correlations for both boys and girls between ventilatory parameters of FVC and FEV1 and height, mass, arm span and age. Moderately high correlations were found for both sexes between FMF and height, mass, arm span and age. Height correlated best with each of these ventilatory measures. It was also established that significant improvement in some correlations was obtained when anthropometric values were used in multiple correlation analysis. The use of height plus mass proved to be best when predicting FVC and FEV, for boys and girls, and for predicting FMF of girls. FMF for boys could be best predicted by using height alone. The limits of normality for ventilatory parameters of FVC, FEV1 and FMF were found to be best defined by the per cent standard error of the estimate. Tables and nomograms were established from regression and multiple regression equations in order to predict normal values in children. The findings of this study revealed that little difference existed between the ventilatory values of children tested in Perth, Europe and the Eastern States of Australia. However, the differences that were found to exist could be due to the age group which was sampled or possible environmental and genetic differences.

Age Factors↗

How reliable is a single measurement of urinary flow in the diagnosis of obstruction in benign prostatic hyperplasia?

Twenty-six elderly patients with obstructive symptomatology and an initial low peak urinary flow rate (< 15 ml/s) were observed for 6 to 12 months. Repeated assessments were made of flow rates and residual volumes. Within patients variation of the maximal urinary flow was significant; the standard deviation (SD) varied from 0.8 to 5.5 ml/s. The SD varied with the mean peak flow rates and this suggests that the precision of a single determination of a patient's peak flow is inversely related to the peak flow itself. In all, 333 determinations of peak flow were obtained. Only 80% were below 2 SD of the mean Siroky nomogram. Multiple determinations were used to estimate the sensitivity rate for each patient, i.e. the proportion of peak flows that were less than 2 SD below the mean of Siroky's nomogram. The average sensitivity for all of the flow values was 0.813 when applied to voided volumes and increased only slightly to 0.838 when applied to total bladder volume. Given a prevalence of 0.70 of obstruction ascribed to benign prostatic hyperplasia (BPH) among elderly men, the positive predictive value of an abnormally low peak flow was 0.97. A single low peak flow based on assessment of voided volume may serve as an almost sure indication of obstruction. If a patient has a single normal peak flow rate, he still has a 0.31 probability of having evidence of obstruction in his following uroflow determinations. Using total bladder volume does not make a difference in most patients and is not worth the effort and discomfort. The only patients who require accurate residual measurements are those with a normal uroflow but clear-cut obstructive symptomatology or with borderline peak flow. The results of this study are relevant to everyday clinical practice and to the evaluation of studies on alternatives to surgery in BPH.

Aged↗

Longitudinal observations on normal and abnormal voiding in men over the age of 50 years.

A cohort of 200 men over the age of 50 years was selected at random. Initially 112 men participated. After 5 years 61 were participating, and 2 years later 34 men still had no voiding problems, while 19 had had treatment for prostatism. A history was obtained and all 112 had symptom analysis and uroflow examination. The uroflow variables Qmax, Qave, Qmax-time, Q "corrected", volume and the ratio Qmax/Qmax-time were recorded together with the symptom score and subjective evaluation. After 5 and 7 years all primary data were reviewed in the 61 and 34 men respectively, while a full history was obtained in the rest. The 3 sets of data were evaluated separately as 3 cross-sectional investigations and as paired data sets by means of non-parametrical statistical analysis. Comparing the 3 sets of data longitudinally, significant differences were found in Qmax, Qave, Qcor and Acc. A correlation analysis showed that Qmax, Qave, Q "corrected" and volume decreases significantly with advancing age in asymptomatic men, while no correlation with age was found in the 19 treated men. On the basis of the 93 men, untreated for 7 years, nomograms of Qmax, Volume and Acc were constructed using 2.5, 25, 50, 75 and 97.5% percentiles in 5-year groups. Likewise, a nomogram on symptom score was constructed on the basis of the 82 men, asymptomatic and untreated for 7 years. In conclusion, uroflow in subjectively normal men over the age of 50 years shows increasing abnormality with advancing age. At the same time elderly men tolerate a considerable amount of symptoms of infravesical obstruction. The severity of symptoms increased with advancing age, but differently in persons likely and not likely to need operation.

