ASTM standards for fire debris analysis: a review.

The American Society for Testing and Materials (ASTM) recently updated its standards E 1387 and E 1618 for the analysis of fire debris. The changes in the classification of ignitable liquids are presented in this review. Furthermore, a new standard on extraction of fire debris with solid phase microextraction (SPME) was released. Advantages and drawbacks of this technique are presented and discussed. Also, the standard on cleanup by acid stripping has not been reapproved. Fire debris analysts that use the standards should be aware of these changes.

Journal Article↗

Automated headspace solid-phase dynamic extraction for the determination of cannabinoids in hair samples.

This article describes a fully automated procedure for detecting cannabinoids in human hair samples. The procedure uses alkaline hydrolysis and headspace solid-phase dynamic extraction (HS-SPDE), followed by on-coating derivatization and gas chromatography-mass spectrometry (GC-MS). SPDE is a further development of solid-phase microextraction (SPME), based on an inside needle capillary absorption trap. It uses a hollow needle with an internal coating of polydimethylsiloxane as extraction and pre-concentration medium. Ten mg of hair were washed with deionised water, petroleum ether and dichloromethane. After adding deuterated internal standards, the sample was hydrolyzed with sodium hydroxide and directly submitted to HS-SPDE. After absorption of analytes for an on-coating derivatization procedure, the SPDE-needle was directly placed into the headspace of a second vial containing N-methyl-N-trimethylsilyl-trifluoroacetamide before GC-MS analysis. The limit of detection was 0.14 ng/mg for Delta(9)-tetrahydrocannabinol, 0.09 ng/mg for cannabidiol, and 0.12ng/mg for cannabinol. Absolute recoveries were in the range of 0.6 to 8.4%. Linearity was verified over a range from 0.2 to 20 ng/mg, with coefficients of correlation between 0.998 and 0.999. Intra- and inter-day precision were determined at two different concentrations and resulted in ranges between 2.3 and 6.0% (intra-day) and 3.3 and 7.6% (inter-day). Compared with conventional methods of hair analysis, this automated HS-SPDE-GC-MS procedure is substantially faster. It is easy to perform without using solvents and with minimal sample quantities, and it yields the same sensitivity and reproducibility. Compared to SPME, we found a higher extraction rate, coupled with a faster automated operation and greater stability of the device.

Cannabinoids↗

Detection of thiopental and pentobarbital in head and pubic hair in a case of drug-facilitated sexual assault.

The quali-quantitative determination of two barbiturates, thiopental and its metabolite pentobarbital, in head and pubic hair samples of a woman who had been sexually assaulted during hospitalisation, is reported. Hair was analysed by means of solid-phase microextraction (SPME) and gas chromatography-multiple mass spectrometry (GC-MS-MS), in chemical ionisation conditions. Thiopental and pentobarbital were found in three proximal head hair segments (sample 1A: 0.30 and 0.40 ng/mg; sample 1B: 0.20 and 0.20 ng/mg; sample 3: 0.15 and 0.20 ng/mg) and pubic hair sample. Two distal head hair segments were negative for both barbiturates. Despite the lack of collection and toxicological analysis of blood or urine samples within the hospital setting, analytical findings from hair revealed the use of the anaesthetic agent thiopental to sedate the victim quickly and deeply and commit sexual assault.

Female↗

Are there possibilities for the detection of chronically elevated alcohol consumption by hair analysis? A report about the state of investigation.

The analysis of suitable ethanol markers in hair would be an advantageous tool for chronic alcohol abuse control because of the wide diagnostic window allowed by this specimen and the possibility of segmental investigation. Between the markers practically used or thoroughly investigated in blood or urine, ethylglucuronide, fatty acid ethylesters, phosphatidylethanol, acetaldehyde adducts to protein and 5-hydroxytryptophol can be regarded as possible candidates also in hair, but preliminary data were found in the literature only for ethylglucuronide and acetaldehyde modified proteins. By using headspace gas chromatography and headspace solid phase microextraction in combination with gas chromatography-mass spectrometry (SPME-GC/MS), in alkaline hydrolysates of hair it was possible to determine between 17 and 135 ng/mg of ethanol beside acetone and several other volatile compounds with slightly higher ethanol values for alcoholics than for social drinkers and teetotalers. A part of this is ethanol only absorbed in the hair matrix from the surrounding environment and consequently is not applicable as a diagnostic criterion. By extraction with aqueous buffer, methanol or a methanol/chloroform mixture and subsequent alkaline hydrolysis it was found that another part is generated from ethylesters, which are preferentially deposited in the lipid fraction of hair. In a specific search for ethylesters of 17 carboxylic acids by GC/MS-SIM in most cases ethyl 4-hydroxybenzoate (0.1 to 5.9 ng/mg, a preservative in hair cosmetics) and in four cases traces of indolylacetic acid ethylester were found. Furthermore, diethyl phthalate (a softening agent, present also in many cosmetic products) was identified in the hair of alcoholics as well as of children. As potential markers of alcohol intake, ethyl palmitate, ethyl stearate and ethyl oleate were detected in hair samples of alcoholics by headspace SPME-GC/MS of the chloroform/methanol extracts.