Aged↗

Standard Kt/V: comparison of calculation methods.

Standard Kt/V (stdKt/V) makes possible the comparison of the dialytic efficiency of different therapies, with different frequencies, whether intermittent, continuous or a mixture of both. To determine stdKt/V, the clearance of urea, a function of urea generation and blood concentration, is calculated over a period of one week and is normalized to total body water. For continuous processes, clearance per se is used. For intermittent therapy, two different equations have been developed by Gotch and by Leypoldt. Both equations allow the calculation of stdKt/V from the single-pool Kt/V (spKt/V). Gotch's method requires spKt/V and six other variables. Leypoldt's equation is simpler and limited to spKt/V plus two variables. The present study compared the nomograms created from both equations to determine their equivalence. The nomograms were superimposed for comparison. It also compared the stdKt/V obtained from random simulated patients with each method and the theoretic efficiency of continuous and intermittent clearances. The graphic comparison of the numeric values obtained appeared very similar in both methods, suggesting that either can be useful in clinical practice. A significant theoretic advantage was noted for continuous therapies over intermittent modalities. These results further support the use of frequent, daily, and continuous renal replacement therapies.

Blood Urea Nitrogen↗

Measured versus estimated creatinine clearance in the elderly as an index of renal function.

Measured endogenous creatinine clearance (requiring 24-hour urine collection) was compared to estimated (calculated) creatinine clearance obtained by 2 formulas and a nomogram (without urine collection), in 26 elderly nursing home residents. All were clinically stable and had adequate intakes of food and fluid. Of the 26 subjects, 23 had a "normal" value for serum creatinine concentration (0.7-1.5 mg/dl) with a mean of 1.1 mg/dl. Measured creatinine clearance (Cer) was reduced in all patients despite a "normal" serum creatinine level. The mean Cer was 47.2 ml/min, with values as low as 21.6 ml/min. Measured Cer findings compared well with estimated (calculated) findings, the correlation coefficients being highly significant in all instances. If it is difficult or impossible to collect a 24-hour urine specimen, a fairly accurate assessment of renal function may be obtained by using a simple formula (or nomogram) for estimating creatinine clearance on the basis of the patient's age, weight (height) and serum creatinine level.

Age Factors↗

Estimation of vulnerable zones due to accidental release of toxic materials resulting in dense gas clouds.

Heavy gas dispersion models have been developed at IIT (hereinafter referred as IIT heavy gas models I and II) with a view to estimate vulnerable zones due to accidental (both instantaneous and continuous, respectively) release of dense toxic material in the atmosphere. The results obtained from IIT heavy gas models have been compared with those obtained from the DEGADIS model [Dense Gas Dispersion Model, developed by Havens and Spicer (1985) for the U.S. Coast Guard] as well as with the observed data collected during the Burro Series, Maplin Sands, and Thorney Island field trials. Both of these models include relevant features of dense gas dispersion, viz., gravity slumping, air entrainment, cloud heating, and transition to the passive phase, etc. The DEGADIS model has been considered for comparing the performance of IIT heavy gas models in this study because it incorporates most of the physical processes of dense gas dispersion in an elaborate manner, and has also been satisfactorily tested against field observations. The predictions from IIT heavy gas models indicate a fairly similar trend to the observed values from Thorney Island, Burro Series, and Maplin experiments with a tendency toward overprediction. There is a good agreement between the prediction of IIT Heavy Gas models I and II with those from DEGADIS, except for the simulations of IIT heavy gas model-I pertaining to very large release quantities under highly stable atmospheric conditions. In summary, the performance of IIT heavy gas models have been found to be reasonably good both with respect to the limited field data available and various simulations (selected on the basis of relevant storages in the industries and prevalent meteorological conditions performed with DEGADIS). However, there is a scope of improvement in the IIT heavy gas models (viz., better formulation for entrainment, modification of coefficients, transition criteria, etc.). Further, isotons (nomograms) have been prepared by using IIT heavy gas models for chlorine, which provide safe distance for various storage amounts for 24 meteorological scenarios prevalent in the entire year. These nomograms are prepared such that a nonspecialist can use them easily for control and management in case of an emergency requiring the evacuation of people in the affected region. These results can also be useful for siting and limiting the storage quantities.