Acetaldehyde↗

Headspace SPME method development for the analysis of volatile polar residual solvents by GC-MS.

A solid-phase microextraction (SPME) method has been developed and optimized for the polar residual solvent determination in pharmaceutical products. Five different polymer-coated fibers were investigated and the Carboxen/polydimethylsiloxane was found to be the most sensitive for all components. Two Headspace SPME methods were developed and optimized: one for the extraction from aqueous solutions, and the other for the extraction from organic solutions (N,N-dimethyl formamide (DMF) and dimethyl sulfoxide (DMSO). The optimum equilibration time for all components and all systems was 30 min. It was found that the sample headspace volume has an important effect on method sensitivity and precision. At low headspace volumes (less than one-third of the vial volume), sensitivity improves but at the same time, precision worsens. For 10 ml headspace vials, the optimum headspace volume was found to be 3 ml. The total volatile organic content in the sample also has an important effect on method sensitivity and precision. At low organic content, sensitivity increases but precision drops significantly. Over 0.5% volatile organic content in the sample, the system becomes unstable due to stationary phase swelling by the organic components, and also the sensitivity of the method is drastically reduced. The optimum range for total volatile organic content was found to be between 0.01 and 0.1%. The added Na2SO4 quantity increases the extraction yield. It was found that slightly pressurizing the headspace vial improves the sensitivity of the method by a factor of 2. For the organic system, it was found that the addition of 100 microl DMSO or DMF to 50 mg drug substance and slightly pressurizing the headspace vial gives good results in terms of sensitivity and reproducibility. The measured detection limits were between 0.4 and 200 ng/ml, and the relative standard deviation data were between 2 and 9%. The Headspace SPME from aqueous solutions was found to be ten times more sensitive than Immersion SPME and Headspace SPME from organic solutions.

Dimethyl Sulfoxide↗

SPME-LC with UV detection to study delorazepam-serum albumin interactions.

Solid phase microextraction coupled to high performance liquid chromatography with UV detection (SPME/LC-UV) has been employed to study the binding of delorazepam to human serum albumin (HSA) and bovine serum albumin (BSA). The procedure could also be potentially extended to the measurement of partition coefficients between a wide variety of semi- or non-volatile compounds and matrices. The method is solvent free, simple, fast, and drawbacks of the conventional analytical techniques are avoided. Moreover, the matrix did not interfere with the measurement by binding to the fibre and the amount extracted by the fibre was negligibly small; thus it did not disturb the delorazepam-protein binding.

Anti-Anxiety Agents↗

Simple and rapid analysis of endocrine disruptors in liquid medicines and intravenous injection solutions by automated in-tube solid-phase microextraction/high performance liquid chromatography.

A simple and rapid method was developed for analyzing contamination of endocrine disruptors in liquid medicines and intravenous injection solutions. Endocrine disrupting compounds such as bisphenol A (BPA), alkylphenols and phthalates were quantitated by on-line in-tube solid-phase microextraction coupled with high performance liquid chromatography (in-tube SPME/HPLC) with UV detection. The liquid medicines and intravenous injection solutions could be used directly without any pretreatment, and the BPA, alkylphenols and phthalates in these solutions were automatically analyzed. The limits of quantification for these compounds were 1-10 ng/ml. Recoveries of these compounds spiked to the intravenous injection solutions was over 80%, except for some phthalates. Di-n-butyl phthalate (DBP) was detected at a concentration of 7-60 ng/ml in most intravenous injection solutions in plastic containers, but it was not detected in solutions in glass bottles. Diethyl phthalate, di-n-propyl phthalate, DBP and di-2-ethylhexyl phthalate (DEHP) were also detected in syrup, lotion and eye drops in plastic containers. On the other hand, BPA and alkylphenols were not detected at all in these solutions. DEHP contamination from an administration set increased when total vitamin formulation was added to the infusion solution. DEHP was easily leached from polyvinyl chloride tubing by polysorbate 80. The in-tube SPME/HPLC method is simple, rapid and automatic, and it provides a useful tool for the screening and determination of endocrine disruptor contamination in liquid medicines and intravenous injection solutions.

Autoanalysis↗

Residual solvents determination in pharmaceutical products by GC-HS and GC-MS-SPME.

Solid-phase microextraction (SPME) has been applied to the residual solvents determination in pharmaceutical products and was compared with the static headspace. Three fibers with different polymer films were compared and the polydimethylsiloxane/divinylbenzene coated fiber was found to be the most sensitive for the analyzed analytes. Between the investigated sample preparation techniques, gastight-SPME proved to be the most sensitive, with DL values ranging from 5 pg ml(-1) to 2 ng ml(-1). Headspace SPME is more precise, with RSD of peak areas values ranging from 2 to 3%. The headspace SPME method was successfully validated. The validation data are reported in the text. The most important difference between the two techniques is that the gastight SPME showed better behavior towards very volatile solvents. Compared with the static headspace technique, both SPME methods showed superior results, being compatible with the pharmaceutical samples.

Drug Contamination↗

Sonochemical degradation of ethylbenzene in aqueous solution: a product study.

The degradation of ethylbenzene in aqueous solution by 520 kHz ultrasound was investigated. The products formed were analysed using solid phase microextraction (SPME), a sampling technique that allows convenient GC-MS and GC-FID analysis in the micromolar range. A broad range of monosubstituted monocyclic and dicyclic aromatic hydrocarbons was found as well as some oxygenated products. The results clearly indicate that pyrolysis is an important pathway of ethylbenzene degradation. The side chain is dehydrogenated, forming styrene, or cleaved. The radicals formed upon cleavage are subsequently added to the double bond of the styrene side chain or recombined. This mechanism explains the formation of most of the products. Formation and breakdown of the reaction products follow first-order kinetics in spite of the fact that the selectivity of the reactions depends on the initial ethylbenzene concentration considerably. Changes in the temperature and the pressure of cavitation are expected to cause this dependence.

Journal Article↗

High-resolution microanalysis of nitrite and nitrate in neuronal tissues by capillary electrophoresis with conductivity detection.

Nitrites and nitrates are widely used reporters of endogenous activity of nitric oxide synthases (NOS), an important group of enzymes producing the gaseous signal molecule nitric oxide (NO). However, due to the great chemical heterogeneity of neuronal tissues, standard analytical protocols for evaluation of neuronal nitrite/nitrate concentrations are inefficient. We optimized a high-performance capillary zone electrophoresis (CZE) technique to analyze nitrite/nitrate concentrations in submicroliter samples from mammalian neuronal tissues. The measurements were made using a PrinCE 476 computerized capillary electrophoresis system with a Crystal 1000 contact conductivity detector. Isotachophoretic stacking injection of 1000- to 10000-fold diluted samples, which had been pretreated with a custom-designed solid-phase microextraction (SPME) cartridge, was employed to assay micromolar and nanomolar nitrite and nitrate levels in the presence of the high millimolar chloride concentrations characteristic of many biological samples. In the presented technique, a 10-microl volume of diluted ganglionic sample was used for chloride removal and sample cleanup. The method yields high analytical performance, including good reproducibility, resolution, and accuracy. The limits of detection relative to undiluted sample matrix were 8.9 nM (0.41 ppb) and 3.54 nM (0.22 ppb) for nitrite and nitrate, respectively. In addition, this technique resolves other anions that are present in neuronal tissues at sub-nanomolar concentrations and can be broadly applied for high-throughput anionic profiling. In rat dorsal root ganglia, endogenous levels of nitrate (231+/-29 microM; n=6) and nitrite (24-96 microM) were found. These concentrations exceeded those previously found in neuronal tissue homogenates using different techniques.

Electrophoresis, Capillary↗

High trimethylamine concentration in milk from cows on standard diets is expressed as fishy off-flavour.