Accidents, Occupational↗

Comparison of formulae for heart rate correction of QT interval in exercise electrocardiograms.

The study investigated the differences in five different formulae for heart rate correction of the QT interval in serial electrocardiograms recorded in healthy subjects subjected to graded exercise. Twenty-one healthy subjects (aged 37+/-10 years, 15 male) were subjected to graded physical exercise on a braked bicycle ergometer until the heart rate reached 120 beats/min. Digital electrocardiograms (ECG) were recorded on baseline and every 30 seconds during the exercise. In each ECG, heart rate and QT interval were measured automatically (QT Guard package, Marquette Medical Systems, Milwaukee, WI, USA). Bazett, Fridericia, Hodges, Framingham, and nomogram formulae were used to obtain QTc interval values for each ECG. For each formula, the slope of the regression line between RR and QTc values was obtained in each subject. The mean values of the slopes were tested by a one-sample t-test and the comparison of the baseline and peak exercise QTc values was performed using paired t-test. Bazett, Hodges, and nomogram formulae led to significant prolongation of QTc intervals with exercise, while the Framingham formula led to significant shortening of QTc intervals with exercise. The differences obtained with the Fridericia formula were not statistically significant. The study shows that the practical meaning of QT, interval measurements depends on the correction formula used. In studies investigating repolarization changes (e.g., due to a new drug), the use of an ad-hoc selected heart rate correction formula is highly inappropriate because it may bias the results in either direction.

Adult↗

Population-based incidence and outcome of acetaminophen poisoning by type of ingestion.

OBJECTIVES: 1) To determine, in a population-based sample, the observed frequency of acetaminophen overdose-related ED evaluation and hospitalization. 2) To examine the relative frequency of hospitalization by pattern of ingestion, the outcome of each group, and the presence or absence of postulated risk factors. METHODS: This study was a 46-month, retrospective chart review of all acetaminophen-related visits, by patients at least 10 years of age, to either of the two hospitals that serve a four-county region of central Virginia. RESULTS: Of 636 charts identified for review, only 137 involved acute or chronic acetaminophen overdose. One hundred twenty-six patients presented after an acute ingestion; 122 of these patients gave a history of a single, supratherapeutic ingestion of acetaminophen. Twenty-five patients were hospitalized for treatment. Eighteen of these were treated with N-acetylcysteine (NAC) based on the Rumack-Matthew nomogram; one suffered significant hepatic injury. The other seven presented at least 18 hours after ingestion, with no measurable serum acetaminophen. Two of these suffered significant hepatic injury. Four additional patients presented after multiple ingestions within 24 hours. Three were hospitalized, but none experienced significant injury. Only 11 patients were evaluated for chronic acetaminophen overmedication for pain (more than 6 g/day over a period of more than 24 hours). Four were admitted for treatment; three suffered significant hepatic injury. Thus, the observed incidence of acute acetaminophen ingestion in this region was 21.4/100,000/yr (95% CI = 17.7 to 25.2). The observed incidence of hospitalization for acute acetaminophen toxicity was 4.8/100,000/yr (95% CI = 3.0 to 6.5). The observed incidence of hospitalization for all acetaminophen poisoning was 5.5/100,000/yr (95% CI = 4.1 to 7.0). High ethanol consumption was present more frequently in those who suffered hepatic injury. CONCLUSIONS: Most patients evaluated for acetaminophen ingestion present early following acute single overdose. Relatively few of these patients require hospitalization and, for those hospitalized, the outcome is good. More significantly, acetaminophen overdose patients whose risk cannot be estimated using the Rumack-Matthew nomogram represented 44% of those hospitalized and 83% of those who suffered significant hepatic injury. Emergency physicians need to determine how they can impact the outcome of these patients. Efforts should be directed at further characterizing historical, physical, and biochemical markers of risk and at determining in which circumstances hospitalization for NAC or other therapies is justified.

Acetaminophen↗

Comparative pharmacokinetics of Panadol Extend and immediate-release paracetamol in a simulated overdose model.