To establish whether fishy off-flavour observed in cows' milk in Sweden is due to abnormal concentrations of trimethylamine (TMA) in milk, 15 milk samples from 13 cows of the Swedish Red and White breed (SRB) were analysed for this compound using dynamic headspace (DHS) gas chromatography (GC). A mass selective detector (MSD) was used for the qualitative and a flame ionization detector (FID) for the quantitative analyses. Further confirmation was obtained using a solid phase microextraction (SPME) followed by GC-olfactometry (GC-O) and GC-NPD (nitrogen and phosphorus detector). Samples were also evaluated by a two-person organoleptic panel for the presence of fishy off-flavour. Results showed that the seven milk samples with a fish-like taint contained > 1 mg TMA/kg milk, whereas, with a single exception, the seven samples that were judged to be normal did not contain this compound. Furthermore, there were indications of a dose-dependent relationship between TMA concentration and fishy off-flavour score.

Animal Feed↗

Effect of specific wavelengths on light-induced quality changes in Havarti cheese.

The effects of exposure of slices of Havarti cheeses to monochromatic light of wavelengths 366 nm, 405 nm, and 436 nm, respectively, were studied by tristimulus colorimetry, solid-phase microextraction gas chromatographic analysis of volatiles, and open-end fluorescence spectroscopy. Having determined the photon fluxes of the three wavelengths by ferrioxalate actinometry, it was possible to quantify the effects of light exposure in an absolute manner. For all analyses, the most severe effects were caused by visible light, leading to colour bleaching, change in hue, riboflavin degradation, and formation of the secondary oxidation products hexanal, 1-pentanol, and 1-hexanol. Apparent quantum yields for formation of hexanal and 1-pentanol were found to be insignificantly different for 405 nm and 436 nm exposures, having values of (3-5) x 10(-5) mol x einstein(-1) and (9-13) x 10(-5) mol x einstein(-1), respectively. These compounds were not formed when exposed to 366 nm light. In contrast, 1-hexanol was formed when exposing cheese to all three wavelengths, resulting in apparent quantum yields of (2-6) x 10(-5) mol x einstein(-1). The results obtained are discussed in relation to the interplay between inherent product colorants, light sources, and transmission characteristics of the packaging materials.

Aldehydes↗

Sampling and analysis of airborne particulate matter and aerosols using in-needle trap and SPME fiber devices.

A needle trap device (NTD) and commercial poly(dimethylsiloxane) (PDMS) 7-microm film thickness solid-phase microextraction (SPME) fibers were used for the sampling and analysis of aerosols and airborne particulate matter (PM) from an inhaler-administered drug, spray insect repellant, and tailpipe diesel exhaust. The NTD consisted of a 0.53-mm o.d. stainless steel needle having 5 mm of quartz wool packing section near the needle tip. Samples were collected by drawing air across the NTD with a Luertip syringe or via direct exposure of the SPME fiber. The mass loading of PM was varied by adjusting the volume of air pulled through the NTD or by varying the sampling time for the SPME fiber. The air volumes ranged from 0.1 to 50 mL, and sampling times varied from 10 s to 16 min. Particulates were either trapped on the needle packing or sorbed onto the SPME fiber. The devices were introduced to a chromatograph/mass spectrometer (GC/MS) injector for 5 min desorption. In the case of the NTD, 10 microL of clean air was delivered by a gas-tight syringe to aid the introduction of desorbed analytes. The compounds sorbed onto particles extracted by the SPME fiber or trapped in the needle device were desorbed in the injector and no carry-over was observed. Both devices performed well in extracting airborne polycyclic aromatic hydrocarbons (PAHs) in diesel exhaust, triamcinolone acetonide in a dose of asthma drug and DEET in a dose of insect repellant spray. Results suggest that the NTDs and PDMS 7-microm fibers can be used for airborne particulate sampling and analysis, providing a simple, fast, reusable, and cost-effective screening tool. The advantage of the SPME fiber is the open-bed geometry allowing spectroscopic investigations of particulates; for example, with Raman microspectroscopy.

Journal Article↗

Microwave-assisted generation of standard gas mixtures.

Microwave heating was employed for preparation of the standard gas of volatile organic compounds (VOCs) and semivolatile organic compounds (semi-VOCs) by using a 1000 W commercial domestic microwave oven and 1 L gas-sampling bulbs. The VOCs investigated were benzene, chloroform, 1,3-dichlorobenzene, tetrachloroethylene, toluene, and 1,1,2-trichloroethane, and the semi-VOCs used were the polychlorinated biphenyls (PCBs) PCB 1016 and PCB 1248. Since these weakly or nonpolar molecules are very poor absorbers of microwave energy, an appropriate amount of water was introduced to accept microwave radiation and act as the thermal source to accelerate their evaporation. The glass bulb may also contribute thermal energy to the VOCs/semi-VOCs by accepting microwave energy to a small degree. For 0.5 microL of liquid VOCs on 10 mg of glass wool, it was shown that 15 microL of H2O and 60 s of microwave heating yielded a very efficient evaporation [97.2-106.4%, compared with a classic method (Muller, L; Gorecki, T.; Pawliszyn, J. Fresenius' J. Anal. Chem. 1999, 364, 610-616)]. For 1 microL of PCB solution (1000 microg/mL in hexane), 15 microL of H2O and 90 s of microwave heating also provided a complete evaporation. The addition of water was particularly significant for microwave-assisted evaporation of PCBs because semi-VOCs are much more difficult to evaporate than VOCs. This developed microwave technique proved to be quite simple, powerful, rapid, accurate, and safe for the preparation of VOC/semi-VOC standard gas. Solid- phase microextraction combined with gas chromatography was used for the gas analysis.

Air Pollution↗

Steady-state concentration distribution of artificial receptor and target analyte in plasticized PVC membrane between solutions differing in target analyte concentration.

A barbiturate receptor has proven effective in improving selectivity in solid-phase microextraction of barbiturates when doped into plasticized poly(vinyl chloride) (PVC). It would be beneficial to have selective extractions for any given organic species; however, the receptors do not exist. They will be found by screening of libraries of potential receptors; thus, a screening method is needed. It is important to screen the receptors in the medium in which they will work: plasticized PVC. We hypothesize that we can make receptors move in solution in response to the presence of a solute to which they bind. This work examines whether we can establish a sufficient free energy gradient for a good receptor to move to a predetermined place in space. A difference in the barbiturate solute (substrate or guest) concentration in solutions bathing the two sides of a plasticized PVC membrane containing the barbiturate receptor (or host) creates a spatial concentration gradient of the substrate in the membrane. This causes the receptor's chemical potential to vary across the membrane. Upon binding to the analyte, the receptor undergoes a local activity drop, which decreases its free energy. This process produces a flux of receptor to accumulate at place where there is a high substrate concentration. A concentration gradient of substrate can be maintained across the membrane at steady state. In membranes for which the formation of the complex is favored, the receptor responds to the gradient of substrate. In membranes for which binding is not favored, a gradient of substrate is completely ignored by the receptor. Thus, the receptor does respond to the gradient but only if the concentration gradient of guest corresponds to a chemical potential gradient.

Barbiturates↗

Improvement of measurement precision of SPME-GC/MS determination of tributyltin using isotope dilution calibration.

A unique approach was developed to improve the precision of quantification of tributyltin (TBT) in sedimentsby solid phase microextraction (SPME) using isotope dilution GC/MS. The precision of the analytical technique was initially evaluated using standard calibration solutions. In selective ion monitoring (SIM) mode, the relative standard deviation (RSD) obtained for TBT based on peak area response was 18% (n = 11). When an internal standard, tripropyltin (TPrT), was used, the RSD decreased to 12%. A significant improvement in the precision using SPME was noted when a 117Sn-enriched TBT spike was employed; the RSD decreased 4-fold to 3%. Detection limits of 0.2 and 20 ng(Sn) L(-1) were achieved with SPME sampling and liquid-liquid extraction, respectively. Six analyses were performed for determination of TBT in PACS-2 sediment Certified Reference Material using both standard additions and isotope dilution procedures. For the latter, a 117Sn-enriched TBT spike was used. A concentration of 0.88 +/- 0.03 microg g(-1) (RSD 3.4%) obtained using standard additions was in good agreement with the certified value of 0.98 +/- 0.13 microg g(-1) as tin. Concentrations found using isotope dilution were 0.895 +/- 0.015 microg g(-1) (RSD 1.73%) as tin and 0.874 +/- 0.014 microg g(-1) (RSD 1.66%) as tin using a liquid-liquid extraction and SPME sampling, respectively. A 2-fold improvement in the precision of TBT concentration measurement using isotope dilution was clearly achieved, demonstrating its superiority in providing more accurate and precise results as compared to the method of standard additions. The isotope dilution technique eliminated the problem of poor reproducibility, which typically plagues SPME.