BACKGROUND: Panadol Extend is a modified-release paracetamol formulation in which each 665 mg tablet contains 69% slow-release and 31% immediate-release paracetamol. There are no data on Panadol Extend pharmacokinetics in overdose. It is unknown whether the paracetamol treatment nomogram can be used to make decisions regarding the toxicity of this product in overdose. OBJECTIVE: To compare the pharmacokinetics of Panadol Extend and immediate-release paracetamol (APAP-IR) in simulated overdose model in healthy volunteers. METHODS: Cross-over study using a dose of 90 mg/kg ideal body weight of Panadol Extend or APAP-IR in seven healthy volunteers. Serum paracetamol concentrations were measured over 12 h. Maximal paracetamol concentration (Cmax), time to Cmax (Tmax), area under the curve (AUC) and elimination half-life (t(1/2)) were compared. RESULTS: Mean paracetamol dose was 73 mg/kg actual body weight. Panadol Extend produced lower Cmax (0.208 mmol/L +/- 0.02 vs 0.48 mmol/L +/- 0.02, P = 0.0001) and AUC(0-12 h) when compared with APAP-IR. Tmax was delayed with Panadol Extend (2.83 h +/- 0.26 vs 0.94 h +/- 0.17, P = 0.0001). Absorption was complete in all subjects by 4 h post ingestion in both study arms. Elimination t(1/2) was 1.69 +/- 0.09 h for APAP-IR and 1.65 +/- 0.13 h for Panadol Extend (not significant). CONCLUSIONS: Reductions in Panadol Extend Cmax and AUC(0-12 h) might be related to elimination occurring during the absorption phase. In this model of Panadol Extend moderate overdose, Tmax was significantly delayed. In larger overdoses, time to peak paracetamol levels might be further delayed, because of continuing absorption from the formulation. Therefore, the paracetamol treatment nomogram might not reliably predict hepatotoxicity from Panadol Extend if paracetamol levels are measured too early.

Absorption↗

Plasma beta 2 microglobulin as a means of predicting gentamicin serum concentrations.

A novel and accurate method for predicting gentamicin peak serum concentration is described. The method considers body weight and renal function as determined by the concentration of beta 2 microglobulin in plasma. In 32 subjects whose renal function ranged from normal to severely impaired, the peak serum concentration of gentamicin was more closely correlated with beta 2 microglobulin (r = 0.69) and with creatinine clearance (r = 0.69) than with serum creatinine (r = 0.53). A nomogram was constructed which related plasma beta 2 microglobulin concentrations and body weight to predicted gentamicin peak serum concentrations. When the nomogram was clinically applied, the predicted peak gentamicin concentrations corresponded closely to the actual measurements obtained (t = 0.64; P is not significant). We suggest that plasma beta 2 microglobulin concentrations compare favorably with serum creatinine values in the prediction of gentamicin peak concentrations in patients with renal impairment.

Adult↗

Identifying newborns at risk of significant hyperbilirubinaemia: a comparison of two recommended approaches.

AIMS: To compare the predictive performance of clinical risk factor assessment and pre-discharge bilirubin measurement as screening tools for identifying infants at risk of developing significant neonatal hyperbilirubinaemia (post-discharge total serum bilirubin (TSB) >95th centile). METHODS: Retrospective cohort study of term and near term infants born in an urban community teaching hospital in Pennsylvania (1993-97). A clinical risk factor scoring system was developed and its predictive performance compared to a pre-discharge TSB expressed as a risk zone on a bilirubin nomogram. Main outcome measures were prediction model discrimination, range of predicted probabilities, and sensitivity, specificity, positive and negative predictive values, and likelihood ratios for various positivity criteria. RESULTS: The clinical risk factor scoring system developed included birth weight, gestational age <38 weeks, oxytocin use during delivery, vacuum extraction, breast feeding, and combination breast and bottle feeding. The pre-discharge bilirubin risk zone had better discrimination (c = 0.83; 95% CI 0.80 to 0.86) than the clinical risk factor score (c = 0.71; 95% CI 0.66 to 0.76) and predicted risk of significant hyperbilirubinaemia as high as 59% compared with a maximum of 44% for the clinical risk factor score. Neither the risk score nor the pre-discharge TSB risk zone predicted the outcome with > or =0.98 sensitivity without significantly compromising specificity (0.13 and 0.21, respectively). Multi-level clinical risk factor scores and TSB risk zones produced likelihood ratios of 0.15-3.25 and 0.05-9.43, respectively. CONCLUSIONS: The pre-discharge bilirubin expressed as a risk zone on an hour specific bilirubin nomogram is more accurate and generates wider risk stratification than a clinical risk factor score.