Calibration↗

Effect of polymer concentration on partitioning and molecular recognition in plasticized poly(vinyl chloride).

Mixtures of poly(vinyl chloride) (PVC) with plasticizers have been used in ion-selective electrodes for many years. The same material has proven useful in solid-phase microextraction (SPME), both with and without artificial receptors. We hypothesized that by changing the polymer concentration in plasticized PVC membranes containing artificial receptor from the standard 33 wt %, the selectivity of the extraction of barbiturates over similar molecules could be improved. Partition coefficients and receptor-substrate formation constants of a target species, phenobarbital, in membranes with various polymer concentrations were determined. Diffusion coefficients of the solute phenobarbital in receptor-free membranes were also determined. Kamlet-Taft solvatochromic properties beta and pi* were measured for the PVC/dioctyl sebacate materials. Cohesive energy densities were calculated for the same materials. Partition coefficients for phenobarbital (from aqueous solution to membrane) decrease as [PVC] increases, while the formation constants for the complex of the solute with its receptor increase. Diffusion coefficients decrease as the polymer concentration increases as well. The increase in polymer concentration brings about a decrease in hydrogen-bonding basicity and an increase in dipolarity and cohesive energy density. The values of the solvatochromic parameters determined at various compositions are highly correlated; thus, it is impossible to calculate how much each factor contributes to the changes associated with partition and complex formation. The solvatochromic "polarizability correction factor" has been determined to be 0 for PVC. In SPME experiments at 30%, 40%, and 50% (w/w) PVC, as polymer concentration increases, selectivity for barbiturate extraction over other cyclic imides becomes better in the presence of barbiturate receptor and worse without receptor.

Journal Article↗

Compound-specific carbon isotope analysis of volatile organic compounds in the low-microgram per liter range.

Compound-specific carbon isotope analysis (CSIA) has become an important tool in biological, archeological, and geological studies as well as in forensics, food sciences, and organic chemistry. If sensitivity could be enhanced, CSIA would further have an improved potential for environmental applications such as, for example, in situ remediation studies to assess contaminated environments, identification of pollutant degradation pathways and kinetics, distinction between degradation/formation mechanisms, or, verification of contaminant sources. With this goal in mind, we have developed methods to determine delta13C values of commonly reported groundwater contaminants in low-microgram per liter concentrations. Several injection and preconcentration techniques were evaluated for this purpose, i.e., on-column injection, split/ splitless injection, solid-phase microextraction (SPME), and purge and trap (P&T) in combination with gas chromatography-isotope ratio mass spectrometry. The delta13C values of the target compounds were determined by liquid injections of the analytes dissolved in diethyl ether or, in the case of P&T and SPME, by extraction from water spiked with the analytes. P&T extraction was the most efficient preconcentration technique reaching method detection limits (MDLs) from 0.25 to 5.0 microg/L. These are the lowest MDLs reported so far for continuous-flow isotope ratio determinations, using a commercially available and fully automated system. Isotopic fractionation resulting from preconcentration and injection was investigated and quantified for the priority groundwater pollutants methyl tert-butyl ether (MTBE), chloroform, tetrachloromethane, chlorinated ethylenes, benzene, and toluene. The isotopic fractionations caused by the extraction techniques were small but highly reproducible and could therefore be corrected for. P&T was characterized by a higher reproducibility and smaller isotopic fractionations than SPME. Among the liquid injection techniques, cold on-column injection resulted in slightly better precision compared to split/splitless injection. However, the MDLs determined for liquid injections were 4-6 orders of magnitude higher (i.e., 9.5-2800 mg/L) than for P&T and SPME. Since both of the latter methods are solventless, a better chromatographic resolution was obtained than for the liquid injection techniques. The P&T and SPME methods described here are also applicable for CSIA of D/H ratios, which require 10-20 times higher analyte concentrations than 13C/12C analysis. Finally, the applicability of the described methods is demonstrated for pollutant concentrations of only 5-60 microg/L in environmental samples.