Cohort Studies↗

Maximal oxygen intake estimated from submaximal heart rate.

This study investigated the predictability of maximal oxygen intake from three different submaximal heart rates assessed during an initial and follow-up ride on a cycle ergometer. Twenty-four healthy male subjects performed workloads of 600, 750, and 900 kpm's for six minutes on each of two visits to the laboratory. Analysis of variance for a randomised complete blocks design, with subjects constituting blocks, was used to analyse heart rate, estimated maximal oxygen intake, and residual estimated maximal oxygen intake variations among the experimental conditions. Relationships between the actual and estimated maximal oxygen intakes were determined using the Pearson Product-Moment formula of correlation. The average estimated maximal oxygen intake was significantly increased from the first testing occasion to the second. Although errors of estimation decreased significantly (450 ml to 366 ml) in favour of the second testing condition, the decrease was neither consistent with workloads nor subjects. The correlation coefficients were consistently low at 600 kpm for both testing occasions (0.68 and 0.73, respectively), consistently high at 750 kpm (0.82 and 0.84, respectively), and quite variable at 900 kpm (0.71 and 0.84, respectively), indicated that the validity of the nomogram was not consistent with all workloads or testing occasions. Despite these inconsistencies, the nomogram is, for practical purposes, a valid predictor of maximal oxygen consumption.

Adolescent↗

The impact of nationally distributed guidelines on the management of paracetamol poisoning in accident and emergency departments. National Poison Information Service.

OBJECTIVE: To assess the impact of the treatment guidelines on the management of paracetamol self poisoning in accident and emergency (A&E) departments. METHODS: 24 A&E departments in Wales and England provided details of their management of paracetamol poisoning before and after the distribution of national treatment guidelines to all A&E departments in the United Kingdom. RESULTS: Significant increases were seen in the availability of formal written policies, the display of treatment nomograms, the recommendation to treat beyond 16 hours after ingestion, and to use a lower line on the treatment nomogram for patients at special risk of paracetamol induced liver damage. CONCLUSIONS: Regularly updated guidelines in the management of paracetamol poisoning should be displayed in A&E departments so that medical and nursing personnel have access to the best current information on the treatment of poisoning with this frequently used drug.

Acetaminophen↗

QT interval as a cardiac risk factor in a middle aged population.

OBJECTIVE: To evaluate the value of QT interval as a cardiac risk factor in middle aged people. METHODS: The association between QT interval and cardiac risk factors and mortality in a middle aged Finnish population of 5598 men and 5119 women was evaluated over a 23 year follow up. To adjust the QT interval confidently for heart rate, a nomogram was constructed from the baseline electrocardiograms separately for men and women. RESULTS: Nomogram-corrected QT interval (QTNc) prolongation was associated with elevated blood pressure and signs of cardiovascular disease; QTNc shortening was associated with smoking. Over 10% prolongation of QTNc predicted death in men with heart disease: adjusted relative risk (RR) was 2.17 (95% confidence interval 0.67-7.45) for sudden death; 2.12 (1.25-3.59) for total cardiovascular mortality; and 1.92 (1.23-3.00) for all cause mortality. In healthy men the increase in RR was not significant: sudden death, 1.48 (0.67-3.25); total cardiovascular mortality, 1.25 (0.92-1.70); all cause mortality, 1.21 (0.96-1.53). However, healthy men with long QTNc in the lowest heart rate quartile exhibited an RR of 2.75 (1.00-7.40) for sudden death. Over 10% shortened QTNc predicted cardiovascular death in men with heart disease who smoked; RR 3.72 (1.45-9.54). Non-smoking men with short QTNc had low mortality risks irrespective of possible signs of cardiovascular disease. The trends in mortality risks were similar but weaker for women. CONCLUSIONS: In a middle aged population, prolonged QT interval predicts cardiac mortality in men with signs of cardiovascular disease. In women and healthy men this risk is weak and may reflect subclinical heart disease. A shortened QT interval predicts death in men with heart disease who smoke.

Adult↗